[guntamatic] Added 'biosmart' and 'generic' thingtype, robustness improvements on control interface (#12146)
* * added 'biosmart' and 'generic' type. * robustness improvements on control interface Signed-off-by: Michael Weger <weger.michael@gmx.net>
This commit is contained in:
@@ -5,39 +5,41 @@ The Guntamatic Binding can be used to monitor and control [Guntamatic Heating Sy
|
||||
## Supported Things
|
||||
|
||||
The Guntamatic Binding was developed and tested using Guntamatic Biostar 15kW Pellets Heating System, running Firmware 3.2d.
|
||||
It should work for all other Guntamatic Heating Systems as well, that support the same web interface.
|
||||
It should work for all other Guntamatic Heating Systems as well, that support the same web interface (Pellets, WoodChips, EnergyGrain as well as Log Heating Systems).
|
||||
|
||||
## Things
|
||||
|
||||
Guntamatic Heating Systems supported as Thing Types:
|
||||
|
||||
| Name | Thing Type ID | Status |
|
||||
|---------------|---------------|-----------------------------------|
|
||||
| Biostar | `biostar` | tested via 15kW, firmware 3.2d |
|
||||
| Powerchip | `powerchip` | untested |
|
||||
| Powercorn | `powercorn` | untested |
|
||||
| Biocom | `biocom` | untested |
|
||||
| Pro | `pro` | untested |
|
||||
| Therm | `therm` | untested |
|
||||
| Name | Thing Type ID | Heating System Type | Binding Development Status |
|
||||
|---------------|---------------|----------------------|--------------------------------------------------|
|
||||
| Biostar | `biostar` | Pellets | tested via 15kW, firmware 3.2d, German & English |
|
||||
| Biosmart | `biosmart` | Logs | tested via 22kW, firmware 3.2f, German |
|
||||
| Powerchip | `powerchip` | WoodChips | tested via 100kW, firmware 3.2d, French |
|
||||
| Powercorn | `powercorn` | EnergyGrain | untested |
|
||||
| Biocom | `biocom` | Pellets | untested |
|
||||
| Pro | `pro` | Pellets or WoodChips | untested |
|
||||
| Therm | `therm` | Pellets | untested |
|
||||
| Generic | `generic` | - | use, if none from above |
|
||||
|
||||
### Thing Configuration
|
||||
|
||||
| Parameter | Description | Default |
|
||||
|------------------|-----------------------------------------------------------------------------|-----------------|
|
||||
| `hostname` | Hostname or IP address of the Guntamatic Heating System | |
|
||||
| `key` | Optional, but required to read protected parameters and to control the Guntamatic Heating System.<br/>The key needs to be requested from Guntamatic support, e.g. via https://www.guntamatic.com/en/contact/. | |
|
||||
| `refreshInterval` | Interval the Guntamatic Heating System is polled in seconds | `60` |
|
||||
| `encoding` | Code page used by the Guntamatic Heating System | `windows-1252` |
|
||||
| Parameter | Description | Default |
|
||||
|--------------------|-----------------------------------------------------------------------------|-----------------|
|
||||
| `hostname` | Hostname or IP address of the Guntamatic Heating System | |
|
||||
| `key` | Optional, but required to read protected parameters and to control the Guntamatic Heating System.<br/>The key needs to be requested from Guntamatic support, e.g. via https://www.guntamatic.com/en/contact/. | |
|
||||
| `refreshInterval` | Interval the Guntamatic Heating System is polled in seconds | `60` |
|
||||
| `encoding` | Code page used by the Guntamatic Heating System | `windows-1252` |
|
||||
|
||||
### Properties
|
||||
|
||||
| Property | Description |
|
||||
|---------------------|---------------------------------------------------------------|
|
||||
| `extraWwHeat` | Parameter used by `controlExtraWwHeat` channels |
|
||||
| `boilerApproval` | Parameter used by `controlBoilerApproval` channel |
|
||||
| `heatCircProgram` | Parameter used by `controlHeatCircProgram` channels |
|
||||
| `program` | Parameter used by `controlProgram` channel |
|
||||
| `wwHeat` | Parameter used by `controlWwHeat` channels |
|
||||
| Property | Description | Supported |
|
||||
|---------------------|---------------------------------------------------------------|---------------------------------------------------|
|
||||
| `extraWwHeat` | Parameter used by `controlExtraWwHeat` channels | all |
|
||||
| `boilerApproval` | Parameter used by `controlBoilerApproval` channel | Biostar, Powerchip, Powercorn, Biocom, Pro, Therm |
|
||||
| `heatCircProgram` | Parameter used by `controlHeatCircProgram` channels | all |
|
||||
| `program` | Parameter used by `controlProgram` channel | all |
|
||||
| `wwHeat` | Parameter used by `controlWwHeat` channels | all |
|
||||
|
||||
## Channels
|
||||
|
||||
@@ -45,10 +47,10 @@ Guntamatic Heating Systems supported as Thing Types:
|
||||
|
||||
The Guntamatic Heating System can be controlled using the following channels:
|
||||
|
||||
| Channel | Description | Type | Unit | Security Access Level | ReadOnly | Advanced |
|
||||
|-----------------------|-----------------------------------------------------------|-------|:---------:|:-------------------------:|:--------:|:--------:|
|
||||
| `controlBoilerApproval` | Set Boiler Approval (`AUTO`, `OFF`, `ON`) | `String` | | 🔐 W1 | R/W | true |
|
||||
| `controlProgram` | Set Program (`OFF`, `NORMAL`, `WARMWATER`, `MANUAL`) | `String` | | 🔐 W1 | R/W | false |
|
||||
| Channel | Description | Type | Unit | Security Access Level | ReadOnly | Advanced |
|
||||
|-----------------------|---------------------------------------------------------------------------|-------|:---------:|:-------------------------:|:--------:|:--------:|
|
||||
| `controlBoilerApproval` | Set Boiler Approval (`AUTO`, `OFF`, `ON`) | `String` | | 🔐 W1 | R/W | true |
|
||||
| `controlProgram` | Set Program (`OFF`, `NORMAL`, `WARMWATER`, `MANUAL`<sup id="a1">[1](#f1)</sup>) | `String` | | 🔐 W1 | R/W | false |
|
||||
| `controlHeatCircProgram0` | Set Heat Circle 0 Program (`OFF`, `NORMAL`, `HEAT`, `LOWER`) | `String` | | 🔐 W1 | R/W | true |
|
||||
| `controlHeatCircProgram1` | Set Heat Circle 1 Program (`OFF`, `NORMAL`, `HEAT`, `LOWER`) | `String` | | 🔐 W1 | R/W | true |
|
||||
| `controlHeatCircProgram2` | Set Heat Circle 2 Program (`OFF`, `NORMAL`, `HEAT`, `LOWER`) | `String` | | 🔐 W1 | R/W | true |
|
||||
@@ -58,18 +60,22 @@ The Guntamatic Heating System can be controlled using the following channels:
|
||||
| `controlHeatCircProgram6` | Set Heat Circle 6 Program (`OFF`, `NORMAL`, `HEAT`, `LOWER`) | `String` | | 🔐 W1 | R/W | true |
|
||||
| `controlHeatCircProgram7` | Set Heat Circle 7 Program (`OFF`, `NORMAL`, `HEAT`, `LOWER`) | `String` | | 🔐 W1 | R/W | true |
|
||||
| `controlHeatCircProgram8` | Set Heat Circle 8 Program (`OFF`, `NORMAL`, `HEAT`, `LOWER`) | `String` | | 🔐 W1 | R/W | true |
|
||||
| `controlWwHeat0` | Trigger Warm Water Circle 0 (`RECHARGE`) | `String` | | 🔐 W1 | R/W | true |
|
||||
| `controlWwHeat1` | Trigger Warm Water Circle 1 (`RECHARGE`) | `String` | | 🔐 W1 | R/W | true |
|
||||
| `controlWwHeat2` | Trigger Warm Water Circle 2 (`RECHARGE`) | `String` | | 🔐 W1 | R/W | true |
|
||||
| `controlExtraWwHeat0` | Trigger Extra Warm Water Circle 0 (`RECHARGE`) | `String` | | 🔐 W1 | R/W | true |
|
||||
| `controlExtraWwHeat1` | Trigger Extra Warm Water Circle 1 (`RECHARGE`) | `String` | | 🔐 W1 | R/W | true |
|
||||
| `controlExtraWwHeat2` | Trigger Extra Warm Water Circle 2 (`RECHARGE`) | `String` | | 🔐 W1 | R/W | true |
|
||||
| `controlWwHeat0` | Trigger Warm Water Circle 0 (`RECHARGE`) | `String` | | 🔐 W1 | R/W | true |
|
||||
| `controlWwHeat1` | Trigger Warm Water Circle 1 (`RECHARGE`) | `String` | | 🔐 W1 | R/W | true |
|
||||
| `controlWwHeat2` | Trigger Warm Water Circle 2 (`RECHARGE`) | `String` | | 🔐 W1 | R/W | true |
|
||||
| `controlExtraWwHeat0` | Trigger Extra Warm Water Circle 0 (`RECHARGE`) | `String` | | 🔐 W1 | R/W | true |
|
||||
| `controlExtraWwHeat1` | Trigger Extra Warm Water Circle 1 (`RECHARGE`) | `String` | | 🔐 W1 | R/W | true |
|
||||
| `controlExtraWwHeat2` | Trigger Extra Warm Water Circle 2 (`RECHARGE`) | `String` | | 🔐 W1 | R/W | true |
|
||||
|
||||
- <b id="f1">1)</b> ... `MANUAL` is supported by Biostar, Powerchip, Powercorn, Biocom, Pro as well as Therm only [↩](#a1)
|
||||
|
||||
#### Response of Control Channels
|
||||
|
||||
- `{"ack":"confirmation message"}` ... in case of success
|
||||
- `{"err":"error message"}` ... in case of error
|
||||
|
||||
The reaction of the Guntamatic Heating System can be monitored via the corresponding data channel. E.g. `programHc1` if you triggered `controlHeatCircProgram1`. The data channel gets updated with the next cyclic update (according to the `refreshInterval` configuration).
|
||||
|
||||
### Monitoring Channels
|
||||
|
||||
The Binding dynamically generates Channels, derived from the data provided from the actual Guntamatic Heating System.
|
||||
|
||||