[somfytahoma] added support for the Shutter thing (#12495)
Signed-off-by: Ondrej Pecta <opecta@gmail.com>
This commit is contained in:
parent
c81506b44d
commit
0c2901f3ed
|
@ -21,6 +21,7 @@ Any home automation system based on the OverKiz API is potentially supported.
|
|||
- awnings (UP, DOWN, STOP control of an awning). IO Homecontrol devices are allowed to set exact position of an awning (0-100%)
|
||||
- windows (UP, DOWN, STOP control of a window). IO Homecontrol devices are allowed to set exact position of a window (0-100%)
|
||||
- pergolas (UP, DOWN, STOP control of a pergola). IO Homecontrol devices are allowed to set exact position of a pergola (0-100%)
|
||||
- shutters (OPEN, CLOSE, STOP control of a shutter)
|
||||
- on/off switches (connected by RTS, IO protocol or supported by USB stick - z-wave, enocean, ..)
|
||||
- light switches (similar to on/off)
|
||||
- dimmer lights (light switches with intensity setting)
|
||||
|
@ -63,116 +64,116 @@ Please see the example below.
|
|||
|
||||
## Channels
|
||||
|
||||
| Thing | Channel | Note |
|
||||
|-------------------------------------------------------------------------------|---------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
|
||||
| bridge | N.A | bridge does not expose any channel |
|
||||
| gateway | status | status of your gateway |
|
||||
| gateway | scenarios | used to run the scenarios defined in the cloud portal |
|
||||
| gate | gate_command | used for controlling your gate (open, close, stop, pedestrian) |
|
||||
| gate | gate_state | get state of your gate (open, closed, pedestrian) |
|
||||
| gate | gate_position | get position (0-100%) of your gate (where supported) |
|
||||
| roller shutter, screen, venetian blind, garage door, awning, pergola, curtain | control | device controller which reacts to commands UP/DOWN/ON/OFF/OPEN/CLOSE/MY/STOP + closure 0-100 |
|
||||
| window | control | device controller which reacts to commands UP/DOWN/ON/OFF/OPEN/CLOSE/STOP + closure 0-100 |
|
||||
| silent roller shutter | silent_control | similar to control channel but in silent mode |
|
||||
| venetian blind, adjustable slats roller shutter, bioclimatic pergola | orientation | percentual orientation of the blind's slats, it can have value 0-100. For IO Homecontrol devices only (non RTS) |
|
||||
| venetian blind, adjustable slats roller shutter | closure_orientation | percentual closure and orientation of the blind's slats, it can have value 0-100. For IO Homecontrol devices only (non RTS) |
|
||||
| adjustable slats roller shutter | rocker | used for setting the rocker position of the roller shutter, the only position allowing the slats control |
|
||||
| bioclimatic pergola | slats | slats state (open/closed) |
|
||||
| bioclimatic pergola | pergola_command | used for controlling biclimatic pergola (closeSlats, openSlats, stop) |
|
||||
| action group | execute_action | switch which reacts to ON command and triggers the predefined Tahoma action |
|
||||
| onoff, light | switch | reacts to standard ON/OFF commands |
|
||||
| dimmer light | light_intensity | sets/gets intensity of the dimmer light or ON/OFF |
|
||||
| smoke sensor, occupancy sensor, contact sensor, water sensor & rain sensor | contact | normal value is CLOSE, changes to OPEN when detection triggered |
|
||||
| smoke sensor, occupancy sensor, contact sensor & water sensor | sensor_defect | indicates the health of the sensor (dead, lowBatter, maintenanceRequired, noDefect) |
|
||||
| smoke sensor | radio_battery | maintenance radio part battery state (low, normal) |
|
||||
| smoke sensor | sensor_battery | maintenance sensor part battery state (absence, low, normal) |
|
||||
| smoke sensor | short_check | triggering the smoke sensor's short check |
|
||||
| smoke sensor | long_check | triggering the smoke sensor's long check |
|
||||
| light sensor | luminance | light luminance value in luxes |
|
||||
| electricity sensor | energy_consumption | energy consumption value in watts |
|
||||
| humidity sensor | humidity | current relative humidity |
|
||||
| dock | battery_status | indicates running on battery (yes/no) |
|
||||
| dock | battery_level | remaining battery percentage |
|
||||
| dock | siren_status | used for controlling and getting siren state (on, off, cyclic) |
|
||||
| dock | short_beep | testing of dock's siren - short beep |
|
||||
| dock | long_beep | testing of dock's siren - long beep |
|
||||
| siren | battery | battery level full/low/normal/verylow |
|
||||
| siren | onoff | controlling siren status ON/OFF |
|
||||
| siren | memorized_volume | setting memorized volume (normal/highest) |
|
||||
| pod | cyclic_button | pod cyclic button state |
|
||||
| pod | battery_status | pod battery status state |
|
||||
| pod | lighting_led_pod_mode | lighting LED pod mod state |
|
||||
| interior alarm | alarm_command | used for sending commands to Somfy alarm device |
|
||||
| interior alarm | intrusion_control | used for alarm external intrusion controlling |
|
||||
| interior alarm, myfox alarm | alarm_state | state of the Somfy alarm |
|
||||
| interior alarm | target_alarm_state | target state of the Somfy alarm |
|
||||
| interior alarm, myfox alarm | intrusion_state | intrusion state of the Somfy alarm |
|
||||
| external alarm | active_zones_state | state of external alarm active zones |
|
||||
| door lock | lock | switch representing unlocked/locked state |
|
||||
| door lock | open | switch representing open/close state |
|
||||
| on/off heating system | target_heating_level | target heating level (off, eco, comfort, frostprotection) |
|
||||
| heating system | current_temperature | current temperature of the heating system |
|
||||
| heating system | current_state | current state of the heating system |
|
||||
| heating system, valve heating system, thermostat | target_temperature | target temperature of the heating system |
|
||||
| heating system, valve heating system, thermostat | battery_level | battery level of the heating system |
|
||||
| valve heating system, thermostat | derogation_heating_mode | derogation heating mode of the thermostat (away, freeze, manual, ...) |
|
||||
| valve heating system, thermostat | derogated_target_temperature | target temperature of the heating system |
|
||||
| valve heating system | current_heating_mode | current heating mode of the thermostatic valve |
|
||||
| valve heating system | open_closed_valve | current open/closed state of the thermostatic valve |
|
||||
| valve heating system | operating mode | operating mode of the thermostatic valve |
|
||||
| thermostat | heating_mode | standard heating mode of the thermostat (away, freeze, manual, ...) |
|
||||
| thermostat | derogation_activation | derogation activation state (inactive, active) |
|
||||
| exterior heating system | heating_level | heating level of the exterior heating system or ON/OFF |
|
||||
| temperature sensor | temperature | temperature reported by the sensor |
|
||||
| myfox camera, myfox alarm | cloud_status | cloud connection status |
|
||||
| myfox camera | shutter | controlling of the camera shutter |
|
||||
| myfox alarm | myfox_alarm_command | used for sending commands to Somfy Myfox alarm device |
|
||||
| waterheatersystem | middlewater_temperature | Number:Temperature indicating the temperature of the water at the middle of the heater |
|
||||
| waterheatersystem | boost_mode | Switch allowing to enable or disable the booster. When switching to ON, by default, the Boost duration will be set for 1 day. |
|
||||
| waterheatersystem | away_mode | Defines if away mode is On or Off (no water heating) |
|
||||
| waterheatersystem | away_mode_duration | Defines if away mode the duration in days. |
|
||||
| waterheatersystem | boost_mode_duration | The duration of the Boost mode in days. Valid from 1 to 7. |
|
||||
| waterheatersystem | power_heatpump | Current consumption/power of the heatpump in Watts. |
|
||||
| waterheatersystem | power_heatelec | Current consumption/power of the electric resistance in Watts. |
|
||||
| waterheatersystem | showers | Virtual channel, representing the number of desired showers - between 3 to 5. It actually switches the desired temperature to 50.0, 54.5 or 62.0 Celcius degrees. Please note that in ECO mode, only 3 and 4 showers are allowed. |
|
||||
| waterheatersystem | heat_pump_operating_time | Number of hours the heatpump has been operating |
|
||||
| waterheatersystem | electric_booster_operating_time | number of hours the electric booster has been operating. |
|
||||
| waterheatersystem | mode | The current mode of the boiler. Can be: autoMode / manualEcoInactive / manualEcoActive |
|
||||
| waterheatersystem | target_temperature | Water target temperature in degrees. Read only. Temperature desired is managed through mode and showers channels. |
|
||||
| hitachi (yutaki) air to water heating zone, dhw, main component | alarm_number | error number in case of malfunction |
|
||||
| hitachi (yutaki) air to water heating zone | circuit_control | controls the air-to-water-component (Run, Stop) |
|
||||
| hitachi (yutaki) air to water heating zone | circuit_status | actual state of the air-to-water-component (Run, Stop) |
|
||||
| hitachi (yutaki) air to water heating zone | holiday_mode | switch to activate the holiday mode |
|
||||
| hitachi (yutaki) air to water heating zone | yutaki_mode | actual mode of the heat pump (Eco, Comfort) |
|
||||
| hitachi (yutaki) air to water heating zone | yutaki_target_mode | sets the mode of the heat pump (Eco, Comfort) |
|
||||
| hitachi (yutaki) air to water heating zone | zone_mode | sets the zone mode (Auto, Manual) |
|
||||
| hitachi (yutaki) domestic hot water | anti_legionella | controls the anti legionella mode (Run, Stop) |
|
||||
| hitachi (yutaki) domestic hot water | anti_legionella_temp | controls the anti legionella temperature |
|
||||
| hitachi (yutaki) domestic hot water | target_boost_mode | controls the boost mode (No request, Enabled, Disabled) |
|
||||
| hitachi (yutaki) domestic hot water | boost_mode | boost mode status (Enabled, Disabled) |
|
||||
| hitachi (yutaki) domestic hot water | dhw | controls the hot water tank (Run, Stop) |
|
||||
| hitachi (yutaki) domestic hot water | dhw_mode | controls the dhw mode (Standard, High demand) |
|
||||
| hitachi (yutaki) domestic hot water | dhw_setting_temp | controls the target temperature for hot water |
|
||||
| hitachi (yutaki) domestic hot water | dhw_temp | current temperature of hot water |
|
||||
| hitachi (yutaki) air to water main component | auto_manu_mode | controls auto/manual mode (Auto, Manual) |
|
||||
| hitachi (yutaki) air to water main component | block_menu_control | controls the block menu (No, Block) |
|
||||
| hitachi (yutaki) air to water main component | comm_alarm_bit_status | alarm bit status (No, Yes) |
|
||||
| hitachi (yutaki) air to water main component | compressor_running_current | stage of the current compressor running (0, 0.1, 0.2, 0.3, 0.4) |
|
||||
| hitachi (yutaki) air to water main component | eco_mode_offset | offset for the ECO-Mode |
|
||||
| hitachi (yutaki) air to water main component | eco_mode_target_offset | controls the offset for the ECO-Mode (0-10 degrees) |
|
||||
| hitachi (yutaki) air to water main component | liquid_temp | current liquid temperature |
|
||||
| hitachi (yutaki) air to water main component | liquid_temp_thmi | current liquid temperature THMI |
|
||||
| hitachi (yutaki) air to water main component | operation | current operation state (Alarm, Off, Heat/Cool thermo on, Heat/Cool thermo off, DHW off, Heat/Cool demand off, Swp off) |
|
||||
| hitachi (yutaki) air to water main component | outdoor_temp | current outdoor temperature |
|
||||
| hitachi (yutaki) air to water main component | space_mode | controls space mode (Eco, Comfort) |
|
||||
| hitachi (yutaki) air to water main component | unit_control | controls unit (Run, Stop) |
|
||||
| hitachi (yutaki) air to water main component | unit_mode_control | controls unit mode (Heat, Cool) |
|
||||
| hitachi (yutaki) air to water main component | unit_mode_status | unit mode state (Heat, Cool) |
|
||||
| hitachi (yutaki) air to water main component | water_inlet_temp | current water inlet temperature |
|
||||
| hitachi (yutaki) air to water main component | water_outlet_temp | current water outlet temperature |
|
||||
| hitachi (yutaki) air to water main component | water_outlet_hp_temp | current water outlet hp temperature |
|
||||
| hitachi (yutaki) air to water main component | water_temp_setting | target heating water temperature |
|
||||
| hitachi (yutaki) air to water main component | yutaki_operating_mode | yutaki operating mode (Auto, Holidays, Normal, Timer) |
|
||||
| Thing | Channel | Note |
|
||||
|------------------------------------------------------------------------------------|---------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
|
||||
| bridge | N.A | bridge does not expose any channel |
|
||||
| gateway | status | status of your gateway |
|
||||
| gateway | scenarios | used to run the scenarios defined in the cloud portal |
|
||||
| gate | gate_command | used for controlling your gate (open, close, stop, pedestrian) |
|
||||
| gate | gate_state | get state of your gate (open, closed, pedestrian) |
|
||||
| gate | gate_position | get position (0-100%) of your gate (where supported) |
|
||||
| roller shutter, shutter, screen, ven. blind, garage door, awning, pergola, curtain | control | device controller which reacts to commands UP/DOWN/ON/OFF/OPEN/CLOSE/MY/STOP + closure 0-100 |
|
||||
| window | control | device controller which reacts to commands UP/DOWN/ON/OFF/OPEN/CLOSE/STOP + closure 0-100 |
|
||||
| silent roller shutter | silent_control | similar to control channel but in silent mode |
|
||||
| venetian blind, adjustable slats roller shutter, bioclimatic pergola | orientation | percentual orientation of the blind's slats, it can have value 0-100. For IO Homecontrol devices only (non RTS) |
|
||||
| venetian blind, adjustable slats roller shutter | closure_orientation | percentual closure and orientation of the blind's slats, it can have value 0-100. For IO Homecontrol devices only (non RTS) |
|
||||
| adjustable slats roller shutter | rocker | used for setting the rocker position of the roller shutter, the only position allowing the slats control |
|
||||
| bioclimatic pergola | slats | slats state (open/closed) |
|
||||
| bioclimatic pergola | pergola_command | used for controlling biclimatic pergola (closeSlats, openSlats, stop) |
|
||||
| action group | execute_action | switch which reacts to ON command and triggers the predefined Tahoma action |
|
||||
| onoff, light | switch | reacts to standard ON/OFF commands |
|
||||
| dimmer light | light_intensity | sets/gets intensity of the dimmer light or ON/OFF |
|
||||
| smoke sensor, occupancy sensor, contact sensor, water sensor & rain sensor | contact | normal value is CLOSE, changes to OPEN when detection triggered |
|
||||
| smoke sensor, occupancy sensor, contact sensor & water sensor | sensor_defect | indicates the health of the sensor (dead, lowBatter, maintenanceRequired, noDefect) |
|
||||
| smoke sensor | radio_battery | maintenance radio part battery state (low, normal) |
|
||||
| smoke sensor | sensor_battery | maintenance sensor part battery state (absence, low, normal) |
|
||||
| smoke sensor | short_check | triggering the smoke sensor's short check |
|
||||
| smoke sensor | long_check | triggering the smoke sensor's long check |
|
||||
| light sensor | luminance | light luminance value in luxes |
|
||||
| electricity sensor | energy_consumption | energy consumption value in watts |
|
||||
| humidity sensor | humidity | current relative humidity |
|
||||
| dock | battery_status | indicates running on battery (yes/no) |
|
||||
| dock | battery_level | remaining battery percentage |
|
||||
| dock | siren_status | used for controlling and getting siren state (on, off, cyclic) |
|
||||
| dock | short_beep | testing of dock's siren - short beep |
|
||||
| dock | long_beep | testing of dock's siren - long beep |
|
||||
| siren | battery | battery level full/low/normal/verylow |
|
||||
| siren | onoff | controlling siren status ON/OFF |
|
||||
| siren | memorized_volume | setting memorized volume (normal/highest) |
|
||||
| pod | cyclic_button | pod cyclic button state |
|
||||
| pod | battery_status | pod battery status state |
|
||||
| pod | lighting_led_pod_mode | lighting LED pod mod state |
|
||||
| interior alarm | alarm_command | used for sending commands to Somfy alarm device |
|
||||
| interior alarm | intrusion_control | used for alarm external intrusion controlling |
|
||||
| interior alarm, myfox alarm | alarm_state | state of the Somfy alarm |
|
||||
| interior alarm | target_alarm_state | target state of the Somfy alarm |
|
||||
| interior alarm, myfox alarm | intrusion_state | intrusion state of the Somfy alarm |
|
||||
| external alarm | active_zones_state | state of external alarm active zones |
|
||||
| door lock | lock | switch representing unlocked/locked state |
|
||||
| door lock | open | switch representing open/close state |
|
||||
| on/off heating system | target_heating_level | target heating level (off, eco, comfort, frostprotection) |
|
||||
| heating system | current_temperature | current temperature of the heating system |
|
||||
| heating system | current_state | current state of the heating system |
|
||||
| heating system, valve heating system, thermostat | target_temperature | target temperature of the heating system |
|
||||
| heating system, valve heating system, thermostat | battery_level | battery level of the heating system |
|
||||
| valve heating system, thermostat | derogation_heating_mode | derogation heating mode of the thermostat (away, freeze, manual, ...) |
|
||||
| valve heating system, thermostat | derogated_target_temperature | target temperature of the heating system |
|
||||
| valve heating system | current_heating_mode | current heating mode of the thermostatic valve |
|
||||
| valve heating system | open_closed_valve | current open/closed state of the thermostatic valve |
|
||||
| valve heating system | operating mode | operating mode of the thermostatic valve |
|
||||
| thermostat | heating_mode | standard heating mode of the thermostat (away, freeze, manual, ...) |
|
||||
| thermostat | derogation_activation | derogation activation state (inactive, active) |
|
||||
| exterior heating system | heating_level | heating level of the exterior heating system or ON/OFF |
|
||||
| temperature sensor | temperature | temperature reported by the sensor |
|
||||
| myfox camera, myfox alarm | cloud_status | cloud connection status |
|
||||
| myfox camera | shutter | controlling of the camera shutter |
|
||||
| myfox alarm | myfox_alarm_command | used for sending commands to Somfy Myfox alarm device |
|
||||
| waterheatersystem | middlewater_temperature | Number:Temperature indicating the temperature of the water at the middle of the heater |
|
||||
| waterheatersystem | boost_mode | Switch allowing to enable or disable the booster. When switching to ON, by default, the Boost duration will be set for 1 day. |
|
||||
| waterheatersystem | away_mode | Defines if away mode is On or Off (no water heating) |
|
||||
| waterheatersystem | away_mode_duration | Defines if away mode the duration in days. |
|
||||
| waterheatersystem | boost_mode_duration | The duration of the Boost mode in days. Valid from 1 to 7. |
|
||||
| waterheatersystem | power_heatpump | Current consumption/power of the heatpump in Watts. |
|
||||
| waterheatersystem | power_heatelec | Current consumption/power of the electric resistance in Watts. |
|
||||
| waterheatersystem | showers | Virtual channel, representing the number of desired showers - between 3 to 5. It actually switches the desired temperature to 50.0, 54.5 or 62.0 Celcius degrees. Please note that in ECO mode, only 3 and 4 showers are allowed. |
|
||||
| waterheatersystem | heat_pump_operating_time | Number of hours the heatpump has been operating |
|
||||
| waterheatersystem | electric_booster_operating_time | number of hours the electric booster has been operating. |
|
||||
| waterheatersystem | mode | The current mode of the boiler. Can be: autoMode / manualEcoInactive / manualEcoActive |
|
||||
| waterheatersystem | target_temperature | Water target temperature in degrees. Read only. Temperature desired is managed through mode and showers channels. |
|
||||
| hitachi (yutaki) air to water heating zone, dhw, main component | alarm_number | error number in case of malfunction |
|
||||
| hitachi (yutaki) air to water heating zone | circuit_control | controls the air-to-water-component (Run, Stop) |
|
||||
| hitachi (yutaki) air to water heating zone | circuit_status | actual state of the air-to-water-component (Run, Stop) |
|
||||
| hitachi (yutaki) air to water heating zone | holiday_mode | switch to activate the holiday mode |
|
||||
| hitachi (yutaki) air to water heating zone | yutaki_mode | actual mode of the heat pump (Eco, Comfort) |
|
||||
| hitachi (yutaki) air to water heating zone | yutaki_target_mode | sets the mode of the heat pump (Eco, Comfort) |
|
||||
| hitachi (yutaki) air to water heating zone | zone_mode | sets the zone mode (Auto, Manual) |
|
||||
| hitachi (yutaki) domestic hot water | anti_legionella | controls the anti legionella mode (Run, Stop) |
|
||||
| hitachi (yutaki) domestic hot water | anti_legionella_temp | controls the anti legionella temperature |
|
||||
| hitachi (yutaki) domestic hot water | target_boost_mode | controls the boost mode (No request, Enabled, Disabled) |
|
||||
| hitachi (yutaki) domestic hot water | boost_mode | boost mode status (Enabled, Disabled) |
|
||||
| hitachi (yutaki) domestic hot water | dhw | controls the hot water tank (Run, Stop) |
|
||||
| hitachi (yutaki) domestic hot water | dhw_mode | controls the dhw mode (Standard, High demand) |
|
||||
| hitachi (yutaki) domestic hot water | dhw_setting_temp | controls the target temperature for hot water |
|
||||
| hitachi (yutaki) domestic hot water | dhw_temp | current temperature of hot water |
|
||||
| hitachi (yutaki) air to water main component | auto_manu_mode | controls auto/manual mode (Auto, Manual) |
|
||||
| hitachi (yutaki) air to water main component | block_menu_control | controls the block menu (No, Block) |
|
||||
| hitachi (yutaki) air to water main component | comm_alarm_bit_status | alarm bit status (No, Yes) |
|
||||
| hitachi (yutaki) air to water main component | compressor_running_current | stage of the current compressor running (0, 0.1, 0.2, 0.3, 0.4) |
|
||||
| hitachi (yutaki) air to water main component | eco_mode_offset | offset for the ECO-Mode |
|
||||
| hitachi (yutaki) air to water main component | eco_mode_target_offset | controls the offset for the ECO-Mode (0-10 degrees) |
|
||||
| hitachi (yutaki) air to water main component | liquid_temp | current liquid temperature |
|
||||
| hitachi (yutaki) air to water main component | liquid_temp_thmi | current liquid temperature THMI |
|
||||
| hitachi (yutaki) air to water main component | operation | current operation state (Alarm, Off, Heat/Cool thermo on, Heat/Cool thermo off, DHW off, Heat/Cool demand off, Swp off) |
|
||||
| hitachi (yutaki) air to water main component | outdoor_temp | current outdoor temperature |
|
||||
| hitachi (yutaki) air to water main component | space_mode | controls space mode (Eco, Comfort) |
|
||||
| hitachi (yutaki) air to water main component | unit_control | controls unit (Run, Stop) |
|
||||
| hitachi (yutaki) air to water main component | unit_mode_control | controls unit mode (Heat, Cool) |
|
||||
| hitachi (yutaki) air to water main component | unit_mode_status | unit mode state (Heat, Cool) |
|
||||
| hitachi (yutaki) air to water main component | water_inlet_temp | current water inlet temperature |
|
||||
| hitachi (yutaki) air to water main component | water_outlet_temp | current water outlet temperature |
|
||||
| hitachi (yutaki) air to water main component | water_outlet_hp_temp | current water outlet hp temperature |
|
||||
| hitachi (yutaki) air to water main component | water_temp_setting | target heating water temperature |
|
||||
| hitachi (yutaki) air to water main component | yutaki_operating_mode | yutaki operating mode (Auto, Holidays, Normal, Timer) |
|
||||
|
||||
To run a scenario inside a rule for example, the ID of the scenario will be required.
|
||||
You can list all the scenarios IDs with the following console command: `somfytahoma <bridgeUID> scenarios`.
|
||||
|
|
|
@ -50,6 +50,9 @@ public class SomfyTahomaBindingConstants {
|
|||
// Uno Roller Shutter
|
||||
public static final ThingTypeUID THING_TYPE_ROLLERSHUTTER_UNO = new ThingTypeUID(BINDING_ID, "rollershutter_uno");
|
||||
|
||||
// Shutter
|
||||
public static final ThingTypeUID THING_TYPE_SHUTTER = new ThingTypeUID(BINDING_ID, "shutter");
|
||||
|
||||
// Screen
|
||||
public static final ThingTypeUID THING_TYPE_SCREEN = new ThingTypeUID(BINDING_ID, "screen");
|
||||
|
||||
|
@ -182,7 +185,7 @@ public class SomfyTahomaBindingConstants {
|
|||
public static final String STATUS = "status";
|
||||
public static final String SCENARIOS = "scenarios";
|
||||
|
||||
// Roller shutter, Awning, Screen, Blind, Garage door, Window, Curtain
|
||||
// Roller shutter, Shutter, Awning, Screen, Blind, Garage door, Window, Curtain
|
||||
public static final String CONTROL = "control";
|
||||
|
||||
// Adjustable slats roller shutter
|
||||
|
@ -445,6 +448,7 @@ public class SomfyTahomaBindingConstants {
|
|||
|
||||
// supported uiClasses
|
||||
public static final String CLASS_ROLLER_SHUTTER = "RollerShutter";
|
||||
public static final String CLASS_SHUTTER = "Shutter";
|
||||
public static final String CLASS_SCREEN = "Screen";
|
||||
public static final String CLASS_VENETIAN_BLIND = "VenetianBlind";
|
||||
public static final String CLASS_EXTERIOR_SCREEN = "ExteriorScreen";
|
||||
|
@ -501,7 +505,7 @@ public class SomfyTahomaBindingConstants {
|
|||
THING_TYPE_WATERSENSOR, THING_TYPE_HUMIDITYSENSOR, THING_TYPE_MYFOX_ALARM, THING_TYPE_THERMOSTAT,
|
||||
THING_TYPE_DIMMER_LIGHT, THING_TYPE_EXTERIOR_HEATING_SYSTEM, THING_TYPE_VALVE_HEATING_SYSTEM,
|
||||
THING_TYPE_BIOCLIMATIC_PERGOLA, THING_TYPE_WATERHEATINGSYSTEM, THING_TYPE_HITACHI_ATWHZ,
|
||||
THING_TYPE_HITACHI_DHW, THING_TYPE_HITACHI_ATWMC, THING_TYPE_RAINSENSOR));
|
||||
THING_TYPE_HITACHI_DHW, THING_TYPE_HITACHI_ATWMC, THING_TYPE_RAINSENSOR, THING_TYPE_SHUTTER));
|
||||
|
||||
// somfy gateways
|
||||
public static Map<Integer, String> gatewayTypes = new HashMap<Integer, String>() {
|
||||
|
|
|
@ -46,6 +46,7 @@ import org.openhab.binding.somfytahoma.internal.handler.SomfyTahomaPergolaHandle
|
|||
import org.openhab.binding.somfytahoma.internal.handler.SomfyTahomaPodHandler;
|
||||
import org.openhab.binding.somfytahoma.internal.handler.SomfyTahomaRainSensorHandler;
|
||||
import org.openhab.binding.somfytahoma.internal.handler.SomfyTahomaRollerShutterHandler;
|
||||
import org.openhab.binding.somfytahoma.internal.handler.SomfyTahomaShutterHandler;
|
||||
import org.openhab.binding.somfytahoma.internal.handler.SomfyTahomaSilentRollerShutterHandler;
|
||||
import org.openhab.binding.somfytahoma.internal.handler.SomfyTahomaSirenHandler;
|
||||
import org.openhab.binding.somfytahoma.internal.handler.SomfyTahomaSmokeSensorHandler;
|
||||
|
@ -118,6 +119,8 @@ public class SomfyTahomaHandlerFactory extends BaseThingHandlerFactory {
|
|||
return new SomfyTahomaUnoRollerShutterHandler(thing);
|
||||
} else if (thingTypeUID.equals(THING_TYPE_SCREEN) || thingTypeUID.equals(THING_TYPE_EXTERIORSCREEN)) {
|
||||
return new SomfyTahomaRollerShutterHandler(thing);
|
||||
} else if (thingTypeUID.equals(THING_TYPE_SHUTTER)) {
|
||||
return new SomfyTahomaShutterHandler(thing);
|
||||
} else if (thingTypeUID.equals(THING_TYPE_VENETIANBLIND)
|
||||
|| thingTypeUID.equals(THING_TYPE_EXTERIORVENETIANBLIND)) {
|
||||
return new SomfyTahomaVenetianBlindHandler(thing);
|
||||
|
|
|
@ -213,6 +213,10 @@ public class SomfyTahomaItemDiscoveryService extends AbstractDiscoveryService
|
|||
deviceDiscovered(device, THING_TYPE_ROLLERSHUTTER, place);
|
||||
}
|
||||
break;
|
||||
case CLASS_SHUTTER:
|
||||
// widget: DynamicShutter
|
||||
deviceDiscovered(device, THING_TYPE_SHUTTER, place);
|
||||
break;
|
||||
case CLASS_SCREEN:
|
||||
// widget: PositionableTiltedScreen
|
||||
deviceDiscovered(device, THING_TYPE_SCREEN, place);
|
||||
|
@ -223,7 +227,12 @@ public class SomfyTahomaItemDiscoveryService extends AbstractDiscoveryService
|
|||
break;
|
||||
case CLASS_VENETIAN_BLIND:
|
||||
// widget: DynamicVenetianBlind
|
||||
deviceDiscovered(device, THING_TYPE_VENETIANBLIND, place);
|
||||
if (hasCommmand(device, "setOrientation")) {
|
||||
deviceDiscovered(device, THING_TYPE_VENETIANBLIND, place);
|
||||
} else {
|
||||
// simple venetian blind without orientation
|
||||
deviceDiscovered(device, THING_TYPE_SHUTTER, place);
|
||||
}
|
||||
break;
|
||||
case CLASS_WINDOW:
|
||||
// widget: PositionableTiltedWindow
|
||||
|
|
|
@ -0,0 +1,78 @@
|
|||
/**
|
||||
* Copyright (c) 2010-2022 Contributors to the openHAB project
|
||||
*
|
||||
* See the NOTICE file(s) distributed with this work for additional
|
||||
* information.
|
||||
*
|
||||
* This program and the accompanying materials are made available under the
|
||||
* terms of the Eclipse Public License 2.0 which is available at
|
||||
* http://www.eclipse.org/legal/epl-2.0
|
||||
*
|
||||
* SPDX-License-Identifier: EPL-2.0
|
||||
*/
|
||||
package org.openhab.binding.somfytahoma.internal.handler;
|
||||
|
||||
import static org.openhab.binding.somfytahoma.internal.SomfyTahomaBindingConstants.*;
|
||||
|
||||
import org.eclipse.jdt.annotation.NonNullByDefault;
|
||||
import org.eclipse.jdt.annotation.Nullable;
|
||||
import org.openhab.core.library.types.DecimalType;
|
||||
import org.openhab.core.thing.ChannelUID;
|
||||
import org.openhab.core.thing.Thing;
|
||||
import org.openhab.core.types.Command;
|
||||
import org.openhab.core.types.RefreshType;
|
||||
|
||||
/**
|
||||
* The {@link SomfyTahomaShutterHandler} is responsible for handling commands,
|
||||
* which are sent to one of the channels of the shutter thing.
|
||||
*
|
||||
* @author Ondrej Pecta - Initial contribution
|
||||
*/
|
||||
@NonNullByDefault
|
||||
public class SomfyTahomaShutterHandler extends SomfyTahomaBaseThingHandler {
|
||||
|
||||
public SomfyTahomaShutterHandler(Thing thing) {
|
||||
super(thing);
|
||||
}
|
||||
|
||||
@Override
|
||||
public void handleCommand(ChannelUID channelUID, Command command) {
|
||||
super.handleCommand(channelUID, command);
|
||||
if (!CONTROL.equals(channelUID.getId())) {
|
||||
return;
|
||||
}
|
||||
|
||||
if (command instanceof RefreshType) {
|
||||
return;
|
||||
} else {
|
||||
if (command instanceof DecimalType) {
|
||||
sendCommand(toInteger(command) == 0 ? COMMAND_OPEN : COMMAND_CLOSE);
|
||||
} else {
|
||||
// Shutter understands "open", "close" and "stop" commands
|
||||
String cmd = getTahomaCommand(command.toString());
|
||||
if (cmd != null) {
|
||||
sendCommand(cmd);
|
||||
} else {
|
||||
getLogger().debug("unsupported command: {}", command);
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
private @Nullable String getTahomaCommand(String command) {
|
||||
switch (command) {
|
||||
case "OFF":
|
||||
case "DOWN":
|
||||
case "CLOSE":
|
||||
return COMMAND_CLOSE;
|
||||
case "ON":
|
||||
case "UP":
|
||||
case "OPEN":
|
||||
return COMMAND_OPEN;
|
||||
case "STOP":
|
||||
return COMMAND_STOP;
|
||||
default:
|
||||
return null;
|
||||
}
|
||||
}
|
||||
}
|
|
@ -45,6 +45,7 @@ thing-type.somfytahoma.rollershutter.label = Somfy Roller Shutter
|
|||
thing-type.somfytahoma.rollershutter_silent.label = Somfy Silent Roller Shutter
|
||||
thing-type.somfytahoma.rollershutter_uno.label = Somfy Roller Shutter Uno
|
||||
thing-type.somfytahoma.screen.label = Somfy Screen
|
||||
thing-type.somfytahoma.shutter.label = Somfy Shutter
|
||||
thing-type.somfytahoma.siren.label = Somfy Siren
|
||||
thing-type.somfytahoma.smokesensor.label = Somfy Smoke Sensor
|
||||
thing-type.somfytahoma.temperaturesensor.label = Somfy Temperature Sensor
|
||||
|
|
|
@ -0,0 +1,19 @@
|
|||
<?xml version="1.0" encoding="UTF-8"?>
|
||||
<thing:thing-descriptions bindingId="somfytahoma"
|
||||
xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
|
||||
xmlns:thing="https://openhab.org/schemas/thing-description/v1.0.0"
|
||||
xsi:schemaLocation="https://openhab.org/schemas/thing-description/v1.0.0 https://openhab.org/schemas/thing-description-1.0.0.xsd">
|
||||
|
||||
<thing-type id="shutter">
|
||||
<supported-bridge-type-refs>
|
||||
<bridge-type-ref id="bridge"/>
|
||||
</supported-bridge-type-refs>
|
||||
<label>Somfy Shutter</label>
|
||||
<channels>
|
||||
<channel id="control" typeId="control"></channel>
|
||||
</channels>
|
||||
<representation-property>url</representation-property>
|
||||
<config-description-ref uri="thing-type:somfytahoma:device"/>
|
||||
</thing-type>
|
||||
|
||||
</thing:thing-descriptions>
|