Fix http -> https where applyable. (#10573)
Signed-off-by: Jerome Luckenbach <github@luckenba.ch>
This commit is contained in:
committed by
GitHub
parent
8ba34392aa
commit
10f88c0934
@@ -1,10 +1,10 @@
|
||||
# LCN Binding
|
||||
|
||||
[Local Control Network (LCN)](http://www.lcn.eu) is a building automation system for small and very large installations.
|
||||
[Local Control Network (LCN)](https://www.lcn.eu) is a building automation system for small and very large installations.
|
||||
It is capable of controlling lights, shutters, access control etc. and can process data from several sensor types.
|
||||
It has been introduced in 1992.
|
||||
|
||||
A broad range of glass key panels, displays, remote controls, sensors and in- and outputs exist.
|
||||
A broad range of glass key panels, displays, remote controls, sensors and in- and outputs exist.
|
||||
The system can handle up to 30,000 bus members, called modules.
|
||||
LCN modules are available for DIN rail and in-wall mounting and feature versatile interfaces. The bus modules and most of the accessories are developed, manufactured and assembled in Germany.
|
||||
|
||||
@@ -43,7 +43,7 @@ Examples for PCK gateways are the *LCN-PCHK* software running on Windows or Linu
|
||||
|
||||
For each LCN bus, interfaced to openHAB, a PCK gateway needs to be added to openHAB as a *Thing*.
|
||||
|
||||
Several PCK gateways can be added to openHAB to control multiple LCN busses in distinct locations.
|
||||
Several PCK gateways can be added to openHAB to control multiple LCN busses in distinct locations.
|
||||
|
||||
The minimum recommended version is LCN-PCHK 2.8 (older versions will also work, but lack some functionality).
|
||||
Visit [https://www.lcn.eu](https://www.lcn.eu) for updates.
|
||||
@@ -197,7 +197,7 @@ The binary sensor Channels provide the boolean parameter `invertState`, which ca
|
||||
|
||||
LCN transponder readers or fingerprint readers can be integrated in openHAB e.g. for access control.
|
||||
The transponder function must be enabled in the module's I-port properties within *LCN-PRO*.
|
||||
|
||||
|
||||
Example: When the transponder card with the ID "12ABCD" is seen by the reader connected to LCN module "S000M011", the item "M10_Relay7" is switched on:
|
||||
|
||||
```
|
||||
@@ -296,7 +296,7 @@ When no *ramp* parameter is specified or no profile is configured, the ramp is 0
|
||||
The ramp parameter is not available for Color *Item*s.
|
||||
|
||||
```
|
||||
// Dim output 2 in 0.25s
|
||||
// Dim output 2 in 0.25s
|
||||
Switch M10_Output2 {channel="lcn:module:b827ebfea4bb:S000M010:output#2"[profile="lcn:output", ramp=0.25]} // with ramp of 0.25s (smallest value)
|
||||
// Dim output 3 in 486s
|
||||
Dimmer M10_Output3 {channel="lcn:module:b827ebfea4bb:S000M010:output#3"[profile="lcn:output", ramp=486]} // with ramp of 486s (biggest value)
|
||||
@@ -386,7 +386,7 @@ This action has also effect, if the given output is off. The output will be dimm
|
||||
```
|
||||
rule "Flicker output 1 when window opens"
|
||||
when
|
||||
Item M10_BinarySensor5 changed to OPEN
|
||||
Item M10_BinarySensor5 changed to OPEN
|
||||
then
|
||||
val actions = getActions("lcn","lcn:module:b827ebfea4bb:S000M010")
|
||||
// output=1, depth=2=100%, ramp=0=2s, count=3
|
||||
@@ -407,7 +407,7 @@ When programming a "Relay Timer" *Action*, the following parameters need to be s
|
||||
```
|
||||
rule "Start relay timer for led driver when dummy switch changed"
|
||||
when
|
||||
Item Dummy_Switch changed
|
||||
Item Dummy_Switch changed
|
||||
then
|
||||
val actions = getActions("lcn","lcn:module:b827ebfea4bb:17B4196847")
|
||||
// relayNumber=3, duration=90
|
||||
@@ -429,7 +429,7 @@ Config `.things`
|
||||
```
|
||||
Bridge lcn:pckGateway:myPCHK [ hostname="192.168.123.123", port=4114, username="myUser", password="myPassword", mode="native200" ] {
|
||||
Thing module M99 "M99 MyModule" [ moduleId=99, segmentId=0 ] {
|
||||
Channels:
|
||||
Channels:
|
||||
Rollershutter : rollershutterrelay#1 "My twisted rollershutter relay" [ invertUpDown = true ]
|
||||
Contact : binarysensor#6 [ invertState=true ]
|
||||
Number : rvarsetpoint#1 [ unit="temperature" ]
|
||||
@@ -455,7 +455,7 @@ Dimmer M10_OutputAll3 {channel="lcn:module:b827ebfea4bb:S000M010:output#1"[profi
|
||||
Dimmer M10_Outputs12b {channel="lcn:module:b827ebfea4bb:S000M010:output#1"[profile="lcn:output", controlOutputs12=true, ramp=0.25]}
|
||||
|
||||
// Dimmer Outputs: RGB Control
|
||||
Color M10_Color {channel="lcn:module:b827ebfea4bb:S000M010:output#color"[profile="lcn:output"]}
|
||||
Color M10_Color {channel="lcn:module:b827ebfea4bb:S000M010:output#color"[profile="lcn:output"]}
|
||||
|
||||
// Roller Shutter on Output 1+2
|
||||
Rollershutter M10_RollershutterOutput1 {channel="lcn:module:b827ebfea4bb:S000M010:rollershutteroutput#1"}
|
||||
@@ -520,39 +520,39 @@ sitemap lcn label="My home automation" {
|
||||
Default item=M10_Output1 label="Output 1"
|
||||
Default item=M10_Output2 label="Output 2"
|
||||
Default item=M10_Output3 label="Output 3"
|
||||
|
||||
|
||||
// Dimmer Outputs: Control all simultaneously. Status of Output 1 is visualized.
|
||||
Default item=M10_OutputAll1 label="All Outputs ramp=0 since firmware 180501"
|
||||
Default item=M10_OutputAll2 label="All Outputs ramp=250ms all firmwares"
|
||||
Default item=M10_OutputAll3 label="All Outputs ramp>=500ms since firmware 180501"
|
||||
|
||||
|
||||
// Dimmer Outputs: Control outputs 1+2 simultaneously. Status of Output 1 is visualized. Only ramps of 0s or 0.25s are supported.
|
||||
Default item=M10_Outputs12a label="Outputs 1+2 Ramp=0"
|
||||
Default item=M10_Outputs12b label="Outputs 1+2 Ramp=0.25s"
|
||||
|
||||
|
||||
// Dimmer Outputs: RGB Control
|
||||
Colorpicker item=M10_Color
|
||||
|
||||
|
||||
// Roller Shutter on Outputs 1+2
|
||||
Default item=M10_RollershutterOutput1 label="Roller Shutter on Output 1+2"
|
||||
|
||||
|
||||
// Relays
|
||||
Default item=M10_Relay1 label="Relay 1"
|
||||
|
||||
|
||||
// Roller Shutter on Relays
|
||||
Default item=M10_RollershutterRelay1 label="Roller Shutter on Relay 1-2"
|
||||
|
||||
|
||||
// LEDs
|
||||
Switch item=M10_LED1 label="LED 1" mappings=[ON=ON, OFF=OFF] // Don't display "Blink" or "Flicker"
|
||||
Switch item=M10_LED2 label="LED 2"
|
||||
|
||||
|
||||
// Logic Operations (legacy name: "Sums")
|
||||
Default item=M10_Logic1 label="Logic Operation 1"
|
||||
Default item=M10_Logic2 label="Logic Operation 2"
|
||||
|
||||
|
||||
// Binary Sensors (Channels 1-3 of LCN-B3I are mapped to BinarySensor6, BinarySensor7, BinarySensor8)
|
||||
Default item=M10_BinarySensor1 label="Binary Sensor 1"
|
||||
|
||||
Default item=M10_BinarySensor1 label="Binary Sensor 1"
|
||||
|
||||
// Variables
|
||||
Setpoint item=M10_Variable1 label="Variable 1"
|
||||
Default item=M10_Variable2 label="Variable 2"
|
||||
@@ -565,21 +565,21 @@ sitemap lcn label="My home automation" {
|
||||
Default item=M10_Variable9 label="Variable 9"
|
||||
Default item=M10_Variable10 label="Variable 10"
|
||||
Default item=M10_Variable11 label="Variable 11"
|
||||
|
||||
|
||||
// Regulators
|
||||
Setpoint item=M10_R1VarSetpoint label="R1Var Setpoint" step=1 minValue=-10.0
|
||||
Default item=M10_R1VarLock label="R1Var Lock" // Lock state of R1Var
|
||||
|
||||
|
||||
// Thresholds
|
||||
Setpoint item=M10_ThresholdRegister1_Threshold1 label="Threshold Register 1 Threshold 1"
|
||||
Setpoint item=M10_ThresholdRegister4_Threshold2 label="Threshold Register 4 Threshold 2"
|
||||
|
||||
|
||||
// S0 Counters
|
||||
Default item=M10_S0Counter1 label="S0 Counter 1"
|
||||
|
||||
|
||||
// Key Locks
|
||||
Default item=M10_KeyLockA1 label="Locked State Key A1"
|
||||
Default item=M10_KeyLockD5 label="Locked State Key D5"
|
||||
}
|
||||
}
|
||||
}
|
||||
```
|
||||
|
||||
Reference in New Issue
Block a user