| hostName | The host name or IP address of the thermostat. Mandatory. |
| refresh | Overrides the refresh interval of the thermostat data. Optional, the default is 2 minutes. |
| logRefresh | Overrides the refresh interval of the run-time logs & humidity data. Optional, the default is 10 minutes. |
| isCT80 | Flag to enable additional features only available on the CT80 thermostat. Optional, the default is false. |
| disableLogs | Disable retrieval of run-time logs from the thermostat. Optional, the default is false. |
| setpointMode | Controls temporary or absolute setpoint mode. In "temporary" mode the thermostat will temporarily maintain the given setpoint until the next scheduled setpoint time period. In "absolute" mode the thermostat will ignore its program and maintain the given setpoint indefinitely. Optional, the default is "temporary". |
| clockSync | Flag to enable the binding to sync the internal clock on the thermostat to match the openHAB host's system clock. Use if the thermostat is not setup to connect to the manufacturer's cloud server. Sync occurs at binding startup and every hour thereafter. Optional, the default is false. |
- The main caveat for using this binding is to keep in mind that the web server in the thermostat is very slow. Do not over load it with excessive amounts of simultaneous commands.
- When changing the thermostat mode, the current temperature set point is cleared and a refresh of the thermostat data is done to get the new mode's set point.
- Since retrieving the thermostat's data is the slowest operation, it will take several seconds after changing the mode before the new set point is displayed.
- The 'Program Mode' command is untested and according to the published API is only available on a CT80 Rev B.
- Humidity information is available only when using a CT80 thermostat.
| temperature | Number:Temperature | The current temperature reading of the thermostat |
| humidity | Number:Dimensionless | The current humidity reading of the thermostat (CT80 only) |
| mode | Number | The current operating mode of the HVAC system |
| fan_mode | Number | The current operating mode of the fan |
| program_mode | Number | The program schedule that the thermostat is running (CT80 Rev B only) |
| set_point | Number:Temperature | The current temperature set point of the thermostat |
| status | Number | Indicates the current running status of the HVAC system |
| fan_status | Number | Indicates the current fan status of the HVAC system |
| override | Number | Indicates if the normal program set-point has been manually overridden |
| hold | Switch | Indicates if the current set point temperature is to be held indefinitely |
| remote_temp | Number:Temperature | Override the internal temperature as read by the thermostat's temperature sensor; Set to -1 to return to internal temperature mode |
| day | Number | The current day of the week reported by the thermostat (0 = Monday) |