[openwebnet] add support for Thermoregulation (standalone thermostat and sensors) (#10756)
Signed-off-by: Conte Andrea <andrea@conte.com> Signed-off-by: Massimo Valla <mvcode00@gmail.com> Co-authored-by: Massimo Valla <mvcode00@gmail.com>
This commit is contained in:
@@ -37,20 +37,21 @@ The following Things and OpenWebNet `WHOs` are supported:
|
||||
|
||||
### For BUS/SCS
|
||||
|
||||
| Category | WHO | Thing Type IDs | Description | Status |
|
||||
| -------------------- | :----------: | :------------------------------------------: | -------------------------------------------------------------- | ---------------- |
|
||||
| Gateway Management | `13` | `bus_gateway` | Any IP gateway supporting OpenWebNet protocol should work (e.g. F454 / MyHOMEServer1 / MH202 / F455 / MH200N, ...) | Successfully tested: F454, MyHOMEServer1, MyHOME_Screen10, F455, F452, F453AV, MH201, MH202, MH200N. Some connection stability issues/gateway resets reported with MH202 |
|
||||
| Lighting | `1` | `bus_on_off_switch`, `bus_dimmer` | BUS switches and dimmers | Successfully tested: F411/2, F411/4, F411U2, F422, F429. Some discovery issues reported with F429 (DALI Dimmers) |
|
||||
| Automation | `2` | `bus_automation` | BUS roller shutters, with position feedback and auto-calibration | Successfully tested: LN4672M2 |
|
||||
| Energy Management | `18` | `bus_energy_meter` | Energy Management | Successfully tested: F520, F521 |
|
||||
| Category | WHO | Thing Type IDs | Description | Status |
|
||||
| -------------------- | :----------: | :---------------------------------: | ---------------------------------------------------------------- | ---------------- |
|
||||
| Gateway Management | `13` | `bus_gateway` | Any IP gateway supporting OpenWebNet protocol should work (e.g. F454 / MyHOMEServer1 / MH202 / F455 / MH200N, ...) | Successfully tested: F454, MyHOMEServer1, MyHOME_Screen10, F455, F452, F453AV, MH201, MH202, MH200N. Some connection stability issues/gateway resets reported with MH202 |
|
||||
| Lighting | `1` | `bus_on_off_switch`, `bus_dimmer` | BUS switches and dimmers | Successfully tested: F411/2, F411/4, F411U2, F422, F429. Some discovery issues reported with F429 (DALI Dimmers) |
|
||||
| Automation | `2` | `bus_automation` | BUS roller shutters, with position feedback and auto-calibration | Successfully tested: LN4672M2 |
|
||||
| Temperature Control | `4` | `bus_thermostat`, `bus_temp_sensor` | Zones room thermostats (stand-alone) and external wireless temperature sensors. Please note that Central Unit configurations (4 or 99 zones) are not yet supported. See [Channels - Thermo](#thermo-channels) for more details. | Successfully tested: H/LN4691; external sensors: L/N/NT4577 + 3455 |
|
||||
| Energy Management | `18` | `bus_energy_meter` | Energy Management | Successfully tested: F520, F521 |
|
||||
|
||||
### For ZigBee (Radio)
|
||||
|
||||
| Category | WHO | Thing Type IDs | Description | Status |
|
||||
| -------------------- | :----: | :-------------------------------: | :-------------------------------------------------------------------: | ------------------------------------ |
|
||||
| Gateway Management | `13` | `zb_gateway` | ZigBee USB Gateway (models: BTI-3578 / LG 088328) | Tested: BTI-3578 and LG 088328 |
|
||||
| Lighting | `1` | `zb_dimmer`, `zb_on_off_switch`, `zb_on_off_switch2u` | ZigBee dimmers, switches and 2-unit switches | Tested: BTI-4591, BTI-3584, BTI-4585 |
|
||||
| Automation | `2` | `zb_automation` | ZigBee roller shutters | |
|
||||
| Gateway Management | `13` | `zb_gateway` | ZigBee USB Gateway (models: BTI-3578 / LG 088328) | Tested: BTI-3578 and LG 088328 |
|
||||
| Lighting | `1` | `zb_dimmer`, `zb_on_off_switch`, `zb_on_off_switch2u` | ZigBee dimmers, switches and 2-unit switches | Tested: BTI-4591, BTI-3584, BTI-4585 |
|
||||
| Automation | `2` | `zb_automation` | ZigBee roller shutters | |
|
||||
|
||||
## Discovery
|
||||
|
||||
@@ -121,18 +122,36 @@ For any manually added device, you must configure:
|
||||
- the `where` config parameter (`OpenWebNet Device Address`):
|
||||
- example for BUS/SCS device with WHERE address Point to Point `A=2 PL=4` --> `where="24"`
|
||||
- example for BUS/SCS device with WHERE address Point to Point `A=03 PL=11` on local bus --> `where="0311#4#01"`
|
||||
- example for BUS/SCS thermo Zones: `Zone=1` --> `where="1"`; external sensor `5` --> `where="500"`
|
||||
- example for ZigBee devices: `where=765432101#9`. The ID of the device (ADDR part) is usually written in hexadecimal on the device itself, for example `ID 0074CBB1`: convert to decimal (`7654321`) and add `01#9` at the end to obtain `where=765432101#9`. For 2-unit switch devices (`zb_on_off_switch2u`), last part should be `00#9`.
|
||||
|
||||
## Channels
|
||||
## Channels
|
||||
|
||||
### Lighting, Automation and Power meter channels
|
||||
|
||||
| Channel Type ID (channel ID) | Applies to Thing Type IDs | Item Type | Description | Read/Write |
|
||||
| ---------------------------------------- | ------------------------------------------------------------- | ------------- | ----------------------------------------------------- | :--------: |
|
||||
| `switch` or `switch_01`/`02` for ZigBee | `bus_on_off_switch`, `zb_on_off_switch`, `zb_on_off_switch2u` | Switch | To switch the device `ON` and `OFF` | R/W |
|
||||
| `brightness` | `bus_dimmer`, `zb_dimmer` | Dimmer | To adjust the brightness value (Percent, `ON`, `OFF`) | R/W |
|
||||
| `shutter` | `bus_automation` | Rollershutter | To activate roller shutters (`UP`, `DOWN`, `STOP`, Percent - [see Shutter position](#shutter-position)) | R/W |
|
||||
| `power` | `bus_energy_meter` | Number:Power | The current active power usage from Energy Meter | R |
|
||||
|
||||
### Thermo channels
|
||||
|
||||
Currently only stand-alone thermostats are supported (like [LN4691](https://catalogo.bticino.it/BTI-LN4691-IT)) and the specific thing `bus_thermostat` was created to manage them.
|
||||
|
||||
| Channel Type ID (channel ID) | Applies to Thing Type IDs | Item Type | Description | Read/Write | Advanced |
|
||||
| ---------------------------- | ----------------------------------- | ------------------ | ------------------------------------------------- | :--------: | :------: |
|
||||
| `temperature` | `bus_thermostat`, `bus_temp_sensor` | Number:Temperature | The zone currently sensed temperature | R | N |
|
||||
| `setpointTemperature` | `bus_thermostat` | Number:Temperature | The zone setpoint temperature | R/W | N |
|
||||
| `function` | `bus_thermostat` | String | The zone set thermo function: `COOLING`, `HEATING` or `GENERIC` (heating + cooling) | R/W | N |
|
||||
| `mode` | `bus_thermostat` | String | The zone set mode: `MANUAL`, `PROTECTION`, `OFF` | R/W | N |
|
||||
| `speedFanCoil` | `bus_thermostat` | String | The zone fancoil speed: `AUTO`, `SPEED_1`, `SPEED_2`, `SPEED_3` | R/W | N |
|
||||
| `actuator` | `bus_thermostat` | String | The zone actuator(s) status: `OFF`, `ON`, `OPENED`, `CLOSED` , `STOP`, `OFF_FAN_COIL`, `ON_SPEED_1`, `ON_SPEED_2`, `ON_SPEED_3`, `OFF_SPEED_1`, `OFF_SPEED_2`, `OFF_SPEED_3` | R | Y |
|
||||
| `heatingValve` | `bus_thermostat` | String | The zone heating valve(s) status: `OFF`, `ON`, `OPENED`, `CLOSED` , `STOP`, `OFF_FAN_COIL`, `ON_SPEED_1`, `ON_SPEED_2`, `ON_SPEED_3`, `OFF_SPEED_1`, `OFF_SPEED_2`, `OFF_SPEED_3` | R | Y |
|
||||
| `conditioningValve` | `bus_thermostat` | String | The zone conditioning valve(s) status: `OFF`, `ON`, `OPENED`, `CLOSED` , `STOP`, `OFF_FAN_COIL`, `ON_SPEED_1`, `ON_SPEED_2`, `ON_SPEED_3`, `OFF_SPEED_1`, `OFF_SPEED_2`, `OFF_SPEED_3` | R | Y |
|
||||
|
||||
Devices support some of the following channels:
|
||||
|
||||
| Channel Type ID (channel ID) | Item Type | Description | Read/Write |
|
||||
|------------------------------------------------|---------------|---------------------------------------------------------|:----------:|
|
||||
| `switch` or `switch_01`/`02` for ZigBee | Switch | To switch the device `ON` and `OFF` | R/W |
|
||||
| `brightness` | Dimmer | To adjust the brightness value (Percent, `ON`, `OFF`) | R/W |
|
||||
| `shutter` | Rollershutter | To activate roller shutters (`UP`, `DOWN`, `STOP`, Percent - [see Shutter position](#shutter-position)) | R/W |
|
||||
| `power` | Number:Power | The current active power usage from Energy Meter | R |
|
||||
### Notes on channels
|
||||
|
||||
#### `shutter` position
|
||||
@@ -154,11 +173,13 @@ BUS gateway and things configuration:
|
||||
|
||||
```xtend
|
||||
Bridge openwebnet:bus_gateway:mybridge "MyHOMEServer1" [ host="192.168.1.35", passwd="abcde", port=20000, discoveryByActivation=false ] {
|
||||
bus_on_off_switch LR_switch "Living Room Light" [ where="51" ]
|
||||
bus_dimmer LR_dimmer "Living Room Dimmer" [ where="0311#4#01" ]
|
||||
bus_automation LR_shutter "Living Room Shutter" [ where="93", shutterRun="10050"]
|
||||
bus_energy_meter CENTRAL_Ta "Energy Meter Ta" [ where="51" ]
|
||||
bus_energy_meter CENTRAL_Tb "Energy Meter Tb" [ where="52" ]
|
||||
bus_on_off_switch LR_switch "Living Room Light" [ where="51" ]
|
||||
bus_dimmer LR_dimmer "Living Room Dimmer" [ where="0311#4#01" ]
|
||||
bus_automation LR_shutter "Living Room Shutter" [ where="93", shutterRun="10050"]
|
||||
bus_energy_meter CENTRAL_Ta "Energy Meter Ta" [ where="51" ]
|
||||
bus_energy_meter CENTRAL_Tb "Energy Meter Tb" [ where="52" ]
|
||||
bus_thermostat LR_thermostat "Living Room Thermostat" [ where="2"]
|
||||
bus_temp_sensor EXT_tempsensor "External Temperature" [ where="500"]
|
||||
}
|
||||
```
|
||||
|
||||
@@ -178,11 +199,18 @@ Bridge openwebnet:zb_gateway:myZBgateway [ serialPort="COM3" ] {
|
||||
Example items linked to BUS devices:
|
||||
|
||||
```xtend
|
||||
Switch iLR_switch "Light" <light> (gLivingRoom) [ "Lighting" ] { channel="openwebnet:bus_on_off_switch:mybridge:LR_switch:switch" }
|
||||
Dimmer iLR_dimmer "Dimmer [%.0f %%]" <DimmableLight> (gLivingRoom) [ "Lighting" ] { channel="openwebnet:bus_dimmer:mybridge:LR_dimmer:brightness" }
|
||||
Rollershutter iLR_shutter "Shutter [%.0f %%]" <rollershutter> (gShutters, gLivingRoom) [ "Blinds" ] { channel="openwebnet:bus_automation:mybridge:LR_shutter:shutter" }
|
||||
Number:Power iCENTRAL_Ta "Power [%.0f %unit%]" <energy> { channel="openwebnet:bus_energy_meter:mybridge:CENTRAL_Ta:power" }
|
||||
Number:Power iCENTRAL_Tb "Power [%.0f %unit%]" <energy> { channel="openwebnet:bus_energy_meter:mybridge:CENTRAL_Tb:power" }
|
||||
Switch iLR_switch "Light" <light> (gLivingRoom) [ "Lighting" ] { channel="openwebnet:bus_on_off_switch:mybridge:LR_switch:switch" }
|
||||
Dimmer iLR_dimmer "Dimmer [%.0f %%]" <DimmableLight> (gLivingRoom) [ "Lighting" ] { channel="openwebnet:bus_dimmer:mybridge:LR_dimmer:brightness" }
|
||||
Rollershutter iLR_shutter "Shutter [%.0f %%]" <rollershutter> (gShutters, gLivingRoom) [ "Blinds" ] { channel="openwebnet:bus_automation:mybridge:LR_shutter:shutter" }
|
||||
Number:Power iCENTRAL_Ta "Power [%.0f %unit%]" <energy> { channel="openwebnet:bus_energy_meter:mybridge:CENTRAL_Ta:power" }
|
||||
Number:Power iCENTRAL_Tb "Power [%.0f %unit%]" <energy> { channel="openwebnet:bus_energy_meter:mybridge:CENTRAL_Tb:power" }
|
||||
Number:Temperature iLR_thermostat_temp "Temperature" (gLivingRoom) { channel="openwebnet:bus_thermostat:mybridge:LR_thermostat:temperature" }
|
||||
Number:Temperature iLR_thermostat_set "SetPoint Temperature" (gLivingRoom) { channel="openwebnet:bus_thermostat:mybridge:LR_thermostat:setpointTemperature" }
|
||||
String iLR_thermostat_setFanSpeed "FanSpeed" (gLivingRoom) { channel="openwebnet:bus_thermostat:mybridge:LR_thermostat:speedFanCoil" }
|
||||
String iLR_thermostat_setMode "Mode" (gLivingRoom) { channel="openwebnet:bus_thermostat:mybridge:LR_thermostat:mode" }
|
||||
String iLR_thermostat_setFunc "Function" (gLivingRoom) { channel="openwebnet:bus_thermostat:mybridge:LR_thermostat:function" }
|
||||
Number:Temperature iEXT_temp "Temperature [%.1f °C]" <temperature> (gExternal) { channel="openwebnet:bus_temp_sensor:mybridge:EXT_tempsensor:temperature" }
|
||||
|
||||
|
||||
```
|
||||
|
||||
@@ -212,6 +240,15 @@ sitemap openwebnet label="OpenWebNet Binding Example Sitemap"
|
||||
Default item=iCENTRAL_Ta label="General" icon="energy" valuecolor=[>3000="red"]
|
||||
Default item=iCENTRAL_Tb label="Ground Floor" icon="energy" valuecolor=[>3000="red"]
|
||||
}
|
||||
|
||||
Frame label="Thermoregulation"
|
||||
{
|
||||
Default item=iLR_thermostat_temp label="Temperature" icon="fire" valuecolor=[<20="red"]
|
||||
Setpoint item=iLR_thermostat_set label="Setpoint [%.1f °C]" step=0.5 minValue=15 maxValue=30
|
||||
Selection item=iLR_thermostat_setFanSpeed label="Fan Speed" icon="fan" mappings=[AUTO="AUTO", SPEED_1="Low", SPEED_2="Medium", SPEED_3="High"]
|
||||
Switch item=iLR_thermostat_setMode label="Mode" icon="settings"
|
||||
Selection item=iLR_thermostat_setFunc label="Function" icon="heating" mappings=[HEATING="Heating", COOLING="Cooling", GENERIC="Heating/Cooling"]
|
||||
}
|
||||
}
|
||||
```
|
||||
|
||||
|
||||