From 2519ec7236a4f998fb1b63ad4b41c00b280f799d Mon Sep 17 00:00:00 2001 From: M Valla <12682715+mvalla@users.noreply.github.com> Date: Thu, 6 Oct 2022 08:33:01 +0200 Subject: [PATCH] [openwebnet] add support for basic Scenarios (WHO=0) (#13473) * [openwebnet] added first support for WHO=0 scenarios * [openwebnet] channels indent * [openwebnet] formatting * [openwebnet] set WHO=0 thing online automatically. Update to openwebnet4j 0.9.0 Signed-off-by: Massimo Valla --- .../org.openhab.binding.openwebnet/README.md | 103 +++++++++++------- .../org.openhab.binding.openwebnet/pom.xml | 2 +- .../internal/OpenWebNetBindingConstants.java | 21 ++-- .../internal/OpenWebNetHandlerFactory.java | 6 +- .../OpenWebNetDeviceDiscoveryService.java | 6 + .../handler/OpenWebNetBridgeHandler.java | 9 +- .../OpenWebNetScenarioBasicHandler.java | 95 ++++++++++++++++ .../handler/OpenWebNetThingHandler.java | 7 +- .../OH-INF/i18n/openwebnet.properties | 48 +++++++- .../OH-INF/thing/BusBasicScenarioControl.xml | 36 ++++++ .../main/resources/OH-INF/thing/channels.xml | 56 ++++++++-- .../internal/handler/OwnIdTest.java | 9 +- 12 files changed, 321 insertions(+), 77 deletions(-) create mode 100644 bundles/org.openhab.binding.openwebnet/src/main/java/org/openhab/binding/openwebnet/internal/handler/OpenWebNetScenarioBasicHandler.java create mode 100644 bundles/org.openhab.binding.openwebnet/src/main/resources/OH-INF/thing/BusBasicScenarioControl.xml diff --git a/bundles/org.openhab.binding.openwebnet/README.md b/bundles/org.openhab.binding.openwebnet/README.md index dd76f8581..d03229e9b 100644 --- a/bundles/org.openhab.binding.openwebnet/README.md +++ b/bundles/org.openhab.binding.openwebnet/README.md @@ -44,8 +44,8 @@ The following Things and OpenWebNet `WHOs` are supported: | Lighting | `1` | `bus_on_off_switch`, `bus_dimmer` | BUS switches and dimmers | Successfully tested: F411/2, F411/4, F411U2, F422, F429. Some discovery issues reported with F429 (DALI Dimmers) | | Automation | `2` | `bus_automation` | BUS roller shutters, with position feedback and auto-calibration | Successfully tested: LN4672M2 | | Temperature Control | `4` | `bus_thermo_zone`, `bus_thermo_sensor`, `bus_thermo_cu` | Thermo zones management and temperature sensors (probes). | Successfully tested: H/LN4691, HS4692, KG4691; thermo sensors: L/N/NT4577 + 3455; Central Units (4 or 99 zones) are not fully supported yet. See [Channels - Thermo](#configuring-thermo) for more details | -| Auxiliary (AUX) | `9` | `bus_aux` | AUX commands | Successfully tested: AUX configured for bulgrar-alarm unit 3486. Only sending AUX commands is supported | -| CEN & CEN+ Scenarios | `15` & `25` | `bus_cen_scenario_control`, `bus_cenplus_scenario_control` | CEN/CEN+ scenarios events and virtual activation | Successfully tested: scenario buttons: HC/HD/HS/L/N/NT4680 | +| Auxiliary (AUX) | `9` | `bus_aux` | AUX commands | Successfully tested: AUX configured for bulgrar-alarm unit 3486. **Only sending AUX commands is supported** | +| Basic, CEN & CEN+ Scenarios | `0`, `15`, `25` | `bus_scenario_control`, `bus_cen_scenario_control`, `bus_cenplus_scenario_control` | Basic and CEN/CEN+ Scenarios events and virtual activation | Successfully tested: CEN/CEN+ scenario control: HC/HD/HS/L/N/NT4680 and basic scenario modules F420/IR3456 + L4680 (WHO=0) | | Dry Contact and IR Interfaces | `25` | `bus_dry_contact_ir` | Dry Contacts and IR Interfaces | Successfully tested: contact interfaces F428 and 3477; IR sensors: HC/HD/HS/L/N/NT4610 | | Energy Management | `18` | `bus_energy_meter` | Energy Management | Successfully tested: F520, F521. Partially tested: F522, F523 | @@ -69,13 +69,14 @@ For other gateways you can add them manually, see [Thing Configuration](#thing-c - Once the gateway is online, a second Inbox Scan will discover BUS devices - BUS/SCS Dimmers must be ON and dimmed (30%-100%) during a Scan, otherwise they will be discovered as simple On/Off switches - *KNOWN ISSUE*: In some cases dimmers connected to a F429 Dali-interface are not automatically discovered -- CEN/CEN+ Scenario Control devices will be discovered by activation only. See [discovery by activation](#discovery-by-activation) for details. After confirming a discovered CEN/CEN+ device from Inbox, activate again its scenario buttons to add button channels automatically +- Basic Scenario modules and CEN/CEN+ Scenario Control devices will be discovered by activation only. See [discovery by activation](#discovery-by-activation) for details. After confirming a discovered CEN/CEN+ scenario device from Inbox, activate again its buttons to add button channels automatically #### Discovery by Activation -BUS devices can also be discovered if activated while an Inbox Scan is active: start a new Scan, wait 15-20 seconds and then _while the Scan is still active_, activate the physical device (for example dim the dimmer) to have it discovered by the binding. +BUS devices can also be discovered if they are activated while an Inbox Scan has been started: start a new Scan, wait 15-20 seconds and then _while the Scan is still active_, activate the physical device (for example dim the dimmer) to have it discovered by the binding. +Setting the parameter `discoveryByActivation=true` for a BUS gateway Thing makes discovery by activation always working also when a Inbox Scan hasn't been started. -If a device cannot be discovered automatically it's always possible to add it manually, see [Configuring Devices](#configuring-devices). +If a device cannot be discovered automatically from Inbox it's always possible to add it manually, see [Configuring Devices](#configuring-devices). ### ZigBee Discovery @@ -105,7 +106,7 @@ Configuration parameters are: - Example: `abcde` or `12345` - if the BUS/SCS gateway is configured to accept connections from the openHAB computer IP address, no password should be required - in all other cases, a password must be configured. This includes gateways that have been discovered and added from Inbox: without a password configured they will remain OFFLINE -- `discoveryByActivation`: discover BUS devices when they are activated also when a device scan is not currently active (`boolean`, *optional*, default: `false`). See [Discovery by Activation](#discovery-by-activation). +- `discoveryByActivation`: discover BUS devices when they are activated also when a device scan hasn't been started from Inbox (`boolean`, *optional*, default: `false`). See [Discovery by Activation](#discovery-by-activation). Alternatively the BUS/SCS Gateway thing can be configured using the `.things` file, see `openwebnet.things` example [below](#full-example). @@ -129,6 +130,7 @@ For any manually added device, you must configure: - example for BUS/SCS system: - light device A=`2` (Area 2), PL=`4` (Light-point 4) --> `where="24"` - light device A=`03`, PL=`11` on local bus `01` --> `where="0311#4#01"` + - scenario control module address `53` --> `where="53"` - CEN scenario A=`05`, PL=`12` --> `where="0512"` - CEN+ scenario `5`: add `2` before --> `where="25"` - Dry Contact or IR Interface `99`: add `3` before --> `where="399"` @@ -155,6 +157,12 @@ Temperature sensors can be configured defining a `bus_thermo_sensor` Thing with The (optional) Central Unit can be configured defining a `bus_themo_cu` Thing. +##### Central Unit integration missing points + +- Read setPoint temperature and current mode +- Holiday activation command (all zones) +- Discovery + #### Configuring Auxiliary (AUX) **NOTE** Receiving AUX messages originating from the BUS is not supported yet, only sending messages to the BUS is supported. @@ -170,11 +178,11 @@ To configure Alarm Control Automations go to the menu: ##### Example configuration Automation 1: when AUX-1 goes OFF, then DISENGAGE all Zones -With this configuration when AUX `where=1` goes OFF, the Alarm will execute the automantion and send command `*5*9##` to DISENGAGE all zones. +With this configuration when AUX `where=1` goes OFF, the Alarm will execute the automation and send command `*5*9##` to DISENGAGE all zones. Name: Disengage all zones - Event: command OPEN = `*9*0*1##` - OPEN command to execute: `*5*9##` + Event: command OPEN = *9*0*1## + OPEN command to execute: *5*9## ##### Example configuration Automation 2: when AUX-2 goes ON, then ENGAGE active Zones @@ -188,28 +196,25 @@ With this configuration when AUX `where=1` goes OFF, the Alarm will execute the Event: command OPEN = *9*1*4## OPEN command to execute: *5*8#1234## -### Central Unit integration missing points - -- Read setPoint temperature and current mode -- Holiday activation command (all zones) -- Discovery - ## Channels -### Lighting, Automation, Power meter, CEN/CEN+ Scenario Events and Dry Contact / IR Interfaces channels +### Lighting, Automation, Power meter, Basic/CEN/CEN+ Scenario Events and Dry Contact / IR Interfaces channels | Channel Type ID (channel ID) | Applies to Thing Type IDs | Item Type | Description | Read/Write | |-----------------------------------------|---------------------------------------------------------------|---------------|-------------------------------------------------------------------------------------------------------------------------------------------------|:-----------:| | `switch` or `switch_01`/`02` for ZigBee | `bus_on_off_switch`, `zb_on_off_switch`, `zb_on_off_switch2u` | Switch | To switch the device `ON` and `OFF` | R/W | | `brightness` | `bus_dimmer`, `zb_dimmer` | Dimmer | To adjust the brightness value (Percent, `ON`, `OFF`) | R/W | | `shutter` | `bus_automation` | Rollershutter | To activate roller shutters (`UP`, `DOWN`, `STOP`, Percent - [see Shutter position](#shutter-position)) | R/W | -| `button#X` | `bus_cen_scenario_control`, `bus_cenplus_scenario_control` | String | Trigger channel for CEN/CEN+ scenario events [see possible values](#cen-cen-channels) | R (TRIGGER) | +| `button#X` | `bus_cen_scenario_control`, `bus_cenplus_scenario_control` | String | Trigger channel for CEN/CEN+ scenario events [see possible values](#scenario-channels) | R (TRIGGER) | | `sensor` | `bus_dry_contact_ir` | Switch | Indicates if a Dry Contact Interface is `ON`/`OFF`, or if a IR Sensor is detecting movement (`ON`), or not (`OFF`) | R | | `power` | `bus_energy_meter` | Number:Power | The current active power usage from Energy Meter | R | | `aux` | `bus_aux` | String | Possible commands: `ON`, `OFF`, `TOGGLE`, `STOP`, `UP`, `DOWN`, `ENABLED`, `DISABLED`, `RESET_GEN`, `RESET_BI`, `RESET_TRI`. Only `ON` and `OFF` are supported for now | R/W | +| `scenario`   | `bus_scenario_control` | String | Trigger channel for Basic scenario events [see possible values](#scenario-channels) | R (TRIGGER) | ### Thermo channels +**NOTE** Channels marked with Advanced=Y can be shown from Thing configuration > Channels tab > check `Show advanced`. + | Channel Type ID (channel ID) | Applies to Thing Type IDs | Item Type | Description | Read/Write | Advanced | | ---------------------------- | -------------------------------------- | ------------------ | --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | :--------: | :------: | | `temperature` | `bus_thermo_zone`, `bus_thermo_sensor` | Number:Temperature | The zone currently sensed temperature | R | N | @@ -243,40 +248,41 @@ It's possible to enter a value manually or set `shutterRun=AUTO` (default) to ca - if OH is restarted the binding does not know if a shutter position has changed in the meantime, so its position will be `UNDEF`. Move the shutter all `UP`/`DOWN` to synchronize again its position with the binding - the shutter position is estimated based on UP/DOWN timing: an error of ±2% is normal -#### CEN/CEN+ channels +#### Scenario channels -CEN/CEN+ are [TRIGGER channels](https://www.openhab.org/docs/configuration/rules-dsl.html#channel-based-triggers]): they handle events and do not have a state. +Basic Scenarios and CEN/CEN+ Scenarios channels are [TRIGGER channels](https://www.openhab.org/docs/configuration/rules-dsl.html#channel-based-triggers]): they handle events and do not have a state. -A powerful feature is to be able to assign CEN or CEN+ commands to your physical wall switches and use the events they generate to trigger rules in openHAB: this way openHAB becomes a very powerful scenario manager activated by physical BTicino switches. -See [openwebnet.rules](#openwebnet-rules) for an example on how to define rules that trigger on CEN/CEN+ buttons events. +A powerful feature is to detect scenario activations and CEN/CEN+ buttons press events to trigger rules in openHAB: this way openHAB becomes a very powerful scenario manager activated by BTicino scenario control modules or by CEN/CEN+ scenarios physical buttons. +See [openwebnet.rules](#openwebnet-rules) for examples on how to define rules that trigger on scenarios and on CEN/CEN+ button press events. -It's also possible to send *virtual press* events on the BUS, for example to enable the activation of MH202 scenarios from openHAB. -See [openwebnet.sitemap](#openwebnet-sitemap) & [openwebnet.rules](#openwebnet-rules) sections for an example on how to use the `virtualPress` action connected to a pushbutton on a sitemap. +It's also possible to send *virtual scenario activation* and *virtual press* events on the BUS, for example to enable the activation of MH202 or F420 scenarios from openHAB.. +See [openwebnet.sitemap](#openwebnet-sitemap) & [openwebnet.rules](#openwebnet-rules) sections for examples on how to use the `activateScenario` and `virtualPress` actions connected to a pushbutton on a sitemap. -- channels are named `button#X` where `X` is the button number on the Scenario Control device -- in the .thing file configuration you can specify the `buttons` parameter to define a comma-separated list of buttons numbers [0-31] configured for the scenario device, example: `buttons=1,2,4` -- possible events are: - - for CEN: - - `START_PRESS` - sent when you start pressing the button - - `SHORT_PRESS` - sent if you pressed the button shorter than 0,5sec (sent at the moment when you release it) - - `EXTENDED_PRESS` - sent if you keep the button pressed longer than 0,5sec; will be sent again every 0,5sec as long as you hold pressed (good for dimming rules) - - `RELEASE_EXTENDED_PRESS` - sent once when you finally release the button after having it pressed longer than 0,5sec - - for CEN+: - - `SHORT_PRESS` - sent if you pressed the button shorter than 0,5sec (sent at the moment when you release it) - - `START_EXTENDED_PRESS` - sent once as soon as you keep the button pressed longer than 0,5sec - - `EXTENDED_PRESS` - sent after `START_EXTENDED_PRESS` if you keep the button pressed longer; will be sent again every 0,5sec as long as you hold pressed (good for dimming rules) - - `RELEASE_EXTENDED_PRESS` - sent once when you finally release the button after having it pressed longer than 0,5sec +- basic scenario channels are named `scenario` and possible events are: `SCENARIO_01` ... `SCENARIO_16` (or up to `SCENARIO_20` in case of module IR3456) when a scenario is activated +- CEN/CEN+ channels are named `button#X` where `X` is the button number on the CEN/CEN+ Scenario Control device + - in the .thing file configuration you can specify the `buttons` parameter to define a comma-separated list of buttons numbers [0-31] configured for the scenario device, example: `buttons=1,2,4` + - possible events are: + - for CEN: + - `START_PRESS` - sent when you start pressing the button + - `SHORT_PRESS` - sent if you pressed the button shorter than 0,5sec (sent at the moment when you release it) + - `EXTENDED_PRESS` - sent if you keep the button pressed longer than 0,5sec; will be sent again every 0,5sec as long as you hold pressed (good for dimming rules) + - `RELEASE_EXTENDED_PRESS` - sent once when you finally release the button after having it pressed longer than 0,5sec + - for CEN+: + - `SHORT_PRESS` - sent if you pressed the button shorter than 0,5sec (sent at the moment when you release it) + - `START_EXTENDED_PRESS` - sent once as soon as you keep the button pressed longer than 0,5sec + - `EXTENDED_PRESS` - sent after `START_EXTENDED_PRESS` if you keep the button pressed longer; will be sent again every 0,5sec as long as you hold pressed (good for rules involving dimming/volume) + - `RELEASE_EXTENDED_PRESS` - sent once when you finally release the button after having it pressed longer than 0,5sec -#### `mode` for values WEEKLY and SCENARIO (Central Unit) +#### `mode` for values WEEKLY and SCENARIO (thermo Central Unit) -There are three WEEKLY and sixteen SCENARIO programs defined for the Central Unit. +There are three WEEKLY and sixteen SCENARIO programs defined for the thermo Central Unit. In order to activate one of them you have to use two different channels: - with `mode` you can set the mode (`WEEKLY` or `SCENARIO`) -- with `weeklyProgram` (if `WEEKLY` was setted) or with `scenarioProgram` (if `SCENARIO` was setted) you can set the program number +- with `weeklyProgram` (if `WEEKLY` was set) or with `scenarioProgram` (if `SCENARIO` was set) you can set the program number -Example: if you want to activate SCENARIO #9 you have to set `mode` = `SCENARIO` and `scenarioProgram` = `9`. +Example: if you want to activate SCENARIO #9 on the thermo Central Unit you have to set `mode` = `SCENARIO` and `scenarioProgram` = `9`. ## Full Example @@ -297,9 +303,12 @@ Bridge openwebnet:bus_gateway:mybridge "MyHOMEServer1" [ host="192.168.1.35", pa bus_thermo_zone LR_zone "Living Room Zone" [ where="2"] bus_thermo_sensor EXT_tempsensor "External Temperature" [ where="500"] + bus_scenario_control BR_scenario "Bedroom Scenario Module" [ where="95" ] + bus_cen_scenario_control LR_CEN_scenario "Living Room CEN" [ where="51", buttons="4,3,8"] bus_cenplus_scenario_control LR_CENplus_scenario "Living Room CEN+" [ where="212", buttons="1,5,18" ] bus_dry_contact_ir LR_IR_sensor "Living Room IR Sensor" [ where="399" ] + bus_aux Alarm_activation "Alarm activation" [ where="4" ] } ``` @@ -421,6 +430,15 @@ sitemap openwebnet label="OpenWebNet Binding Example Sitemap" ### openwebnet.rules ```xtend +rule "Basic scenario WHO=0" +// A "SCENARIO_02" event started from Scenario device where=95 will switch ON iLR_switch % +when + Channel "openwebnet:bus_scenario_control:mybridge:BR_scenario:scenario" triggered SCENARIO_02 +then + sendCommand(iLR_switch, ON) +end + + rule "CEN+ virtual press from OH button" /* This rule triggers when the proxy item iCENPlusProxyItem is activated, for example from a button on WebUI/sitemap. When activated it sends a "virtual short press" event (where=212, button=5) on the BUS @@ -453,7 +471,7 @@ end ## Notes -- The OpenWebNet protocol is maintained and Copyright by BTicino/Legrand. The documentation of the protocol if freely accessible for developers on the [Legrand developer web site](https://developer.legrand.com/documentation/open-web-net-for-myhome/) +The OpenWebNet protocol is maintained and Copyright by BTicino/Legrand. The documentation of the protocol if freely accessible for developers on the [Legrand developer web site](https://developer.legrand.com/documentation/open-web-net-for-myhome/) ## Special thanks @@ -467,5 +485,6 @@ Special thanks for helping on testing this binding go to: [@llegovich](https://community.openhab.org/u/llegovich), [@gabriele.daltoe](https://community.openhab.org/u/gabriele.daltoe), [@feodor](https://community.openhab.org/u/feodor), -[@aconte80](https://community.openhab.org/u/aconte80) +[@aconte80](https://community.openhab.org/u/aconte80), +[@rubenfuser](https://community.openhab.org/u/rubenfuser) and many others at the fantastic openHAB community! diff --git a/bundles/org.openhab.binding.openwebnet/pom.xml b/bundles/org.openhab.binding.openwebnet/pom.xml index 08bb64bca..d9bf3e359 100644 --- a/bundles/org.openhab.binding.openwebnet/pom.xml +++ b/bundles/org.openhab.binding.openwebnet/pom.xml @@ -23,7 +23,7 @@ io.github.openwebnet4j openwebnet4j - 0.8.1 + 0.9.0 compile diff --git a/bundles/org.openhab.binding.openwebnet/src/main/java/org/openhab/binding/openwebnet/internal/OpenWebNetBindingConstants.java b/bundles/org.openhab.binding.openwebnet/src/main/java/org/openhab/binding/openwebnet/internal/OpenWebNetBindingConstants.java index c51acc140..812f549cb 100644 --- a/bundles/org.openhab.binding.openwebnet/src/main/java/org/openhab/binding/openwebnet/internal/OpenWebNetBindingConstants.java +++ b/bundles/org.openhab.binding.openwebnet/src/main/java/org/openhab/binding/openwebnet/internal/OpenWebNetBindingConstants.java @@ -24,7 +24,7 @@ import org.openhab.core.thing.ThingTypeUID; /** * The {@link OpenWebNetBindingConstants} class defines common constants, which are used across the whole binding. * - * @author Massimo Valla - Initial contribution + * @author Massimo Valla - Initial contribution, updates * @author Gilberto Cocchi - Thermoregulation * @author Andrea Conte - Energy management, Thermoregulation * @author Giovanni Fabiani - Aux support @@ -64,13 +64,14 @@ public class OpenWebNetBindingConstants { public static final String THING_LABEL_BUS_THERMO_CU = "Thermo Central Unit"; public static final ThingTypeUID THING_TYPE_BUS_CEN_SCENARIO_CONTROL = new ThingTypeUID(BINDING_ID, "bus_cen_scenario_control"); - public static final String THING_LABEL_BUS_CEN_SCENARIO_CONTROL = "CEN Control"; + public static final String THING_LABEL_BUS_CEN_SCENARIO_CONTROL = "CEN Scenario Control"; public static final ThingTypeUID THING_TYPE_BUS_DRY_CONTACT_IR = new ThingTypeUID(BINDING_ID, "bus_dry_contact_ir"); public static final String THING_LABEL_BUS_DRY_CONTACT_IR = "Dry Contact/IR"; public static final ThingTypeUID THING_TYPE_BUS_CENPLUS_SCENARIO_CONTROL = new ThingTypeUID(BINDING_ID, "bus_cenplus_scenario_control"); - public static final String THING_LABEL_BUS_CENPLUS_SCENARIO_CONTROL = "CEN+ Control"; - + public static final String THING_LABEL_BUS_CENPLUS_SCENARIO_CONTROL = "CEN+ Scenario Control"; + public static final ThingTypeUID THING_TYPE_BUS_SCENARIO = new ThingTypeUID(BINDING_ID, "bus_scenario_control"); + public static final String THING_LABEL_BUS_SCENARIO = "Scenario Control"; public static final ThingTypeUID THING_TYPE_BUS_AUX = new ThingTypeUID(BINDING_ID, "bus_aux"); public static final String THING_LABEL_BUS_AUX = "Auxiliary"; // ZIGBEE @@ -102,14 +103,16 @@ public class OpenWebNetBindingConstants { // ## CEN/CEN+ Scenario public static final Set SCENARIO_SUPPORTED_THING_TYPES = Set.of(THING_TYPE_BUS_CEN_SCENARIO_CONTROL, THING_TYPE_BUS_CENPLUS_SCENARIO_CONTROL, THING_TYPE_BUS_DRY_CONTACT_IR); - + // ## Basic Scenario + public static final Set SCENARIO_BASIC_SUPPORTED_THING_TYPES = Set.of(THING_TYPE_BUS_SCENARIO); // ## Aux public static final Set AUX_SUPPORTED_THING_TYPES = Set.of(THING_TYPE_BUS_AUX); // ## Groups public static final Set DEVICE_SUPPORTED_THING_TYPES = Stream .of(LIGHTING_SUPPORTED_THING_TYPES, AUTOMATION_SUPPORTED_THING_TYPES, THERMOREGULATION_SUPPORTED_THING_TYPES, ENERGY_MANAGEMENT_SUPPORTED_THING_TYPES, - SCENARIO_SUPPORTED_THING_TYPES, GENERIC_SUPPORTED_THING_TYPES, AUX_SUPPORTED_THING_TYPES) + SCENARIO_SUPPORTED_THING_TYPES, SCENARIO_BASIC_SUPPORTED_THING_TYPES, AUX_SUPPORTED_THING_TYPES, + GENERIC_SUPPORTED_THING_TYPES) .flatMap(Collection::stream).collect(Collectors.toCollection(HashSet::new)); public static final Set BRIDGE_SUPPORTED_THING_TYPES = Set.of(THING_TYPE_ZB_GATEWAY, THING_TYPE_BUS_GATEWAY); @@ -143,7 +146,6 @@ public class OpenWebNetBindingConstants { public static final String CHANNEL_CU_AT_LEAST_ONE_PROBE_OFF = "atLeastOneProbeOff"; public static final String CHANNEL_CU_AT_LEAST_ONE_PROBE_PROTECTION = "atLeastOneProbeProtection"; public static final String CHANNEL_CU_AT_LEAST_ONE_PROBE_MANUAL = "atLeastOneProbeManual"; - // energy management public static final String CHANNEL_POWER = "power"; // scenario button channels @@ -151,8 +153,9 @@ public class OpenWebNetBindingConstants { public static final String CHANNEL_TYPE_CEN_BUTTON_EVENT = "cenButtonEvent"; public static final String CHANNEL_TYPE_CEN_PLUS_BUTTON_EVENT = "cenPlusButtonEvent"; public static final String CHANNEL_DRY_CONTACT_IR = "sensor"; - - // Aux + // basic scenario + public static final String CHANNEL_SCENARIO = "scenario"; + // aux public static final String CHANNEL_AUX = "aux"; // devices config properties diff --git a/bundles/org.openhab.binding.openwebnet/src/main/java/org/openhab/binding/openwebnet/internal/OpenWebNetHandlerFactory.java b/bundles/org.openhab.binding.openwebnet/src/main/java/org/openhab/binding/openwebnet/internal/OpenWebNetHandlerFactory.java index 3f484fb79..4459e9526 100644 --- a/bundles/org.openhab.binding.openwebnet/src/main/java/org/openhab/binding/openwebnet/internal/OpenWebNetHandlerFactory.java +++ b/bundles/org.openhab.binding.openwebnet/src/main/java/org/openhab/binding/openwebnet/internal/OpenWebNetHandlerFactory.java @@ -22,6 +22,7 @@ import org.openhab.binding.openwebnet.internal.handler.OpenWebNetBridgeHandler; import org.openhab.binding.openwebnet.internal.handler.OpenWebNetEnergyHandler; import org.openhab.binding.openwebnet.internal.handler.OpenWebNetGenericHandler; import org.openhab.binding.openwebnet.internal.handler.OpenWebNetLightingHandler; +import org.openhab.binding.openwebnet.internal.handler.OpenWebNetScenarioBasicHandler; import org.openhab.binding.openwebnet.internal.handler.OpenWebNetScenarioHandler; import org.openhab.binding.openwebnet.internal.handler.OpenWebNetThermoregulationHandler; import org.openhab.core.thing.Bridge; @@ -37,7 +38,7 @@ import org.slf4j.LoggerFactory; /** * The {@link OpenWebNetHandlerFactory} is responsible for creating thing handlers. * - * @author Massimo Valla - Initial contribution + * @author Massimo Valla - Initial contribution, updates * @author Andrea Conte - Energy management, Thermoregulation * @author Gilberto Cocchi - Thermoregulation * @author Giovanni Fabiani - Auxiliary support @@ -79,6 +80,9 @@ public class OpenWebNetHandlerFactory extends BaseThingHandlerFactory { } else if (OpenWebNetAuxiliaryHandler.SUPPORTED_THING_TYPES.contains(thing.getThingTypeUID())) { logger.debug("Creating NEW AUXILIARY Handler"); return new OpenWebNetAuxiliaryHandler(thing); + } else if (OpenWebNetScenarioBasicHandler.SUPPORTED_THING_TYPES.contains(thing.getThingTypeUID())) { + logger.debug("Creating NEW BASIC SCENARIO Handler"); + return new OpenWebNetScenarioBasicHandler(thing); } logger.warn("ThingType {} is not supported by this binding", thing.getThingTypeUID()); return null; diff --git a/bundles/org.openhab.binding.openwebnet/src/main/java/org/openhab/binding/openwebnet/internal/discovery/OpenWebNetDeviceDiscoveryService.java b/bundles/org.openhab.binding.openwebnet/src/main/java/org/openhab/binding/openwebnet/internal/discovery/OpenWebNetDeviceDiscoveryService.java index e366671fb..aa3ecbb1e 100644 --- a/bundles/org.openhab.binding.openwebnet/src/main/java/org/openhab/binding/openwebnet/internal/discovery/OpenWebNetDeviceDiscoveryService.java +++ b/bundles/org.openhab.binding.openwebnet/src/main/java/org/openhab/binding/openwebnet/internal/discovery/OpenWebNetDeviceDiscoveryService.java @@ -156,6 +156,12 @@ public class OpenWebNetDeviceDiscoveryService extends AbstractDiscoveryService deviceWho = Who.ENERGY_MANAGEMENT; break; } + case BASIC_SCENARIO: { + thingTypeUID = OpenWebNetBindingConstants.THING_TYPE_BUS_SCENARIO; + thingLabel = OpenWebNetBindingConstants.THING_LABEL_BUS_SCENARIO; + deviceWho = Who.SCENARIO; + break; + } case SCENARIO_CONTROL: { thingTypeUID = OpenWebNetBindingConstants.THING_TYPE_BUS_CEN_SCENARIO_CONTROL; thingLabel = OpenWebNetBindingConstants.THING_LABEL_BUS_CEN_SCENARIO_CONTROL; diff --git a/bundles/org.openhab.binding.openwebnet/src/main/java/org/openhab/binding/openwebnet/internal/handler/OpenWebNetBridgeHandler.java b/bundles/org.openhab.binding.openwebnet/src/main/java/org/openhab/binding/openwebnet/internal/handler/OpenWebNetBridgeHandler.java index f7c58014c..4c59acd26 100644 --- a/bundles/org.openhab.binding.openwebnet/src/main/java/org/openhab/binding/openwebnet/internal/handler/OpenWebNetBridgeHandler.java +++ b/bundles/org.openhab.binding.openwebnet/src/main/java/org/openhab/binding/openwebnet/internal/handler/OpenWebNetBridgeHandler.java @@ -57,6 +57,7 @@ import org.openwebnet4j.message.FrameException; import org.openwebnet4j.message.GatewayMgmt; import org.openwebnet4j.message.Lighting; import org.openwebnet4j.message.OpenMessage; +import org.openwebnet4j.message.Scenario; import org.openwebnet4j.message.Thermoregulation; import org.openwebnet4j.message.What; import org.openwebnet4j.message.Where; @@ -68,9 +69,10 @@ import org.slf4j.LoggerFactory; /** * The {@link OpenWebNetBridgeHandler} is responsible for handling communication with gateways and handling events. * - * @author Massimo Valla - Initial contribution + * @author Massimo Valla - Initial contribution, Lighting, Automation, Scenario * @author Andrea Conte - Energy management, Thermoregulation * @author Gilberto Cocchi - Thermoregulation + * @author Giovanni Fabiani - Aux */ @NonNullByDefault public class OpenWebNetBridgeHandler extends ConfigStatusBridgeHandler implements GatewayListener { @@ -326,7 +328,7 @@ public class OpenWebNetBridgeHandler extends ConfigStatusBridgeHandler implement } // we support these types only if (baseMsg instanceof Lighting || baseMsg instanceof Automation || baseMsg instanceof EnergyManagement - || baseMsg instanceof Thermoregulation || baseMsg instanceof CEN) { + || baseMsg instanceof Thermoregulation || baseMsg instanceof CEN || baseMsg instanceof Scenario) { BaseOpenMessage bmsg = baseMsg; if (baseMsg instanceof Lighting) { What what = baseMsg.getWhat(); @@ -498,7 +500,8 @@ public class OpenWebNetBridgeHandler extends ConfigStatusBridgeHandler implement BaseOpenMessage baseMsg = (BaseOpenMessage) msg; // let's try to get the Thing associated with this message... if (baseMsg instanceof Lighting || baseMsg instanceof Automation || baseMsg instanceof EnergyManagement - || baseMsg instanceof Thermoregulation || baseMsg instanceof CEN || baseMsg instanceof Auxiliary) { + || baseMsg instanceof Thermoregulation || baseMsg instanceof CEN || baseMsg instanceof Auxiliary + || baseMsg instanceof Scenario) { String ownId = ownIdFromMessage(baseMsg); logger.debug("ownIdFromMessage({}) --> {}", baseMsg, ownId); OpenWebNetThingHandler deviceHandler = registeredDevices.get(ownId); diff --git a/bundles/org.openhab.binding.openwebnet/src/main/java/org/openhab/binding/openwebnet/internal/handler/OpenWebNetScenarioBasicHandler.java b/bundles/org.openhab.binding.openwebnet/src/main/java/org/openhab/binding/openwebnet/internal/handler/OpenWebNetScenarioBasicHandler.java new file mode 100644 index 000000000..0bc280f21 --- /dev/null +++ b/bundles/org.openhab.binding.openwebnet/src/main/java/org/openhab/binding/openwebnet/internal/handler/OpenWebNetScenarioBasicHandler.java @@ -0,0 +1,95 @@ +/** + * Copyright (c) 2010-2022 Contributors to the openHAB project + * + * See the NOTICE file(s) distributed with this work for additional + * information. + * + * This program and the accompanying materials are made available under the + * terms of the Eclipse Public License 2.0 which is available at + * http://www.eclipse.org/legal/epl-2.0 + * + * SPDX-License-Identifier: EPL-2.0 + */ +package org.openhab.binding.openwebnet.internal.handler; + +import java.util.Set; + +import org.eclipse.jdt.annotation.NonNullByDefault; +import org.openhab.binding.openwebnet.internal.OpenWebNetBindingConstants; +import org.openhab.core.thing.ChannelUID; +import org.openhab.core.thing.Thing; +import org.openhab.core.thing.ThingStatus; +import org.openhab.core.thing.ThingTypeUID; +import org.openhab.core.types.Command; +import org.openwebnet4j.message.BaseOpenMessage; +import org.openwebnet4j.message.Scenario.WhatScenario; +import org.openwebnet4j.message.Where; +import org.openwebnet4j.message.WhereLightAutom; +import org.openwebnet4j.message.Who; +import org.slf4j.Logger; +import org.slf4j.LoggerFactory; + +/** + * The {@link OpenWebNetScenarioBasicHandler} is responsible for handling Basic Scenario (WHO=0) messages. + * It extends the abstract {@link OpenWebNetThingHandler}. + * + * @author Massimo Valla - Initial contribution + */ +@NonNullByDefault +public class OpenWebNetScenarioBasicHandler extends OpenWebNetThingHandler { + + private final Logger logger = LoggerFactory.getLogger(OpenWebNetScenarioBasicHandler.class); + + public static final Set SUPPORTED_THING_TYPES = OpenWebNetBindingConstants.SCENARIO_BASIC_SUPPORTED_THING_TYPES; + + public OpenWebNetScenarioBasicHandler(Thing thing) { + super(thing); + logger.debug("created Basic Scenario device for thing: {}", getThing().getUID()); + } + + @Override + protected String ownIdPrefix() { + return Who.SCENARIO.value().toString(); + } + + @Override + protected void handleMessage(BaseOpenMessage msg) { + super.handleMessage(msg); + if (msg.isCommand()) { + WhatScenario scenario = (WhatScenario) msg.getWhat(); + if (scenario == null) { + logger.warn("Invalid Basic Scenario: {}. Ignoring message {}", scenario, msg); + return; + } + logger.debug("Basic Scenario {} has been activated", scenario); + triggerChannel(OpenWebNetBindingConstants.CHANNEL_SCENARIO, scenario.toString()); + } else { + logger.debug("handleMessage() Ignoring unsupported DIM for thing {}. Frame={}", getThing().getUID(), msg); + } + } + + @Override + protected void handleChannelCommand(ChannelUID channel, Command command) { + logger.debug("Basic Scenario are read-only channels. Ignoring command {} for channel {}", command, channel); + } + + @Override + protected void requestChannelState(ChannelUID channel) { + logger.debug("requestChannelState() Basic Scenario channels are trigger channels and do not have state."); + } + + @Override + protected void refreshDevice(boolean refreshAll) { + logger.debug("Basic Scenario channels are trigger channels and do not have state. Setting it ONLINE"); + // put basic scenario things to ONLINE automatically as they do not have state + ThingStatus ts = getThing().getStatus(); + if (ThingStatus.ONLINE != ts && ThingStatus.REMOVING != ts && ThingStatus.REMOVED != ts) { + updateStatus(ThingStatus.ONLINE); + } + } + + @Override + protected Where buildBusWhere(String wStr) throws IllegalArgumentException { + return new WhereLightAutom(wStr); + } +} diff --git a/bundles/org.openhab.binding.openwebnet/src/main/java/org/openhab/binding/openwebnet/internal/handler/OpenWebNetThingHandler.java b/bundles/org.openhab.binding.openwebnet/src/main/java/org/openhab/binding/openwebnet/internal/handler/OpenWebNetThingHandler.java index eac769297..8690fe0ce 100644 --- a/bundles/org.openhab.binding.openwebnet/src/main/java/org/openhab/binding/openwebnet/internal/handler/OpenWebNetThingHandler.java +++ b/bundles/org.openhab.binding.openwebnet/src/main/java/org/openhab/binding/openwebnet/internal/handler/OpenWebNetThingHandler.java @@ -12,9 +12,7 @@ */ package org.openhab.binding.openwebnet.internal.handler; -import static org.openhab.binding.openwebnet.internal.OpenWebNetBindingConstants.CONFIG_PROPERTY_WHERE; -import static org.openhab.binding.openwebnet.internal.OpenWebNetBindingConstants.PROPERTY_OWNID; -import static org.openhab.binding.openwebnet.internal.OpenWebNetBindingConstants.THING_STATE_REQ_TIMEOUT_SEC; +import static org.openhab.binding.openwebnet.internal.OpenWebNetBindingConstants.*; import java.util.Map; import java.util.concurrent.ScheduledFuture; @@ -265,7 +263,8 @@ public abstract class OpenWebNetThingHandler extends BaseThingHandler { logger.debug("--- refreshAllDevices() : refreshing ALL devices... ({})", thing.getUID()); refreshDevice(true); } else { - logger.debug("--- refreshAllDevices() : refresh all devices just sent... ({})", thing.getUID()); + logger.debug("--- refreshAllDevices() : refresh all devices sent {}msec ago, skipping... ({})", + ALL_DEVICES_REFRESH_INTERVAL_MSEC, thing.getUID()); } // sometimes GENERAL (e.g. #*1*0##) refresh requests do not return state for all devices, so let's // schedule another single refresh device, just in case diff --git a/bundles/org.openhab.binding.openwebnet/src/main/resources/OH-INF/i18n/openwebnet.properties b/bundles/org.openhab.binding.openwebnet/src/main/resources/OH-INF/i18n/openwebnet.properties index 3687fec98..87db66dbe 100644 --- a/bundles/org.openhab.binding.openwebnet/src/main/resources/OH-INF/i18n/openwebnet.properties +++ b/bundles/org.openhab.binding.openwebnet/src/main/resources/OH-INF/i18n/openwebnet.properties @@ -23,6 +23,8 @@ thing-type.openwebnet.bus_gateway.label = BUS Gateway thing-type.openwebnet.bus_gateway.description = This thing allows to connect to a IP BUS/SCS gateway that supports the OpenWebNet protocol (models: F454, MyHOMEServer1, F455, MH200N, F453, etc.) thing-type.openwebnet.bus_on_off_switch.label = Switch thing-type.openwebnet.bus_on_off_switch.description = A OpenWebNet BUS/SCS switch for the control of 1 light/load. BTicino models: xxx/yyyy/etc. +thing-type.openwebnet.bus_scenario_control.label = Scenario Control +thing-type.openwebnet.bus_scenario_control.description = A OpenWebNet BUS/SCS Scenario Control device. BTicino models: F420/IR3456 thing-type.openwebnet.bus_thermo_cu.label = Thermo Central Unit thing-type.openwebnet.bus_thermo_cu.description = A OpenWebNet BUS/SCS configured thermo Central Unit. thing-type.openwebnet.bus_thermo_sensor.label = Thermo Sensor @@ -74,6 +76,8 @@ thing-type.config.openwebnet.bus_gateway.port.label = Port thing-type.config.openwebnet.bus_gateway.port.description = OpenWebNet gateway port (default: 20000) thing-type.config.openwebnet.bus_on_off_switch.where.label = OpenWebNet Address (where) thing-type.config.openwebnet.bus_on_off_switch.where.description = Example: A/PL address: A=1 PL=3 --> where=13. On local bus: where=13#4#01 +thing-type.config.openwebnet.bus_scenario_control.where.label = OpenWebNet Address (where) +thing-type.config.openwebnet.bus_scenario_control.where.description = Example: scenario control module address 53 --> where=53. On local bus: where=53#4#01 thing-type.config.openwebnet.bus_thermo_cu.where.label = OpenWebNet Address (where) thing-type.config.openwebnet.bus_thermo_cu.where.description = The Central Unit can only assume where=0. thing-type.config.openwebnet.bus_thermo_sensor.where.label = OpenWebNet Address (where) @@ -137,9 +141,23 @@ channel-type.openwebnet.batteryStatus.description = Central Unit Battery status channel-type.openwebnet.batteryStatus.state.option.OK = OK channel-type.openwebnet.batteryStatus.state.option.KO = KO channel-type.openwebnet.brightness.label = Brightness -channel-type.openwebnet.brightness.description = Control the brightness and switch the light ON and OFF +channel-type.openwebnet.brightness.description = Control the brightness and switch the light ON and OFF (read/write) channel-type.openwebnet.cenButtonEvent.label = CEN Button Event +channel-type.openwebnet.cenButtonEvent.description = Event corresponding to the button press (read only) + +# channel-type.openwebnet.cenButtonEvent.event.option.START_PRESS = Start press +# channel-type.openwebnet.cenButtonEvent.event.option.SHORT_PRESS = Release after short press +# channel-type.openwebnet.cenButtonEvent.event.option.EXTENDED_PRESS = Extended press (repeated until release) +# channel-type.openwebnet.cenButtonEvent.event.option.RELEASE_EXTENDED_PRESS = Release after extended press + channel-type.openwebnet.cenPlusButtonEvent.label = CEN+ Button Event +channel-type.openwebnet.cenPlusButtonEvent.description = Event corresponding to the button press (read only) + +# channel-type.openwebnet.cenPlusButtonEvent.event.option.SHORT_PRESS = Short press +# channel-type.openwebnet.cenPlusButtonEvent.event.option.START_EXTENDED_PRESS = Start of extended press +# channel-type.openwebnet.cenPlusButtonEvent.event.option.EXTENDED_PRESS = Extended press (repeated until release) +# channel-type.openwebnet.cenPlusButtonEvent.event.option.RELEASE_EXTENDED_PRESS = Release after extended press + channel-type.openwebnet.conditioningValves.label = Conditioning Valves channel-type.openwebnet.conditioningValves.description = Conditioning Valves status (read only) channel-type.openwebnet.conditioningValves.state.option.OFF = OFF @@ -164,7 +182,7 @@ channel-type.openwebnet.function.state.option.HEATING = Heating channel-type.openwebnet.function.state.option.COOLING = Cooling channel-type.openwebnet.function.state.option.GENERIC = Generic channel-type.openwebnet.functionCentralUnit.label = Thermo Function -channel-type.openwebnet.functionCentralUnit.description = Thermo function of the Central Unit +channel-type.openwebnet.functionCentralUnit.description = Thermo function of the Central Unit (read only) channel-type.openwebnet.functionCentralUnit.state.option.HEATING = Heating channel-type.openwebnet.functionCentralUnit.state.option.COOLING = Cooling channel-type.openwebnet.heatingValves.label = Heating Valves @@ -210,6 +228,30 @@ channel-type.openwebnet.remoteControl.label = Remote Control channel-type.openwebnet.remoteControl.description = Central Unit Remote Control status (read only) channel-type.openwebnet.remoteControl.state.option.DISABLED = DISABLED channel-type.openwebnet.remoteControl.state.option.ENABLED = ENABLED +channel-type.openwebnet.scenarioEvent.label = Activated Scenario Event +channel-type.openwebnet.scenarioEvent.description = Event corresponding to the number of Basic Scenario that has been activated (read only) + +# channel-type.openwebnet.scenarioEvent.event.option.SCENARIO_01 = Scenario 1 +# channel-type.openwebnet.scenarioEvent.event.option.SCENARIO_02 = Scenario 2 +# channel-type.openwebnet.scenarioEvent.event.option.SCENARIO_03 = Scenario 3 +# channel-type.openwebnet.scenarioEvent.event.option.SCENARIO_04 = Scenario 4 +# channel-type.openwebnet.scenarioEvent.event.option.SCENARIO_05 = Scenario 5 +# channel-type.openwebnet.scenarioEvent.event.option.SCENARIO_06 = Scenario 6 +# channel-type.openwebnet.scenarioEvent.event.option.SCENARIO_07 = Scenario 7 +# channel-type.openwebnet.scenarioEvent.event.option.SCENARIO_08 = Scenario 8 +# channel-type.openwebnet.scenarioEvent.event.option.SCENARIO_09 = Scenario 9 +# channel-type.openwebnet.scenarioEvent.event.option.SCENARIO_10 = Scenario 10 +# channel-type.openwebnet.scenarioEvent.event.option.SCENARIO_11 = Scenario 11 +# channel-type.openwebnet.scenarioEvent.event.option.SCENARIO_12 = Scenario 12 +# channel-type.openwebnet.scenarioEvent.event.option.SCENARIO_13 = Scenario 13 +# channel-type.openwebnet.scenarioEvent.event.option.SCENARIO_14 = Scenario 14 +# channel-type.openwebnet.scenarioEvent.event.option.SCENARIO_15 = Scenario 15 +# channel-type.openwebnet.scenarioEvent.event.option.SCENARIO_16 = Scenario 16 +# channel-type.openwebnet.scenarioEvent.event.option.SCENARIO_17 = Scenario 17 +# channel-type.openwebnet.scenarioEvent.event.option.SCENARIO_18 = Scenario 18 +# channel-type.openwebnet.scenarioEvent.event.option.SCENARIO_19 = Scenario 19 +# channel-type.openwebnet.scenarioEvent.event.option.SCENARIO_20 = Scenario 20 + channel-type.openwebnet.scenarioProgramCentralUnit.label = Scenario Program Number channel-type.openwebnet.scenarioProgramCentralUnit.description = Set scenario program number for the Central Unit, valid only with Central Unit mode = "SCENARIO" (read/write) channel-type.openwebnet.scenarioProgramCentralUnit.state.option.1 = Program 1 @@ -231,7 +273,7 @@ channel-type.openwebnet.scenarioProgramCentralUnit.state.option.16 = Program 16 channel-type.openwebnet.setpointTemperature.label = Setpoint Temperature channel-type.openwebnet.setpointTemperature.description = Setpoint temperature (read/write) channel-type.openwebnet.shutter.label = Roller Shutter -channel-type.openwebnet.shutter.description = Control the roller shutter position +channel-type.openwebnet.shutter.description = Control the roller shutter position (read/write) channel-type.openwebnet.speedFanCoil.label = Set Fan Speed channel-type.openwebnet.speedFanCoil.description = Set speed of the Fan Coil (read/write) channel-type.openwebnet.speedFanCoil.state.option.AUTO = Auto diff --git a/bundles/org.openhab.binding.openwebnet/src/main/resources/OH-INF/thing/BusBasicScenarioControl.xml b/bundles/org.openhab.binding.openwebnet/src/main/resources/OH-INF/thing/BusBasicScenarioControl.xml new file mode 100644 index 000000000..215e25402 --- /dev/null +++ b/bundles/org.openhab.binding.openwebnet/src/main/resources/OH-INF/thing/BusBasicScenarioControl.xml @@ -0,0 +1,36 @@ + + + + + + + + + + + + A OpenWebNet BUS/SCS Scenario Control device. BTicino models: F420/IR3456 + + + + + + + BTicino/Legrand + BTI-F420/IR3456 + 3 + + + ownId + + + + + Example: scenario control module address 53 --> where=53. On local bus: where=53#4#01 + + + + + diff --git a/bundles/org.openhab.binding.openwebnet/src/main/resources/OH-INF/thing/channels.xml b/bundles/org.openhab.binding.openwebnet/src/main/resources/OH-INF/thing/channels.xml index 698a7cc0d..aa5747664 100644 --- a/bundles/org.openhab.binding.openwebnet/src/main/resources/OH-INF/thing/channels.xml +++ b/bundles/org.openhab.binding.openwebnet/src/main/resources/OH-INF/thing/channels.xml @@ -43,7 +43,7 @@ Dimmer - Control the brightness and switch the light ON and OFF + Control the brightness and switch the light ON and OFF (read/write) Light Control @@ -55,7 +55,7 @@ Rollershutter - Control the roller shutter position + Control the roller shutter position (read/write) Blinds OpenLevel @@ -92,7 +92,7 @@ String - Thermo function of the Central Unit + Thermo function of the Central Unit (read only) @@ -341,16 +341,48 @@ + + + trigger + + Event corresponding to the number of Basic Scenario that has been activated (read only) + + + + + + + + + + + + + + + + + + + + + + + + + + trigger + Event corresponding to the button press (read only) - - - - + + + + @@ -358,16 +390,18 @@ trigger + Event corresponding to the button press (read only) - - - - + + + + + Switch diff --git a/bundles/org.openhab.binding.openwebnet/src/test/java/org/openhab/binding/openwebnet/internal/handler/OwnIdTest.java b/bundles/org.openhab.binding.openwebnet/src/test/java/org/openhab/binding/openwebnet/internal/handler/OwnIdTest.java index 87f02831e..9b942e5a2 100644 --- a/bundles/org.openhab.binding.openwebnet/src/test/java/org/openhab/binding/openwebnet/internal/handler/OwnIdTest.java +++ b/bundles/org.openhab.binding.openwebnet/src/test/java/org/openhab/binding/openwebnet/internal/handler/OwnIdTest.java @@ -39,7 +39,7 @@ import org.slf4j.LoggerFactory; * * @author Massimo Valla - Initial contribution * @author Andrea Conte - Energy management - * @author Giovanni Fabiani - AAuxiliary message support + * @author Giovanni Fabiani - Auxiliary message support */ @NonNullByDefault public class OwnIdTest { @@ -66,7 +66,8 @@ public class OwnIdTest { * BUS CEN 51 51 15.51 51 * BUS CEN+ 212 212 25.212 212 * BUS DryContact 399 399 25.399 399 - * BUS AUX 4 4 9.4 4 + * BUS AUX 4 4 9.4 4 + * BUS Scenario 05 05 0.05 05 */ // @formatter:on @@ -86,7 +87,9 @@ public class OwnIdTest { bus_cen(new WhereCEN("51"), Who.fromValue(15), "*15*31*51##", "51", "15.51", "51"), bus_cen_plus(new WhereCEN("212"), Who.fromValue(25), "*25*21#31*212##", "212", "25.212", "212"), bus_drycontact(new WhereCEN("399"), Who.fromValue(25), "*25*32#1*399##", "399", "25.399", "399"), - bus_aux(new WhereAuxiliary("4"), Who.fromValue(9), "*9*1*4##","4","9.4","4"); + bus_aux(new WhereAuxiliary("4"), Who.fromValue(9), "*9*1*4##","4","9.4","4"), + bus_scenario(new WhereLightAutom("05"), Who.fromValue(0), "*0*2*05##","05","0.05","05"); + // @formatter:on