[Documentation] Markdown improvements f to m (#13866)
Signed-off-by: Jerome Luckenbach <github@luckenba.ch>
This commit is contained in:
committed by
GitHub
parent
3c236b3103
commit
0e68936663
@@ -18,7 +18,7 @@ Things in this extension will use the selected bridge to connect to the device.
|
||||
The configuration of a Helios Ventilation device via a `.things` file would look like the following code sample.
|
||||
It's required to provide the device's IP address, port and unit ID (port and unit ID cannot be changed and always have to be 502 and 180; in fact the values provided here are ignored by the binding and the fixed values 502 and 180 are used):
|
||||
|
||||
```
|
||||
```java
|
||||
Bridge modbus:tcp:modbus-gateway "Modbus TCP/IP Gateway" [ host="x.x.x.x", port=502, id=180, enableDiscovery=true ] {
|
||||
Thing helios-easycontrols kwl "KWL"
|
||||
}
|
||||
@@ -28,110 +28,109 @@ Bridge modbus:tcp:modbus-gateway "Modbus TCP/IP Gateway" [ host="x.x.x.x", port=
|
||||
|
||||
The following channels are supported:
|
||||
|
||||
| Channel | Channel Group | Description | Item Type | RW |
|
||||
| -------------------------------- | --------------- | -------------------------------------------------------------------------------------------------------------------------------- | ------------------------ | -- |
|
||||
| sysdate | general | The KWL's system date and time | DateTime | RW |
|
||||
| summerWinter | general | Indicates if summertime or wintertime is active (0 = wintertime, 1 = summertime) | Number | RW |
|
||||
| autoSwUpdate | general | Indicates if automatic software updates are enable | Switch | RW |
|
||||
| accessHeliosPortal | general | Indicates if access to Helios portal is enabled | Switch | RW |
|
||||
| minFanStage | unitConfig | Minimum fan stage (0 or 1) (0, 1) | Number | RW |
|
||||
| preHeaterStatus | general | Pre-Heater Status | Switch | RW |
|
||||
| humidityControlSetValue | humidityControl | Humidity control set value (in percent) (20 - 80 %) | Number:Dimensionless | RW |
|
||||
| humidityControlSteps | humidityControl | Humidity control steps (in percent) (5 - 20 %) | Number:Dimensionless | RW |
|
||||
| humidityStopTime | humidityControl | Humidity stop time in hours (0-24) (0 - 24 h) | Number:Time | RW |
|
||||
| co2ControlSetValue | co2Control | CO2 control set value (in ppm) (300 - 2000 ppm) | Number:Dimensionless | RW |
|
||||
| co2ControlSteps | co2Control | CO2 control steps (in ppm) (50 - 400 ppm) | Number:Dimensionless | RW |
|
||||
| vocControlSetValue | vocControl | VOC control set value (in ppm) (300 - 2000 ppm) | Number:Dimensionless | RW |
|
||||
| vocControlSteps | vocControl | VOC control steps (in ppm) (50 - 400 ppm) | Number:Dimensionless | RW |
|
||||
| comfortTemp | unitConfig | Comfort Temperature (10.0 - 25.0 °C) | Number:Temperature | RW |
|
||||
| partyModeDuration | operation | Party mode duration (in minutes) (5 - 180 min) | Number:Time | RW |
|
||||
| partyModeFanStage | operation | Party mode fan stage (0 - 4) | Number | RW |
|
||||
| partyModeRemainingTime | operation | Party mode remaining time (0 - 180 min) | Number:Time | R |
|
||||
| partyModeStatus | operation | Party mode status | Switch | RW |
|
||||
| standbyModeDuration | operation | Standby mode duration (in minutes) (5 - 180 min) | Number:Time | RW |
|
||||
| standbyModeFanStage | operation | Standby mode fan stage (0 - 4) | Number | RW |
|
||||
| standbyModeRemainingTime | operation | Standby mode remaining time (0 - 180 min) | Number:Time | R |
|
||||
| standbyModeStatus | operation | Standby mode status | Switch | RW |
|
||||
| operatingMode | operation | Operating mode (automatic/manual) (0 = automatic, 1 = manual) | Number | RW |
|
||||
| fanStage | operation | Fan stage (0 - 4) | Number | RW |
|
||||
| percentageFanStage | operation | Fan stage in percent (0 - 100 %) | Number:Dimensionless | R |
|
||||
| temperatureOutsideAir | general | Ouside air temperature in °C (-27.0 - 9998.9 °C) | Number:Temperature | R |
|
||||
| temperatureSupplyAir | general | Supply air temperature in °C (-27.0 - 9998.9 °C) | Number:Temperature | R |
|
||||
| temperatureOutgoingAir | general | Outgoing air temperature in °C (-27.0 - 9998.9 °C) | Number:Temperature | R |
|
||||
| temperatureExtractAir | general | Extract air temperature in °C (-27.0 - 9998.9 °C) | Number:Temperature | R |
|
||||
| vhzDuctSensor | general | Pre-heater intake temperature in °C (-27.0 - 9998.9 °C) | Number:Temperature | R |
|
||||
| nhzReturnSensor | general | After-heater return temperature in °C (-27.0 - 9998.9 °C) | Number:Temperature | R |
|
||||
| externalSensorKwlFtfHumidity1 | humidityControl | External humidity sensor 1 (-0.0 - 9998.9 %) | Number:Dimensionless | R |
|
||||
| externalSensorKwlFtfHumidity2 | humidityControl | External humidity sensor 2 (-0.0 - 9998.9 %) | Number:Dimensionless | R |
|
||||
| externalSensorKwlFtfHumidity3 | humidityControl | External humidity sensor 3 (-0.0 - 9998.9 %) | Number:Dimensionless | R |
|
||||
| externalSensorKwlFtfHumidity4 | humidityControl | External humidity sensor 4 (-0.0 - 9998.9 %) | Number:Dimensionless | R |
|
||||
| externalSensorKwlFtfHumidity5 | humidityControl | External humidity sensor 5 (-0.0 - 9998.9 %) | Number:Dimensionless | R |
|
||||
| externalSensorKwlFtfHumidity6 | humidityControl | External humidity sensor 6 (-0.0 - 9998.9 %) | Number:Dimensionless | R |
|
||||
| externalSensorKwlFtfHumidity7 | humidityControl | External humidity sensor 7 (-0.0 - 9998.9 %) | Number:Dimensionless | R |
|
||||
| externalSensorKwlFtfHumidity8 | humidityControl | External humidity sensor 8 (-0.0 - 9998.9 %) | Number:Dimensionless | R |
|
||||
| externalSensorKwlFtfTemperature1 | humidityControl | External temperature sensor 1 (-27.0 - 9998.9 °C) | Number:Temperature | R |
|
||||
| externalSensorKwlFtfTemperature2 | humidityControl | External temperature sensor 2 (-27.0 - 9998.9 °C) | Number:Temperature | R |
|
||||
| externalSensorKwlFtfTemperature3 | humidityControl | External temperature sensor 3 (-27.0 - 9998.9 °C) | Number:Temperature | R |
|
||||
| externalSensorKwlFtfTemperature4 | humidityControl | External temperature sensor 4 (-27.0 - 9998.9 °C) | Number:Temperature | R |
|
||||
| externalSensorKwlFtfTemperature5 | humidityControl | External temperature sensor 5 (-27.0 - 9998.9 °C) | Number:Temperature | R |
|
||||
| externalSensorKwlFtfTemperature6 | humidityControl | External temperature sensor 6 (-27.0 - 9998.9 °C) | Number:Temperature | R |
|
||||
| externalSensorKwlFtfTemperature7 | humidityControl | External temperature sensor 7 (-27.0 - 9998.9 °C) | Number:Temperature | R |
|
||||
| externalSensorKwlFtfTemperature8 | humidityControl | External temperature sensor 8 (-27.0 - 9998.9 °C) | Number:Temperature | R |
|
||||
| externalSensorKwlCo21 | co2Control | External CO2 sensor 1 (-0.0 - 9998.9 ppm) | Number:Dimensionless | R |
|
||||
| externalSensorKwlCo22 | co2Control | External CO2 sensor 2 (-0.0 - 9998.9 ppm) | Number:Dimensionless | R |
|
||||
| externalSensorKwlCo23 | co2Control | External CO2 sensor 3 (-0.0 - 9998.9 ppm) | Number:Dimensionless | R |
|
||||
| externalSensorKwlCo24 | co2Control | External CO2 sensor 4 (-0.0 - 9998.9 ppm) | Number:Dimensionless | R |
|
||||
| externalSensorKwlCo25 | co2Control | External CO2 sensor 5 (-0.0 - 9998.9 ppm) | Number:Dimensionless | R |
|
||||
| externalSensorKwlCo26 | co2Control | External CO2 sensor 6 (-0.0 - 9998.9 ppm) | Number:Dimensionless | R |
|
||||
| externalSensorKwlCo27 | co2Control | External CO2 sensor 7 (-0.0 - 9998.9 ppm) | Number:Dimensionless | R |
|
||||
| externalSensorKwlCo28 | co2Control | External CO2 sensor 8 (-0.0 - 9998.9 ppm) | Number:Dimensionless | R |
|
||||
| externalSensorKwlVoc1 | vocControl | External VOC sensor 1 (-0.0 - 9998.9 ppm) | Number:Dimensionless | R |
|
||||
| externalSensorKwlVoc2 | vocControl | External VOC sensor 2 (-0.0 - 9998.9 ppm) | Number:Dimensionless | R |
|
||||
| externalSensorKwlVoc3 | vocControl | External VOC sensor 3 (-0.0 - 9998.9 ppm) | Number:Dimensionless | R |
|
||||
| externalSensorKwlVoc4 | vocControl | External VOC sensor 4 (-0.0 - 9998.9 ppm) | Number:Dimensionless | R |
|
||||
| externalSensorKwlVoc5 | vocControl | External VOC sensor 5 (-0.0 - 9998.9 ppm) | Number:Dimensionless | R |
|
||||
| externalSensorKwlVoc6 | vocControl | External VOC sensor 6 (-0.0 - 9998.9 ppm) | Number:Dimensionless | R |
|
||||
| externalSensorKwlVoc7 | vocControl | External VOC sensor 7 (-0.0 - 9998.9 ppm) | Number:Dimensionless | R |
|
||||
| externalSensorKwlVoc8 | vocControl | External VOC sensor 8 (-0.0 - 9998.9 ppm) | Number:Dimensionless | R |
|
||||
| nhzDuctSensor | general | After-heater intake temperature in °C (-27.0 - 9998.9 °C) | Number:Temperature | R |
|
||||
| weekProfileNhz | profiles | Week profile after-heater (0 = standard 1, 1 = standard 2, 2 = fixed value, 3 = individual 1, 4 = individual 2, 5 = NA, 6 = off) | Number | RW |
|
||||
| supplyAirRpm | general | Supply air fan RPM (0 - 9999) | Number | R |
|
||||
| extractAirRpm | general | Extract air fan RPM (0 - 9999) | Number | R |
|
||||
| holidayProgramme | operation | Holiday programme (0 = off, 1 = interval, 2 = constant) | Number | RW |
|
||||
| holidayProgrammeFanStage | operation | Holiday programme fan stage (0 - 4) | Number | RW |
|
||||
| holidayProgrammeStart | operation | Holiday programme start | DateTime | RW |
|
||||
| holidayProgrammeEnd | operation | Holiday programme end | DateTime | RW |
|
||||
| holidayProgrammeInterval | operation | Holiday programme interval in hours (1 - 24 h) | Number:Time | RW |
|
||||
| holidayProgrammeActivationTime | operation | Holiday programme activation time in minutes (5 - 300 min) | Number:Time | RW |
|
||||
| runOnTimeVhzNhz | unitConfig | Stopping time preheater/afterheater in seconds (60 - 120 s) | Number:Time | RW |
|
||||
| errorOutputFunction | unitConfig | Error output function (collective error or just error) (1 = collective error, 2 = only error) | Number | RW |
|
||||
| filterChange | unitConfig | Filter change (0 = No, 1 = Yes) | Number | RW |
|
||||
| filterChangeInterval | unitConfig | Filter change interval in months (1 - 12) | Number | RW |
|
||||
| filterChangeRemainingTime | general | Filter change remaining time in minutes (1 - 55000 min) | Number:Time | R |
|
||||
| bypassRoomTemperature | unitConfig | Bypass room temperature in °C (10 - 40 °C) | Number:Temperature | RW |
|
||||
| bypassMinOutsideTemperature | unitConfig | Bypass outside temperature in °C (5 - 20 °C) | Number:Temperature | RW |
|
||||
| supplyAirFanStage | operation | Supply air fan stage (0 - 4) | Number | RW |
|
||||
| extractAirFanStage | operation | Extract air fan stage (0 - 4) | Number | RW |
|
||||
| operatingHoursSupplyAirVent | general | Operating hours supply air fan (in minutes) (0 - 2^32-1 min) | Number:Time | R |
|
||||
| operatingHoursExtractAirVent | general | Operating hours extract air fan (in minutes) (0 - 2^32-1 min) | Number:Time | R |
|
||||
| operatingHoursVhz | general | Operating hours preheater (in minutes) (0 - 2^32-1 min) | Number:Time | R |
|
||||
| operatingHoursNhz | general | Operating hours afterheater (in minutes) (0 - 2^32-1 min) | Number:Time | R |
|
||||
| outputPowerVhz | general | Output power of preheater (in percent) (0 - 2^32-1 %) | Number:Dimensionless | R |
|
||||
| outputPowerNhz | general | Output power of afterheater (in percent) (0 - 2^32-1 %) | Number:Dimensionless | R |
|
||||
| errors | general | Errors as integer value (see [Errors / Warnings / Infos](#errors-warnings-infos)) (0 - 2^32-1) | Number | R |
|
||||
| warnings | general | Warnings as integer value (see [Errors / Warnings / Infos](#errors-warnings-infos)) (0 - 2^32-1) | Number | R |
|
||||
| infos | general | Infos as integer value (see [Errors / Warnings / Infos](#errors-warnings-infos)) (0 - 2^32-1) | Number | R |
|
||||
| noOfErrors | general | Number of bit-coded errors (see [Errors / Warnings / Infos](#errors-warnings-infos)) (0 - 32) | Number | R |
|
||||
| noOfWarnings | general | Number of bit-coded warnings (see [Errors / Warnings / Infos](#errors-warnings-infos)) (0 - 8) | Number | R |
|
||||
| noOfInfos | general | Number of bit-coded infos (see [Errors / Warnings / Infos](#errors-warnings-infos)) (0 - 8) | Number | R |
|
||||
| errorsMsg | general | Errors as string (see [Errors / Warnings / Infos](#errors-warnings-infos)) | String | R |
|
||||
| warningsMsg | general | Warnings as string (see [Errors / Warnings / Infos](#errors-warnings-infos)) | String | R |
|
||||
| infosMsg | general | Infos as string (see [Errors / Warnings / Infos](#errors-warnings-infos)) | String | R |
|
||||
| statusFlags | general | Status flags (see [Errors / Warnings / Infos](#errors-warnings-infos)) | String | R |
|
||||
| bypassStatus | general | Status of the bypass (OFF = closed, ON = open) | Switch | R |
|
||||
| bypassFrom | unitConfig | Bypass active from | DateTime | RW |
|
||||
| bypassTo | unitConfig | Bypass active to | DateTime | RW |
|
||||
|
||||
| Channel | Channel Group | Description | Item Type | RW |
|
||||
| -------------------------------- | --------------- | -------------------------------------------------------------------------------------------------------------------------------- | ------------------------ | -- |
|
||||
| sysdate | general | The KWL's system date and time | DateTime | RW |
|
||||
| summerWinter | general | Indicates if summertime or wintertime is active (0 = wintertime, 1 = summertime) | Number | RW |
|
||||
| autoSwUpdate | general | Indicates if automatic software updates are enable | Switch | RW |
|
||||
| accessHeliosPortal | general | Indicates if access to Helios portal is enabled | Switch | RW |
|
||||
| minFanStage | unitConfig | Minimum fan stage (0 or 1) (0, 1) | Number | RW |
|
||||
| preHeaterStatus | general | Pre-Heater Status | Switch | RW |
|
||||
| humidityControlSetValue | humidityControl | Humidity control set value (in percent) (20 - 80 %) | Number:Dimensionless | RW |
|
||||
| humidityControlSteps | humidityControl | Humidity control steps (in percent) (5 - 20 %) | Number:Dimensionless | RW |
|
||||
| humidityStopTime | humidityControl | Humidity stop time in hours (0-24) (0 - 24 h) | Number:Time | RW |
|
||||
| co2ControlSetValue | co2Control | CO2 control set value (in ppm) (300 - 2000 ppm) | Number:Dimensionless | RW |
|
||||
| co2ControlSteps | co2Control | CO2 control steps (in ppm) (50 - 400 ppm) | Number:Dimensionless | RW |
|
||||
| vocControlSetValue | vocControl | VOC control set value (in ppm) (300 - 2000 ppm) | Number:Dimensionless | RW |
|
||||
| vocControlSteps | vocControl | VOC control steps (in ppm) (50 - 400 ppm) | Number:Dimensionless | RW |
|
||||
| comfortTemp | unitConfig | Comfort Temperature (10.0 - 25.0 °C) | Number:Temperature | RW |
|
||||
| partyModeDuration | operation | Party mode duration (in minutes) (5 - 180 min) | Number:Time | RW |
|
||||
| partyModeFanStage | operation | Party mode fan stage (0 - 4) | Number | RW |
|
||||
| partyModeRemainingTime | operation | Party mode remaining time (0 - 180 min) | Number:Time | R |
|
||||
| partyModeStatus | operation | Party mode status | Switch | RW |
|
||||
| standbyModeDuration | operation | Standby mode duration (in minutes) (5 - 180 min) | Number:Time | RW |
|
||||
| standbyModeFanStage | operation | Standby mode fan stage (0 - 4) | Number | RW |
|
||||
| standbyModeRemainingTime | operation | Standby mode remaining time (0 - 180 min) | Number:Time | R |
|
||||
| standbyModeStatus | operation | Standby mode status | Switch | RW |
|
||||
| operatingMode | operation | Operating mode (automatic/manual) (0 = automatic, 1 = manual) | Number | RW |
|
||||
| fanStage | operation | Fan stage (0 - 4) | Number | RW |
|
||||
| percentageFanStage | operation | Fan stage in percent (0 - 100 %) | Number:Dimensionless | R |
|
||||
| temperatureOutsideAir | general | Ouside air temperature in °C (-27.0 - 9998.9 °C) | Number:Temperature | R |
|
||||
| temperatureSupplyAir | general | Supply air temperature in °C (-27.0 - 9998.9 °C) | Number:Temperature | R |
|
||||
| temperatureOutgoingAir | general | Outgoing air temperature in °C (-27.0 - 9998.9 °C) | Number:Temperature | R |
|
||||
| temperatureExtractAir | general | Extract air temperature in °C (-27.0 - 9998.9 °C) | Number:Temperature | R |
|
||||
| vhzDuctSensor | general | Pre-heater intake temperature in °C (-27.0 - 9998.9 °C) | Number:Temperature | R |
|
||||
| nhzReturnSensor | general | After-heater return temperature in °C (-27.0 - 9998.9 °C) | Number:Temperature | R |
|
||||
| externalSensorKwlFtfHumidity1 | humidityControl | External humidity sensor 1 (-0.0 - 9998.9 %) | Number:Dimensionless | R |
|
||||
| externalSensorKwlFtfHumidity2 | humidityControl | External humidity sensor 2 (-0.0 - 9998.9 %) | Number:Dimensionless | R |
|
||||
| externalSensorKwlFtfHumidity3 | humidityControl | External humidity sensor 3 (-0.0 - 9998.9 %) | Number:Dimensionless | R |
|
||||
| externalSensorKwlFtfHumidity4 | humidityControl | External humidity sensor 4 (-0.0 - 9998.9 %) | Number:Dimensionless | R |
|
||||
| externalSensorKwlFtfHumidity5 | humidityControl | External humidity sensor 5 (-0.0 - 9998.9 %) | Number:Dimensionless | R |
|
||||
| externalSensorKwlFtfHumidity6 | humidityControl | External humidity sensor 6 (-0.0 - 9998.9 %) | Number:Dimensionless | R |
|
||||
| externalSensorKwlFtfHumidity7 | humidityControl | External humidity sensor 7 (-0.0 - 9998.9 %) | Number:Dimensionless | R |
|
||||
| externalSensorKwlFtfHumidity8 | humidityControl | External humidity sensor 8 (-0.0 - 9998.9 %) | Number:Dimensionless | R |
|
||||
| externalSensorKwlFtfTemperature1 | humidityControl | External temperature sensor 1 (-27.0 - 9998.9 °C) | Number:Temperature | R |
|
||||
| externalSensorKwlFtfTemperature2 | humidityControl | External temperature sensor 2 (-27.0 - 9998.9 °C) | Number:Temperature | R |
|
||||
| externalSensorKwlFtfTemperature3 | humidityControl | External temperature sensor 3 (-27.0 - 9998.9 °C) | Number:Temperature | R |
|
||||
| externalSensorKwlFtfTemperature4 | humidityControl | External temperature sensor 4 (-27.0 - 9998.9 °C) | Number:Temperature | R |
|
||||
| externalSensorKwlFtfTemperature5 | humidityControl | External temperature sensor 5 (-27.0 - 9998.9 °C) | Number:Temperature | R |
|
||||
| externalSensorKwlFtfTemperature6 | humidityControl | External temperature sensor 6 (-27.0 - 9998.9 °C) | Number:Temperature | R |
|
||||
| externalSensorKwlFtfTemperature7 | humidityControl | External temperature sensor 7 (-27.0 - 9998.9 °C) | Number:Temperature | R |
|
||||
| externalSensorKwlFtfTemperature8 | humidityControl | External temperature sensor 8 (-27.0 - 9998.9 °C) | Number:Temperature | R |
|
||||
| externalSensorKwlCo21 | co2Control | External CO2 sensor 1 (-0.0 - 9998.9 ppm) | Number:Dimensionless | R |
|
||||
| externalSensorKwlCo22 | co2Control | External CO2 sensor 2 (-0.0 - 9998.9 ppm) | Number:Dimensionless | R |
|
||||
| externalSensorKwlCo23 | co2Control | External CO2 sensor 3 (-0.0 - 9998.9 ppm) | Number:Dimensionless | R |
|
||||
| externalSensorKwlCo24 | co2Control | External CO2 sensor 4 (-0.0 - 9998.9 ppm) | Number:Dimensionless | R |
|
||||
| externalSensorKwlCo25 | co2Control | External CO2 sensor 5 (-0.0 - 9998.9 ppm) | Number:Dimensionless | R |
|
||||
| externalSensorKwlCo26 | co2Control | External CO2 sensor 6 (-0.0 - 9998.9 ppm) | Number:Dimensionless | R |
|
||||
| externalSensorKwlCo27 | co2Control | External CO2 sensor 7 (-0.0 - 9998.9 ppm) | Number:Dimensionless | R |
|
||||
| externalSensorKwlCo28 | co2Control | External CO2 sensor 8 (-0.0 - 9998.9 ppm) | Number:Dimensionless | R |
|
||||
| externalSensorKwlVoc1 | vocControl | External VOC sensor 1 (-0.0 - 9998.9 ppm) | Number:Dimensionless | R |
|
||||
| externalSensorKwlVoc2 | vocControl | External VOC sensor 2 (-0.0 - 9998.9 ppm) | Number:Dimensionless | R |
|
||||
| externalSensorKwlVoc3 | vocControl | External VOC sensor 3 (-0.0 - 9998.9 ppm) | Number:Dimensionless | R |
|
||||
| externalSensorKwlVoc4 | vocControl | External VOC sensor 4 (-0.0 - 9998.9 ppm) | Number:Dimensionless | R |
|
||||
| externalSensorKwlVoc5 | vocControl | External VOC sensor 5 (-0.0 - 9998.9 ppm) | Number:Dimensionless | R |
|
||||
| externalSensorKwlVoc6 | vocControl | External VOC sensor 6 (-0.0 - 9998.9 ppm) | Number:Dimensionless | R |
|
||||
| externalSensorKwlVoc7 | vocControl | External VOC sensor 7 (-0.0 - 9998.9 ppm) | Number:Dimensionless | R |
|
||||
| externalSensorKwlVoc8 | vocControl | External VOC sensor 8 (-0.0 - 9998.9 ppm) | Number:Dimensionless | R |
|
||||
| nhzDuctSensor | general | After-heater intake temperature in °C (-27.0 - 9998.9 °C) | Number:Temperature | R |
|
||||
| weekProfileNhz | profiles | Week profile after-heater (0 = standard 1, 1 = standard 2, 2 = fixed value, 3 = individual 1, 4 = individual 2, 5 = NA, 6 = off) | Number | RW |
|
||||
| supplyAirRpm | general | Supply air fan RPM (0 - 9999) | Number | R |
|
||||
| extractAirRpm | general | Extract air fan RPM (0 - 9999) | Number | R |
|
||||
| holidayProgramme | operation | Holiday programme (0 = off, 1 = interval, 2 = constant) | Number | RW |
|
||||
| holidayProgrammeFanStage | operation | Holiday programme fan stage (0 - 4) | Number | RW |
|
||||
| holidayProgrammeStart | operation | Holiday programme start | DateTime | RW |
|
||||
| holidayProgrammeEnd | operation | Holiday programme end | DateTime | RW |
|
||||
| holidayProgrammeInterval | operation | Holiday programme interval in hours (1 - 24 h) | Number:Time | RW |
|
||||
| holidayProgrammeActivationTime | operation | Holiday programme activation time in minutes (5 - 300 min) | Number:Time | RW |
|
||||
| runOnTimeVhzNhz | unitConfig | Stopping time preheater/afterheater in seconds (60 - 120 s) | Number:Time | RW |
|
||||
| errorOutputFunction | unitConfig | Error output function (collective error or just error) (1 = collective error, 2 = only error) | Number | RW |
|
||||
| filterChange | unitConfig | Filter change (0 = No, 1 = Yes) | Number | RW |
|
||||
| filterChangeInterval | unitConfig | Filter change interval in months (1 - 12) | Number | RW |
|
||||
| filterChangeRemainingTime | general | Filter change remaining time in minutes (1 - 55000 min) | Number:Time | R |
|
||||
| bypassRoomTemperature | unitConfig | Bypass room temperature in °C (10 - 40 °C) | Number:Temperature | RW |
|
||||
| bypassMinOutsideTemperature | unitConfig | Bypass outside temperature in °C (5 - 20 °C) | Number:Temperature | RW |
|
||||
| supplyAirFanStage | operation | Supply air fan stage (0 - 4) | Number | RW |
|
||||
| extractAirFanStage | operation | Extract air fan stage (0 - 4) | Number | RW |
|
||||
| operatingHoursSupplyAirVent | general | Operating hours supply air fan (in minutes) (0 - 2^32-1 min) | Number:Time | R |
|
||||
| operatingHoursExtractAirVent | general | Operating hours extract air fan (in minutes) (0 - 2^32-1 min) | Number:Time | R |
|
||||
| operatingHoursVhz | general | Operating hours preheater (in minutes) (0 - 2^32-1 min) | Number:Time | R |
|
||||
| operatingHoursNhz | general | Operating hours afterheater (in minutes) (0 - 2^32-1 min) | Number:Time | R |
|
||||
| outputPowerVhz | general | Output power of preheater (in percent) (0 - 2^32-1 %) | Number:Dimensionless | R |
|
||||
| outputPowerNhz | general | Output power of afterheater (in percent) (0 - 2^32-1 %) | Number:Dimensionless | R |
|
||||
| errors | general | Errors as integer value (see [Errors / Warnings / Infos](#errors--warnings--infos)) (0 - 2^32-1) | Number | R |
|
||||
| warnings | general | Warnings as integer value (see [Errors / Warnings / Infos](#errors--warnings--infos)) (0 - 2^32-1) | Number | R |
|
||||
| infos | general | Infos as integer value (see [Errors / Warnings / Infos](#errors--warnings--infos)) (0 - 2^32-1) | Number | R |
|
||||
| noOfErrors | general | Number of bit-coded errors (see [Errors / Warnings / Infos](#errors--warnings--infos)) (0 - 32) | Number | R |
|
||||
| noOfWarnings | general | Number of bit-coded warnings (see [Errors / Warnings / Infos](#errors--warnings--infos)) (0 - 8) | Number | R |
|
||||
| noOfInfos | general | Number of bit-coded infos (see [Errors / Warnings / Infos](#errors--warnings--infos)) (0 - 8) | Number | R |
|
||||
| errorsMsg | general | Errors as string (see [Errors / Warnings / Infos](#errors--warnings--infos)) | String | R |
|
||||
| warningsMsg | general | Warnings as string (see [Errors / Warnings / Infos](#errors--warnings--infos)) | String | R |
|
||||
| infosMsg | general | Infos as string (see [Errors / Warnings / Infos](#errors--warnings--infos)) | String | R |
|
||||
| statusFlags | general | Status flags (see [Errors / Warnings / Infos](#errors--warnings--infos)) | String | R |
|
||||
| bypassStatus | general | Status of the bypass (OFF = closed, ON = open) | Switch | R |
|
||||
| bypassFrom | unitConfig | Bypass active from | DateTime | RW |
|
||||
| bypassTo | unitConfig | Bypass active to | DateTime | RW |
|
||||
|
||||
## Thing Actions
|
||||
|
||||
@@ -139,7 +138,7 @@ The following channels are supported:
|
||||
|
||||
Resets the timer for the next filter change back to 0.
|
||||
|
||||
```
|
||||
```java
|
||||
public void resetFilterChangeTimer()
|
||||
```
|
||||
|
||||
@@ -147,7 +146,7 @@ public void resetFilterChangeTimer()
|
||||
|
||||
Resets the error messages.
|
||||
|
||||
```
|
||||
```java
|
||||
public void resetErrors()
|
||||
```
|
||||
|
||||
@@ -155,7 +154,7 @@ public void resetErrors()
|
||||
|
||||
Resets the device to its factory defaults.
|
||||
|
||||
```
|
||||
```java
|
||||
public void presetToFactoryDefaults()
|
||||
```
|
||||
|
||||
@@ -163,16 +162,15 @@ public void presetToFactoryDefaults()
|
||||
|
||||
Resets the device's individual switching times back to the default values.
|
||||
|
||||
```
|
||||
```java
|
||||
public void resetSwitchingTimes()
|
||||
```
|
||||
|
||||
|
||||
### Set System Date and Time
|
||||
|
||||
Sets the device's system date and time to the openHAB server's system date and time.
|
||||
|
||||
```
|
||||
```java
|
||||
public void setSysDateTime()
|
||||
```
|
||||
|
||||
@@ -180,154 +178,146 @@ public void setSysDateTime()
|
||||
|
||||
Sets the devices start and end date for the active bypass functionality.
|
||||
|
||||
```
|
||||
```java
|
||||
public void setBypassFrom(int day, int month)
|
||||
```
|
||||
|
||||
*Parameters:*
|
||||
_Parameters:_
|
||||
|
||||
* *day:* The day from when the bypass should be active
|
||||
* *month:* The month from when the bypass should be active
|
||||
- _day:_ The day from when the bypass should be active
|
||||
- _month:_ The month from when the bypass should be active
|
||||
|
||||
|
||||
```
|
||||
```java
|
||||
public void setBypassTo(int day, int month)
|
||||
```
|
||||
|
||||
*Parameters:*
|
||||
_Parameters:_
|
||||
|
||||
* *day:* The day until when the bypass should be active
|
||||
* *month:* The month until when the bypass should be active
|
||||
- _day:_ The day until when the bypass should be active
|
||||
- _month:_ The month until when the bypass should be active
|
||||
|
||||
|
||||
```
|
||||
```java
|
||||
public Map<String, Object> getErrorMessages()
|
||||
```
|
||||
|
||||
*Return values:*
|
||||
_Return values:_
|
||||
|
||||
* *errorMessages:* A `List<String>` object containing all error messages
|
||||
- _errorMessages:_ A `List<String>` object containing all error messages
|
||||
|
||||
|
||||
```
|
||||
```java
|
||||
public Map<String, Object> getWarningMessages()
|
||||
```
|
||||
|
||||
*Return values:*
|
||||
_Return values:_
|
||||
|
||||
* *warningMessages:* A `List<String>` object containing all warning messages
|
||||
- _warningMessages:_ A `List<String>` object containing all warning messages
|
||||
|
||||
|
||||
```
|
||||
```java
|
||||
public Map<String, Object> getInfoMessages()
|
||||
```
|
||||
|
||||
*Return values:*
|
||||
_Return values:_
|
||||
|
||||
* *infoMessages:* A `List<String>` object containing all info messages
|
||||
- _infoMessages:_ A `List<String>` object containing all info messages
|
||||
|
||||
|
||||
```
|
||||
```java
|
||||
public Map<String, Object> getStatusMessages()
|
||||
```
|
||||
|
||||
*Return values:*
|
||||
_Return values:_
|
||||
|
||||
* *statusMessages:* A `List<String>` object containing all status messages
|
||||
- _statusMessages:_ A `List<String>` object containing all status messages
|
||||
|
||||
|
||||
```
|
||||
```java
|
||||
public Map<String, Object> getMessages()
|
||||
```
|
||||
|
||||
*Return values:*
|
||||
|
||||
* *errorMessages:* A `List<String>` object containing all error messages
|
||||
* *warningMessages:* A `List<String>` object containing all warning messages
|
||||
* *infoMessages:* A `List<String>` object containing all info messages
|
||||
* *statusMessages:* A `List<String>` object containing all status messages
|
||||
_Return values:_
|
||||
|
||||
- _errorMessages:_ A `List<String>` object containing all error messages
|
||||
- _warningMessages:_ A `List<String>` object containing all warning messages
|
||||
- _infoMessages:_ A `List<String>` object containing all info messages
|
||||
- _statusMessages:_ A `List<String>` object containing all status messages
|
||||
|
||||
## Properties
|
||||
|
||||
The binding provides the following properties:
|
||||
|
||||
| Property | Description |
|
||||
| -------------------------------- | -------------------------------------------------------------------------------------------------------------------------------- |
|
||||
| articleDescription | The KWL's article description |
|
||||
| refNo | The KWL's reference number |
|
||||
| macAddress | The KWL's MAC Address |
|
||||
| language | The KWL user interface's language (de, en, fr, hr, hu, it, pl, sk, sl) |
|
||||
| voltageFanStage1ExtractAir | Voltage of extract air fan mapped to fan stage 1 (1.6 - 10 V) |
|
||||
| voltageFanStage2ExtractAir | Voltage of extract air fan mapped to fan stage 2 (1.6 - 10 V) |
|
||||
| voltageFanStage3ExtractAir | Voltage of extract air fan mapped to fan stage 3 (1.6 - 10 V) |
|
||||
| voltageFanStage4ExtractAir | Voltage of extract air fan mapped to fan stage 4 (1.6 - 10 V) |
|
||||
| voltageFanStage1SupplyAir | Voltage of supply air fan mapped to fan stage 1 (1.6 - 10 V) |
|
||||
| voltageFanStage2SupplyAir | Voltage of supply air fan mapped to fan stage 2 (1.6 - 10 V) |
|
||||
| voltageFanStage3SupplyAir | Voltage of supply air fan mapped to fan stage 3 (1.6 - 10 V) |
|
||||
| voltageFanStage4SupplyAir | Voltage of supply air fan mapped to fan stage 4 (1.6 - 10 V) |
|
||||
| kwlBe | Slide switch controller KWL-BE activated |
|
||||
| kwlBec | Comfort controller KWL-BEC activated |
|
||||
| unitConfig | Ventilation unit configuration (type of house) (1 = DiBt, 2 = passive-house) |
|
||||
| kwlFtfConfig0 | Humidity/temperature sensor configuration 0 (1 = only humidity, 2 = only temperature, 3 = combined) |
|
||||
| kwlFtfConfig1 | Humidity/temperature sensor configuration 1 (1 = only humidity, 2 = only temperature, 3 = combined) |
|
||||
| kwlFtfConfig2 | Humidity/temperature sensor configuration 2 (1 = only humidity, 2 = only temperature, 3 = combined) |
|
||||
| kwlFtfConfig3 | Humidity/temperature sensor configuration 3 (1 = only humidity, 2 = only temperature, 3 = combined) |
|
||||
| kwlFtfConfig4 | Humidity/temperature sensor configuration 4 (1 = only humidity, 2 = only temperature, 3 = combined) |
|
||||
| kwlFtfConfig5 | Humidity/temperature sensor configuration 5 (1 = only humidity, 2 = only temperature, 3 = combined) |
|
||||
| kwlFtfConfig6 | Humidity/temperature sensor configuration 6 (1 = only humidity, 2 = only temperature, 3 = combined) |
|
||||
| kwlFtfConfig7 | Humidity/temperature sensor configuration 7 (1 = only humidity, 2 = only temperature, 3 = combined) |
|
||||
| humidityControlStatus | Humidity control status (0 = off, 1 = stepped, 2 = stepless) |
|
||||
| co2ControlStatus | CO2 control status (0 = off, 1 = stepped, 2 = stepless) |
|
||||
| vocControlStatus | VOC control status (0 = off, 1 = stepped, 2 = stepless) |
|
||||
| dateFormat | Date format (0 = dd.mm.yyyy, 1 = mm.dd.yyyy, 2 = yyyy.mm.dd) |
|
||||
| heatExchangerType | Heat exchanger type (1 = plastic, 2 = aluminium, 3 = enthalpy) |
|
||||
| serNo | Serial number |
|
||||
| prodCode | Production Code |
|
||||
| vhzType | Pre-heater type (1 = EH-Basis, 2 EH-ERW, 3 = SEWT, 4 = LEWT) |
|
||||
| functionTypeKwlEm | Function KWL-EM (1 = function 1, 2 = function 2) |
|
||||
| externalContact | External contact (1 -6 (function 1-6)) |
|
||||
| fanStageStepped0to2v | Fan stage for stepped mode - range 0-2V (0 - 2) |
|
||||
| fanStageStepped2to4v | Fan stage for stepped mode - range 2-4V (0 - 4) |
|
||||
| fanStageStepped4to6v | Fan stage for stepped mode - range 4-6V (0 - 4) |
|
||||
| fanStageStepped6to8v | Fan stage for stepped mode - range 6-8V (0 - 4) |
|
||||
| fanStageStepped8to10v | Fan stage for stepped mode - range 8-10V (0 - 4) |
|
||||
| offsetExtractAir | Offset extract air (float) |
|
||||
| assignmentFanStages | Assignment fan stages - stepped or 0-10V (OFF = 0-10V, ON = stepped) |
|
||||
| sensorNameHumidityAndTemp1 | Sensor name - humidity and temperature 1 |
|
||||
| sensorNameHumidityAndTemp2 | Sensor name - humidity and temperature 2 |
|
||||
| sensorNameHumidityAndTemp3 | Sensor name - humidity and temperature 3 |
|
||||
| sensorNameHumidityAndTemp4 | Sensor name - humidity and temperature 4 |
|
||||
| sensorNameHumidityAndTemp5 | Sensor name - humidity and temperature 5 |
|
||||
| sensorNameHumidityAndTemp6 | Sensor name - humidity and temperature 6 |
|
||||
| sensorNameHumidityAndTemp7 | Sensor name - humidity and temperature 7 |
|
||||
| sensorNameHumidityAndTemp8 | Sensor name - humidity and temperature 8 |
|
||||
| sensorNameCo21 | Sensor name - CO2 1 |
|
||||
| sensorNameCo22 | Sensor name - CO2 2 |
|
||||
| sensorNameCo23 | Sensor name - CO2 3 |
|
||||
| sensorNameCo24 | Sensor name - CO2 4 |
|
||||
| sensorNameCo25 | Sensor name - CO2 5 |
|
||||
| sensorNameCo26 | Sensor name - CO2 6 |
|
||||
| sensorNameCo27 | Sensor name - CO2 7 |
|
||||
| sensorNameCo28 | Sensor name - CO2 8 |
|
||||
| sensorNameVoc1 | Sensor name - VOC 1 |
|
||||
| sensorNameVoc2 | Sensor name - VOC 2 |
|
||||
| sensorNameVoc3 | Sensor name - VOC 3 |
|
||||
| sensorNameVoc4 | Sensor name - VOC 4 |
|
||||
| sensorNameVoc5 | Sensor name - VOC 5 |
|
||||
| sensorNameVoc6 | Sensor name - VOC 6 |
|
||||
| sensorNameVoc7 | Sensor name - VOC 7 |
|
||||
| sensorNameVoc8 | Sensor name - VOC 8 |
|
||||
| softwareVersionBasis | Software version basis (format xx.xx) |
|
||||
| sensorConfigKwlFtf1 | Sensor configuration (installed or not) KWL-FTF 1 (OFF = no sensor, ON = sensor installed) |
|
||||
| sensorConfigKwlFtf2 | Sensor configuration (installed or not) KWL-FTF 2 (OFF = no sensor, ON = sensor installed) |
|
||||
| sensorConfigKwlFtf3 | Sensor configuration (installed or not) KWL-FTF 3 (OFF = no sensor, ON = sensor installed) |
|
||||
| sensorConfigKwlFtf4 | Sensor configuration (installed or not) KWL-FTF 4 (OFF = no sensor, ON = sensor installed) |
|
||||
| sensorConfigKwlFtf5 | Sensor configuration (installed or not) KWL-FTF 5 (OFF = no sensor, ON = sensor installed) |
|
||||
| sensorConfigKwlFtf6 | Sensor configuration (installed or not) KWL-FTF 6 (OFF = no sensor, ON = sensor installed) |
|
||||
| sensorConfigKwlFtf7 | Sensor configuration (installed or not) KWL-FTF 7 (OFF = no sensor, ON = sensor installed) |
|
||||
| sensorConfigKwlFtf8 | Sensor configuration (installed or not) KWL-FTF 8 (OFF = no sensor, ON = sensor installed) |
|
||||
|
||||
| Property | Description |
|
||||
| -------------------------------- | -------------------------------------------------------------------------------------------------------------------------------- |
|
||||
| articleDescription | The KWL's article description |
|
||||
| refNo | The KWL's reference number |
|
||||
| macAddress | The KWL's MAC Address |
|
||||
| language | The KWL user interface's language (de, en, fr, hr, hu, it, pl, sk, sl) |
|
||||
| voltageFanStage1ExtractAir | Voltage of extract air fan mapped to fan stage 1 (1.6 - 10 V) |
|
||||
| voltageFanStage2ExtractAir | Voltage of extract air fan mapped to fan stage 2 (1.6 - 10 V) |
|
||||
| voltageFanStage3ExtractAir | Voltage of extract air fan mapped to fan stage 3 (1.6 - 10 V) |
|
||||
| voltageFanStage4ExtractAir | Voltage of extract air fan mapped to fan stage 4 (1.6 - 10 V) |
|
||||
| voltageFanStage1SupplyAir | Voltage of supply air fan mapped to fan stage 1 (1.6 - 10 V) |
|
||||
| voltageFanStage2SupplyAir | Voltage of supply air fan mapped to fan stage 2 (1.6 - 10 V) |
|
||||
| voltageFanStage3SupplyAir | Voltage of supply air fan mapped to fan stage 3 (1.6 - 10 V) |
|
||||
| voltageFanStage4SupplyAir | Voltage of supply air fan mapped to fan stage 4 (1.6 - 10 V) |
|
||||
| kwlBe | Slide switch controller KWL-BE activated |
|
||||
| kwlBec | Comfort controller KWL-BEC activated |
|
||||
| unitConfig | Ventilation unit configuration (type of house) (1 = DiBt, 2 = passive-house) |
|
||||
| kwlFtfConfig0 | Humidity/temperature sensor configuration 0 (1 = only humidity, 2 = only temperature, 3 = combined) |
|
||||
| kwlFtfConfig1 | Humidity/temperature sensor configuration 1 (1 = only humidity, 2 = only temperature, 3 = combined) |
|
||||
| kwlFtfConfig2 | Humidity/temperature sensor configuration 2 (1 = only humidity, 2 = only temperature, 3 = combined) |
|
||||
| kwlFtfConfig3 | Humidity/temperature sensor configuration 3 (1 = only humidity, 2 = only temperature, 3 = combined) |
|
||||
| kwlFtfConfig4 | Humidity/temperature sensor configuration 4 (1 = only humidity, 2 = only temperature, 3 = combined) |
|
||||
| kwlFtfConfig5 | Humidity/temperature sensor configuration 5 (1 = only humidity, 2 = only temperature, 3 = combined) |
|
||||
| kwlFtfConfig6 | Humidity/temperature sensor configuration 6 (1 = only humidity, 2 = only temperature, 3 = combined) |
|
||||
| kwlFtfConfig7 | Humidity/temperature sensor configuration 7 (1 = only humidity, 2 = only temperature, 3 = combined) |
|
||||
| humidityControlStatus | Humidity control status (0 = off, 1 = stepped, 2 = stepless) |
|
||||
| co2ControlStatus | CO2 control status (0 = off, 1 = stepped, 2 = stepless) |
|
||||
| vocControlStatus | VOC control status (0 = off, 1 = stepped, 2 = stepless) |
|
||||
| dateFormat | Date format (0 = dd.mm.yyyy, 1 = mm.dd.yyyy, 2 = yyyy.mm.dd) |
|
||||
| heatExchangerType | Heat exchanger type (1 = plastic, 2 = aluminium, 3 = enthalpy) |
|
||||
| serNo | Serial number |
|
||||
| prodCode | Production Code |
|
||||
| vhzType | Pre-heater type (1 = EH-Basis, 2 EH-ERW, 3 = SEWT, 4 = LEWT) |
|
||||
| functionTypeKwlEm | Function KWL-EM (1 = function 1, 2 = function 2) |
|
||||
| externalContact | External contact (1 -6 (function 1-6)) |
|
||||
| fanStageStepped0to2v | Fan stage for stepped mode - range 0-2V (0 - 2) |
|
||||
| fanStageStepped2to4v | Fan stage for stepped mode - range 2-4V (0 - 4) |
|
||||
| fanStageStepped4to6v | Fan stage for stepped mode - range 4-6V (0 - 4) |
|
||||
| fanStageStepped6to8v | Fan stage for stepped mode - range 6-8V (0 - 4) |
|
||||
| fanStageStepped8to10v | Fan stage for stepped mode - range 8-10V (0 - 4) |
|
||||
| offsetExtractAir | Offset extract air (float) |
|
||||
| assignmentFanStages | Assignment fan stages - stepped or 0-10V (OFF = 0-10V, ON = stepped) |
|
||||
| sensorNameHumidityAndTemp1 | Sensor name - humidity and temperature 1 |
|
||||
| sensorNameHumidityAndTemp2 | Sensor name - humidity and temperature 2 |
|
||||
| sensorNameHumidityAndTemp3 | Sensor name - humidity and temperature 3 |
|
||||
| sensorNameHumidityAndTemp4 | Sensor name - humidity and temperature 4 |
|
||||
| sensorNameHumidityAndTemp5 | Sensor name - humidity and temperature 5 |
|
||||
| sensorNameHumidityAndTemp6 | Sensor name - humidity and temperature 6 |
|
||||
| sensorNameHumidityAndTemp7 | Sensor name - humidity and temperature 7 |
|
||||
| sensorNameHumidityAndTemp8 | Sensor name - humidity and temperature 8 |
|
||||
| sensorNameCo21 | Sensor name - CO2 1 |
|
||||
| sensorNameCo22 | Sensor name - CO2 2 |
|
||||
| sensorNameCo23 | Sensor name - CO2 3 |
|
||||
| sensorNameCo24 | Sensor name - CO2 4 |
|
||||
| sensorNameCo25 | Sensor name - CO2 5 |
|
||||
| sensorNameCo26 | Sensor name - CO2 6 |
|
||||
| sensorNameCo27 | Sensor name - CO2 7 |
|
||||
| sensorNameCo28 | Sensor name - CO2 8 |
|
||||
| sensorNameVoc1 | Sensor name - VOC 1 |
|
||||
| sensorNameVoc2 | Sensor name - VOC 2 |
|
||||
| sensorNameVoc3 | Sensor name - VOC 3 |
|
||||
| sensorNameVoc4 | Sensor name - VOC 4 |
|
||||
| sensorNameVoc5 | Sensor name - VOC 5 |
|
||||
| sensorNameVoc6 | Sensor name - VOC 6 |
|
||||
| sensorNameVoc7 | Sensor name - VOC 7 |
|
||||
| sensorNameVoc8 | Sensor name - VOC 8 |
|
||||
| softwareVersionBasis | Software version basis (format xx.xx) |
|
||||
| sensorConfigKwlFtf1 | Sensor configuration (installed or not) KWL-FTF 1 (OFF = no sensor, ON = sensor installed) |
|
||||
| sensorConfigKwlFtf2 | Sensor configuration (installed or not) KWL-FTF 2 (OFF = no sensor, ON = sensor installed) |
|
||||
| sensorConfigKwlFtf3 | Sensor configuration (installed or not) KWL-FTF 3 (OFF = no sensor, ON = sensor installed) |
|
||||
| sensorConfigKwlFtf4 | Sensor configuration (installed or not) KWL-FTF 4 (OFF = no sensor, ON = sensor installed) |
|
||||
| sensorConfigKwlFtf5 | Sensor configuration (installed or not) KWL-FTF 5 (OFF = no sensor, ON = sensor installed) |
|
||||
| sensorConfigKwlFtf6 | Sensor configuration (installed or not) KWL-FTF 6 (OFF = no sensor, ON = sensor installed) |
|
||||
| sensorConfigKwlFtf7 | Sensor configuration (installed or not) KWL-FTF 7 (OFF = no sensor, ON = sensor installed) |
|
||||
| sensorConfigKwlFtf8 | Sensor configuration (installed or not) KWL-FTF 8 (OFF = no sensor, ON = sensor installed) |
|
||||
|
||||
## Errors / Warnings / Infos
|
||||
|
||||
@@ -336,19 +326,18 @@ Also status flags are provided this way. For details please refer to the manufac
|
||||
|
||||
Based on that concept, errors, warnings and infos are provided in 3 different ways:
|
||||
|
||||
* As an unsigned integer value with the decimal representation of the encoded bits
|
||||
* The total number of encoded errors, warning or infos
|
||||
* The bit encoded as a string
|
||||
- As an unsigned integer value with the decimal representation of the encoded bits
|
||||
- The total number of encoded errors, warning or infos
|
||||
- The bit encoded as a string
|
||||
|
||||
Since there can potentially be several errors, warnings or infos, using a simple MAP to display the corresponding message in a UI will not work in all cases. String items with multiple lines will not display properly in the UIs.
|
||||
Therefore the binding provides actions to retrieve the different messages as an `ArrayList<String>` object which can then be used to e.g. send the messages via email.
|
||||
|
||||
|
||||
## Full Example
|
||||
|
||||
### Thing Configuration
|
||||
|
||||
```
|
||||
```java
|
||||
Bridge modbus:tcp:modbus-gateway "Modbus TCP/IP Gateway" [ host="192.168.47.11", port=502, id=180, enableDiscovery=true ] {
|
||||
Thing helios-easycontrols kwl "KWL"
|
||||
}
|
||||
@@ -356,7 +345,7 @@ Bridge modbus:tcp:modbus-gateway "Modbus TCP/IP Gateway" [ host="192.168.47.11",
|
||||
|
||||
### Item Configuration
|
||||
|
||||
```
|
||||
```java
|
||||
// Manual operation
|
||||
Number KWL_Manual "Manual operation" <fan> (gKWL) ["Control"] {channel="modbus:helios-easycontrols:modbus-gateway:kwl:operation#operatingMode"}
|
||||
Number KWL_Stage "KWL fan stage" <fan> (gKWL) ["Setpoint", "Level"] {channel="modbus:helios-easycontrols:modbus-gateway:kwl:operation#fanStage"}
|
||||
@@ -395,7 +384,7 @@ String KWL_Status_Flags "Status Flags [%s]"
|
||||
|
||||
### Rule
|
||||
|
||||
```
|
||||
```java
|
||||
import java.util.List
|
||||
import java.util.Map
|
||||
|
||||
@@ -427,7 +416,7 @@ end
|
||||
|
||||
### Transformation
|
||||
|
||||
```
|
||||
```text
|
||||
0=no
|
||||
1=yes
|
||||
OFF=no
|
||||
@@ -438,7 +427,7 @@ NULL=-
|
||||
|
||||
### Sitemap
|
||||
|
||||
```
|
||||
```perl
|
||||
Text label="KWL" icon="fan" {
|
||||
Frame label="Manual operation" {
|
||||
Selection item=KWL_Manual mappings=[0=Auto, 1=Manual]
|
||||
|
||||
Reference in New Issue