@@ -21,7 +21,7 @@ This binding uses TCP/IP to access the LCN bus via the software LCN-PCHK (Window
|
||||
|
||||
### Thing: LCN Module
|
||||
|
||||
Any LCN module that should be controlled or visualized, need to be added to openHAB as a *Thing*.
|
||||
Any LCN module that should be controlled or visualized, need to be added to openHAB as a _Thing_.
|
||||
|
||||
LCN modules with firmware versions 120612 (2008), 170602 (2013) and 1F080A (2021) were tested with this binding.
|
||||
Modules with older and newer firmware should work, too.
|
||||
@@ -40,9 +40,9 @@ See [Discover LCN Modules](#discover-lcn-modules).
|
||||
### Bridge: LCN PCK Gateway
|
||||
|
||||
PCK is the protocol spoken over TCP/IP with a PCK gateway to communicate with the LCN bus.
|
||||
Examples for PCK gateways are the *LCN-PCHK* software running on Windows or Linux and the DIN rail mounting device *LCN-VISU*.
|
||||
Examples for PCK gateways are the _LCN-PCHK_ software running on Windows or Linux and the DIN rail mounting device _LCN-VISU_.
|
||||
|
||||
For each LCN bus, interfaced to openHAB, a PCK gateway needs to be added to openHAB as a *Thing*.
|
||||
For each LCN bus, interfaced to openHAB, a PCK gateway needs to be added to openHAB as a _Thing_.
|
||||
|
||||
Several PCK gateways can be added to openHAB to control multiple LCN busses in distinct locations.
|
||||
|
||||
@@ -72,12 +72,12 @@ Please see the following LCN-PRO screenshot to determine the dimmer output resol
|
||||
|
||||
### Thing: LCN Group
|
||||
|
||||
LCN modules can be assigned to groups with the programming software *LCN-PRO*.
|
||||
LCN modules can be assigned to groups with the programming software _LCN-PRO_.
|
||||
|
||||
To send commands to an LCN group, the group needs to be added to openHAB as a *Thing*.
|
||||
To send commands to an LCN group, the group needs to be added to openHAB as a _Thing_.
|
||||
|
||||
One LCN module within the group is used to represent the status of the whole group.
|
||||
For example, when a Dimmer Output is controlled via a LCN group *Thing*, openHAB will always visualize the state of the Dimmer Output of the chosen module. The states of the other modules in the group are ignored for visualization.
|
||||
For example, when a Dimmer Output is controlled via a LCN group _Thing_, openHAB will always visualize the state of the Dimmer Output of the chosen module. The states of the other modules in the group are ignored for visualization.
|
||||
|
||||
Thing Type ID: `group`
|
||||
|
||||
@@ -87,7 +87,7 @@ Thing Type ID: `group`
|
||||
| `moduleId` | The module ID of any module in the group. The state of this module is used for visualization of the group as representative for all modules. | Integer | Yes |
|
||||
| `segmentId` | The segment ID of all modules in this group (0 if no segments are present) | Integer | Yes |
|
||||
|
||||
The `groupId` must match the previously configured group number in the programming software *LCN-PRO*.
|
||||
The `groupId` must match the previously configured group number in the programming software _LCN-PRO_.
|
||||
|
||||
## Discovery
|
||||
|
||||
@@ -97,7 +97,7 @@ Basic data like the names of all LCN modules in the bus, can be read out by open
|
||||
|
||||
If not all LCN modules get listed on the first run, click on the refresh button to start another scan.
|
||||
|
||||
When adding a module by discovery, the new *Thing*'s UID will be a combination of segment and module id using the following format:
|
||||
When adding a module by discovery, the new _Thing_'s UID will be a combination of segment and module id using the following format:
|
||||
`S<segmentId>M<moduleId>` where `segmentId` and `moduleId` are formatted as three-digit numbers with leading zeros.
|
||||
|
||||
### Discover PCK Gateways
|
||||
@@ -106,8 +106,8 @@ PCK gateways in the LAN can be found automatically by openHAB. This is done by U
|
||||
The discovery works only if the firewall of the PCK gateway is not configured too strictly.
|
||||
This means on Windows PCs, that the network must be configured as 'private' and not as 'public'.
|
||||
Also, some network switches may block multicast packets.
|
||||
Unfortunately, *LCN-PCHK* listens only on the first network interface of the computer for discovery packets.
|
||||
If your PCK gateway has multiple network interfaces, *LCN-PCHK* may listen on the wrong interface and fails to respond to the discovery request.
|
||||
Unfortunately, _LCN-PCHK_ listens only on the first network interface of the computer for discovery packets.
|
||||
If your PCK gateway has multiple network interfaces, _LCN-PCHK_ may listen on the wrong interface and fails to respond to the discovery request.
|
||||
|
||||
Discovery has successfully been tested with LCN-PCHK 3.2.2 running on a Raspberry Pi with Raspbian and openHAB running on Windows 10.
|
||||
|
||||
@@ -116,12 +116,12 @@ If discovery fails, you can add a PCK gateway manually. See [Thing: PCK Gateway]
|
||||
Please be aware that you **have to configure** username, password and the dimmer output resolution also if you use discovery.
|
||||
See [Thing: PCK Gateway](#bridge-lcn-pck-gateway).
|
||||
|
||||
When adding a PCK gateway by discovery, the new *Thing*'s UID is the MAC address of the device, running the PCK gateway.
|
||||
When adding a PCK gateway by discovery, the new _Thing_'s UID is the MAC address of the device, running the PCK gateway.
|
||||
|
||||
## Supported LCN Features and openHAB Channels
|
||||
|
||||
The following table lists all features of LCN and their mappings to openHAB Channels.
|
||||
These Channels are available for the *Thing* LCN module (`module`).
|
||||
These Channels are available for the _Thing_ LCN module (`module`).
|
||||
LCN group (`group`) has the same Channels, except status-only Channels like binary sensors or transponders.
|
||||
The PCK gateway (`pckGateway`) has no Channels.
|
||||
|
||||
@@ -162,7 +162,7 @@ If a special command is needed, the [Hit Key](#hit-key) action (German: "Sende T
|
||||
| Remote Control | Fernbedienung | code#remotecontrolkey | | Trigger | Receive commands from remote control |
|
||||
| Access Control | Zutrittskontrolle | code#remotecontrolcode | | Trigger | Receive serial numbers from remote control |
|
||||
| Remote Control Battery Low | Fernbedienung Batterie schwach | code#remotecontrolbatterylow | | Trigger | Triggered when the sending remote control has a low battery |
|
||||
| Host Command (Send Keys) | Kommando an Host (Sende Tasten) | hostcommand#sendKeys | - | Trigger | Receive *send keys* command from LCN module |
|
||||
| Host Command (Send Keys) | Kommando an Host (Sende Tasten) | hostcommand#sendKeys | - | Trigger | Receive _send keys_ command from LCN module |
|
||||
| Operating Hours Counter Outputs | Betriebsstundenzähler Ausgänge | operatinghourscounter | output[1-4] | Number:Time | Visualize Operating Hours Counter for outputs |
|
||||
| Operating Hours Counter Outputs (rel. Work) | Betriebsstundenzähler Ausgänge (rel. Arbeit) | operatinghourscounter | outputrelativework[1-4] | Number:Time | Visualize Operating Hours Counter for outputs (relative work) |
|
||||
| Operating Hours Counter Relays | Betriebsstundenzähler Relais | operatinghourscounter | relay[1-8] | Number:Time | Visualize Operating Hours Counter for relays |
|
||||
@@ -194,9 +194,9 @@ If a special command is needed, the [Hit Key](#hit-key) action (German: "Sende T
|
||||
| Set S0 Counters | S0-Zähler setzen | - | - | - | Not implemented |
|
||||
| Status Command | Statuskommandos | - | - | - | Not implemented |
|
||||
|
||||
*Notes:*
|
||||
_Notes:_
|
||||
|
||||
- **For some *Channel*s (e.g. temperature) a unit should be configured in the channel configuration.** By default the native LCN value is used.
|
||||
- **For some _Channel_s (e.g. temperature) a unit should be configured in the channel configuration.** By default the native LCN value is used.
|
||||
- S0 counter Channels need to be the pulses per kWh configured. If the value is left blank, a default value of 1000 pulses/kWh is set.
|
||||
- When setting a variable via openHAB, the variable must be configured as counter in LCN-PRO. The variable must be set initially by the module after power up.
|
||||
- The Rollershutter Channels provide the boolean parameter `invertUpDown`, which can be set to 'true' if the Up/Down wires are interchanged.
|
||||
@@ -205,11 +205,11 @@ If a special command is needed, the [Hit Key](#hit-key) action (German: "Sende T
|
||||
### Transponder/Fingerprints
|
||||
|
||||
LCN transponder readers or fingerprint readers can be integrated in openHAB e.g. for access control.
|
||||
The transponder function must be enabled in the module's I-port properties within *LCN-PRO*.
|
||||
The transponder function must be enabled in the module's I-port properties within _LCN-PRO_.
|
||||
|
||||
Example: When the transponder card with the ID "12ABCD" is seen by the reader connected to LCN module "S000M011", the item "M10_Relay7" is switched on:
|
||||
|
||||
```
|
||||
```java
|
||||
rule "My Transponder"
|
||||
when
|
||||
Channel "lcn:module:b827ebfea4bb:S000M011:code#transponder" triggered "12ABCD"
|
||||
@@ -220,7 +220,7 @@ end
|
||||
|
||||
Example: When fingerprint with ID "AFFE12" is seen by reader connected to LCN module "S000M011", the item "M10_Relay7" is switched on:
|
||||
|
||||
```
|
||||
```java
|
||||
rule "My Fingerprint"
|
||||
when
|
||||
Channel "lcn:module:b827ebfea4bb:S000M011:code#fingerprint" triggered "AFFE12"
|
||||
@@ -233,18 +233,18 @@ end
|
||||
|
||||
LCN modules can send commands to openHAB, e.g. by pressing a physical LCN key.
|
||||
The command must be programmed into the LCN module by the programming software LCN-PRO.
|
||||
Only the *send keys* command (German: "Sende Tasten") is supported.
|
||||
Only the _send keys_ command (German: "Sende Tasten") is supported.
|
||||
|
||||
Program a command to a key of an LCN module via LCN-PRO.
|
||||
When LCN-PRO asks you for the target address, don't select any module, but manually enter the PCK host ID, configured within PCHK (default: 4).
|
||||
Select the *send keys* command and "A-C (former command)", as PCHK 3.2.2 only supports the old command.
|
||||
Select the _send keys_ command and "A-C (former command)", as PCHK 3.2.2 only supports the old command.
|
||||
Then, select any key(s) you want to send to openHAB. These can be freely chosen, as they are only evaluated by openHAB.
|
||||
|
||||

|
||||
|
||||
The following rule can be used to trigger any action:
|
||||
|
||||
```
|
||||
```java
|
||||
rule "Module 12 sent A1 Hit"
|
||||
when
|
||||
Channel "lcn:module:b827ebfea4bb:S000M012:hostcommand#sendKeys" triggered "A1:HIT"
|
||||
@@ -253,7 +253,7 @@ then
|
||||
end
|
||||
```
|
||||
|
||||
`A1` is the key of the *send keys* command, programmed by LCN-PRO.
|
||||
`A1` is the key of the _send keys_ command, programmed by LCN-PRO.
|
||||
After the colon, the LCN "hit type" follows: HIT, MAKE or BREAK (German: kurz, lang, los)
|
||||
|
||||
If multiple keys or key tables are programmed in a single "send keys" command, multiple triggers will be executed.
|
||||
@@ -264,15 +264,15 @@ Simply press the physical button at the module for testing.
|
||||
|
||||
### Remote Control
|
||||
|
||||
To evaluate commands from LCN remote controls (e.g. LCN-RT or LCN-RT16), the module's I-port behavior must be configured as "IR access control" within *LCN-PRO*:
|
||||
To evaluate commands from LCN remote controls (e.g. LCN-RT or LCN-RT16), the module's I-port behavior must be configured as "IR access control" within _LCN-PRO_:
|
||||
|
||||

|
||||
|
||||
#### Remote Control Keys
|
||||
|
||||
The trigger *Channel* `lcn:module:<pckThing>:<moduleThing>:code#remotecontrolkey` can be used to execute commands, when a specific key on a remote control is pressed:
|
||||
The trigger _Channel_ `lcn:module:<pckThing>:<moduleThing>:code#remotecontrolkey` can be used to execute commands, when a specific key on a remote control is pressed:
|
||||
|
||||
```
|
||||
```java
|
||||
rule "Remote Control Key 3 on Layer 1 hit"
|
||||
when
|
||||
Channel "lcn:module:b827ebfea4bb:S000M012:code#remotecontrolkey" triggered "A3:HIT"
|
||||
@@ -287,7 +287,7 @@ end
|
||||
|
||||
The serial number of a remote control can be used for access control via the channel `lcn:module:<pckThing>:<moduleThing>:code#remotecontrolcode`. See the following example:
|
||||
|
||||
```
|
||||
```java
|
||||
rule "Remote Control Key 3 on Layer 1 hit (only executed for serial number AB1234)"
|
||||
when
|
||||
Channel "lcn:module:b827ebfea4bb:S000M012:code#remotecontrolcode" triggered "AB1234:A3:HIT" or
|
||||
@@ -301,24 +301,24 @@ The command will be executed when the remote control button A3 is either pressed
|
||||
|
||||
## Dimmer Outputs with Ramp and Multiple Outputs
|
||||
|
||||
The *output* profile can be used to control multiple dimmer outputs of the *same* module simultaneously or control a dimmer output with a ramp (slowly dimming).
|
||||
The _output_ profile can be used to control multiple dimmer outputs of the _same_ module simultaneously or control a dimmer output with a ramp (slowly dimming).
|
||||
|
||||
The optional *ramp* parameter must be float or integer.
|
||||
The optional _ramp_ parameter must be float or integer.
|
||||
The lowest value is 0.25, which corresponds to 0.25s. The highest value is 486s.
|
||||
When no *ramp* parameter is specified or no profile is configured, the ramp is 0 (behavior like a switch).
|
||||
The ramp parameter is not available for Color *Item*s.
|
||||
When no _ramp_ parameter is specified or no profile is configured, the ramp is 0 (behavior like a switch).
|
||||
The ramp parameter is not available for Color _Item_s.
|
||||
|
||||
```
|
||||
```java
|
||||
// Dim output 2 in 0.25s
|
||||
Switch M10_Output2 {channel="lcn:module:b827ebfea4bb:S000M010:output#2"[profile="lcn:output", ramp=0.25]} // with ramp of 0.25s (smallest value)
|
||||
// Dim output 3 in 486s
|
||||
Dimmer M10_Output3 {channel="lcn:module:b827ebfea4bb:S000M010:output#3"[profile="lcn:output", ramp=486]} // with ramp of 486s (biggest value)
|
||||
```
|
||||
|
||||
The optional parameters *controlAllOutputs* and *controlOutputs12* can be used to control multiple outputs simultaneously.
|
||||
Please note that the combination of these parameters with the *ramp* parameter is limited:
|
||||
The optional parameters _controlAllOutputs_ and _controlOutputs12_ can be used to control multiple outputs simultaneously.
|
||||
Please note that the combination of these parameters with the _ramp_ parameter is limited:
|
||||
|
||||
```
|
||||
```java
|
||||
// Control outputs 1+2 simultaneously. Status of Output 1 is visualized. Only ramps of 0s or 0.25s are supported.
|
||||
Dimmer M10_Outputs12a {channel="lcn:module:b827ebfea4bb:S000M010:output#1"[profile="lcn:output", controlOutputs12=true]}
|
||||
Dimmer M10_Outputs12b {channel="lcn:module:b827ebfea4bb:S000M010:output#1"[profile="lcn:output", controlOutputs12=true, ramp=0.25]}
|
||||
@@ -334,20 +334,20 @@ Actions are special commands that can be sent to LCN modules or LCN groups.
|
||||
|
||||
### Hit Key
|
||||
|
||||
This *Action* virtually hits a key of a key table in an LCN module.
|
||||
This _Action_ virtually hits a key of a key table in an LCN module.
|
||||
Simply spoken, openHAB acts as a push button switch connected to an LCN module.
|
||||
|
||||
This *Action* can be used to execute commands which are not natively supported by this binding.
|
||||
The function can be programmed via the software *LCN-PRO* onto a key in a module's key table.
|
||||
Then, the programmed key can be "hit" by this *Action* and the command will be executed.
|
||||
This _Action_ can be used to execute commands which are not natively supported by this binding.
|
||||
The function can be programmed via the software _LCN-PRO_ onto a key in a module's key table.
|
||||
Then, the programmed key can be "hit" by this _Action_ and the command will be executed.
|
||||
|
||||
When programming a "Hit Key" *Action*, the following parameters need to be set:
|
||||
When programming a "Hit Key" _Action_, the following parameters need to be set:
|
||||
|
||||
*table* - The module's key table: A, B, C or D<br />
|
||||
*key* - The number of the key within the key table: 1-8<br />
|
||||
*action* - The key's action: HIT (German: "kurz"), MAKE ("lang") or BREAK ("los")
|
||||
_table_ - The module's key table: A, B, C or D<br />
|
||||
_key_ - The number of the key within the key table: 1-8<br />
|
||||
_action_ - The key's action: HIT (German: "kurz"), MAKE ("lang") or BREAK ("los")
|
||||
|
||||
```
|
||||
```java
|
||||
rule "Hit key C4 hourly"
|
||||
when
|
||||
Time cron "0 0 * * * ?"
|
||||
@@ -359,20 +359,20 @@ end
|
||||
|
||||
### Dynamic Text
|
||||
|
||||
This *Action* can be used to send custom texts to an LCN-GTxD display.
|
||||
To make this function work, the row of the display has to be configured to allow dynamic text within *LCN-PRO*:
|
||||
This _Action_ can be used to send custom texts to an LCN-GTxD display.
|
||||
To make this function work, the row of the display has to be configured to allow dynamic text within _LCN-PRO_:
|
||||
|
||||

|
||||
|
||||
When programming a "Dynamic Text" *Action*, the following parameters need to be set:
|
||||
When programming a "Dynamic Text" _Action_, the following parameters need to be set:
|
||||
|
||||
*row* - The number of the row in the display: 1-4<br />
|
||||
*text* - The text to be displayed (UTF-8)
|
||||
_row_ - The number of the row in the display: 1-4<br />
|
||||
_text_ - The text to be displayed (UTF-8)
|
||||
|
||||
The length of the text may not exceed 60 bytes of characters.
|
||||
Bear in mind that unicode characters can take more than one byte (e.g. umlauts (äöü) take two bytes).
|
||||
|
||||
```
|
||||
```java
|
||||
rule "Send dynamic Text to GT10D hourly"
|
||||
when
|
||||
Time cron "0 0 * * * ?"
|
||||
@@ -384,19 +384,19 @@ end
|
||||
|
||||
### Flicker Output
|
||||
|
||||
This *Action* realizes the LCN command "Output: Flicker" (German: "Ausgang: Flackern").
|
||||
This _Action_ realizes the LCN command "Output: Flicker" (German: "Ausgang: Flackern").
|
||||
The command let a dimmer output flash a given number of times. This feature can be used e.g. for alert signals or visual door bells.
|
||||
|
||||
When programming a "Flicker Output" *Action*, the following parameters need to be set:
|
||||
When programming a "Flicker Output" _Action_, the following parameters need to be set:
|
||||
|
||||
*output* - The dimmer output number: 1-4<br />
|
||||
*depth* - The depth of the flickering: 0-2 (0=25% 1=50% 2=100% Example: When the output is fully on (100%), and 0 is selected, flashes will dim from 100% to 75% and back)<br />
|
||||
*ramp* - The duration/ramp of one flash: 0-2 (0=2sec 1=1sec 2=0.5sec)<br />
|
||||
*count* - The number of flashes: 1-15
|
||||
_output_ - The dimmer output number: 1-4<br />
|
||||
_depth_ - The depth of the flickering: 0-2 (0=25% 1=50% 2=100% Example: When the output is fully on (100%), and 0 is selected, flashes will dim from 100% to 75% and back)<br />
|
||||
_ramp_ - The duration/ramp of one flash: 0-2 (0=2sec 1=1sec 2=0.5sec)<br />
|
||||
_count_ - The number of flashes: 1-15
|
||||
|
||||
This action has also effect, if the given output is off. The output will be dimmed from 0% to *depth* and back, then.
|
||||
This action has also effect, if the given output is off. The output will be dimmed from 0% to _depth_ and back, then.
|
||||
|
||||
```
|
||||
```java
|
||||
rule "Flicker output 1 when window opens"
|
||||
when
|
||||
Item M10_BinarySensor5 changed to OPEN
|
||||
@@ -409,15 +409,15 @@ end
|
||||
|
||||
### Relay Timer
|
||||
|
||||
This *Action* realizes the LCN commmand "Relay Timer" (German: "Relais-Timer").
|
||||
This _Action_ realizes the LCN commmand "Relay Timer" (German: "Relais-Timer").
|
||||
The command switches the given relay immediately to on and after a given time back to off.
|
||||
|
||||
When programming a "Relay Timer" *Action*, the following parameters need to be set:
|
||||
When programming a "Relay Timer" _Action_, the following parameters need to be set:
|
||||
|
||||
*relayNumber* - The relay number: 1-8<br />
|
||||
*duration* - Timer duration in milliseconds: 30-240.000 ms<br />
|
||||
_relayNumber_ - The relay number: 1-8<br />
|
||||
_duration_ - Timer duration in milliseconds: 30-240.000 ms<br />
|
||||
|
||||
```
|
||||
```java
|
||||
rule "Start relay timer for led driver when dummy switch changed"
|
||||
when
|
||||
Item Dummy_Switch changed
|
||||
@@ -430,14 +430,14 @@ end
|
||||
|
||||
### Beep
|
||||
|
||||
This *Action* realizes the LCN commmand "audio" (German: "Piepen").
|
||||
This _Action_ realizes the LCN commmand "audio" (German: "Piepen").
|
||||
It lets the beeper connected to the LCN module beep.
|
||||
|
||||
When programming an "audio" *Action*, the following parameters can be set:
|
||||
When programming an "audio" _Action_, the following parameters can be set:
|
||||
|
||||
*volume* - Sound volume in percent (if null, the previous volume will be used)<br />
|
||||
*tonality* - The tonality as a String. You need to use quotes. See below.<br />
|
||||
*count* - Number of beeps (max. 50)
|
||||
_volume_ - Sound volume in percent (if null, the previous volume will be used)<br />
|
||||
_tonality_ - The tonality as a String. You need to use quotes. See below.<br />
|
||||
_count_ - Number of beeps (max. 50)
|
||||
|
||||
Tonalities:
|
||||
|
||||
@@ -451,7 +451,7 @@ Tonalities:
|
||||
- "6"=error
|
||||
- "7"=long
|
||||
|
||||
```
|
||||
```java
|
||||
rule "Beep when dummy switch changed"
|
||||
when
|
||||
Item Dummy_Switch changed
|
||||
@@ -466,27 +466,27 @@ end
|
||||
|
||||
LCN segments are supported by this binding, but could not be tested, due to lack of hardware.
|
||||
|
||||
LEDs do not support the *OnOffCommand* and respectively the *Switch* Item type, because they have the additional states *BLINK* and *FLICKER*. They must be configured as *String* Item. When used in rules, the parameter must be of type string. Example: `M10_LED1.sendCommand("ON")`. Note the quotation marks.
|
||||
LEDs do not support the _OnOffCommand_ and respectively the _Switch_ Item type, because they have the additional states _BLINK_ and _FLICKER_. They must be configured as _String_ Item. When used in rules, the parameter must be of type string. Example: `M10_LED1.sendCommand("ON")`. Note the quotation marks.
|
||||
|
||||
## Full Example
|
||||
|
||||
Config `.things`
|
||||
|
||||
```
|
||||
```java
|
||||
Bridge lcn:pckGateway:myPCHK [ hostname="192.168.123.123", port=4114, username="myUser", password="myPassword", mode="native200" ] {
|
||||
Thing module M99 "M99 MyModule" [ moduleId=99, segmentId=0 ] {
|
||||
Channels:
|
||||
Thing module M99 "M99 MyModule" [ moduleId=99, segmentId=0 ] {
|
||||
Channels:
|
||||
Rollershutter : rollershutterrelay#1 "My twisted rollershutter relay" [ invertUpDown = true ]
|
||||
Contact : binarysensor#6 [ invertState=true ]
|
||||
Number : rvarsetpoint#1 [ unit="temperature" ]
|
||||
Number : variable#3 [ unit="temperature" ]
|
||||
}
|
||||
Contact : binarysensor#6 [ invertState=true ]
|
||||
Number : rvarsetpoint#1 [ unit="temperature" ]
|
||||
Number : variable#3 [ unit="temperature" ]
|
||||
}
|
||||
}
|
||||
```
|
||||
|
||||
Config `.items`
|
||||
|
||||
```
|
||||
```java
|
||||
// Dimmer Outputs
|
||||
Dimmer M10_Output1 {channel="lcn:module:b827ebfea4bb:S000M010:output#1"}
|
||||
Switch M10_Output2 {channel="lcn:module:b827ebfea4bb:S000M010:output#2"[profile="lcn:output", ramp=0.25]} // with ramp of 0.25s (smallest value)
|
||||