@@ -0,0 +1,142 @@
|
||||
# Studer
|
||||
|
||||
This extension adds support for the Studer protocol.
|
||||
|
||||
Studer Innotec, founded in 1987 by Roland Studer, is an ISO certified company that develops and manufactures inverters, inverter/chargers and MPPT solar charge controllers to communicate over the Modbus protocol entirely in Switzerland
|
||||
|
||||
For a list of certified products see this page: https://www.studer-innotec.com/
|
||||
|
||||
## Supported Things
|
||||
|
||||
This bundle adds the following thing type to the Modbus binding.
|
||||
Note, that the things will show up under the Modbus binding.
|
||||
|
||||
| Thing Type IDs | Description | Picture |
|
||||
|----------------|----------------------------------------------------------------------------------------------------------------------|-------------------------------------|
|
||||
| bsp | For BSP that offer a highly precise measuring for Xtender, VarioTrack and VarioString systems |  |
|
||||
| xtender | For the Xtender models for system capacities from 0.5kVA to 72kVA that allow for the optimal use of available energy |  |
|
||||
| variotrack | For the VarioTrack models of MPPT solar charge controllers for systems with solar PV capacity from 1 - 75kWp |  |
|
||||
| variostring | For the VarioString models of MPPT solar charge controllers for systems with solar PV capacity from 4 |  |
|
||||
|
||||
|
||||
## Thing Configuration
|
||||
|
||||
You need first to set up a Serial Modbus bridge according to the Modbus documentation.
|
||||
Things in this extension will use the selected bridge to connect to the device.
|
||||
|
||||
For defining a thing textually, you have to find out the start address of the model block and the length of it.
|
||||
While the length is usually fixed, the address is not.
|
||||
Please refer to your device's vendor documentation how model blocks are laid for your equipment.
|
||||
|
||||
The following parameters are valid for all thing types:
|
||||
|
||||
| Parameter | Type | Required | Default if omitted | Description |
|
||||
|-----------|---------|----------|-------------------------|----------------------------------------------------------------------------|
|
||||
| address | integer | yes | `first slave of device` | Address of slave |
|
||||
| refresh | integer | yes | 5 | Poll interval in seconds. Increase this if you encounter connection errors |
|
||||
|
||||
## Channels
|
||||
|
||||
The following Channels, and their associated channel types are shown below divided by device.
|
||||
|
||||
#### BSP
|
||||
|
||||
All channels read for a BSP device
|
||||
|
||||
| Channel | Type | Description |
|
||||
| ------------------ | ------------------------ | --------------------- |
|
||||
| power | Number:Power | Power |
|
||||
| batteryVoltage | Number:ElectricPotential | Battery voltage |
|
||||
| batteryCurrent | Number:ElectricCurrent | Battery current |
|
||||
| stateOfCharge | Number:Dimensionless | State of Charge |
|
||||
| batteryTemperature | Number:Temperature | Battery temperature |
|
||||
|
||||
#### Xtender
|
||||
|
||||
All channels read for a Xtender device
|
||||
|
||||
| Channel | Type | Description |
|
||||
| ----------------- | ------------------------ | ----------------------- |
|
||||
| inputVoltage | Number:ElectricPotential | Input voltage |
|
||||
| inputCurrent | Number:ElectricCurrent | Input current |
|
||||
| inputActivePower | Number:Power | Input active power |
|
||||
| inputFrequency | Number:Frequency | Input frequency |
|
||||
| outputVoltage | Number:ElectricPotential | Output voltage |
|
||||
| outputCurrent | Number:ElectricCurrent | Output current |
|
||||
| outputActivePower | Number:Power | Output active power |
|
||||
| outputFrequency | Number:Frequency | Output frequency |
|
||||
| operatingState | String | Operating state |
|
||||
| stateInverter | String | State of the inverter |
|
||||
|
||||
#### VarioTrack
|
||||
|
||||
All channels read for a VarioTrack device
|
||||
|
||||
| Channel | Type | Description |
|
||||
| -------------------- | ------------------------ | ----------------------------------------- |
|
||||
| modelVarioTrack | String | Model of VarioTrack |
|
||||
| voltagePVGenerator | Number:ElectricPotential | Voltage of the PV generator |
|
||||
| powerPVGenerator | Number:Power | Power of the PV generator |
|
||||
| productionCurrentDay | Number:Energy | Production in (kWh) for the current day |
|
||||
| batteryVoltage | Number:ElectricPotential | Battery voltage |
|
||||
| batteryCurrent | Number:ElectricCurrent | Battery current |
|
||||
| operatingMode | String | Operating mode |
|
||||
| stateVarioTrack | String | State of the VarioTrack |
|
||||
|
||||
#### VarioString
|
||||
|
||||
All channels read for a VarioString device
|
||||
|
||||
| Channel | Type | Description |
|
||||
| ----------------------- | ------------------------ | --------------------------------------------- |
|
||||
| PVVoltage | Number:ElectricPotential | PV voltage |
|
||||
| PVCurrent | Number:ElectricCurrent | PV current |
|
||||
| PVPower | Number:Power | PV power |
|
||||
| ProductionPVCurrentDay | Number:Energy | Production PV in (kWh) for the current day |
|
||||
| PV1Voltage | Number:ElectricPotential | PV1 voltage |
|
||||
| PV1Current | Number:ElectricCurrent | PV1 current |
|
||||
| PV1Power | Number:Power | PV1 power |
|
||||
| ProductionPV1CurrentDay | Number:Energy | Production PV1 in (kWh) for the current day |
|
||||
| PV2Voltage | Number:ElectricPotential | PV2 voltage |
|
||||
| PV2Current | Number:ElectricCurrent | PV2 current |
|
||||
| PV2Power | Number:Power | PV2 power |
|
||||
| ProductionPV2CurrentDay | Number:Energy | Production PV2 in (kWh) for the current day |
|
||||
| batteryVoltage | Number:ElectricPotential | Battery voltage |
|
||||
| batteryCurrent | Number:ElectricCurrent | Battery current |
|
||||
| PVMode | String | PV operating mode |
|
||||
| PV1Mode | String | PV1 operating mode |
|
||||
| PV2Mode | String | PV2 operating mode |
|
||||
| stateVarioString | String | State of the VarioString |
|
||||
|
||||
## Example
|
||||
|
||||
### Thing Configuration
|
||||
|
||||
```
|
||||
Bridge modbus:serial:bridge [port="/dev/ttyUSB0",baud=9600,dataBits=8,parity="even",stopBits="1.0",encoding="rtu"]
|
||||
Thing modbus:xtender:bridge:xtenderdevice "Xtender" (modbus:serial:modbusbridge) [ slaveAddress=10, refresh=5 ]
|
||||
```
|
||||
|
||||
Note: Make sure that refresh and slave address are numerical, without quotes.
|
||||
|
||||
### Item Configuration
|
||||
|
||||
```
|
||||
Number XtenderStuderThing_InputVoltage "Input Voltage [%.2f %unit%]"
|
||||
{channel="modbus:xtender:bridge:xtenderdevice:inputVoltage"}
|
||||
|
||||
Number XtenderStuderThing_InputCurrent "Input Current [%.2f %unit%]" {channel="modbus:xtender:bridge:xtenderdevice:inputCurrent"}
|
||||
|
||||
String XtenderStuderThing_StateInverter "State: [%s]" {channel="modbus:xtender:bridge:xtenderdevice:stateInverter"}
|
||||
```
|
||||
|
||||
### Sitemap Configuration
|
||||
|
||||
```
|
||||
Text item=XtenderStuderThing_InputVoltage
|
||||
Text item=XtenderStuderThing_InputCurrent
|
||||
Text item=XtenderStuderThing_StateInverter
|
||||
|
||||
Chart item=XtenderStuderThing_InputVoltage period=D refresh=600000
|
||||
Chart item=XtenderStuderThing_InputCurrent period=D refresh=30000
|
||||
```
|
||||
Reference in New Issue