[tado] Channels are visible depending on device type and capabilities (#13301)
* [tado] create zone channels dynamically * [tado] add JUnit test classes * [tado] eliminate maven compiler warnings * [tado] code optimisation * [tado] read me * [tado] current temperature & humidity also dynamic * [tado] battery/window channels * [tado] simplify channel builder * [tado] fix bundle initialisation bug * [tado] fix insert positions * [tado] add channel type categories * [tado] refactor battery checker * [tado] create capabilities support in caller vs callee * [tado] method doesn't throw exception * [tado] remove new line * [velux] add self to code owners * [tado] capitalize categories Signed-off-by: Andrew Fiddian-Green <software@whitebear.ch>
This commit is contained in:
committed by
GitHub
parent
8d9dfb20e3
commit
5c7eaa33ac
@@ -66,21 +66,23 @@ Name | Type | Description | Read/Write | Zone type
|
||||
-|-|-|-|-
|
||||
`currentTemperature` | Number:Temperature | Current inside temperature | R | `HEATING`, `AC`
|
||||
`humidity` | Number | Current relative inside humidity in percent | R | `HEATING`, `AC`
|
||||
`heatingPower` | Number | Amount of heating power currently present | R | `HEATING`
|
||||
`acPower` | Switch | Indicates if the Air-Conditioning is Off or On | R | `AC`
|
||||
`hvacMode` | String | Active mode, one of `OFF`, `HEAT`, `COOL`, `DRY`, `FAN`, `AUTO` | RW | `HEATING` and `DHW` support `OFF` and `HEAT`, `AC` can support more
|
||||
`targetTemperature` | Number:Temperature | Set point | RW | `HEATING`, `AC`, `DHW`
|
||||
`operationMode` | String | Operation mode the zone is currently in. One of `SCHEDULE` (follow smart schedule), `MANUAL` (override until ended manually), `TIMER` (override for a given time), `UNTIL_CHANGE` (active until next smart schedule block or until AWAY mode becomes active) | RW | `HEATING`, `AC`, `DHW`
|
||||
`overlayExpiry` | DateTime | End date and time of a timer | R | `HEATING`, `AC`, `DHW`
|
||||
`timerDuration` | Number | Timer duration in minutes | RW | `HEATING`, `AC`, `DHW`
|
||||
`heatingPower` | Number | Amount of heating power currently present | R | `HEATING`
|
||||
`acPower` | Switch | Indicates if the Air-Conditioning is Off or On | R | `AC`
|
||||
`fanspeed`<sup>1)</sup> | String | Fan speed, one of `AUTO`, `LOW`, `MIDDLE`, `HIGH` | RW | `AC`
|
||||
`fanLevel`<sup>1)</sup> | String | Fan speed, one of <sup>3)</sup> `AUTO`, `SILENT`, `LEVEL1`, `LEVEL2`, `LEVEL3`, `LEVEL4`, `LEVEL5` | RW | `AC`
|
||||
`swing`<sup>2)</sup> | Switch | Swing on/off | RW | `AC`
|
||||
`verticalSwing`<sup>2)</sup> | String | Vertical swing state, one of <sup>3)</sup> `OFF`, `ON`, `UP`, `MID_UP`, `MID`, `MID_DOWN`, `DOWN`, `AUTO` | RW | `AC`
|
||||
`horizontalSwing`<sup>2)</sup> | String | Horizontal swing state, one of <sup>3)</sup> `OFF`, `ON`, `LEFT`, `MID_LEFT`, `MID`, `MID_RIGHT`, `RIGHT`, `AUTO` | RW | `AC`
|
||||
`overlayExpiry` | DateTime | End date and time of a timer | R | `HEATING`, `AC`, `DHW`
|
||||
`timerDuration` | Number | Timer duration in minutes | RW | `HEATING`, `AC`, `DHW`
|
||||
`operationMode` | String | Operation mode the zone is currently in. One of `SCHEDULE` (follow smart schedule), `MANUAL` (override until ended manually), `TIMER` (override for a given time), `UNTIL_CHANGE` (active until next smart schedule block or until AWAY mode becomes active) | RW | `HEATING`, `AC`, `DHW`
|
||||
`batteryLowAlarm` | Switch | A control device in the Zone has a low battery (if applicable) | R | Any Zone
|
||||
`batteryLowAlarm` | Switch | A control device in the Zone has a low battery | R | Any Zone
|
||||
`openWindowDetected` | Switch | An open window has been detected in the Zone | R | Any Zone
|
||||
`light` | Switch | State (`ON`, `OFF`) of the control panel light (if applicable) | RW | `AC`
|
||||
`light` | Switch | State (`ON`, `OFF`) of the control panel light | RW | `AC`
|
||||
|
||||
You will see some of the above mentioned Channels only if your tado° device supports the respective function.
|
||||
|
||||
The `RW` items are used to either override the schedule or to return to it (if `hvacMode` is set to `SCHEDULE`).
|
||||
|
||||
|
||||