[Documentation] Markdown improvements f to m (#13866)
Signed-off-by: Jerome Luckenbach <github@luckenba.ch>
This commit is contained in:
committed by
GitHub
parent
3c236b3103
commit
0e68936663
@@ -33,10 +33,10 @@ There are several settings for an account:
|
||||
|
||||
### Obtaining your API Key
|
||||
|
||||
1. Goto https://developer.husqvarnagroup.cloud/, sign in using your GARDENA smart system account and accept the terms of use
|
||||
2. Create and save a new application via the 'Create application' button. The Redirect URLs do not matter, you can enter what you want (e.g. http://localhost:8080)
|
||||
3. Connect both _Authentication API_ and _GARDENA smart system API_ to your application via the 'Connect new API' button
|
||||
4. Copy the application key to use with this binding as _apiKey_
|
||||
1. Goto <https://developer.husqvarnagroup.cloud/>, sign in using your GARDENA smart system account and accept the terms of use
|
||||
1. Create and save a new application via the 'Create application' button. The Redirect URLs do not matter, you can enter what you want (e.g. <http://localhost:8080>)
|
||||
1. Connect both _Authentication API_ and _GARDENA smart system API_ to your application via the 'Connect new API' button
|
||||
1. Copy the application key to use with this binding as _apiKey_
|
||||
|
||||
## Examples
|
||||
|
||||
@@ -85,7 +85,7 @@ Sensor refresh commands are not yet supported by the Gardena smart system integr
|
||||
|
||||
### Example configuration
|
||||
|
||||
```
|
||||
```java
|
||||
// smart Water Control
|
||||
String WC_Valve_Activity "Valve Activity" { channel="gardena:water_control:home:myWateringComputer:valve#activity" }
|
||||
Number WC_Valve_Duration "Last Watering Duration [%d min]" { channel="gardena:water_control:home:myWateringComputer:valve#duration" }
|
||||
@@ -100,7 +100,7 @@ openhab:status WC_Valve_Activity // returns the current valve activity (CLOSED|
|
||||
|
||||
All channels are read-only, except the command group and the lastUpdate timestamp
|
||||
|
||||
```
|
||||
```shell
|
||||
openhab:send WC_Valve_cmd_Duration.sendCommand(10) // set the duration for the command to 10min
|
||||
openhab:send WC_Valve_cmd_OpenWithDuration.sendCommand(ON) // start watering
|
||||
openhab:send WC_Valve_cmd_CloseValve.sendCommand(ON) // stop any active watering
|
||||
@@ -108,9 +108,11 @@ openhab:send WC_Valve_cmd_CloseValve.sendCommand(ON) // stop any active watering
|
||||
|
||||
If you send a REFRESH command to the last update timestamp (no matter which thing), **ALL** items from **ALL** things are updated
|
||||
|
||||
```
|
||||
```java
|
||||
DateTime LastUpdate "LastUpdate [%1$td.%1$tm.%1$tY %1$tH:%1$tM]" { channel="gardena:water_control:home:myWateringComputer:common#lastUpdate_timestamp" }
|
||||
```
|
||||
|
||||
```shell
|
||||
// refresh ALL items
|
||||
openhab:send LastUpdate REFRESH
|
||||
```
|
||||
@@ -133,31 +135,31 @@ Attempting to force reconnect within the 24 hours causes the call rate to be exc
|
||||
|
||||
If you want to see what's going on in the binding, switch the loglevel to TRACE in the Karaf console
|
||||
|
||||
```
|
||||
```shell
|
||||
log:set TRACE org.openhab.binding.gardena
|
||||
```
|
||||
|
||||
Set the logging back to normal
|
||||
|
||||
```
|
||||
```shell
|
||||
log:set INFO org.openhab.binding.gardena
|
||||
```
|
||||
|
||||
**Notes and known limitations:**
|
||||
**Notes and known limitations:**
|
||||
When the binding sends a command to a device, it communicates only with the Gardena smart system integration API.
|
||||
It has no control over whether the command is sent from the online service via your gateway to the device.
|
||||
It is the same as if you send the command in the Gardena App.
|
||||
|
||||
Schedules, sensor-refresh commands, irrigation control master valve configuration etc. are not supported.
|
||||
This binding relies on the GARDENA smart system integration API.
|
||||
Further API documentation: https://developer.1689.cloud/apis/GARDENA+smart+system+API
|
||||
Further API documentation: <https://developer.1689.cloud/apis/GARDENA+smart+system+API>
|
||||
|
||||
### Troubleshooting
|
||||
|
||||
###Troubleshooting
|
||||
Occasionally it can happen that the API key is no longer valid.
|
||||
|
||||
```
|
||||
```text
|
||||
HTTP protocol violation: Authentication challenge without WWW-Authenticate header
|
||||
```
|
||||
|
||||
If this error message appears in the log file, simply renew or delete/create a new API key as described in 'Obtaining your API Key' and restart openHAB.
|
||||
|
||||
|
||||
Reference in New Issue
Block a user