[openwebnet] add support for Thermoregulation (standalone thermostat and sensors) (#10756)
Signed-off-by: Conte Andrea <andrea@conte.com> Signed-off-by: Massimo Valla <mvcode00@gmail.com> Co-authored-by: Massimo Valla <mvcode00@gmail.com>
This commit is contained in:
@@ -12,7 +12,6 @@
|
||||
*/
|
||||
package org.openhab.binding.openwebnet;
|
||||
|
||||
import java.util.Arrays;
|
||||
import java.util.Collection;
|
||||
import java.util.HashSet;
|
||||
import java.util.Set;
|
||||
@@ -26,7 +25,8 @@ import org.openhab.core.thing.ThingTypeUID;
|
||||
* The {@link OpenWebNetBindingConstants} class defines common constants, which are used across the whole binding.
|
||||
*
|
||||
* @author Massimo Valla - Initial contribution
|
||||
* @author Andrea Conte - Energy management
|
||||
* @author Andrea Conte - Energy management, Thermoregulation
|
||||
* @author Gilberto Cocchi - Thermoregulation
|
||||
*/
|
||||
|
||||
@NonNullByDefault
|
||||
@@ -55,6 +55,10 @@ public class OpenWebNetBindingConstants {
|
||||
public static final String THING_LABEL_BUS_AUTOMATION = "Automation";
|
||||
public static final ThingTypeUID THING_TYPE_BUS_ENERGY_METER = new ThingTypeUID(BINDING_ID, "bus_energy_meter");
|
||||
public static final String THING_LABEL_BUS_ENERGY_METER = "Energy Meter";
|
||||
public static final ThingTypeUID THING_TYPE_BUS_TEMP_SENSOR = new ThingTypeUID(BINDING_ID, "bus_temp_sensor");
|
||||
public static final String THING_LABEL_BUS_TEMP_SENSOR = "Temperature Sensor";
|
||||
public static final ThingTypeUID THING_TYPE_BUS_THERMOSTAT = new ThingTypeUID(BINDING_ID, "bus_thermostat");
|
||||
public static final String THING_LABEL_BUS_THERMOSTAT = "Thermostat (stand-alone)";
|
||||
|
||||
// ZIGBEE
|
||||
public static final ThingTypeUID THING_TYPE_ZB_ON_OFF_SWITCH = new ThingTypeUID(BINDING_ID, "zb_on_off_switch");
|
||||
@@ -69,28 +73,31 @@ public class OpenWebNetBindingConstants {
|
||||
|
||||
// #SUPPORTED THINGS SETS
|
||||
// ## Generic
|
||||
public static final Set<ThingTypeUID> GENERIC_SUPPORTED_THING_TYPES = new HashSet<>(
|
||||
Arrays.asList(THING_TYPE_GENERIC_DEVICE));
|
||||
public static final Set<ThingTypeUID> GENERIC_SUPPORTED_THING_TYPES = Set.of(THING_TYPE_GENERIC_DEVICE);
|
||||
// ## Lighting
|
||||
public static final Set<ThingTypeUID> LIGHTING_SUPPORTED_THING_TYPES = new HashSet<>(
|
||||
Arrays.asList(THING_TYPE_ZB_ON_OFF_SWITCH, THING_TYPE_ZB_ON_OFF_SWITCH_2UNITS, THING_TYPE_ZB_DIMMER,
|
||||
THING_TYPE_BUS_ON_OFF_SWITCH, THING_TYPE_BUS_DIMMER));
|
||||
public static final Set<ThingTypeUID> LIGHTING_SUPPORTED_THING_TYPES = Set.of(THING_TYPE_ZB_ON_OFF_SWITCH,
|
||||
THING_TYPE_ZB_ON_OFF_SWITCH_2UNITS, THING_TYPE_ZB_DIMMER, THING_TYPE_BUS_ON_OFF_SWITCH,
|
||||
THING_TYPE_BUS_DIMMER);
|
||||
// ## Automation
|
||||
public static final Set<ThingTypeUID> AUTOMATION_SUPPORTED_THING_TYPES = new HashSet<>(
|
||||
Arrays.asList(THING_TYPE_ZB_AUTOMATION, THING_TYPE_BUS_AUTOMATION));
|
||||
public static final Set<ThingTypeUID> AUTOMATION_SUPPORTED_THING_TYPES = Set.of(THING_TYPE_ZB_AUTOMATION,
|
||||
THING_TYPE_BUS_AUTOMATION);
|
||||
|
||||
// ## Thermoregulation
|
||||
public static final Set<ThingTypeUID> THERMOREGULATION_SUPPORTED_THING_TYPES = Set.of(THING_TYPE_BUS_THERMOSTAT,
|
||||
THING_TYPE_BUS_TEMP_SENSOR);
|
||||
|
||||
// ## Energy Management
|
||||
public static final Set<ThingTypeUID> ENERGY_MANAGEMENT_SUPPORTED_THING_TYPES = new HashSet<>(
|
||||
Arrays.asList(THING_TYPE_BUS_ENERGY_METER));
|
||||
public static final Set<ThingTypeUID> ENERGY_MANAGEMENT_SUPPORTED_THING_TYPES = Set.of(THING_TYPE_BUS_ENERGY_METER);
|
||||
|
||||
// ## Groups
|
||||
public static final Set<ThingTypeUID> DEVICE_SUPPORTED_THING_TYPES = Stream
|
||||
.of(LIGHTING_SUPPORTED_THING_TYPES, AUTOMATION_SUPPORTED_THING_TYPES,
|
||||
ENERGY_MANAGEMENT_SUPPORTED_THING_TYPES, GENERIC_SUPPORTED_THING_TYPES)
|
||||
THERMOREGULATION_SUPPORTED_THING_TYPES, ENERGY_MANAGEMENT_SUPPORTED_THING_TYPES,
|
||||
GENERIC_SUPPORTED_THING_TYPES)
|
||||
.flatMap(Collection::stream).collect(Collectors.toCollection(HashSet::new));
|
||||
|
||||
public static final Set<ThingTypeUID> BRIDGE_SUPPORTED_THING_TYPES = new HashSet<>(
|
||||
Arrays.asList(THING_TYPE_ZB_GATEWAY, THING_TYPE_BUS_GATEWAY));
|
||||
public static final Set<ThingTypeUID> BRIDGE_SUPPORTED_THING_TYPES = Set.of(THING_TYPE_ZB_GATEWAY,
|
||||
THING_TYPE_BUS_GATEWAY);
|
||||
|
||||
public static final Set<ThingTypeUID> ALL_SUPPORTED_THING_TYPES = Stream
|
||||
.of(DEVICE_SUPPORTED_THING_TYPES, BRIDGE_SUPPORTED_THING_TYPES).flatMap(Collection::stream)
|
||||
@@ -106,6 +113,16 @@ public class OpenWebNetBindingConstants {
|
||||
// automation
|
||||
public static final String CHANNEL_SHUTTER = "shutter";
|
||||
|
||||
// thermo
|
||||
public static final String CHANNEL_TEMPERATURE = "temperature";
|
||||
public static final String CHANNEL_FUNCTION = "function";
|
||||
public static final String CHANNEL_TEMP_SETPOINT = "setpointTemperature";
|
||||
public static final String CHANNEL_MODE = "mode";
|
||||
public static final String CHANNEL_FAN_SPEED = "speedFanCoil";
|
||||
public static final String CHANNEL_CONDITIONING_VALVE = "conditioningValve";
|
||||
public static final String CHANNEL_HEATING_VALVE = "heatingValve";
|
||||
public static final String CHANNEL_ACTUATOR = "actuator";
|
||||
|
||||
// energy management
|
||||
public static final String CHANNEL_POWER = "power";
|
||||
|
||||
|
||||
@@ -53,6 +53,7 @@ import org.openwebnet4j.message.FrameException;
|
||||
import org.openwebnet4j.message.GatewayMgmt;
|
||||
import org.openwebnet4j.message.Lighting;
|
||||
import org.openwebnet4j.message.OpenMessage;
|
||||
import org.openwebnet4j.message.Thermoregulation;
|
||||
import org.openwebnet4j.message.What;
|
||||
import org.openwebnet4j.message.Where;
|
||||
import org.openwebnet4j.message.WhereZigBee;
|
||||
@@ -64,7 +65,8 @@ import org.slf4j.LoggerFactory;
|
||||
* The {@link OpenWebNetBridgeHandler} is responsible for handling communication with gateways and handling events.
|
||||
*
|
||||
* @author Massimo Valla - Initial contribution
|
||||
* @author Andrea Conte - Energy management
|
||||
* @author Andrea Conte - Energy management, Thermoregulation
|
||||
* @author Gilberto Cocchi - Thermoregulation
|
||||
*/
|
||||
@NonNullByDefault
|
||||
public class OpenWebNetBridgeHandler extends ConfigStatusBridgeHandler implements GatewayListener {
|
||||
@@ -304,11 +306,9 @@ public class OpenWebNetBridgeHandler extends ConfigStatusBridgeHandler implement
|
||||
logger.warn("discoverByActivation: null OpenWebNetDeviceDiscoveryService, ignoring msg={}", baseMsg);
|
||||
return;
|
||||
}
|
||||
if (baseMsg instanceof Lighting || baseMsg instanceof Automation || baseMsg instanceof EnergyManagement) { // we
|
||||
// support
|
||||
// these
|
||||
// types
|
||||
// only
|
||||
// we support these types only
|
||||
if (baseMsg instanceof Lighting || baseMsg instanceof Automation || baseMsg instanceof EnergyManagement
|
||||
|| baseMsg instanceof Thermoregulation) {
|
||||
BaseOpenMessage bmsg = baseMsg;
|
||||
if (baseMsg instanceof Lighting) {
|
||||
What what = baseMsg.getWhat();
|
||||
@@ -418,7 +418,8 @@ public class OpenWebNetBridgeHandler extends ConfigStatusBridgeHandler implement
|
||||
|
||||
BaseOpenMessage baseMsg = (BaseOpenMessage) msg;
|
||||
// let's try to get the Thing associated with this message...
|
||||
if (baseMsg instanceof Lighting || baseMsg instanceof Automation || baseMsg instanceof EnergyManagement) {
|
||||
if (baseMsg instanceof Lighting || baseMsg instanceof Automation || baseMsg instanceof EnergyManagement
|
||||
|| baseMsg instanceof Thermoregulation) {
|
||||
String ownId = ownIdFromMessage(baseMsg);
|
||||
logger.debug("ownIdFromMessage({}) --> {}", baseMsg, ownId);
|
||||
OpenWebNetThingHandler deviceHandler = registeredDevices.get(ownId);
|
||||
|
||||
@@ -0,0 +1,337 @@
|
||||
/**
|
||||
* Copyright (c) 2010-2021 Contributors to the openHAB project
|
||||
*
|
||||
* See the NOTICE file(s) distributed with this work for additional
|
||||
* information.
|
||||
*
|
||||
* This program and the accompanying materials are made available under the
|
||||
* terms of the Eclipse Public License 2.0 which is available at
|
||||
* http://www.eclipse.org/legal/epl-2.0
|
||||
*
|
||||
* SPDX-License-Identifier: EPL-2.0
|
||||
*/
|
||||
package org.openhab.binding.openwebnet.handler;
|
||||
|
||||
import static org.openhab.binding.openwebnet.OpenWebNetBindingConstants.*;
|
||||
|
||||
import java.util.Set;
|
||||
|
||||
import org.eclipse.jdt.annotation.NonNullByDefault;
|
||||
import org.openhab.binding.openwebnet.OpenWebNetBindingConstants;
|
||||
import org.openhab.core.library.types.DecimalType;
|
||||
import org.openhab.core.library.types.QuantityType;
|
||||
import org.openhab.core.library.types.StringType;
|
||||
import org.openhab.core.library.unit.SIUnits;
|
||||
import org.openhab.core.thing.ChannelUID;
|
||||
import org.openhab.core.thing.Thing;
|
||||
import org.openhab.core.thing.ThingStatus;
|
||||
import org.openhab.core.thing.ThingStatusInfo;
|
||||
import org.openhab.core.thing.ThingTypeUID;
|
||||
import org.openhab.core.types.Command;
|
||||
import org.openhab.core.types.UnDefType;
|
||||
import org.openwebnet4j.communication.OWNException;
|
||||
import org.openwebnet4j.message.BaseOpenMessage;
|
||||
import org.openwebnet4j.message.FrameException;
|
||||
import org.openwebnet4j.message.MalformedFrameException;
|
||||
import org.openwebnet4j.message.Thermoregulation;
|
||||
import org.openwebnet4j.message.Where;
|
||||
import org.openwebnet4j.message.WhereThermo;
|
||||
import org.openwebnet4j.message.Who;
|
||||
import org.slf4j.Logger;
|
||||
import org.slf4j.LoggerFactory;
|
||||
|
||||
/**
|
||||
* The {@link OpenWebNetThermoregulationHandler} is responsible for handling commands/messages for a Thermoregulation
|
||||
* OpenWebNet device. It extends the abstract {@link OpenWebNetThingHandler}.
|
||||
*
|
||||
* @author Massimo Valla - Initial contribution
|
||||
* @author Andrea Conte - Thermoregulation
|
||||
* @author Gilberto Cocchi - Thermoregulation
|
||||
*/
|
||||
@NonNullByDefault
|
||||
public class OpenWebNetThermoregulationHandler extends OpenWebNetThingHandler {
|
||||
|
||||
private final Logger logger = LoggerFactory.getLogger(OpenWebNetThermoregulationHandler.class);
|
||||
|
||||
public final static Set<ThingTypeUID> SUPPORTED_THING_TYPES = OpenWebNetBindingConstants.THERMOREGULATION_SUPPORTED_THING_TYPES;
|
||||
|
||||
private boolean isTempSensor = false; // is the device a sensor or thermostat?
|
||||
|
||||
private double currentSetPointTemp = 11.5d; // 11.5 is the default setTemp used in MyHomeUP mobile app
|
||||
|
||||
private Thermoregulation.Function currentFunction = Thermoregulation.Function.GENERIC;
|
||||
|
||||
public OpenWebNetThermoregulationHandler(Thing thing) {
|
||||
super(thing);
|
||||
}
|
||||
|
||||
@Override
|
||||
public void bridgeStatusChanged(ThingStatusInfo bridgeStatusInfo) {
|
||||
super.bridgeStatusChanged(bridgeStatusInfo);
|
||||
// when the bridge is ONLINE request for thing states (temp, setTemp, fanSpeed...)
|
||||
if (bridgeStatusInfo.getStatus().equals(ThingStatus.ONLINE)) {
|
||||
refreshDevice(false);
|
||||
}
|
||||
}
|
||||
|
||||
@Override
|
||||
protected void handleChannelCommand(ChannelUID channel, Command command) {
|
||||
switch (channel.getId()) {
|
||||
case CHANNEL_TEMP_SETPOINT:
|
||||
handleSetpoint(command);
|
||||
break;
|
||||
case CHANNEL_FUNCTION:
|
||||
handleFunction(command);
|
||||
break;
|
||||
case CHANNEL_MODE:
|
||||
handleMode(command);
|
||||
break;
|
||||
case CHANNEL_FAN_SPEED:
|
||||
handleSetFanSpeed(command);
|
||||
break;
|
||||
default: {
|
||||
logger.warn("handleChannelCommand() Unsupported ChannelUID {}", channel.getId());
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
@Override
|
||||
protected void requestChannelState(ChannelUID channel) {
|
||||
refreshDevice(false);
|
||||
}
|
||||
|
||||
@Override
|
||||
protected Where buildBusWhere(String wStr) throws IllegalArgumentException {
|
||||
WhereThermo wt = new WhereThermo(wStr);
|
||||
if (wt.isProbe()) {
|
||||
isTempSensor = true;
|
||||
}
|
||||
return wt;
|
||||
}
|
||||
|
||||
@Override
|
||||
protected String ownIdPrefix() {
|
||||
return Who.THERMOREGULATION.value().toString();
|
||||
}
|
||||
|
||||
private void handleSetFanSpeed(Command command) {
|
||||
if (command instanceof StringType) {
|
||||
Where w = deviceWhere;
|
||||
if (w != null) {
|
||||
try {
|
||||
Thermoregulation.FanCoilSpeed speed = Thermoregulation.FanCoilSpeed.valueOf(command.toString());
|
||||
send(Thermoregulation.requestWriteFanCoilSpeed(w.value(), speed));
|
||||
} catch (OWNException e) {
|
||||
logger.warn("handleSetFanSpeed() {}", e.getMessage());
|
||||
} catch (IllegalArgumentException e) {
|
||||
logger.warn("handleSetFanSpeed() Unsupported command {} for thing {}", command,
|
||||
getThing().getUID());
|
||||
return;
|
||||
}
|
||||
}
|
||||
} else {
|
||||
logger.warn("handleSetFanSpeed() Unsupported command {} for thing {}", command, getThing().getUID());
|
||||
}
|
||||
}
|
||||
|
||||
private void handleSetpoint(Command command) {
|
||||
if (command instanceof QuantityType || command instanceof DecimalType) {
|
||||
Where w = deviceWhere;
|
||||
if (w != null) {
|
||||
double newTemp = 0;
|
||||
if (command instanceof QuantityType) {
|
||||
QuantityType<?> tempCelsius = ((QuantityType<?>) command).toUnit(SIUnits.CELSIUS);
|
||||
if (tempCelsius != null) {
|
||||
newTemp = tempCelsius.doubleValue();
|
||||
}
|
||||
} else {
|
||||
newTemp = ((DecimalType) command).doubleValue();
|
||||
}
|
||||
try {
|
||||
send(Thermoregulation.requestWriteSetpointTemperature(w.value(), newTemp, currentFunction));
|
||||
} catch (MalformedFrameException | OWNException e) {
|
||||
logger.warn("handleSetpoint() {}", e.getMessage());
|
||||
}
|
||||
}
|
||||
} else {
|
||||
logger.warn("handleSetpoint() Unsupported command {} for thing {}", command, getThing().getUID());
|
||||
}
|
||||
}
|
||||
|
||||
private void handleMode(Command command) {
|
||||
if (command instanceof StringType) {
|
||||
Where w = deviceWhere;
|
||||
if (w != null) {
|
||||
try {
|
||||
Thermoregulation.OperationMode mode = Thermoregulation.OperationMode.valueOf(command.toString());
|
||||
send(Thermoregulation.requestWriteMode(w.value(), mode, currentFunction, currentSetPointTemp));
|
||||
} catch (OWNException e) {
|
||||
logger.warn("handleMode() {}", e.getMessage());
|
||||
} catch (IllegalArgumentException e) {
|
||||
logger.warn("handleMode() Unsupported command {} for thing {}", command, getThing().getUID());
|
||||
return;
|
||||
}
|
||||
}
|
||||
} else {
|
||||
logger.warn("handleMode() Unsupported command {} for thing {}", command, getThing().getUID());
|
||||
}
|
||||
}
|
||||
|
||||
private void handleFunction(Command command) {
|
||||
if (command instanceof StringType) {
|
||||
Where w = deviceWhere;
|
||||
if (w != null) {
|
||||
try {
|
||||
Thermoregulation.Function function = Thermoregulation.Function.valueOf(command.toString());
|
||||
send(Thermoregulation.requestWriteFunction(w.value(), function));
|
||||
} catch (OWNException e) {
|
||||
logger.warn("handleFunction() {}", e.getMessage());
|
||||
} catch (IllegalArgumentException e) {
|
||||
logger.warn("handleFunction() Unsupported command {} for thing {}", command, getThing().getUID());
|
||||
return;
|
||||
}
|
||||
}
|
||||
} else {
|
||||
logger.warn("handleFunction() Unsupported command {} for thing {}", command, getThing().getUID());
|
||||
}
|
||||
}
|
||||
|
||||
@Override
|
||||
protected void handleMessage(BaseOpenMessage msg) {
|
||||
super.handleMessage(msg);
|
||||
if (msg.isCommand()) {
|
||||
updateModeAndFunction((Thermoregulation) msg);
|
||||
} else {
|
||||
if (msg.getDim() == null) {
|
||||
return;
|
||||
}
|
||||
if (msg.getDim() == Thermoregulation.DimThermo.TEMPERATURE
|
||||
|| msg.getDim() == Thermoregulation.DimThermo.PROBE_TEMPERATURE) {
|
||||
updateTemperature((Thermoregulation) msg);
|
||||
} else if (msg.getDim() == Thermoregulation.DimThermo.TEMP_SETPOINT
|
||||
|| msg.getDim() == Thermoregulation.DimThermo.COMPLETE_PROBE_STATUS) {
|
||||
updateSetpoint((Thermoregulation) msg);
|
||||
} else if (msg.getDim() == Thermoregulation.DimThermo.VALVES_STATUS) {
|
||||
updateValveStatus((Thermoregulation) msg);
|
||||
} else if (msg.getDim() == Thermoregulation.DimThermo.ACTUATOR_STATUS) {
|
||||
updateActuatorStatus((Thermoregulation) msg);
|
||||
} else if (msg.getDim() == Thermoregulation.DimThermo.FAN_COIL_SPEED) {
|
||||
updateFanCoilSpeed((Thermoregulation) msg);
|
||||
} else {
|
||||
logger.debug("handleMessage() Ignoring unsupported DIM {} for thing {}. Frame={}", msg.getDim(),
|
||||
getThing().getUID(), msg);
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
private void updateModeAndFunction(Thermoregulation tmsg) {
|
||||
if (tmsg.getWhat() == null) {
|
||||
logger.debug("updateModeAndFunction() Could not parse Mode or Function from {} (what is null)",
|
||||
tmsg.getFrameValue());
|
||||
return;
|
||||
}
|
||||
|
||||
Thermoregulation.WhatThermo w = Thermoregulation.WhatThermo.fromValue(tmsg.getWhat().value());
|
||||
|
||||
if (w.mode() == null) {
|
||||
logger.debug("updateModeAndFunction() Could not parse Mode from: {}", tmsg.getFrameValue());
|
||||
return;
|
||||
}
|
||||
if (w.function() == null) {
|
||||
logger.debug("updateModeAndFunction() Could not parse Function from: {}", tmsg.getFrameValue());
|
||||
return;
|
||||
}
|
||||
|
||||
Thermoregulation.OperationMode mode = w.mode();
|
||||
Thermoregulation.Function function = w.function();
|
||||
|
||||
if (w == Thermoregulation.WhatThermo.HEATING) {
|
||||
function = Thermoregulation.Function.HEATING;
|
||||
} else if (w == Thermoregulation.WhatThermo.CONDITIONING) {
|
||||
function = Thermoregulation.Function.COOLING;
|
||||
}
|
||||
|
||||
updateState(CHANNEL_MODE, new StringType(mode.toString()));
|
||||
updateState(CHANNEL_FUNCTION, new StringType(function.toString()));
|
||||
|
||||
// store current function
|
||||
currentFunction = function;
|
||||
}
|
||||
|
||||
private void updateTemperature(Thermoregulation tmsg) {
|
||||
try {
|
||||
double temp = Thermoregulation.parseTemperature(tmsg);
|
||||
updateState(CHANNEL_TEMPERATURE, getAsQuantityTypeOrNull(temp, SIUnits.CELSIUS));
|
||||
} catch (FrameException e) {
|
||||
logger.warn("updateTemperature() FrameException on frame {}: {}", tmsg, e.getMessage());
|
||||
updateState(CHANNEL_TEMPERATURE, UnDefType.UNDEF);
|
||||
}
|
||||
}
|
||||
|
||||
private void updateSetpoint(Thermoregulation tmsg) {
|
||||
try {
|
||||
double temp = Thermoregulation.parseTemperature(tmsg);
|
||||
updateState(CHANNEL_TEMP_SETPOINT, getAsQuantityTypeOrNull(temp, SIUnits.CELSIUS));
|
||||
currentSetPointTemp = temp;
|
||||
} catch (FrameException e) {
|
||||
logger.warn("updateSetpoint() FrameException on frame {}: {}", tmsg, e.getMessage());
|
||||
updateState(CHANNEL_TEMP_SETPOINT, UnDefType.UNDEF);
|
||||
}
|
||||
}
|
||||
|
||||
private void updateFanCoilSpeed(Thermoregulation tmsg) {
|
||||
try {
|
||||
Thermoregulation.FanCoilSpeed speed = Thermoregulation.parseFanCoilSpeed(tmsg);
|
||||
updateState(CHANNEL_FAN_SPEED, new StringType(speed.toString()));
|
||||
} catch (FrameException e) {
|
||||
logger.warn("updateFanCoilSpeed() FrameException on frame {}: {}", tmsg, e.getMessage());
|
||||
updateState(CHANNEL_FAN_SPEED, UnDefType.UNDEF);
|
||||
}
|
||||
}
|
||||
|
||||
private void updateValveStatus(Thermoregulation tmsg) {
|
||||
try {
|
||||
Thermoregulation.ValveOrActuatorStatus cv = Thermoregulation.parseValveStatus(tmsg,
|
||||
Thermoregulation.WhatThermo.CONDITIONING);
|
||||
updateState(CHANNEL_CONDITIONING_VALVE, new StringType(cv.toString()));
|
||||
|
||||
Thermoregulation.ValveOrActuatorStatus hv = Thermoregulation.parseValveStatus(tmsg,
|
||||
Thermoregulation.WhatThermo.HEATING);
|
||||
updateState(CHANNEL_HEATING_VALVE, new StringType(hv.toString()));
|
||||
} catch (FrameException e) {
|
||||
logger.warn("updateValveStatus() FrameException on frame {}: {}", tmsg, e.getMessage());
|
||||
updateState(CHANNEL_CONDITIONING_VALVE, UnDefType.UNDEF);
|
||||
updateState(CHANNEL_HEATING_VALVE, UnDefType.UNDEF);
|
||||
}
|
||||
}
|
||||
|
||||
private void updateActuatorStatus(Thermoregulation tmsg) {
|
||||
try {
|
||||
Thermoregulation.ValveOrActuatorStatus hv = Thermoregulation.parseActuatorStatus(tmsg);
|
||||
updateState(CHANNEL_ACTUATOR, new StringType(hv.toString()));
|
||||
} catch (FrameException e) {
|
||||
logger.warn("updateActuatorStatus() FrameException on frame {}: {}", tmsg, e.getMessage());
|
||||
updateState(CHANNEL_ACTUATOR, UnDefType.UNDEF);
|
||||
}
|
||||
}
|
||||
|
||||
@Override
|
||||
protected void refreshDevice(boolean refreshAll) {
|
||||
if (deviceWhere != null) {
|
||||
String w = deviceWhere.value();
|
||||
try {
|
||||
send(Thermoregulation.requestTemperature(w));
|
||||
if (!this.isTempSensor) {
|
||||
// for bus_thermostat request also other single channels updates
|
||||
send(Thermoregulation.requestSetPointTemperature(w));
|
||||
send(Thermoregulation.requestFanCoilSpeed(w));
|
||||
send(Thermoregulation.requestMode(w));
|
||||
send(Thermoregulation.requestValveStatus(w));
|
||||
send(Thermoregulation.requestActuatorStatus(w));
|
||||
}
|
||||
} catch (OWNException e) {
|
||||
logger.warn("refreshDevice() where='{}' returned OWNException {}", w, e.getMessage());
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -18,8 +18,12 @@ import java.util.Map;
|
||||
import java.util.concurrent.ScheduledFuture;
|
||||
import java.util.concurrent.TimeUnit;
|
||||
|
||||
import javax.measure.Quantity;
|
||||
import javax.measure.Unit;
|
||||
|
||||
import org.eclipse.jdt.annotation.NonNullByDefault;
|
||||
import org.eclipse.jdt.annotation.Nullable;
|
||||
import org.openhab.core.library.types.QuantityType;
|
||||
import org.openhab.core.thing.Bridge;
|
||||
import org.openhab.core.thing.ChannelUID;
|
||||
import org.openhab.core.thing.Thing;
|
||||
@@ -28,6 +32,8 @@ import org.openhab.core.thing.ThingStatusDetail;
|
||||
import org.openhab.core.thing.binding.BaseThingHandler;
|
||||
import org.openhab.core.types.Command;
|
||||
import org.openhab.core.types.RefreshType;
|
||||
import org.openhab.core.types.State;
|
||||
import org.openhab.core.types.UnDefType;
|
||||
import org.openwebnet4j.OpenGateway;
|
||||
import org.openwebnet4j.communication.OWNException;
|
||||
import org.openwebnet4j.communication.Response;
|
||||
@@ -221,6 +227,17 @@ public abstract class OpenWebNetThingHandler extends BaseThingHandler {
|
||||
super.dispose();
|
||||
}
|
||||
|
||||
/**
|
||||
* Helper method to return a Quantity from a Number value or UnDefType.NULL if value is null
|
||||
*
|
||||
* @param value to be used
|
||||
* @param unit to be used
|
||||
* @return Quantity
|
||||
*/
|
||||
protected <U extends Quantity<U>> State getAsQuantityTypeOrNull(@Nullable Number value, Unit<U> unit) {
|
||||
return value == null ? UnDefType.NULL : new QuantityType<>(value, unit);
|
||||
}
|
||||
|
||||
/**
|
||||
* Returns a prefix String for ownId specific for each handler. To be implemented by sub-classes.
|
||||
*
|
||||
|
||||
@@ -21,6 +21,7 @@ import org.openhab.binding.openwebnet.handler.OpenWebNetBridgeHandler;
|
||||
import org.openhab.binding.openwebnet.handler.OpenWebNetEnergyHandler;
|
||||
import org.openhab.binding.openwebnet.handler.OpenWebNetGenericHandler;
|
||||
import org.openhab.binding.openwebnet.handler.OpenWebNetLightingHandler;
|
||||
import org.openhab.binding.openwebnet.handler.OpenWebNetThermoregulationHandler;
|
||||
import org.openhab.core.thing.Bridge;
|
||||
import org.openhab.core.thing.Thing;
|
||||
import org.openhab.core.thing.ThingTypeUID;
|
||||
@@ -35,7 +36,8 @@ import org.slf4j.LoggerFactory;
|
||||
* The {@link OpenWebNetHandlerFactory} is responsible for creating thing handlers.
|
||||
*
|
||||
* @author Massimo Valla - Initial contribution
|
||||
* @author Andrea Conte - Energy management
|
||||
* @author Andrea Conte - Energy management, Thermoregulation
|
||||
* @author Gilberto Cocchi - Thermoregulation
|
||||
*/
|
||||
@NonNullByDefault
|
||||
@Component(configurationPid = "binding.openwebnet", service = ThingHandlerFactory.class)
|
||||
@@ -65,6 +67,9 @@ public class OpenWebNetHandlerFactory extends BaseThingHandlerFactory {
|
||||
} else if (OpenWebNetEnergyHandler.SUPPORTED_THING_TYPES.contains(thing.getThingTypeUID())) {
|
||||
logger.debug("creating NEW ENERGY Handler");
|
||||
return new OpenWebNetEnergyHandler(thing);
|
||||
} else if (OpenWebNetThermoregulationHandler.SUPPORTED_THING_TYPES.contains(thing.getThingTypeUID())) {
|
||||
logger.debug("creating NEW THERMO Handler");
|
||||
return new OpenWebNetThermoregulationHandler(thing);
|
||||
}
|
||||
logger.warn("ThingType {} is not supported by this binding", thing.getThingTypeUID());
|
||||
return null;
|
||||
|
||||
@@ -41,7 +41,8 @@ import org.slf4j.LoggerFactory;
|
||||
* bridge/gateway
|
||||
*
|
||||
* @author Massimo Valla - Initial contribution
|
||||
* @author Andrea Conte - Energy management
|
||||
* @author Andrea Conte - Energy management, Thermoregulation
|
||||
* @author Gilberto Cocchi - Thermoregulation
|
||||
*/
|
||||
@NonNullByDefault
|
||||
public class OpenWebNetDeviceDiscoveryService extends AbstractDiscoveryService
|
||||
@@ -130,14 +131,28 @@ public class OpenWebNetDeviceDiscoveryService extends AbstractDiscoveryService
|
||||
deviceWho = Who.AUTOMATION;
|
||||
break;
|
||||
}
|
||||
|
||||
case SCS_TEMP_SENSOR: {
|
||||
thingTypeUID = OpenWebNetBindingConstants.THING_TYPE_BUS_TEMP_SENSOR;
|
||||
thingLabel = OpenWebNetBindingConstants.THING_LABEL_BUS_TEMP_SENSOR;
|
||||
deviceWho = Who.THERMOREGULATION;
|
||||
break;
|
||||
}
|
||||
case SCS_THERMOSTAT: {
|
||||
thingTypeUID = OpenWebNetBindingConstants.THING_TYPE_BUS_THERMOSTAT;
|
||||
thingLabel = OpenWebNetBindingConstants.THING_LABEL_BUS_THERMOSTAT;
|
||||
deviceWho = Who.THERMOREGULATION;
|
||||
break;
|
||||
}
|
||||
case SCS_THERMO_CENTRAL_UNIT: {
|
||||
logger.warn("newDiscoveryResult() deviceType={} is not supported yet (WHERE={})", deviceType, where);
|
||||
break;
|
||||
}
|
||||
case SCS_ENERGY_METER: {
|
||||
thingTypeUID = OpenWebNetBindingConstants.THING_TYPE_BUS_ENERGY_METER;
|
||||
thingLabel = OpenWebNetBindingConstants.THING_LABEL_BUS_ENERGY_METER;
|
||||
deviceWho = Who.ENERGY_MANAGEMENT;
|
||||
break;
|
||||
}
|
||||
|
||||
default:
|
||||
logger.warn("Device type {} is not supported, default to GENERIC device (WHERE={})", deviceType, where);
|
||||
if (where instanceof WhereZigBee) {
|
||||
@@ -161,7 +176,7 @@ public class OpenWebNetDeviceDiscoveryService extends AbstractDiscoveryService
|
||||
|
||||
DiscoveryResult discoveryResult = null;
|
||||
|
||||
String whereConfig = where.value();
|
||||
String whereConfig = bridgeHandler.normalizeWhere(where);
|
||||
if (where instanceof WhereZigBee && WhereZigBee.UNIT_02.equals(((WhereZigBee) where).getUnit())) {
|
||||
logger.debug("UNIT=02 found (WHERE={}) -> will remove previous result if exists", where);
|
||||
thingRemoved(thingUID); // remove previously discovered thing
|
||||
|
||||
@@ -0,0 +1,35 @@
|
||||
<?xml version="1.0" encoding="UTF-8"?>
|
||||
<thing:thing-descriptions bindingId="openwebnet"
|
||||
xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
|
||||
xmlns:thing="https://openhab.org/schemas/thing-description/v1.0.0"
|
||||
xsi:schemaLocation="https://openhab.org/schemas/thing-description/v1.0.0 https://openhab.org/schemas/thing-description-1.0.0.xsd">
|
||||
|
||||
<!-- Thing for BUS Temperature Sensor -->
|
||||
<thing-type id="bus_temp_sensor">
|
||||
<supported-bridge-type-refs>
|
||||
<bridge-type-ref id="bus_gateway"/>
|
||||
</supported-bridge-type-refs>
|
||||
<label>Temperature Sensor</label>
|
||||
<description>A OpenWebNet BUS/SCS temperature sensor. BTicino models: L/N/NT4577 etc.</description>
|
||||
|
||||
<channels>
|
||||
<channel id="temperature" typeId="temperature"/>
|
||||
</channels>
|
||||
|
||||
<properties>
|
||||
<property name="vendor">BTicino/Legrand</property>
|
||||
<property name="model">BTI-L/N/NT4577 etc.</property>
|
||||
<property name="ownDeviceType">---</property>
|
||||
</properties>
|
||||
|
||||
<representation-property>ownId</representation-property>
|
||||
|
||||
<config-description>
|
||||
<parameter name="where" type="text" required="true">
|
||||
<label>OpenWebNet Device Address</label>
|
||||
<description>Example: Zone 2 --> where=2. For external sensors: sensor 5 --> where=500</description>
|
||||
</parameter>
|
||||
</config-description>
|
||||
|
||||
</thing-type>
|
||||
</thing:thing-descriptions>
|
||||
@@ -0,0 +1,45 @@
|
||||
<?xml version="1.0" encoding="UTF-8"?>
|
||||
<thing:thing-descriptions bindingId="openwebnet"
|
||||
xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
|
||||
xmlns:thing="https://openhab.org/schemas/thing-description/v1.0.0"
|
||||
xsi:schemaLocation="https://openhab.org/schemas/thing-description/v1.0.0 https://openhab.org/schemas/thing-description-1.0.0.xsd">
|
||||
|
||||
<!-- Thing for BUS Thermostat (BTicino xxx/xxx/...) -->
|
||||
<thing-type id="bus_thermostat">
|
||||
<supported-bridge-type-refs>
|
||||
<bridge-type-ref id="bus_gateway"/>
|
||||
</supported-bridge-type-refs>
|
||||
|
||||
<label>Thermostat (stand-alone)</label>
|
||||
<description>A OpenWebNet BUS/SCS zone stand-alone thermostat. BTicino models: LN4691.</description>
|
||||
|
||||
<channels>
|
||||
<!-- read only -->
|
||||
<channel id="temperature" typeId="temperature"/>
|
||||
<channel id="conditioningValve" typeId="conditioningValve"/>
|
||||
<channel id="heatingValve" typeId="heatingValve"/>
|
||||
<channel id="actuator" typeId="actuator"/>
|
||||
<!-- read/write -->
|
||||
<channel id="setpointTemperature" typeId="setpointTemperature"/>
|
||||
<channel id="function" typeId="function"/>
|
||||
<channel id="mode" typeId="mode"/>
|
||||
<channel id="speedFanCoil" typeId="speedFanCoil"/>
|
||||
</channels>
|
||||
|
||||
<properties>
|
||||
<property name="vendor">BTicino/Legrand</property>
|
||||
<property name="model">BTI-LN4691</property>
|
||||
<property name="ownDeviceType">410/420/430</property>
|
||||
</properties>
|
||||
|
||||
<representation-property>ownId</representation-property>
|
||||
|
||||
<config-description>
|
||||
<parameter name="where" type="text" required="true">
|
||||
<label>OpenWebNet Device Address</label>
|
||||
<description>Example: Zone 2 --> where=2.</description>
|
||||
</parameter>
|
||||
</config-description>
|
||||
|
||||
</thing-type>
|
||||
</thing:thing-descriptions>
|
||||
@@ -29,7 +29,7 @@
|
||||
<!-- Shutter Channel -->
|
||||
<channel-type id="shutter">
|
||||
<item-type>Rollershutter</item-type>
|
||||
<label>Roller shutter</label>
|
||||
<label>Roller Shutter</label>
|
||||
<description>Control the roller shutter position</description>
|
||||
<category>Blinds</category>
|
||||
<tags>
|
||||
@@ -37,6 +37,135 @@
|
||||
</tags>
|
||||
</channel-type>
|
||||
|
||||
<!-- Thermo channels -->
|
||||
<channel-type id="temperature">
|
||||
<item-type>Number:Temperature</item-type>
|
||||
<label>Temperature</label>
|
||||
<description>Current temperature (read only)</description>
|
||||
<category>Temperature</category>
|
||||
<tags>
|
||||
<tag>CurrentTemperature</tag>
|
||||
</tags>
|
||||
<state readOnly="true" pattern="%.1f %unit%"/>
|
||||
</channel-type>
|
||||
|
||||
<channel-type id="function">
|
||||
<item-type>String</item-type>
|
||||
<label>Thermo Function</label>
|
||||
<description>Thermo function of the thermostat (read/write)</description>
|
||||
<state>
|
||||
<options>
|
||||
<option value="HEATING">Heating</option>
|
||||
<option value="COOLING">Cooling</option>
|
||||
<option value="GENERIC">Generic</option>
|
||||
</options>
|
||||
</state>
|
||||
</channel-type>
|
||||
|
||||
<channel-type id="setpointTemperature">
|
||||
<item-type>Number:Temperature</item-type>
|
||||
<label>Setpoint Temperature</label>
|
||||
<description>Setpoint temperature (read/write)</description>
|
||||
<category>Temperature</category>
|
||||
<tags>
|
||||
<tag>TargetTemperature</tag>
|
||||
</tags>
|
||||
<state pattern="%.1f %unit%" step="0.5"/>
|
||||
</channel-type>
|
||||
|
||||
<channel-type id="mode">
|
||||
<item-type>String</item-type>
|
||||
<label>Mode</label>
|
||||
<description>Set mode of the thermostat (read/write)</description>
|
||||
<state>
|
||||
<options>
|
||||
<option value="MANUAL">Manual</option>
|
||||
<option value="PROTECTION">Protection</option>
|
||||
<option value="OFF">Off</option>
|
||||
</options>
|
||||
</state>
|
||||
</channel-type>
|
||||
|
||||
<channel-type id="speedFanCoil">
|
||||
<item-type>String</item-type>
|
||||
<label>Set Fan Speed</label>
|
||||
<description>Set speed of the Fan Coil (read/write)</description>
|
||||
<state>
|
||||
<options>
|
||||
<option value="AUTO">Auto</option>
|
||||
<option value="SPEED_1">Fan speed 1</option>
|
||||
<option value="SPEED_2">Fan speed 2</option>
|
||||
<option value="SPEED_3">Fan speed 3</option>
|
||||
</options>
|
||||
</state>
|
||||
</channel-type>
|
||||
|
||||
<channel-type id="conditioningValve" advanced="true">
|
||||
<item-type>String</item-type>
|
||||
<label>Conditioning Valve</label>
|
||||
<description>Conditioning Valve status (read only)</description>
|
||||
<state readOnly="true">
|
||||
<options>
|
||||
<option value="OFF">OFF</option>
|
||||
<option value="ON">ON</option>
|
||||
<option value="OPENED">Opened</option>
|
||||
<option value="CLOSED">Closed</option>
|
||||
<option value="STOP">Stop</option>
|
||||
<option value="OFF_FAN_COIL">OFF Fan Coil</option>
|
||||
<option value="ON_SPEED_1">ON speed 1</option>
|
||||
<option value="ON_SPEED_2">ON speed 2</option>
|
||||
<option value="ON_SPEED_3">ON speed 3</option>
|
||||
<option value="OFF_SPEED_1">OFF speed 1</option>
|
||||
<option value="OFF_SPEED_2">OFF speed 2</option>
|
||||
<option value="OFF_SPEED_3">OFF speed 3</option>
|
||||
</options>
|
||||
</state>
|
||||
</channel-type>
|
||||
|
||||
<channel-type id="heatingValve" advanced="true">
|
||||
<item-type>String</item-type>
|
||||
<label>Heating Valve</label>
|
||||
<description>Heating Valve status (read only)</description>
|
||||
<state readOnly="true">
|
||||
<options>
|
||||
<option value="OFF">OFF</option>
|
||||
<option value="ON">ON</option>
|
||||
<option value="OPENED">Opened</option>
|
||||
<option value="CLOSED">Closed</option>
|
||||
<option value="STOP">Stop</option>
|
||||
<option value="OFF_FAN_COIL">OFF Fan Coil</option>
|
||||
<option value="ON_SPEED_1">ON speed 1</option>
|
||||
<option value="ON_SPEED_2">ON speed 2</option>
|
||||
<option value="ON_SPEED_3">ON speed 3</option>
|
||||
<option value="OFF_SPEED_1">OFF speed 1</option>
|
||||
<option value="OFF_SPEED_2">OFF speed 2</option>
|
||||
<option value="OFF_SPEED_3">OFF speed 3</option>
|
||||
</options>
|
||||
</state>
|
||||
</channel-type>
|
||||
|
||||
<channel-type id="actuator" advanced="true">
|
||||
<item-type>String</item-type>
|
||||
<label>Actuator Status</label>
|
||||
<description>Actuator status (read only)</description>
|
||||
<state readOnly="true">
|
||||
<options>
|
||||
<option value="OFF">OFF</option>
|
||||
<option value="ON">ON</option>
|
||||
<option value="OPENED">Opened</option>
|
||||
<option value="CLOSED">Closed</option>
|
||||
<option value="STOP">Stop</option>
|
||||
<option value="OFF_FAN_COIL">OFF Fan Coil</option>
|
||||
<option value="ON_SPEED_1">ON speed 1</option>
|
||||
<option value="ON_SPEED_2">ON speed 2</option>
|
||||
<option value="ON_SPEED_3">ON speed 3</option>
|
||||
<option value="OFF_SPEED_1">OFF speed 1</option>
|
||||
<option value="OFF_SPEED_2">OFF speed 2</option>
|
||||
<option value="OFF_SPEED_3">OFF speed 3</option>
|
||||
</options>
|
||||
</state>
|
||||
</channel-type>
|
||||
|
||||
<!-- Energy channels -->
|
||||
<channel-type id="power">
|
||||
<item-type>Number:Power</item-type>
|
||||
|
||||
@@ -24,6 +24,7 @@ import org.openwebnet4j.message.FrameException;
|
||||
import org.openwebnet4j.message.Where;
|
||||
import org.openwebnet4j.message.WhereEnergyManagement;
|
||||
import org.openwebnet4j.message.WhereLightAutom;
|
||||
import org.openwebnet4j.message.WhereThermo;
|
||||
import org.openwebnet4j.message.WhereZigBee;
|
||||
import org.openwebnet4j.message.Who;
|
||||
import org.slf4j.Logger;
|
||||
@@ -55,11 +56,12 @@ public class OwnIdTest {
|
||||
* BUS Local Bus 25#4#01 25h4h01 1.25h4h01 25h4h01
|
||||
* BUS Autom 93 93 2.93 93
|
||||
* BUS Thermo #1 or 1 1 4.1 1
|
||||
* BUS Thermo actuator 1#2 1 4.1 1
|
||||
* BUS TempSensor 500 500 4.500 500
|
||||
* BUS Energy 51 51 18.51 51
|
||||
* BUS CEN 51 51 15.51 51
|
||||
* BUS CEN+ 212 212 25.212 212
|
||||
* BUS DryContact 399 399 25.399 399
|
||||
* -INACTIVE- BUS CEN 51 51 15.51 51
|
||||
* -INACTIVE- BUS CEN+ 212 212 25.212 212
|
||||
* -INACTIVE- BUS DryContact 399 399 25.399 399
|
||||
*
|
||||
*/
|
||||
// @formatter:on
|
||||
@@ -71,10 +73,11 @@ public class OwnIdTest {
|
||||
zb_switch_2u_2(new WhereZigBee("789301202#9"), Who.fromValue(1), "*1*1*789301202#9##", "789301200h9", "1.789301200h9", "789301200h9"),
|
||||
bus_switch(new WhereLightAutom("51"), Who.fromValue(1), "*1*1*51##", "51", "1.51", "51"),
|
||||
bus_localbus(new WhereLightAutom("25#4#01"), Who.fromValue(1), "*1*1*25#4#01##", "25h4h01", "1.25h4h01", "25h4h01"),
|
||||
//bus_thermo_zone(new WhereThermo("1"), Who.fromValue(4),"*#4*1*0*0020##" , "1", "4.1", "1"),
|
||||
//bus_thermo_zone_act(new WhereThermo("2#1"), Who.fromValue(4),"*#4*2#1*20*0##" ,"2", "4.2", "2"),
|
||||
//bus_thermo_via_cu(new WhereThermo("#1"), Who.fromValue(4),"*#4*#1*0*0020##" ,"1", "4.1", "1"),
|
||||
// bus_tempSensor("500", "4", "500", "4.500", "500"),
|
||||
bus_autom(new WhereLightAutom("93"), Who.fromValue(2), "*2*0*93##", "93", "2.93", "93"),
|
||||
bus_thermo_via_cu(new WhereThermo("#1"), Who.fromValue(4),"*#4*#1*0*0020##" ,"1", "4.1", "1"),
|
||||
bus_thermo(new WhereThermo("1"), Who.fromValue(4),"*#4*1*0*0020##" , "1", "4.1", "1"),
|
||||
bus_thermo_act(new WhereThermo("1#2"), Who.fromValue(4),"*#4*1#2*20*0##" ,"1", "4.1", "1"),
|
||||
bus_tempSensor(new WhereThermo("500"), Who.fromValue(4), "*#4*500*15*1*0020*0001##", "500", "4.500", "500"),
|
||||
bus_energy(new WhereEnergyManagement("51"), Who.fromValue(18), "*#18*51*113##", "51", "18.51", "51");
|
||||
|
||||
// @formatter:on
|
||||
|
||||
Reference in New Issue
Block a user