[somfytahoma] Added support for the thermostatic valve (#9122)
Signed-off-by: Ondrej Pecta <opecta@gmail.com>
This commit is contained in:
@@ -31,6 +31,7 @@ home automation systems.
|
||||
- electricity sensors (get energy consumption)
|
||||
- door locks (LOCK/UNLOCK, OPEN/CLOSE commands)
|
||||
- heating systems (control temperature, set heating level)
|
||||
- valve heating systems (control temperature, derogation mode and temperature)
|
||||
- exterior heating systems (set heating level)
|
||||
- alarms (both interior/external)
|
||||
- pods
|
||||
@@ -62,63 +63,67 @@ Please see the example below.
|
||||
|
||||
## Channels
|
||||
|
||||
| Thing | Channel | Note |
|
||||
|-------------------------------------------------------------------------------|:---------------------:|-------------------------------------------------------------------------------------------------------------------------------|
|
||||
| bridge | N.A | bridge does not expose any channel |
|
||||
| gateway | status | status of your Tahoma gateway |
|
||||
| gate | gate_command | used for controlling your gate (open, close, stop, pedestrian) |
|
||||
| gate | gate_state | get state of your gate |
|
||||
| roller shutter, screen, venetian blind, garage door, awning, pergola, curtain | control | device controller which reacts to commands UP/DOWN/ON/OFF/OPEN/CLOSE/MY/STOP + closure 0-100 |
|
||||
| window | control | device controller which reacts to commands UP/DOWN/ON/OFF/OPEN/CLOSE/STOP + closure 0-100 |
|
||||
| silent roller shutter | silent_control | similar to control channel but in silent mode |
|
||||
| venetian blind, adjustable slats roller shutter | orientation | percentual orientation of the blind's slats, it can have value 0-100. For IO Homecontrol devices only (non RTS) |
|
||||
| venetian blind, adjustable slats roller shutter | closure_orientation | percentual closure and orientation of the blind's slats, it can have value 0-100. For IO Homecontrol devices only (non RTS) |
|
||||
| adjustable slats roller shutter | rocker | used for setting the rocker position of the roller shutter, the only position allowing the slats control |
|
||||
| action group | execute_action | switch which reacts to ON command and triggers the predefined Tahoma action |
|
||||
| onoff, light | switch | reacts to standard ON/OFF commands |
|
||||
| dimmer light | light_intensity | sets/gets intensity of the dimmer light or ON/OFF |
|
||||
| smoke sensor, occupancy sensor, contact sensor & water sensor | contact | normal value is CLOSE, changes to OPEN when detection triggered |
|
||||
| smoke sensor, occupancy sensor, contact sensor & water sensor | sensor_defect | indicates the health of the sensor (dead, lowBatter, maintenanceRequired, noDefect) |
|
||||
| smoke sensor | radio_battery | maintenance radio part battery state (low, normal) |
|
||||
| smoke sensor | sensor_battery | maintenance sensor part battery state (absence, low, normal) |
|
||||
| smoke sensor | short_check | triggering the smoke sensor's short check |
|
||||
| smoke sensor | long_check | triggering the smoke sensor's long check |
|
||||
| light sensor | luminance | light luminance value in luxes |
|
||||
| electricity sensor | energy_consumption | energy consumption value in watts |
|
||||
| humidity sensor | humidity | current relative humidity |
|
||||
| dock | battery_status | indicates running on battery (yes/no) |
|
||||
| dock | battery_level | remaining battery percentage |
|
||||
| dock | siren_status | used for controlling and getting siren state (on, off, cyclic) |
|
||||
| dock | short_beep | testing of dock's siren - short beep |
|
||||
| dock | long_beep | testing of dock's siren - long beep |
|
||||
| siren | battery | battery level full/low/normal/verylow |
|
||||
| siren | onoff | controlling siren status ON/OFF |
|
||||
| siren | memorized_volume | setting memorized volume (normal/highest) |
|
||||
| pod | cyclic_button | pod cyclic button state |
|
||||
| pod | battery_status | pod battery status state |
|
||||
| pod | lighting_led_pod_mode | lighting LED pod mod state |
|
||||
| interior alarm | alarm_command | used for sending commands to Somfy alarm device |
|
||||
| interior alarm | intrusion_control | used for alarm external intrusion controlling |
|
||||
| interior alarm, myfox alarm | alarm_state | state of the Somfy alarm |
|
||||
| interior alarm | target_alarm_state | target state of the Somfy alarm |
|
||||
| interior alarm, myfox alarm | intrusion_state | intrusion state of the Somfy alarm |
|
||||
| external alarm | active_zones_state | state of external alarm active zones |
|
||||
| door lock | lock | switch representing unlocked/locked state |
|
||||
| door lock | open | switch representing open/close state |
|
||||
| on/off heating system | target_heating_level | target heating level (off, eco, comfort, frostprotection) |
|
||||
| heating system | current_temperature | current temperature of the heating system |
|
||||
| heating system | current_state | current state of the heating system |
|
||||
| heating system, thermostat | target_temperature | target temperature of the heating system |
|
||||
| heating system, thermostat | battery_level | battery level of the heating system |
|
||||
| exterior heating system | heating_level | heating level of the exterior heating system or ON/OFF |
|
||||
| thermostat | heating_mode | standard heating mode of the thermostat (away, freeze, manual, ...) |
|
||||
| thermostat | derogation_heating_mode | derogation heating mode of the thermostat (away, freeze, manual, ...) |
|
||||
| thermostat | derogation_activation | derogation activation state (inactive, active) |
|
||||
| temperature sensor | temperature | temperature reported by the sensor |
|
||||
| myfox camera, myfox alarm | cloud_status | cloud connection status |
|
||||
| myfox camera | shutter | controlling of the camera shutter |
|
||||
| myfox alarm | myfox_alarm_command | used for sending commands to Somfy Myfox alarm device |
|
||||
|
||||
| Thing | Channel | Note |
|
||||
|-------------------------------------------------------------------------------|------------------------------|-----------------------------------------------------------------------------------------------------------------------------|
|
||||
| bridge | N.A | bridge does not expose any channel |
|
||||
| gateway | status | status of your Tahoma gateway |
|
||||
| gate | gate_command | used for controlling your gate (open, close, stop, pedestrian) |
|
||||
| gate | gate_state | get state of your gate (open, closed, pedestrian) |
|
||||
| gate | gate_position | get position (0-100%) of your gate (where supported) |
|
||||
| roller shutter, screen, venetian blind, garage door, awning, pergola, curtain | control | device controller which reacts to commands UP/DOWN/ON/OFF/OPEN/CLOSE/MY/STOP + closure 0-100 |
|
||||
| window | control | device controller which reacts to commands UP/DOWN/ON/OFF/OPEN/CLOSE/STOP + closure 0-100 |
|
||||
| silent roller shutter | silent_control | similar to control channel but in silent mode |
|
||||
| venetian blind, adjustable slats roller shutter | orientation | percentual orientation of the blind's slats, it can have value 0-100. For IO Homecontrol devices only (non RTS) |
|
||||
| venetian blind, adjustable slats roller shutter | closure_orientation | percentual closure and orientation of the blind's slats, it can have value 0-100. For IO Homecontrol devices only (non RTS) |
|
||||
| adjustable slats roller shutter | rocker | used for setting the rocker position of the roller shutter, the only position allowing the slats control |
|
||||
| action group | execute_action | switch which reacts to ON command and triggers the predefined Tahoma action |
|
||||
| onoff, light | switch | reacts to standard ON/OFF commands |
|
||||
| dimmer light | light_intensity | sets/gets intensity of the dimmer light or ON/OFF |
|
||||
| smoke sensor, occupancy sensor, contact sensor & water sensor | contact | normal value is CLOSE, changes to OPEN when detection triggered |
|
||||
| smoke sensor, occupancy sensor, contact sensor & water sensor | sensor_defect | indicates the health of the sensor (dead, lowBatter, maintenanceRequired, noDefect) |
|
||||
| smoke sensor | radio_battery | maintenance radio part battery state (low, normal) |
|
||||
| smoke sensor | sensor_battery | maintenance sensor part battery state (absence, low, normal) |
|
||||
| smoke sensor | short_check | triggering the smoke sensor's short check |
|
||||
| smoke sensor | long_check | triggering the smoke sensor's long check |
|
||||
| light sensor | luminance | light luminance value in luxes |
|
||||
| electricity sensor | energy_consumption | energy consumption value in watts |
|
||||
| humidity sensor | humidity | current relative humidity |
|
||||
| dock | battery_status | indicates running on battery (yes/no) |
|
||||
| dock | battery_level | remaining battery percentage |
|
||||
| dock | siren_status | used for controlling and getting siren state (on, off, cyclic) |
|
||||
| dock | short_beep | testing of dock's siren - short beep |
|
||||
| dock | long_beep | testing of dock's siren - long beep |
|
||||
| siren | battery | battery level full/low/normal/verylow |
|
||||
| siren | onoff | controlling siren status ON/OFF |
|
||||
| siren | memorized_volume | setting memorized volume (normal/highest) |
|
||||
| pod | cyclic_button | pod cyclic button state |
|
||||
| pod | battery_status | pod battery status state |
|
||||
| pod | lighting_led_pod_mode | lighting LED pod mod state |
|
||||
| interior alarm | alarm_command | used for sending commands to Somfy alarm device |
|
||||
| interior alarm | intrusion_control | used for alarm external intrusion controlling |
|
||||
| interior alarm, myfox alarm | alarm_state | state of the Somfy alarm |
|
||||
| interior alarm | target_alarm_state | target state of the Somfy alarm |
|
||||
| interior alarm, myfox alarm | intrusion_state | intrusion state of the Somfy alarm |
|
||||
| external alarm | active_zones_state | state of external alarm active zones |
|
||||
| door lock | lock | switch representing unlocked/locked state |
|
||||
| door lock | open | switch representing open/close state |
|
||||
| on/off heating system | target_heating_level | target heating level (off, eco, comfort, frostprotection) |
|
||||
| heating system | current_temperature | current temperature of the heating system |
|
||||
| heating system | current_state | current state of the heating system |
|
||||
| heating system, valve heating system, thermostat | target_temperature | target temperature of the heating system |
|
||||
| heating system, valve heating system, thermostat | battery_level | battery level of the heating system |
|
||||
| valve heating system, thermostat | derogation_heating_mode | derogation heating mode of the thermostat (away, freeze, manual, ...) |
|
||||
| valve heating system, thermostat | derogated_target_temperature | target temperature of the heating system |
|
||||
| valve heating system | current_heating_mode | current heating mode of the thermostatic valve |
|
||||
| valve heating system | open_closed_valve | current open/closed state of the thermostatic valve |
|
||||
| valve heating system | operating mode | operating mode of the thermostatic valve |
|
||||
| thermostat | heating_mode | standard heating mode of the thermostat (away, freeze, manual, ...) |
|
||||
| thermostat | derogation_activation | derogation activation state (inactive, active) |
|
||||
| exterior heating system | heating_level | heating level of the exterior heating system or ON/OFF |
|
||||
| temperature sensor | temperature | temperature reported by the sensor |
|
||||
| myfox camera, myfox alarm | cloud_status | cloud connection status |
|
||||
| myfox camera | shutter | controlling of the camera shutter |
|
||||
| myfox alarm | myfox_alarm_command | used for sending commands to Somfy Myfox alarm device |
|
||||
|
||||
### Remarks
|
||||
|
||||
|
||||
Reference in New Issue
Block a user