[Documentation] Markdown improvements f to m (#13866)

Signed-off-by: Jerome Luckenbach <github@luckenba.ch>
This commit is contained in:
Jerome Luckenbach
2022-12-08 21:36:05 +01:00
committed by GitHub
parent 3c236b3103
commit 0e68936663
122 changed files with 3490 additions and 3662 deletions

View File

@@ -19,7 +19,7 @@ If you need to add for multiple brands or multiple different users, add multiple
You need to select a brand and enter the user name and password.
The Polling Interval (in minutes) determines how often the API will be polled for new cars.
The Client ID and Client Secret should not need to be updated.
(However you can register your own app via https://developer.groupe-psa.com/inc/ and use this client information if you wish.)
(However you can register your own app via <https://developer.groupe-psa.com/inc/> and use this client information if you wish.)
### parameters
@@ -29,8 +29,8 @@ The Client ID and Client Secret should not need to be updated.
| userName | None | Yes | The user name for the mypeugot/mycitroen/myds/myopel/myvauxhall website or app. |
| password | None | Yes | The password for the given user. |
| pollingInterval | 60 | No | The Polling Interval (in minutes) determines how often the available vehicles are queried. |
| clientId | | Yes | The Client ID for API access: can normally left at the default value. (see: https://developer.groupe-psa.io/webapi/b2c/quickstart/connect/#article) |
| clientSecret | | Yes | The Client Secret for API access: can normally left at the default value. (see: https://developer.groupe-psa.io/webapi/b2c/quickstart/connect/#article) |
| clientId | | Yes | The Client ID for API access: can normally left at the default value. (see: <https://developer.groupe-psa.io/webapi/b2c/quickstart/connect/#article>) |
| clientSecret | | Yes | The Client Secret for API access: can normally left at the default value. (see: <https://developer.groupe-psa.io/webapi/b2c/quickstart/connect/#article>) |
## Vehicle Configuration
@@ -85,13 +85,13 @@ The Polling Interval and Online Timeout can be adjusted.
| chargingRemainingTime | Number:Time | Time remaining till charged |
| chargingNextDelayedTime | Number:Time | Time till the next charging starts |
Further documentation can be found at: https://developer.groupe-psa.io/webapi/b2c/api-reference/specification/#article
Further documentation can be found at: <https://developer.groupe-psa.io/webapi/b2c/api-reference/specification/#article>
## Full Example
### Things file
```
```java
Bridge groupepsa:bridge:opel "Auto Interface" [
pollingInterval=60,
userName="anonymous@anonymous.email",
@@ -111,7 +111,7 @@ Bridge groupepsa:bridge:opel "Auto Interface" [
### Items file
```
```java
Group Auto
Number:ElectricCurrent Auto_Aux_Current "Auxillliary Battery Current [%.1f %unit%]" (Auto) ["Measurement","Current"] {channel="groupepsa:vehicle:opel:zafira:battery#current"}