@@ -2,9 +2,9 @@
|
||||
|
||||
This extension adds support for the Studer protocol.
|
||||
|
||||
Studer Innotec, founded in 1987 by Roland Studer, is an ISO certified company that develops and manufactures inverters, inverter/chargers and MPPT solar charge controllers to communicate over the Modbus protocol entirely in Switzerland
|
||||
Studer Innotec, founded in 1987 by Roland Studer, is an ISO certified company that develops and manufactures inverters, inverter/chargers and MPPT solar charge controllers to communicate over the Modbus protocol entirely in Switzerland
|
||||
|
||||
For a list of certified products see this page: https://www.studer-innotec.com/
|
||||
For a list of certified products see this page: <https://www.studer-innotec.com/>
|
||||
|
||||
## Supported Things
|
||||
|
||||
@@ -18,7 +18,6 @@ Note, that the things will show up under the Modbus binding.
|
||||
| variotrack | For the VarioTrack models of MPPT solar charge controllers for systems with solar PV capacity from 1 - 75kWp |  |
|
||||
| variostring | For the VarioString models of MPPT solar charge controllers for systems with solar PV capacity from 4 |  |
|
||||
|
||||
|
||||
## Thing Configuration
|
||||
|
||||
You need first to set up a Serial Modbus bridge according to the Modbus documentation.
|
||||
@@ -46,7 +45,6 @@ More Details about that can be found in the technical specification and appendix
|
||||
|
||||
Multicast writes on any devices of given class, but reads only on the first available device (Not Summary!). As currently there are no writes available, 10/20/40 is useless for now.
|
||||
|
||||
|
||||
The following parameters are valid for all thing types:
|
||||
|
||||
| Parameter | Type | Required | Default if omitted | Description |
|
||||
@@ -58,7 +56,7 @@ The following parameters are valid for all thing types:
|
||||
|
||||
The following Channels, and their associated channel types are shown below divided by device.
|
||||
|
||||
#### BSP
|
||||
### BSP
|
||||
|
||||
All channels read for a BSP device
|
||||
|
||||
@@ -70,7 +68,7 @@ All channels read for a BSP device
|
||||
| stateOfCharge | Number:Dimensionless | State of Charge |
|
||||
| batteryTemperature | Number:Temperature | Battery temperature |
|
||||
|
||||
#### Xtender
|
||||
### Xtender
|
||||
|
||||
All channels read for a Xtender device
|
||||
|
||||
@@ -87,7 +85,7 @@ All channels read for a Xtender device
|
||||
| operatingState | String | Operating state |
|
||||
| stateInverter | String | State of the inverter |
|
||||
|
||||
#### VarioTrack
|
||||
### VarioTrack
|
||||
|
||||
All channels read for a VarioTrack device
|
||||
|
||||
@@ -102,7 +100,7 @@ All channels read for a VarioTrack device
|
||||
| operatingMode | String | Operating mode |
|
||||
| stateVarioTrack | String | State of the VarioTrack |
|
||||
|
||||
#### VarioString
|
||||
### VarioString
|
||||
|
||||
All channels read for a VarioString device
|
||||
|
||||
@@ -131,7 +129,7 @@ All channels read for a VarioString device
|
||||
|
||||
### Thing Configuration
|
||||
|
||||
```
|
||||
```java
|
||||
Bridge modbus:serial:bridge [port="/dev/ttyUSB0",baud=9600,dataBits=8,parity="even",stopBits="1.0",encoding="rtu"]
|
||||
..or..
|
||||
Bridge modbus:tcp:bridge [host="192.168.178.56", port=502, rtuEncoded=true]
|
||||
@@ -144,12 +142,11 @@ Thing modbus:variostring:bridge:variostring_right "Xtender" (modbus:serial:modbu
|
||||
Thing modbus:bsp:bridge:byd "BydBox" (modbus:serial:modbusbridge) [ slaveAddress=61, refresh=5 ]
|
||||
```
|
||||
|
||||
|
||||
Note: Make sure that refresh and slave address are numerical, without quotes.
|
||||
|
||||
### Item Configuration
|
||||
|
||||
```
|
||||
```java
|
||||
Number Studer_Xtender_Phase1_InputVoltage "Input Voltage [%.2f V]" {channel="modbus:xtender:bridge:xtender_Phase1:inputVoltage"}
|
||||
Number Studer_Xtender_Phase1_InputCurrent "Input Current [%.2f A]" {channel="modbus:xtender:bridge:xtender_Phase1:inputCurrent"}
|
||||
String Studer_Xtender_Phase1_StateInverter "State: [%s]" {channel="modbus:xtender:bridge:xtender_Phase1:stateInverter"}
|
||||
@@ -166,7 +163,7 @@ Number Studer_BSP_batteryVoltage "Battery Voltage: [%s]" {cha
|
||||
|
||||
### Sitemap Configuration
|
||||
|
||||
```
|
||||
```perl
|
||||
Text item=Studer_Xtender_Phase1_InputVoltage
|
||||