[lcn] doc: add .things example (#9031)
Signed-off-by: Fabian Wolter <github@fabian-wolter.de>
This commit is contained in:
parent
3b162f2f92
commit
3fbb07d8c6
@ -96,7 +96,7 @@ Basic data like the names of all LCN modules in the bus, can be read out by open
|
||||
If not all LCN modules get listed on the first run, click on the refresh button to start another scan.
|
||||
|
||||
When adding a module by discovery, the new *Thing*'s UID will be a combination of segment and module id using the following format:
|
||||
*S<segmentId>M<moduleId>* where *segmentId* and *moduleId* are formatted as three-digit numbers with leading zeros.
|
||||
`S<segmentId>M<moduleId>` where `segmentId` and `moduleId` are formatted as three-digit numbers with leading zeros.
|
||||
|
||||
### Discover PCK Gateways
|
||||
|
||||
@ -423,7 +423,21 @@ LEDs do not support the *OnOffCommand* and respectively the *Switch* Item type,
|
||||
|
||||
## Full Example
|
||||
|
||||
Config .items
|
||||
Config `.things`
|
||||
|
||||
```
|
||||
Bridge lcn:pckGateway:myPCHK [ hostname="192.168.123.123", port=4114, username="myUser", password="myPassword", mode="native200" ] {
|
||||
Thing module M99 "M99 MyModule" [ moduleId=99, segmentId=0 ] {
|
||||
Channels:
|
||||
Rollershutter : rollershutterrelay#1 "My twisted rollershutter relay" [ invertUpDown = true ]
|
||||
Contact : binarysensor#6 [ invertState=true ]
|
||||
Number : rvarsetpoint#1 [ unit="temperature" ]
|
||||
Number : variable#3 [ unit="temperature" ]
|
||||
}
|
||||
}
|
||||
```
|
||||
|
||||
Config `.items`
|
||||
|
||||
```
|
||||
// Dimmer Outputs
|
||||
@ -496,7 +510,7 @@ Switch M10_KeyLockA1 {channel="lcn:module:b827ebfea4bb:S000M010:keylocktablea#1"
|
||||
Switch M10_KeyLockD5 {channel="lcn:module:b827ebfea4bb:S000M010:keylocktabled#5"}
|
||||
```
|
||||
|
||||
Config .sitemap
|
||||
Config `.sitemap`
|
||||
|
||||
```
|
||||
sitemap lcn label="My home automation" {
|
||||
|
||||