[shelly] Auto-numbering for channel labels & bugfixes (#13066)
* - new device types added - min firmware set to 1.8.2 - unit for gas concentration fixed (ppm) - Auto numbering on channel labels for groups with multiple instances (add sequence suffix) - API and Thing interfaces defined to restrict access to those classes - fix on TRV boost update via CoAP - fix for status.temperature and status.uptime, internalTemp channels - don’t use meter timestamp if not present (RGBW2) - low battery indicator for sensor devices fixed - device detection based on model/type improved - various messages/translations fixed/improved - README updated (missing thing types added) Signed-off-by: Markus Michels <markus7017@gmail.com> (github: markus7017) Signed-off-by: Markus Michels <markus7017@gmail.com> * missing properties added Signed-off-by: Markus Michels <markus7017@gmail.com> (github: markus7017) Signed-off-by: Markus Michels <markus7017@gmail.com> * minor changes Signed-off-by: Markus Michels <markus7017@gmail.com> (github: markus7017) Signed-off-by: Markus Michels <markus7017@gmail.com> * markdown fixed Signed-off-by: Markus Michels <markus7017@gmail.com> (github: markus7017) Signed-off-by: Markus Michels <markus7017@gmail.com> * review changes applied Signed-off-by: Markus Michels <markus7017@gmail.com> * shelly_de.properties restored from main branch Signed-off-by: Markus Michels <markus7017@gmail.com>
This commit is contained in:
@@ -45,8 +45,10 @@ Also check out the [Shelly Manager](doc/ShellyManager.md), which
|
||||
| shellyplugs | Shelly Plug-S | SHPLG-S |
|
||||
| shellyem | Shelly EM with integrated Power Meters | SHEM |
|
||||
| shellyem3 | Shelly 3EM with 3 integrated Power Meter | SHEM-3 |
|
||||
| shellyrgbw2 | Shelly RGB Controller | SHRGBW2 |
|
||||
| shellybulb | Shelly Bulb in Color or White Mode | SHBLB-1 |
|
||||
| shellyrgbw2-color | Shelly RGBW2 Controller in Color Mode | SHRGBW2 |
|
||||
| shellyrgbw2-white | Shelly RGBW2 Controller in White Mode | SHRGBW2 |
|
||||
| shellybulb-color | Shelly Bulb in Color Mode | SHBLB-1 |
|
||||
| shellybulb-white | Shelly Bulb in White Mode | SHBLB-1 |
|
||||
| shellybulbduo | Shelly Duo White | SHBDUO-1 |
|
||||
| shellybulbduo | Shelly Duo White G10 | SHBDUO-1 |
|
||||
| shellycolorbulb | Shelly Duo Color G10 | SHCB-1 |
|
||||
@@ -55,6 +57,7 @@ Also check out the [Shelly Manager](doc/ShellyManager.md), which
|
||||
| shellyflood | Shelly Flood Sensor | SHWT-1 |
|
||||
| shellysmoke | Shelly Smoke Sensor | SHSM-1 |
|
||||
| shellymotion | Shelly Motion Sensor | SHMOS-01 |
|
||||
| shellymotion2 | Shelly Motion Sensor 2 | SHMOS-02 |
|
||||
| shellygas | Shelly Gas Sensor | SHGS-1 |
|
||||
| shellydw | Shelly Door/Window | SHDW-1 |
|
||||
| shellydw2 | Shelly Door/Window 2 | SHDW-2 |
|
||||
@@ -742,6 +745,23 @@ Using the Thing configuration option `brightnessAutoOn` you could decide if the
|
||||
`true`: Brightness will be set and device output is powered = light turns on with the new brightness
|
||||
`false`: Brightness will be set, but output stays unchanged so light will not be switched on when it's currently off.
|
||||
|
||||
### Shelly RGBW2 in White Mode (thing-type: shellyrgbw2-color)
|
||||
|
||||
|Group |Channel |Type |read-only|Description |
|
||||
|----------|-------------|---------|---------|-----------------------------------------------------------------------|
|
||||
|control |power |Switch |r/w |Switch light ON/OFF |
|
||||
| |input |Switch |yes |State of Input |
|
||||
| |autoOn |Number |r/w |Sets a timer to turn the device ON after every OFF; in sec |
|
||||
| |autoOff |Number |r/w |Sets a timer to turn the device OFF after every ON: in sec |
|
||||
| |timerActive |Switch |yes |ON: An auto-on/off timer is active |
|
||||
|color | | | |Color settings: only valid in COLOR mode |
|
||||
| |hsb |HSB |r/w |Represents the color picker (HSBType), control r/g/b, but not white |
|
||||
|meter |currentWatts |Number |yes |Current power consumption in Watts (all channels) |
|
||||
|
||||
Please note that the settings of channel group color are only valid in color mode and vice versa for white mode.
|
||||
The current firmware doesn't support the timestamp report for the meters.
|
||||
The binding emulates this by using the system time on every update.
|
||||
|
||||
### Shelly RGBW2 in White Mode (thing-type: shellyrgbw2-white)
|
||||
|
||||
|Group |Channel |Type |read-only|Description |
|
||||
@@ -845,6 +865,23 @@ You have a Motion controlling your light.
|
||||
You switch off the light and want to leave the room, but the motion sensor immediately switches light back on.
|
||||
Using 'sensorSleepTime' you could suppress motion events while leaving the room, e.g. for 5sec and the light doesn's switch on.
|
||||
|
||||
### Shelly Motion 2 (thing-type: shellymotion2)
|
||||
|
||||
|Group |Channel |Type |read-only|Description |
|
||||
|----------|---------------|---------|---------|---------------------------------------------------------------------|
|
||||
|sensors |motion |Switch |yes |ON: Motion was detected |
|
||||
| |motionTimestamp|DateTime |yes |Time when motion started/was detected |
|
||||
| |lux |Number |yes |Brightness in Lux |
|
||||
| |illumination |String |yes |Current illumination: dark/twilight/bright |
|
||||
| |temperature |Number |yes |Temperature measured by the sensor |
|
||||
| |vibration |Switch |yes |ON: Vibration detected |
|
||||
| |charger |Switch |yes |ON: USB charging cable is connected external power supply activated. |
|
||||
| |motionActive |Switch |yes |ON: Motion detection is currently active |
|
||||
| |sensorSleepTime|Number |no |Specifies the number of sec the sensor should not report events ]
|
||||
| |lastUpdate |DateTime |yes |Timestamp of the last update (any sensor value changed) |
|
||||
|battery |batteryLevel |Number |yes |Battery Level in % |
|
||||
| |lowBattery |Switch |yes |Low battery alert (< 20%) |
|
||||
|
||||
### Shelly TRV (thing-type: shellytrv)
|
||||
|
||||
Note: You might need to reboot the device to enable the discovery mode for 3 minutes(use the Web UI).
|
||||
|
||||
Reference in New Issue