[openwebnet] added channel "function" for Central Unit (#12483)
* added channel "function" for Central Unit Signed-off-by: Conte Andrea <andrea@conte.com>
This commit is contained in:
@@ -280,9 +280,9 @@ public class OpenWebNetThermoregulationHandler extends OpenWebNetThingHandler {
|
||||
super.handleMessage(msg);
|
||||
|
||||
if (isCentralUnit) {
|
||||
if (msg.isCommand()) {
|
||||
updateModeAndFunction((Thermoregulation) msg);
|
||||
}
|
||||
// there isn't a message used for setting OK for battery status so let's assume
|
||||
// it's OK and then change to KO if according message is received
|
||||
updateCUBatteryStatus(CU_BATTERY_OK);
|
||||
|
||||
if (msg.getWhat() == Thermoregulation.WhatThermo.REMOTE_CONTROL_DISABLED) {
|
||||
updateCURemoteControlStatus(CU_REMOTE_CONTROL_DISABLED);
|
||||
@@ -290,8 +290,21 @@ public class OpenWebNetThermoregulationHandler extends OpenWebNetThingHandler {
|
||||
updateCURemoteControlStatus(CU_REMOTE_CONTROL_ENABLED);
|
||||
} else if (msg.getWhat() == Thermoregulation.WhatThermo.BATTERY_KO) {
|
||||
updateCUBatteryStatus(CU_BATTERY_KO);
|
||||
} // must intercept all possibile WHATs (will be implemented soon)
|
||||
else if (msg.getWhat() == Thermoregulation.WhatThermo.AT_LEAST_ONE_PROBE_OFF) {
|
||||
logger.debug("handleMessage() Ignoring unsupported WHAT {}. Frame={}", msg.getWhat(), msg);
|
||||
} else if (msg.getWhat() == Thermoregulation.WhatThermo.AT_LEAST_ONE_PROBE_ANTIFREEZE) {
|
||||
logger.debug("handleMessage() Ignoring unsupported WHAT {}. Frame={}", msg.getWhat(), msg);
|
||||
} else if (msg.getWhat() == Thermoregulation.WhatThermo.AT_LEAST_ONE_PROBE_MANUAL) {
|
||||
logger.debug("handleMessage() Ignoring unsupported WHAT {}. Frame={}", msg.getWhat(), msg);
|
||||
} else if (msg.getWhat() == Thermoregulation.WhatThermo.FAILURE_DISCOVERED) {
|
||||
logger.debug("handleMessage() Ignoring unsupported WHAT {}. Frame={}", msg.getWhat(), msg);
|
||||
} else if (msg.getWhat() == Thermoregulation.WhatThermo.RELEASE_SENSOR_LOCAL_ADJUST) {
|
||||
logger.debug("handleMessage() Ignoring unsupported WHAT {}. Frame={}", msg.getWhat(), msg);
|
||||
} else {
|
||||
// check and eventually parse mode and function
|
||||
updateModeAndFunction((Thermoregulation) msg);
|
||||
}
|
||||
|
||||
return;
|
||||
}
|
||||
|
||||
@@ -439,9 +452,6 @@ public class OpenWebNetThermoregulationHandler extends OpenWebNetThingHandler {
|
||||
// TODO: 4 zone central -> zone #0 CAN be also a zone with its temp.. with 99-zones central no!
|
||||
// let's assume it's a 99 zone
|
||||
try {
|
||||
// there isn't a message used for setting OK for battery status so let's assume
|
||||
// it's OK and then change to KO if according message is received
|
||||
updateCUBatteryStatus(CU_BATTERY_OK);
|
||||
send(Thermoregulation.requestStatus("#0"));
|
||||
} catch (OWNException e) {
|
||||
logger.warn("refreshDevice() central unit returned OWNException {}", e.getMessage());
|
||||
|
||||
@@ -17,6 +17,7 @@
|
||||
<!-- read only -->
|
||||
<channel id="remoteControl" typeId="remoteControl"/>
|
||||
<channel id="batteryStatus" typeId="batteryStatus"/>
|
||||
<channel id="function" typeId="functionCentralUnit"/>
|
||||
<!-- read/write -->
|
||||
<channel id="setpointTemperature" typeId="setpointTemperature"/>
|
||||
<channel id="mode" typeId="modeCentralUnit"/>
|
||||
|
||||
@@ -66,6 +66,18 @@
|
||||
</state>
|
||||
</channel-type>
|
||||
|
||||
<channel-type id="functionCentralUnit">
|
||||
<item-type>String</item-type>
|
||||
<label>Thermo Function</label>
|
||||
<description>Thermo function of the Central Unit</description>
|
||||
<state readOnly="true">
|
||||
<options>
|
||||
<option value="HEATING">Heating</option>
|
||||
<option value="COOLING">Cooling</option>
|
||||
</options>
|
||||
</state>
|
||||
</channel-type>
|
||||
|
||||
<channel-type id="setpointTemperature">
|
||||
<item-type>Number:Temperature</item-type>
|
||||
<label>Setpoint Temperature</label>
|
||||
|
||||
Reference in New Issue