added migrated 2.x add-ons
Signed-off-by: Kai Kreuzer <kai@openhab.org>
This commit is contained in:
82
bundles/org.openhab.binding.senechome/README.md
Normal file
82
bundles/org.openhab.binding.senechome/README.md
Normal file
@@ -0,0 +1,82 @@
|
||||
# Senec Home Binding
|
||||
|
||||
Binding to request status information from Senec Home Batteries to allow home automation decisions based on your current energy management.
|
||||
|
||||
If your power feed is limited by regulations for example, you can switch on devices if a limited rate was applied by your Senec Home device.
|
||||
In addition you can switch off devices if the power consumption is getting higher.
|
||||
|
||||
Examples: Lights, pool filters, wash machines, ...
|
||||
|
||||
## Supported Things
|
||||
|
||||
| Thing type id | Name |
|
||||
|----------------------|-----------------------------------------------|
|
||||
| senechome | Senec Home Lithium Battery, V2.0, V2.1 and V3 |
|
||||
|
||||
|
||||
## Thing Configuration
|
||||
|
||||
demo.things
|
||||
|
||||
```
|
||||
Thing senechome:senechome:pvbattery [ hostname="192.168.0.128", refreshInterval=60, limitationTresholdValue=70, limitationDuration=60 ]
|
||||
```
|
||||
|
||||
If the thing goes online then the connection to the web interface is successful.
|
||||
In case it is offline you should see an error message.
|
||||
The refresh interval is 15 seconds by default, but you can optionally provide your own value adding the `refreshInterval` key.
|
||||
|
||||
The property `limitationTresholdValue` is used as threshold for channel `powerLimitationState`. It is combined with property `limitationDuration` (seconds) to define a stable status for power limitation. Therefor use `powerLimitationState` to trigger Events (switches) based on your current power limitation.
|
||||
|
||||
## Channels
|
||||
|
||||
| Channel | Type | Description |
|
||||
|----------------------|---------|--------------------------------------------------------------------------|
|
||||
| powerLimitation | percent | How much is your pv generator limited (0% if not limited anyway) |
|
||||
| powerLimitationState | ON/OFF | Power limitation active (based on configuration) |
|
||||
| houseConsumption | watt | Current power consumption of your house/living |
|
||||
| energyProduction | watt | Energy generated by your pv / inverter |
|
||||
| batteryPower | watt | Energy processed by batterie itself, for example while charging |
|
||||
| batteryFuelCharge | percent | Fuel charge of your battery (0 - 100%) |
|
||||
| batteryState | | text describing current action of battery (e.g. CHARGING) |
|
||||
| gridPower | watt | Grid power level, negative for supply, positive values for drawing power |
|
||||
| gridPowerDraw | watt | absolute power level of power draw, zero while supplying |
|
||||
| gridPowerSupply | watt | absolute power level of power supply, zero while drawing |
|
||||
|
||||
## Items
|
||||
|
||||
Sample:
|
||||
|
||||
```
|
||||
Number SenecPowerLimitation "pv generator limit [%d %%]" <heating> { channel="senechome:senechome:pvbattery:powerLimitation" }
|
||||
Switch SenecPowerLimitationState "Power limitation active" <switch> { channel="senechome:senechome:pvbattery:powerLimitationState" }
|
||||
Number SenecHouseConsumption "Current power consumption [%d W]" <energy> { channel="senechome:senechome:pvbattery:houseConsumption" }
|
||||
Number SenecEnergyProduction "Energy generated by pv [%d W]" <energy> { channel="senechome:senechome:pvbattery:energyProduction" }
|
||||
Number SenecBatteryPower "Energy processed by battery [%d W]" <energy> { channel="senechome:senechome:pvbattery:batteryPower" }
|
||||
Number SenecBatteryFuelCharge "State of Charge [%d %%]" <batterylevel> { channel="senechome:senechome:pvbattery:batteryFuelCharge" }
|
||||
String SenecBatteryState "Current action [%s]" <text> { channel="senechome:senechome:pvbattery:batteryState" }
|
||||
Number SenecGridPower "Grid power level [%d W]" <energy> { channel="senechome:senechome:pvbattery:gridPower" }
|
||||
Number SenecGridPowerDraw "Power draw from grid [%d W]" <energy> { channel="senechome:senechome:pvbattery:gridPowerDraw" }
|
||||
Number SenecGridPowerSupply "Power supply to grid [%d W]" <energy> { channel="senechome:senechome:pvbattery:gridPowerSupply" }
|
||||
```
|
||||
|
||||
## Sitemap
|
||||
|
||||
Sample:
|
||||
|
||||
```
|
||||
Text label="Power Grid"{
|
||||
Frame label="Photovoltaik" {
|
||||
Default item=SenecPowerLimitation
|
||||
Default item=SenecPowerLimitationState
|
||||
Default item=SenecHouseConsumption
|
||||
Default item=SenecEnergyProduction
|
||||
Default item=SenecBatteryPower
|
||||
Default item=SenecBatteryFuelCharge
|
||||
Default item=SenecBatteryState
|
||||
Default item=SenecGridPower
|
||||
Default item=SenecGridPowerDraw
|
||||
Default item=SenecGridPowerSupply
|
||||
}
|
||||
}
|
||||
```
|
||||