[Documentation] Markdown improvements n to s (#13948)
Signed-off-by: Jerome Luckenbach <github@luckenba.ch>
This commit is contained in:
committed by
GitHub
parent
d73218d882
commit
1ca9baf157
@@ -22,7 +22,7 @@ Auto-Discovery is not supported, as credentials are necessary to login into Nibe
|
||||
|
||||
The syntax for a heat pump thing is:
|
||||
|
||||
```
|
||||
```java
|
||||
nibeuplink:<THING TYPE>:<NAME>
|
||||
```
|
||||
|
||||
@@ -50,7 +50,7 @@ username used to login on NibeUplink
|
||||
password used to login on NibeUplink
|
||||
|
||||
- **nibeId** (required)
|
||||
Id of your heatpump in NibeUplink (can be found in the URL after successful login: https://www.nibeuplink.com/System/**<nibeId>>**/Status/Overview)
|
||||
Id of your heatpump in NibeUplink (can be found in the URL after successful login: `https://www.nibeuplink.com/System/**<nibeId>>**/Status/Overview`)
|
||||
|
||||
- **pollingInterval**
|
||||
interval (seconds) in which values are retrieved from NibeUplink.
|
||||
@@ -65,19 +65,19 @@ Usually this settings should not be changed.
|
||||
|
||||
- minimum configuration
|
||||
|
||||
```
|
||||
```java
|
||||
nibeuplink:vvm320:mynibe [ user="...", password="...", nibeId="..."]
|
||||
```
|
||||
|
||||
- with pollingInterval
|
||||
|
||||
```
|
||||
```java
|
||||
nibeuplink:vvm320:mynibe[ user="...", password="...", nibeId="...", pollingInterval=... ]
|
||||
```
|
||||
|
||||
- multiple heat pumps
|
||||
|
||||
```
|
||||
```java
|
||||
nibeuplink:vvm320:home1 [ user="...", password="...", nibeId="..."]
|
||||
nibeuplink:vvm320:home2 [ user="...", password="...", nibeId="..."]
|
||||
```
|
||||
@@ -196,7 +196,7 @@ Following models/channels are currently available:
|
||||
| compressor#43439 | Number:Dimensionless | 0 | 100 | No | EP14-GP2 Brine Pump Speed | |
|
||||
| airsupply#40025 | Number:Temperature | -32767 | 32767 | No | BT20 Exhaust air temp. 1 | |
|
||||
| airsupply#40026 | Number:Temperature | -32767 | 32767 | No | BT21 Vented air temp. 1 | |
|
||||
|
||||
|
||||
### F1155 / 1255
|
||||
|
||||
| Channel Type ID | Item Type | Min | Max | Writable | Description | Allowed Values (write access) |
|
||||
@@ -309,12 +309,11 @@ There are three custom channel types available, which allow different scaling of
|
||||
- type-number-scale10
|
||||
- type-number-scale100
|
||||
|
||||
|
||||
## Full Example
|
||||
|
||||
### Thing
|
||||
|
||||
```
|
||||
```java
|
||||
nibeuplink:vvm320:mynibe [ user="nibe@my-domain.de", password="secret123", nibeId="4711", pollingInterval=300] {
|
||||
Channels:
|
||||
Type type-number-scale10 : 47015 "min supply temp heating"
|
||||
@@ -330,7 +329,7 @@ Channels which represent two states (such as on/off) are represented as Switch.
|
||||
Channels which have more than two states are internally represented as number.
|
||||
You need to define a map file which also gives you the opportunity to translate the state into your preferred language.
|
||||
|
||||
```
|
||||
```java
|
||||
Number:Temperature NIBE_SUPPLY "Vorlauf" { channel="nibeuplink:vvm320:mynibe:base#40008" }
|
||||
Number:Temperature NIBE_RETURN "Rücklauf [%.2f °F]" { channel="nibeuplink:vvm320:mynibe:base#40012" }
|
||||
Number:Temperature NIBE_HW_TOP "Brauchwasser oben" { channel="nibeuplink:vvm320:mynibe:hotwater#40013" }
|
||||
@@ -346,19 +345,18 @@ Number NIBE_MIN_SUP_COOL "min supply temp. cooling [%d °C
|
||||
|
||||
Please define each state as integer.
|
||||
|
||||
```
|
||||
```text
|
||||
0=Eco
|
||||
1=Norm
|
||||
2=Lux
|
||||
```
|
||||
|
||||
|
||||
### Sitemaps
|
||||
|
||||
Please take care of the status channels.
|
||||
If you use selection items an automatic mapping will be applied.
|
||||
If you prefer switch items a mapping must be applied like this:
|
||||
|
||||
```
|
||||
```java
|
||||
Switch item=NIBE_HW_MODE mappings=[0="Eco", 1="Norm"]
|
||||
```
|
||||
|
||||
Reference in New Issue
Block a user