[openwebnet] Add support for Alarm (WHO=5) (#13694)
* [openwebnet] first changes for Alarm support * [openwebnet] added first version Alarm handler * [openwebnet] added ownIdTest for Alarm * [openwebnet] added things def for Alarm and discovery for alarm zone * [openwebnet] refreshDevice * [openwebnet] fix text formatting * [openwebnet] fixes * [openwebnet] added other alarm channels * [openwebnet] Alarm: codestyle and null checks * [openwebnet] updated Alarm examples in README and some cleanup * [openwebnet] changed zone channel from armed to state, cleaned README Signed-off-by: Massimo Valla <mvcode00@gmail.com>
This commit is contained in:
parent
590b2cb4f7
commit
7ce99b365a
|
@ -43,11 +43,13 @@ The following Things and OpenWebNet `WHOs` are supported:
|
|||
| Gateway Management | `13` | `bus_gateway` | Any IP gateway supporting OpenWebNet protocol should work | Successfully tested: F452, F453, F453AV,F454, F455, MyHOMEServer1, MyHOME_Screen10, MyHOME_Screen3,5, MH201, MH202, MH200N. Some connection stability issues/gateway resets reported with MH202 |
|
||||
| Lighting | `1` | `bus_on_off_switch`, `bus_dimmer` | BUS switches and dimmers | Successfully tested: F411/2, F411/4, F411U2, F422, F429. Some discovery issues reported with F429 (DALI Dimmers) |
|
||||
| Automation | `2` | `bus_automation` | BUS roller shutters, with position feedback and auto-calibration | Successfully tested: LN4672M2 |
|
||||
| Temperature Control | `4` | `bus_thermo_zone`, `bus_thermo_sensor`, `bus_thermo_cu` | Thermo zones management and temperature sensors (probes). | Successfully tested: H/LN4691, HS4692, KG4691; thermo sensors: L/N/NT4577 + 3455; Central Units (4 or 99 zones) are not fully supported yet. See [Channels - Thermo](#configuring-thermo) for more details |
|
||||
| Auxiliary (AUX) | `9` | `bus_aux` | AUX commands | Successfully tested: AUX configured for bulgrar-alarm unit 3486. **Only sending AUX commands is supported** |
|
||||
| Basic, CEN & CEN+ Scenarios | `0`, `15`, `25` | `bus_scenario_control`, `bus_cen_scenario_control`, `bus_cenplus_scenario_control` | Basic and CEN/CEN+ Scenarios events and virtual activation | Successfully tested: CEN/CEN+ scenario control: HC/HD/HS/L/N/NT4680 and basic scenario modules F420/IR3456 + L4680 (WHO=0) |
|
||||
| Dry Contact and IR Interfaces | `25` | `bus_dry_contact_ir` | Dry Contacts and IR Interfaces | Successfully tested: contact interfaces F428 and 3477; IR sensors: HC/HD/HS/L/N/NT4610 |
|
||||
| Energy Management | `18` | `bus_energy_meter` | Energy Management | Successfully tested: F520, F521. Partially tested: F522, F523 |
|
||||
| Temperature Control | `4` | `bus_thermo_zone`, `bus_thermo_sensor`, `bus_thermo_cu` | Thermo zones management and temperature sensors (probes) | Successfully tested: H/LN4691, HS4692, KG4691; thermo sensors: L/N/NT4577 + 3455; Central Units (4 or 99 zones) are not fully supported yet. See [Channels - Thermo](#configuring-thermo) for more details |
|
||||
| Alarm | `5` | `bus_alarm_system`, `bus_alarm_zone` | BUS Alarm system and zones | Successfully tested: Burglar-alarm Unit 3486 |
|
||||
| Auxiliary (AUX) | `9` | `bus_aux` | AUX commands | Successfully tested: AUX configured for Burglar-alarm Unit 3486. **Only sending AUX commands is supported** |
|
||||
| Basic, CEN & CEN+ Scenarios | `0`, `15`, `25` | `bus_scenario_control`, `bus_cen_scenario_control`, `bus_cenplus_scenario_control` | Basic and CEN/CEN+ Scenarios events and virtual activation | Successfully tested: CEN/CEN+ scenario control: HC/HD/HS/L/N/NT4680 and basic scenario modules F420/IR3456 + L4680 (WHO=0) |
|
||||
| Dry Contact and IR Interfaces | `25` | `bus_dry_contact_ir` | Dry Contacts and IR Interfaces | Successfully tested: contact interfaces F428 and 3477; IR sensors: HC/HD/HS/L/N/NT4610 |
|
||||
| Energy Management | `18` | `bus_energy_meter` | Energy Management | Successfully tested: F520, F521. Partially tested: F522, F523 |
|
||||
|
||||
|
||||
### For ZigBee (Radio)
|
||||
|
||||
|
@ -133,9 +135,10 @@ For any manually added device, you must configure:
|
|||
- scenario control module address `53` --> `where="53"`
|
||||
- CEN scenario A=`05`, PL=`12` --> `where="0512"`
|
||||
- CEN+ scenario `5`: add `2` before --> `where="25"`
|
||||
- Dry Contact or IR Interface `99`: add `3` before --> `where="399"`
|
||||
- Energy meter F520/F521 numbered `1`: add `5` before --> `where="51"`
|
||||
- Energy meter F522/F523 numbered `4` add `7` before and `#0` after --> `where="74#0"`
|
||||
- dry Contact or IR Interface `99`: add `3` before --> `where="399"`
|
||||
- energy meter F520/F521 numbered `1`: add `5` before --> `where="51"`
|
||||
- energy meter F522/F523 numbered `4`: add `7` before and `#0` after --> `where="74#0"`
|
||||
- alarm zone `2` --> `where="2"`
|
||||
- example for ZigBee devices: `where=765432101#9`. The ID of the device (ADDR part) is usually written in hexadecimal on the device itself, for example `ID 0074CBB1`: convert to decimal (`7654321`) and add `01#9` at the end to obtain `where=765432101#9`. For 2-unit switch devices (`zb_on_off_switch2u`), last part should be `00#9`.
|
||||
|
||||
|
||||
|
@ -157,83 +160,97 @@ Temperature sensors can be configured defining a `bus_thermo_sensor` Thing with
|
|||
|
||||
The (optional) Central Unit can be configured defining a `bus_themo_cu` Thing with the `where` configuration parameter (`OpenWebNet Address`) set to `where="0"`.
|
||||
|
||||
##### Central Unit integration missing points
|
||||
##### Thermo Central Unit integration missing points
|
||||
|
||||
- Read setPoint temperature and current mode
|
||||
- Holiday activation command (all zones)
|
||||
- Discovery
|
||||
|
||||
#### Configuring Auxiliary (AUX)
|
||||
#### Configuring Alarm and Auxiliary (AUX)
|
||||
|
||||
**NOTE** Receiving AUX messages originating from the BUS is not supported yet, only sending messages to the BUS is supported.
|
||||
**NOTE 1** Receiving AUX messages originating from the BUS is not supported yet, only sending messages to the BUS is supported
|
||||
|
||||
**NOTE 2** Alarm messages on BUS are not sent by MyHOMEServer1, therfore this gateway cannot be used to integrate the BTicino Alarm system
|
||||
|
||||
BUS Auxiliary commands (WHO=9) can be used to send on the BUS commands to control, for example, external devices or a BTicino Alarm system.
|
||||
|
||||
The BTicino Alarm system **cannot** be controlled directly via the OpenWebNet protocol: the only possibility is to use AUX commands and configure your Alarm Control Panel (Automations section) to execute some commands (e.g. Activate alarm) when it receives a particular AUX OpenWebNet command.
|
||||
Alarm Control Automations allow you to run an OpenWebNet command when a particular event occurs; in this case, the events are changes of state of the AUX device (WHO=9) and the command to be performed is a burglar alarm command (WHO=5).
|
||||
The BTicino Alarm system **cannot** be controlled directly via the OpenWebNet protocol: the only possibility is to use AUX commands and configure your Burglar-alarm Unit (`Automations` section) to execute some commands (e.g. Arm alarm) when it receives a particular AUX OpenWebNet command.
|
||||
Alarm Automations allow you to run an OpenWebNet command when a particular event occurs; in this case, the events are changes of state of the AUX device (WHO=9) and the command to be performed is a burglar alarm command (WHO=5).
|
||||
|
||||
To configure Alarm Control Automations go to the menu:
|
||||
To configure Alarm Automations go to the menu:
|
||||
|
||||
Antitheft -> Automations
|
||||
|
||||
##### Example configuration Automation 1: when AUX-1 goes OFF, then DISENGAGE all Zones
|
||||
##### Example configuration Automation 1: when AUX-4 goes ON, then ARM all zones
|
||||
|
||||
With this configuration when AUX `where=1` goes OFF, the Alarm will execute the automation and send command `*5*9##` to DISENGAGE all zones.
|
||||
With this configuration when AUX `where=4` goes ON, the Alarm will execute the automation and send command `*5*8##` to ARM all zones:
|
||||
|
||||
Name: Disengage all zones
|
||||
Event: command OPEN = *9*0*1##
|
||||
OPEN command to execute: *5*9##
|
||||
|
||||
##### Example configuration Automation 2: when AUX-2 goes ON, then ENGAGE active Zones
|
||||
|
||||
Name: Engage active zones
|
||||
Event: command OPEN = *9*1*2##
|
||||
Name: Arm all zones
|
||||
Event: command OPEN = *9*1*4##
|
||||
OPEN command to execute: *5*8##
|
||||
|
||||
##### Example configuration Automation 3: when AUX-4 goes ON, then ENGAGE Zones 1, 2, 3, 4
|
||||
##### Example configuration Automation 2: when AUX-4 goes OFF, then DISARM all zones
|
||||
|
||||
Name: Engage zones 1-4
|
||||
Event: command OPEN = *9*1*4##
|
||||
OPEN command to execute: *5*8#1234##
|
||||
Name: Disarm all zones
|
||||
Event: command OPEN = *9*0*4##
|
||||
OPEN command to execute: *5*9##
|
||||
|
||||
##### Example configuration Automation 3: when AUX-5 goes ON, then ARM zones 1, 3, 4
|
||||
|
||||
Name: Arm zones 1 3 4
|
||||
Event: command OPEN = *9*1*5##
|
||||
OPEN command to execute: *5*8#134##
|
||||
|
||||
## Channels
|
||||
|
||||
### Lighting, Automation, Power meter, Basic/CEN/CEN+ Scenario Events and Dry Contact / IR Interfaces channels
|
||||
### Lighting, Automation, Basic/CEN/CEN+ Scenario Events, Dry Contact / IR Interfaces, Power and Aux channels
|
||||
|
||||
| Channel Type ID (channel ID) | Applies to Thing Type IDs | Item Type | Description | Read/Write |
|
||||
|-----------------------------------------|---------------------------------------------------------------|---------------|-------------------------------------------------------------------------------------------------------------------------------------------------|:-----------:|
|
||||
| `switch` or `switch_01`/`02` for ZigBee | `bus_on_off_switch`, `zb_on_off_switch`, `zb_on_off_switch2u` | Switch | To switch the device `ON` and `OFF` | R/W |
|
||||
| `brightness` | `bus_dimmer`, `zb_dimmer` | Dimmer | To adjust the brightness value (Percent, `ON`, `OFF`) | R/W |
|
||||
| `shutter` | `bus_automation` | Rollershutter | To activate roller shutters (`UP`, `DOWN`, `STOP`, Percent - [see Shutter position](#shutter-position)) | R/W |
|
||||
| `button#X` | `bus_cen_scenario_control`, `bus_cenplus_scenario_control` | String | Trigger channel for CEN/CEN+ scenario events [see possible values](#scenario-channels) | R (TRIGGER) |
|
||||
| `sensor` | `bus_dry_contact_ir` | Switch | Indicates if a Dry Contact Interface is `ON`/`OFF`, or if a IR Sensor is detecting movement (`ON`), or not (`OFF`) | R |
|
||||
| `power` | `bus_energy_meter` | Number:Power | The current active power usage from Energy Meter | R |
|
||||
| Channel Type ID (channel ID) | Applies to Thing Type IDs | Item Type | Description | Read/Write |
|
||||
|-----------------------------------------|---------------------------------------------------------------|---------------|-----------------------------------------------------------------------------------------------------------------------|:-----------:|
|
||||
| `switch` or `switch_01`/`02` for ZigBee | `bus_on_off_switch`, `zb_on_off_switch`, `zb_on_off_switch2u` | Switch | To switch the device `ON` and `OFF` | R/W |
|
||||
| `brightness` | `bus_dimmer`, `zb_dimmer` | Dimmer | To adjust the brightness value (Percent, `ON`, `OFF`) | R/W |
|
||||
| `shutter` | `bus_automation` | Rollershutter | To activate roller shutters (`UP`, `DOWN`, `STOP`, Percent - [see Shutter position](#shutter-position)) | R/W |
|
||||
| `scenario` | `bus_scenario_control` | String | Trigger channel for Basic scenario events [see possible values](#scenario-channels) | R (TRIGGER) |
|
||||
| `button#X` | `bus_cen_scenario_control`, `bus_cenplus_scenario_control` | String | Trigger channel for CEN/CEN+ scenario events [see possible values](#scenario-channels) | R (TRIGGER) |
|
||||
| `sensor` | `bus_dry_contact_ir` | Switch | Indicates if a Dry Contact Interface is `ON`/`OFF`, or if a IR Sensor is detecting movement (`ON`), or not (`OFF`) | R |
|
||||
| `power` | `bus_energy_meter` | Number:Power | The current active power usage from Energy Meter | R |
|
||||
| `aux` | `bus_aux` | String | Possible commands: `ON`, `OFF`, `TOGGLE`, `STOP`, `UP`, `DOWN`, `ENABLED`, `DISABLED`, `RESET_GEN`, `RESET_BI`, `RESET_TRI`. Only `ON` and `OFF` are supported for now | R/W |
|
||||
| `scenario` | `bus_scenario_control` | String | Trigger channel for Basic scenario events [see possible values](#scenario-channels) | R (TRIGGER) |
|
||||
|
||||
|
||||
### Alarm channels
|
||||
|
||||
| Channel Type ID (channel ID) | Applies to Thing Type IDs | Item Type | Description | Read/Write |
|
||||
|------------------------------|----------------------------------------|-------------|-----------------------------------------------------------------------|:-----------:|
|
||||
| `state` | `bus_alarm_system`, `bus_alarm_zone` | Switch | Alarm system or zone is active (`ON`) or inactive (`OFF`) | R |
|
||||
| `network` | `bus_alarm_system` | Switch | Alarm system network state (`ON` = network ok, `OFF` = no network) | R |
|
||||
| `battery` | `bus_alarm_system` | String | Alarm system battery state (`OK`, `FAULT`, `UNLOADED`) | R |
|
||||
| `armed` | `bus_alarm_system` | Switch | Alarm system is armed (`ON`) or disarmed (`OFF`) | R |
|
||||
| `alarm` | `bus_alarm_zone` | String | Current alarm for the zone (`SILENT`, `INTRUSION`, `TAMPERING`, `ANTI_PANIC`) | R |
|
||||
|
||||
|
||||
### Thermo channels
|
||||
|
||||
**NOTE** Channels marked with Advanced=Y can be shown from Thing configuration > Channels tab > check `Show advanced`.
|
||||
**NOTE** Channels marked in the table with `Advanced = Y` can be shown on the UI from Thing configuration > Channels tab > check `Show advanced`.
|
||||
|
||||
| Channel Type ID (channel ID) | Applies to Thing Type IDs | Item Type | Description | Read/Write | Advanced |
|
||||
| ---------------------------- | -------------------------------------- | ------------------ | --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | :--------: | :------: |
|
||||
| `temperature` | `bus_thermo_zone`, `bus_thermo_sensor` | Number:Temperature | The zone currently sensed temperature | R | N |
|
||||
| `setpointTemperature` | `bus_thermo_zone`, `bus_thermo_cu` | Number:Temperature | The zone or Central Unit setpoint temperature | R/W | N |
|
||||
| `function` | `bus_thermo_zone`, `bus_thermo_cu` | String | The zone set thermo function (`COOLING`, `HEATING`, `GENERIC`) or the Central Unit thermo function (`COOLING`, `HEATING`) | R/W | N |
|
||||
| `mode` | `bus_thermo_zone`, `bus_thermo_cu` | String | The zone set mode (`MANUAL`, `PROTECTION`, `OFF`) or the Central Unit set mode ( `MANUAL`, `PROTECTION`, `OFF`, `WEEKLY`, `SCENARIO`) | R/W | N |
|
||||
| `speedFanCoil` | `bus_thermo_zone` | String | The zone fancoil speed: `AUTO`, `SPEED_1`, `SPEED_2`, `SPEED_3` | R/W | N |
|
||||
| Channel Type ID (channel ID) | Applies to Thing Type IDs | Item Type | Description | Read/Write | Advanced |
|
||||
| ---------------------------- | -------------------------------------- | ------------------ | ------------------------------------------------------------------------------------------------------------------------------------- | :--------: | :------: |
|
||||
| `temperature` | `bus_thermo_zone`, `bus_thermo_sensor` | Number:Temperature | The zone currently sensed temperature | R | N |
|
||||
| `setpointTemperature` | `bus_thermo_zone`, `bus_thermo_cu` | Number:Temperature | The zone or Central Unit setpoint temperature | R/W | N |
|
||||
| `function` | `bus_thermo_zone`, `bus_thermo_cu` | String | The zone set thermo function (`COOLING`, `HEATING`, `GENERIC`) or the Central Unit thermo function (`COOLING`, `HEATING`) | R/W | N |
|
||||
| `mode` | `bus_thermo_zone`, `bus_thermo_cu` | String | The zone set mode (`MANUAL`, `PROTECTION`, `OFF`) or the Central Unit set mode ( `MANUAL`, `PROTECTION`, `OFF`, `WEEKLY`, `SCENARIO`) | R/W | N |
|
||||
| `speedFanCoil` | `bus_thermo_zone` | String | The zone fancoil speed: `AUTO`, `SPEED_1`, `SPEED_2`, `SPEED_3` | R/W | N |
|
||||
| `actuators` | `bus_thermo_zone` | String | The zone actuator(s) status: `OFF`, `ON`, `OPENED`, `CLOSED` , `STOP`, `OFF_FAN_COIL`, `ON_SPEED_1`, `ON_SPEED_2`, `ON_SPEED_3`, `OFF_SPEED_1`, `OFF_SPEED_2`, `OFF_SPEED_3` | R | Y |
|
||||
| `heatingValves` | `bus_thermo_zone` | String | The zone heating valve(s) status: `OFF`, `ON`, `OPENED`, `CLOSED` , `STOP`, `OFF_FAN_COIL`, `ON_SPEED_1`, `ON_SPEED_2`, `ON_SPEED_3`, `OFF_SPEED_1`, `OFF_SPEED_2`, `OFF_SPEED_3` | R | Y |
|
||||
| `conditioningValves` | `bus_thermo_zone` | String | The zone conditioning valve(s) status: `OFF`, `ON`, `OPENED`, `CLOSED` , `STOP`, `OFF_FAN_COIL`, `ON_SPEED_1`, `ON_SPEED_2`, `ON_SPEED_3`, `OFF_SPEED_1`, `OFF_SPEED_2`, `OFF_SPEED_3` | R | Y |
|
||||
| `localOffset` | `bus_thermo_zone` | String | The zone local offset status: `OFF`, `PROTECTION`, `MINUS_3`, `MINUS_2` , `MINUS_1`, `NORMAL`, `PLUS_1`, `PLUS_2`, `PLUS_3` | R | Y |
|
||||
| `remoteControl` | `bus_thermo_cu` | String | The Central Unit Remote Control status: `ENABLED`, `DISABLED` | R | Y |
|
||||
| `batteryStatus` | `bus_thermo_cu` | String | The Central Unit Battery status: `OK`, `KO` | R | Y |
|
||||
| `weeklyProgram` | `bus_thermo_cu` | Number | The program number (`1`, `2`, `3`) when Central Unit mode is `WEEKLY` | R/W | N |
|
||||
| `scenarioProgram` | `bus_thermo_cu` | Number | The program number (`1`, `2`, ... , `16`) when Central Unit mode is `SCENARIO` | R/W | N |
|
||||
| `failureDiscovered` | `bus_thermo_cu` | Switch | Indicates if a Failure was discovered by the Central Unit: `ON`, `OFF` | R | Y |
|
||||
| `atLeastOneProbeOff` | `bus_thermo_cu` | Switch | Indicates if at least one probe is in OFF mode: `ON`, `OFF` | R | Y |
|
||||
| `atLeastOneProbeProtection` | `bus_thermo_cu` | Switch | Indicates if at least one probe is in PROTECTION mode: `ON`, `OFF` | R | Y |
|
||||
| `atLeastOneProbeManual` | `bus_thermo_cu` | Switch | Indicates if at least one probe is in MANUAL mode: `ON`, `OFF` | R | Y |
|
||||
| `heatingValves` | `bus_thermo_zone` | String | The zone heating valve(s) status: `OFF`, `ON`, `OPENED`, `CLOSED` , `STOP`, `OFF_FAN_COIL`, `ON_SPEED_1`, `ON_SPEED_2`, `ON_SPEED_3`, `OFF_SPEED_1`, `OFF_SPEED_2`, `OFF_SPEED_3` | R | Y |
|
||||
| `conditioningValves` | `bus_thermo_zone` | String | The zone conditioning valve(s) status: `OFF`, `ON`, `OPENED`, `CLOSED` , `STOP`, `OFF_FAN_COIL`, `ON_SPEED_1`, `ON_SPEED_2`, `ON_SPEED_3`, `OFF_SPEED_1`, `OFF_SPEED_2`, `OFF_SPEED_3` | R | Y |
|
||||
| `localOffset` | `bus_thermo_zone` | String | The zone local offset status: `OFF`, `PROTECTION`, `MINUS_3`, `MINUS_2` , `MINUS_1`, `NORMAL`, `PLUS_1`, `PLUS_2`, `PLUS_3` | R | Y |
|
||||
| `remoteControl` | `bus_thermo_cu` | String | The Central Unit Remote Control status: `ENABLED`, `DISABLED` | R | Y |
|
||||
| `batteryStatus` | `bus_thermo_cu` | String | The Central Unit Battery status: `OK`, `KO` | R | Y |
|
||||
| `weeklyProgram` | `bus_thermo_cu` | Number | The program number (`1`, `2`, `3`) when Central Unit mode is `WEEKLY` | R/W | N |
|
||||
| `scenarioProgram` | `bus_thermo_cu` | Number | The program number (`1`, `2`, ... , `16`) when Central Unit mode is `SCENARIO` | R/W | N |
|
||||
| `failureDiscovered` | `bus_thermo_cu` | Switch | Indicates if a Failure was discovered by the Central Unit: `ON`, `OFF` | R | Y |
|
||||
| `atLeastOneProbeOff` | `bus_thermo_cu` | Switch | Indicates if at least one probe is in OFF mode: `ON`, `OFF` | R | Y |
|
||||
| `atLeastOneProbeProtection` | `bus_thermo_cu` | Switch | Indicates if at least one probe is in PROTECTION mode: `ON`, `OFF` | R | Y |
|
||||
| `atLeastOneProbeManual` | `bus_thermo_cu` | Switch | Indicates if at least one probe is in MANUAL mode: `ON`, `OFF` | R | Y |
|
||||
|
||||
### Notes on channels
|
||||
|
||||
|
@ -282,7 +299,7 @@ In order to activate one of them you have to use two different channels:
|
|||
- with `mode` you can set the mode (`WEEKLY` or `SCENARIO`)
|
||||
- with `weeklyProgram` (if `WEEKLY` was set) or with `scenarioProgram` (if `SCENARIO` was set) you can set the program number
|
||||
|
||||
Example: if you want to activate SCENARIO #9 on the thermo Central Unit you have to set `mode` = `SCENARIO` and `scenarioProgram` = `9`.
|
||||
Example: if you want to activate SCENARIO number 9 on the thermo Central Unit you have to set `mode` = `SCENARIO` and `scenarioProgram` = `9`.
|
||||
|
||||
## Full Example
|
||||
|
||||
|
@ -309,7 +326,10 @@ Bridge openwebnet:bus_gateway:mybridge "MyHOMEServer1" [ host="192.168.1.35", pa
|
|||
bus_cenplus_scenario_control LR_CENplus_scenario "Living Room CEN+" [ where="212", buttons="1,5,18" ]
|
||||
bus_dry_contact_ir LR_IR_sensor "Living Room IR Sensor" [ where="399" ]
|
||||
|
||||
bus_aux Alarm_activation "Alarm activation" [ where="4" ]
|
||||
bus_aux Alarm_Control "Alarm control" [ where="4" ]
|
||||
|
||||
bus_alarm_system Alarm_Sys "Alarm System" [ where="0" ]
|
||||
bus_alarm_zone Alarm_Zone_3 "Alarm Zone 3" [ where="3" ]
|
||||
}
|
||||
```
|
||||
|
||||
|
@ -328,32 +348,32 @@ Bridge openwebnet:zb_gateway:myZBgateway [ serialPort="COM3" ] {
|
|||
|
||||
Example items linked to BUS devices:
|
||||
|
||||
NOTE: lights, blinds and zones (thermostat) can be handled from personal assistants (Google Home, Alexa). In the following example `Google Assistant` (`ga="..."`) and `HomeKit` (`homekit="..."`) were configured according to the [Google official documentation](https://www.openhab.org/docs/ecosystem/google-assistant) and [HomeKit official documentation](https://www.openhab.org/addons/integrations/homekit/)
|
||||
NOTE: lights, blinds and zones (thermostat) can be handled from personal assistants (Google Home, Alexa). In the following example `Google Assistant` (`ga="..."`) and `HomeKit` (`homekit="..."`) were configured according to the [Google official documentation](https://www.openhab.org/docs/ecosystem/google-assistant) and [HomeKit official documentation](https://www.openhab.org/addons/integrations/homekit/)
|
||||
|
||||
```
|
||||
Switch iLR_switch "Light" (gLivingRoom) { channel="openwebnet:bus_on_off_switch:mybridge:LR_switch:switch", ga="Light", homekit="Lighting" }
|
||||
Dimmer iLR_dimmer "Dimmer [%.0f %%]" (gLivingRoom) { channel="openwebnet:bus_dimmer:mybridge:LR_dimmer:brightness", ga="Light", homekit="Lighting" }
|
||||
Switch iLR_switch "Light" (gLivingRoom) { channel="openwebnet:bus_on_off_switch:mybridge:LR_switch:switch", ga="Light", homekit="Lighting" }
|
||||
Dimmer iLR_dimmer "Dimmer [%.0f %%]" (gLivingRoom) { channel="openwebnet:bus_dimmer:mybridge:LR_dimmer:brightness", ga="Light", homekit="Lighting" }
|
||||
|
||||
Rollershutter iLR_shutter "Shutter [%.0f %%]" (gShutters, gLivingRoom) { channel="openwebnet:bus_automation:mybridge:LR_shutter:shutter", ga="Blinds", homekit = "Window" }
|
||||
Rollershutter iLR_shutter "Shutter [%.0f %%]" (gShutters, gLivingRoom) { channel="openwebnet:bus_automation:mybridge:LR_shutter:shutter", ga="Blinds", homekit = "Window" }
|
||||
|
||||
Number:Power iCENTRAL_Ta "Power [%.0f %unit%]" { channel="openwebnet:bus_energy_meter:mybridge:CENTRAL_Ta:power" }
|
||||
Number:Power iCENTRAL_Tb "Power [%.0f %unit%]" { channel="openwebnet:bus_energy_meter:mybridge:CENTRAL_Tb:power" }
|
||||
Number:Power iCENTRAL_Ta "Power [%.0f %unit%]" { channel="openwebnet:bus_energy_meter:mybridge:CENTRAL_Ta:power" }
|
||||
Number:Power iCENTRAL_Tb "Power [%.0f %unit%]" { channel="openwebnet:bus_energy_meter:mybridge:CENTRAL_Tb:power" }
|
||||
|
||||
// 99 zones central unit
|
||||
Group gCentralUnit "Central Unit"
|
||||
Number:Temperature iCU_3550_manualset "Temperature" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:setpointTemperature", ga="thermostatTemperatureSetpoint" }
|
||||
String iCU_3550_remote "Remote Control" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:remoteControl" }
|
||||
String iCU_3550_battery "Battery Status" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:batteryStatus" }
|
||||
String iCU_3550_mode "Mode" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:mode" }
|
||||
Number iCU_3550_wpn "Weekly Program" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:weeklyProgram" }
|
||||
Number iCU_3550_spn "Scenario Program" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:scenarioProgram" }
|
||||
String iCU_3550_func "Function" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:function" }
|
||||
Switch iCU_3550_at1off "At least one probe in OFF" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:atLeastOneProbeOff" }
|
||||
Switch iCU_3550_at1pro "At least one probe in PROTECTION" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:atLeastOneProbeProtection" }
|
||||
Switch iCU_3550_at1man "At least one probe in MANUAL" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:atLeastOneProbeManual" }
|
||||
Switch iCU_3550_failure "Failure discovered" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:failureDiscovered" }
|
||||
// 99 zones thermo central unit
|
||||
Group gCentralUnit "Thermo Central Unit"
|
||||
Number:Temperature iCU_3550_manualset "Temperature" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:setpointTemperature", ga="thermostatTemperatureSetpoint" }
|
||||
String iCU_3550_remote "Remote Control" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:remoteControl" }
|
||||
String iCU_3550_battery "Battery Status" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:batteryStatus" }
|
||||
String iCU_3550_mode "Mode" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:mode" }
|
||||
Number iCU_3550_wpn "Weekly Program" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:weeklyProgram" }
|
||||
Number iCU_3550_spn "Scenario Program" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:scenarioProgram" }
|
||||
String iCU_3550_func "Function" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:function" }
|
||||
Switch iCU_3550_at1off "At least one probe in OFF" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:atLeastOneProbeOff" }
|
||||
Switch iCU_3550_at1pro "At least one probe in PROTECTION" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:atLeastOneProbeProtection" }
|
||||
Switch iCU_3550_at1man "At least one probe in MANUAL" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:atLeastOneProbeManual" }
|
||||
Switch iCU_3550_failure "Failure discovered" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:failureDiscovered" }
|
||||
|
||||
Group gLivingRoomZone "Living Room Zone" { ga="Thermostat" [ modes="auto=GENERIC,heat=HEATING,cool=COOLING", thermostatTemperatureRange="7,35", useFahrenheit=false ] }
|
||||
Group gLivingRoomZone "Living Room Zone" { ga="Thermostat" [ modes="auto=GENERIC,heat=HEATING,cool=COOLING", thermostatTemperatureRange="7,35", useFahrenheit=false ] }
|
||||
Number:Temperature iLR_zone_temp "Temperature [%.1f %unit%]" (gLivingRoomZone) { channel="openwebnet:bus_thermo_zone:mybridge:LR_zone:temperature", ga="thermostatTemperatureAmbient" }
|
||||
Number:Temperature iLR_zone_setTemp "SetPoint Temperature" (gLivingRoomZone) { channel="openwebnet:bus_thermo_zone:mybridge:LR_zone:setpointTemperature", ga="thermostatTemperatureSetpoint" }
|
||||
String iLR_zone_fanSpeed "FanSpeed" (gLivingRoomZone) { channel="openwebnet:bus_thermo_zone:mybridge:LR_zone:speedFanCoil" }
|
||||
|
@ -363,15 +383,21 @@ String iLR_zone_actuators "Actuators" (g
|
|||
String iLR_zone_hv "Heating valves" (gLivingRoomZone) { channel="openwebnet:bus_thermo_zone:mybridge:LR_zone:heatingValves" }
|
||||
String iLR_zone_cv "Conditioning valves" (gLivingRoomZone) { channel="openwebnet:bus_thermo_zone:mybridge:LR_zone:conditioningValves" }
|
||||
|
||||
Number:Temperature iEXT_temp "Temperature [%.1f %unit%]" (gExternal) { channel="openwebnet:bus_thermo_sensor:mybridge:EXT_tempsensor:temperature" }
|
||||
Number:Temperature iEXT_temp "Temperature [%.1f %unit%]" (gExternal) { channel="openwebnet:bus_thermo_sensor:mybridge:EXT_tempsensor:temperature" }
|
||||
|
||||
String iCENPlusProxyItem "CEN+ Proxy Item"
|
||||
|
||||
String iAlarm_activation "Alarm Activation" { channel="openwebnet:bus_aux:mybridge:Alarm_activation:aux"}
|
||||
|
||||
Switch iLR_IR_sensor "Sensor" { channel="openwebnet:bus_dry_contact_ir:mybridge:LR_IR_sensor:sensor" }
|
||||
|
||||
Switch iLR_IR_sensor "Sensor" { channel="openwebnet:bus_dry_contact_ir:mybridge:LR_IR_sensor:sensor" }
|
||||
|
||||
// alarm aux, alarm unit and a zone
|
||||
String iAlarm_Control "Alarm Control Arm/Disarm" (gAlarm) { channel="openwebnet:bus_aux:mybridge:Alarm_Control:aux"}
|
||||
Switch iAlarm_System_State "Alarm state" (gAlarm) { channel="openwebnet:bus_alarm_system:mybridge:Alarm_Sys:state" }
|
||||
Switch iAlarm_System_Armed "Alarm armed" (gAlarm) { channel="openwebnet:bus_alarm_system:mybridge:Alarm_Sys:armed" }
|
||||
Switch iAlarm_System_Network "Alarm network" (gAlarm) { channel="openwebnet:bus_alarm_system:mybridge:Alarm_Sys:network" }
|
||||
String iAlarm_System_Battery "Alarm battery" (gAlarm) { channel="openwebnet:bus_alarm_system:mybridge:Alarm_Sys:battery" }
|
||||
Switch iAlarm_Zone_3_State "Zone 3 state" (gAlarm) { channel="openwebnet:bus_alarm_zone:mybridge:Alarm_Zone_3:state" }
|
||||
String iAlarm_Zone_3_Alarm "Zone 3 alarm" (gAlarm) { channel="openwebnet:bus_alarm_zone:mybridge:Alarm_Zone_3:alarm" }
|
||||
```
|
||||
|
||||
Example items linked to OpenWebNet ZigBee devices:
|
||||
|
@ -419,10 +445,15 @@ sitemap openwebnet label="OpenWebNet Binding Example Sitemap"
|
|||
Switch item=iCENPlusProxyItem label="My CEN+ scenario" icon="movecontrol" mappings=[ON="Activate"]
|
||||
}
|
||||
|
||||
Frame label="Alarm activation via AUX command"
|
||||
Frame label="Alarm"
|
||||
{
|
||||
Switch item=iAlarm_activation icon="siren"
|
||||
|
||||
Switch item=iAlarm_System_State label="Alarm state"
|
||||
Switch item=iAlarm_Control label="Arm/Disarm alarm" icon="shield"
|
||||
Switch item=iAlarm_System_Armed label="Armed" icon="shield"
|
||||
Switch item=iAlarm_System_Network label="Network" icon="network"
|
||||
Default item=iAlarm_System_Battery label="Battery" icon="battery"
|
||||
Switch item=iAlarm_Zone_3_State label="Zone 3 state"
|
||||
Default item=iAlarm_Zone_3_Alarm label="Zone 3 alarm" icon="siren"
|
||||
}
|
||||
}
|
||||
```
|
||||
|
@ -467,6 +498,7 @@ when
|
|||
then
|
||||
sendCommand(iLR_dimmer, DECREASE)
|
||||
end
|
||||
|
||||
```
|
||||
|
||||
## Notes
|
||||
|
@ -486,5 +518,6 @@ Special thanks for helping on testing this binding go to:
|
|||
[@gabriele.daltoe](https://community.openhab.org/u/gabriele.daltoe),
|
||||
[@feodor](https://community.openhab.org/u/feodor),
|
||||
[@aconte80](https://community.openhab.org/u/aconte80),
|
||||
[@rubenfuser](https://community.openhab.org/u/rubenfuser)
|
||||
[@rubenfuser](https://community.openhab.org/u/rubenfuser),
|
||||
[@stamate_viorel](https://community.openhab.org/u/stamate_viorel)
|
||||
and many others at the fantastic openHAB community!
|
||||
|
|
|
@ -23,7 +23,7 @@
|
|||
<dependency>
|
||||
<groupId>io.github.openwebnet4j</groupId>
|
||||
<artifactId>openwebnet4j</artifactId>
|
||||
<version>0.9.0</version>
|
||||
<version>0.9.1</version>
|
||||
<scope>compile</scope>
|
||||
</dependency>
|
||||
|
||||
|
|
|
@ -22,7 +22,8 @@ import org.eclipse.jdt.annotation.NonNullByDefault;
|
|||
import org.openhab.core.thing.ThingTypeUID;
|
||||
|
||||
/**
|
||||
* The {@link OpenWebNetBindingConstants} class defines common constants, which are used across the whole binding.
|
||||
* The {@link OpenWebNetBindingConstants} class defines common constants, which
|
||||
* are used across the whole binding.
|
||||
*
|
||||
* @author Massimo Valla - Initial contribution, updates
|
||||
* @author Gilberto Cocchi - Thermoregulation
|
||||
|
@ -72,6 +73,10 @@ public class OpenWebNetBindingConstants {
|
|||
public static final String THING_LABEL_BUS_CENPLUS_SCENARIO_CONTROL = "CEN+ Scenario Control";
|
||||
public static final ThingTypeUID THING_TYPE_BUS_SCENARIO = new ThingTypeUID(BINDING_ID, "bus_scenario_control");
|
||||
public static final String THING_LABEL_BUS_SCENARIO = "Scenario Control";
|
||||
public static final ThingTypeUID THING_TYPE_BUS_ALARM_SYSTEM = new ThingTypeUID(BINDING_ID, "bus_alarm_system");
|
||||
public static final String THING_LABEL_BUS_ALARM_SYSTEM = "Alarm System";
|
||||
public static final ThingTypeUID THING_TYPE_BUS_ALARM_ZONE = new ThingTypeUID(BINDING_ID, "bus_alarm_zone");
|
||||
public static final String THING_LABEL_BUS_ALARM_ZONE = "Alarm Zone";
|
||||
public static final ThingTypeUID THING_TYPE_BUS_AUX = new ThingTypeUID(BINDING_ID, "bus_aux");
|
||||
public static final String THING_LABEL_BUS_AUX = "Auxiliary";
|
||||
// ZIGBEE
|
||||
|
@ -107,12 +112,16 @@ public class OpenWebNetBindingConstants {
|
|||
public static final Set<ThingTypeUID> SCENARIO_BASIC_SUPPORTED_THING_TYPES = Set.of(THING_TYPE_BUS_SCENARIO);
|
||||
// ## Aux
|
||||
public static final Set<ThingTypeUID> AUX_SUPPORTED_THING_TYPES = Set.of(THING_TYPE_BUS_AUX);
|
||||
// ## Alarm
|
||||
public static final Set<ThingTypeUID> ALARM_SUPPORTED_THING_TYPES = Set.of(THING_TYPE_BUS_ALARM_SYSTEM,
|
||||
THING_TYPE_BUS_ALARM_ZONE);
|
||||
|
||||
// ## Groups
|
||||
public static final Set<ThingTypeUID> DEVICE_SUPPORTED_THING_TYPES = Stream
|
||||
.of(LIGHTING_SUPPORTED_THING_TYPES, AUTOMATION_SUPPORTED_THING_TYPES,
|
||||
THERMOREGULATION_SUPPORTED_THING_TYPES, ENERGY_MANAGEMENT_SUPPORTED_THING_TYPES,
|
||||
SCENARIO_SUPPORTED_THING_TYPES, SCENARIO_BASIC_SUPPORTED_THING_TYPES, AUX_SUPPORTED_THING_TYPES,
|
||||
GENERIC_SUPPORTED_THING_TYPES)
|
||||
ALARM_SUPPORTED_THING_TYPES, GENERIC_SUPPORTED_THING_TYPES)
|
||||
.flatMap(Collection::stream).collect(Collectors.toCollection(HashSet::new));
|
||||
public static final Set<ThingTypeUID> BRIDGE_SUPPORTED_THING_TYPES = Set.of(THING_TYPE_ZB_GATEWAY,
|
||||
THING_TYPE_BUS_GATEWAY);
|
||||
|
@ -157,6 +166,13 @@ public class OpenWebNetBindingConstants {
|
|||
public static final String CHANNEL_SCENARIO = "scenario";
|
||||
// aux
|
||||
public static final String CHANNEL_AUX = "aux";
|
||||
// alarm
|
||||
public static final String CHANNEL_ALARM_SYSTEM_STATE = "state";
|
||||
public static final String CHANNEL_ALARM_SYSTEM_ARMED = "armed";
|
||||
public static final String CHANNEL_ALARM_SYSTEM_NETWORK = "network";
|
||||
public static final String CHANNEL_ALARM_SYSTEM_BATTERY = "battery";
|
||||
public static final String CHANNEL_ALARM_ZONE_STATE = "state";
|
||||
public static final String CHANNEL_ALARM_ZONE_ALARM_STATE = "alarm";
|
||||
|
||||
// devices config properties
|
||||
public static final String CONFIG_PROPERTY_WHERE = "where";
|
||||
|
|
|
@ -16,6 +16,7 @@ import static org.openhab.binding.openwebnet.internal.OpenWebNetBindingConstants
|
|||
|
||||
import org.eclipse.jdt.annotation.NonNullByDefault;
|
||||
import org.eclipse.jdt.annotation.Nullable;
|
||||
import org.openhab.binding.openwebnet.internal.handler.OpenWebNetAlarmHandler;
|
||||
import org.openhab.binding.openwebnet.internal.handler.OpenWebNetAutomationHandler;
|
||||
import org.openhab.binding.openwebnet.internal.handler.OpenWebNetAuxiliaryHandler;
|
||||
import org.openhab.binding.openwebnet.internal.handler.OpenWebNetBridgeHandler;
|
||||
|
@ -83,6 +84,9 @@ public class OpenWebNetHandlerFactory extends BaseThingHandlerFactory {
|
|||
} else if (OpenWebNetScenarioBasicHandler.SUPPORTED_THING_TYPES.contains(thing.getThingTypeUID())) {
|
||||
logger.debug("Creating NEW BASIC SCENARIO Handler");
|
||||
return new OpenWebNetScenarioBasicHandler(thing);
|
||||
} else if (OpenWebNetAlarmHandler.SUPPORTED_THING_TYPES.contains(thing.getThingTypeUID())) {
|
||||
logger.debug("creating NEW ALARM Handler");
|
||||
return new OpenWebNetAlarmHandler(thing);
|
||||
}
|
||||
logger.warn("ThingType {} is not supported by this binding", thing.getThingTypeUID());
|
||||
return null;
|
||||
|
|
|
@ -31,6 +31,7 @@ import org.openhab.core.thing.binding.ThingHandlerService;
|
|||
import org.openwebnet4j.OpenDeviceType;
|
||||
import org.openwebnet4j.message.BaseOpenMessage;
|
||||
import org.openwebnet4j.message.Where;
|
||||
import org.openwebnet4j.message.WhereAlarm;
|
||||
import org.openwebnet4j.message.WhereThermo;
|
||||
import org.openwebnet4j.message.WhereZigBee;
|
||||
import org.openwebnet4j.message.Who;
|
||||
|
@ -95,7 +96,8 @@ public class OpenWebNetDeviceDiscoveryService extends AbstractDiscoveryService
|
|||
* @param message the OWN message received that identified the device
|
||||
* (optional)
|
||||
*/
|
||||
public void newDiscoveryResult(Where where, OpenDeviceType deviceType, @Nullable BaseOpenMessage baseMsg) {
|
||||
public void newDiscoveryResult(@Nullable Where where, OpenDeviceType deviceType,
|
||||
@Nullable BaseOpenMessage baseMsg) {
|
||||
logger.debug("newDiscoveryResult() WHERE={}, deviceType={}", where, deviceType);
|
||||
ThingTypeUID thingTypeUID = OpenWebNetBindingConstants.THING_TYPE_GENERIC_DEVICE; // generic device
|
||||
String thingLabel = OpenWebNetBindingConstants.THING_LABEL_GENERIC_DEVICE;
|
||||
|
@ -189,6 +191,18 @@ public class OpenWebNetDeviceDiscoveryService extends AbstractDiscoveryService
|
|||
deviceWho = Who.AUX;
|
||||
break;
|
||||
}
|
||||
case SCS_ALARM_CENTRAL_UNIT: {
|
||||
thingTypeUID = OpenWebNetBindingConstants.THING_TYPE_BUS_ALARM_SYSTEM;
|
||||
thingLabel = OpenWebNetBindingConstants.THING_LABEL_BUS_ALARM_SYSTEM;
|
||||
deviceWho = Who.BURGLAR_ALARM;
|
||||
break;
|
||||
}
|
||||
case SCS_ALARM_ZONE: {
|
||||
thingTypeUID = OpenWebNetBindingConstants.THING_TYPE_BUS_ALARM_ZONE;
|
||||
thingLabel = OpenWebNetBindingConstants.THING_LABEL_BUS_ALARM_ZONE;
|
||||
deviceWho = Who.BURGLAR_ALARM;
|
||||
break;
|
||||
}
|
||||
default:
|
||||
logger.warn("Device type {} is not supported, default to GENERIC device (WHERE={})", deviceType, where);
|
||||
if (where instanceof WhereZigBee) {
|
||||
|
@ -198,35 +212,46 @@ public class OpenWebNetDeviceDiscoveryService extends AbstractDiscoveryService
|
|||
deviceWho = baseMsg.getWho();
|
||||
}
|
||||
}
|
||||
Where w;
|
||||
if (where != null) {
|
||||
w = where;
|
||||
} else if (OpenWebNetBindingConstants.THING_TYPE_BUS_ALARM_SYSTEM.equals(thingTypeUID)) {
|
||||
w = new WhereAlarm("0");
|
||||
} else {
|
||||
logger.debug("ignoring newDiscoveryResult with null where: {}", baseMsg);
|
||||
return;
|
||||
}
|
||||
|
||||
String ownId = bridgeHandler.ownIdFromWhoWhere(deviceWho, where);
|
||||
String ownId = bridgeHandler.ownIdFromWhoWhere(deviceWho, w);
|
||||
if (OpenWebNetBindingConstants.THING_TYPE_BUS_ON_OFF_SWITCH.equals(thingTypeUID)) {
|
||||
if (bridgeHandler.getRegisteredDevice(ownId) != null) {
|
||||
logger.debug("dimmer/switch with WHERE={} already registered, skipping this discovery result", where);
|
||||
logger.debug("dimmer/switch with WHERE={} already registered, skipping this discovery result", w);
|
||||
return;
|
||||
}
|
||||
}
|
||||
|
||||
String tId = bridgeHandler.thingIdFromWhere(where);
|
||||
String tId = bridgeHandler.thingIdFromWhere(w);
|
||||
ThingUID thingUID = new ThingUID(thingTypeUID, bridgeUID, tId);
|
||||
|
||||
DiscoveryResult discoveryResult = null;
|
||||
|
||||
String whereConfig = where.value();
|
||||
String whereConfig = w.value();
|
||||
|
||||
// remove # from discovered thermo zone or central unit
|
||||
// remove # from discovered thermo zone/central unit or alarm zone
|
||||
if (OpenWebNetBindingConstants.THING_TYPE_BUS_THERMO_ZONE.equals(thingTypeUID)
|
||||
|| OpenWebNetBindingConstants.THING_TYPE_BUS_THERMO_CU.equals(thingTypeUID)) {
|
||||
whereConfig = "" + ((WhereThermo) where).getZone();
|
||||
} else if (OpenWebNetBindingConstants.THING_TYPE_BUS_ALARM_ZONE.equals(thingTypeUID)) {
|
||||
whereConfig = "" + ((WhereAlarm) where).getZone();
|
||||
}
|
||||
if (where instanceof WhereZigBee && WhereZigBee.UNIT_02.equals(((WhereZigBee) where).getUnit())) {
|
||||
if (w instanceof WhereZigBee && WhereZigBee.UNIT_02.equals(((WhereZigBee) where).getUnit())) {
|
||||
logger.debug("UNIT=02 found (WHERE={}) -> will remove previous result if exists", where);
|
||||
thingRemoved(thingUID); // remove previously discovered thing
|
||||
// re-create thingUID with new type
|
||||
thingTypeUID = OpenWebNetBindingConstants.THING_TYPE_ZB_ON_OFF_SWITCH_2UNITS;
|
||||
thingLabel = OpenWebNetBindingConstants.THING_LABEL_ZB_ON_OFF_SWITCH_2UNITS;
|
||||
thingUID = new ThingUID(thingTypeUID, bridgeUID, tId);
|
||||
whereConfig = ((WhereZigBee) where).valueWithUnit(WhereZigBee.UNIT_ALL); // replace unit '02' with '00'
|
||||
whereConfig = ((WhereZigBee) w).valueWithUnit(WhereZigBee.UNIT_ALL); // replace unit '02' with '00'
|
||||
logger.debug("UNIT=02, switching type from {} to {}",
|
||||
OpenWebNetBindingConstants.THING_TYPE_ZB_ON_OFF_SWITCH,
|
||||
OpenWebNetBindingConstants.THING_TYPE_ZB_ON_OFF_SWITCH_2UNITS);
|
||||
|
|
|
@ -0,0 +1,233 @@
|
|||
/**
|
||||
* Copyright (c) 2010-2022 Contributors to the openHAB project
|
||||
*
|
||||
* See the NOTICE file(s) distributed with this work for additional
|
||||
* information.
|
||||
*
|
||||
* This program and the accompanying materials are made available under the
|
||||
* terms of the Eclipse Public License 2.0 which is available at
|
||||
* http://www.eclipse.org/legal/epl-2.0
|
||||
*
|
||||
* SPDX-License-Identifier: EPL-2.0
|
||||
*/
|
||||
package org.openhab.binding.openwebnet.internal.handler;
|
||||
|
||||
import static org.openhab.binding.openwebnet.internal.OpenWebNetBindingConstants.*;
|
||||
|
||||
import java.util.Set;
|
||||
|
||||
import org.eclipse.jdt.annotation.NonNullByDefault;
|
||||
import org.openhab.binding.openwebnet.internal.OpenWebNetBindingConstants;
|
||||
import org.openhab.core.library.types.OnOffType;
|
||||
import org.openhab.core.library.types.StringType;
|
||||
import org.openhab.core.thing.ChannelUID;
|
||||
import org.openhab.core.thing.Thing;
|
||||
import org.openhab.core.thing.ThingStatus;
|
||||
import org.openhab.core.thing.ThingStatusDetail;
|
||||
import org.openhab.core.thing.ThingTypeUID;
|
||||
import org.openhab.core.types.Command;
|
||||
import org.openwebnet4j.communication.OWNException;
|
||||
import org.openwebnet4j.message.Alarm;
|
||||
import org.openwebnet4j.message.Alarm.WhatAlarm;
|
||||
import org.openwebnet4j.message.BaseOpenMessage;
|
||||
import org.openwebnet4j.message.Where;
|
||||
import org.openwebnet4j.message.WhereAlarm;
|
||||
import org.openwebnet4j.message.Who;
|
||||
import org.slf4j.Logger;
|
||||
import org.slf4j.LoggerFactory;
|
||||
|
||||
/**
|
||||
* The {@link OpenWebNetAlarmHandler} is responsible for handling
|
||||
* commands/messages for Alarm system and zones. It extends the abstract
|
||||
* {@link OpenWebNetThingHandler}.
|
||||
*
|
||||
* @author Massimo Valla - Initial contribution
|
||||
*/
|
||||
@NonNullByDefault
|
||||
public class OpenWebNetAlarmHandler extends OpenWebNetThingHandler {
|
||||
|
||||
private final Logger logger = LoggerFactory.getLogger(OpenWebNetAlarmHandler.class);
|
||||
|
||||
public static final Set<ThingTypeUID> SUPPORTED_THING_TYPES = OpenWebNetBindingConstants.ALARM_SUPPORTED_THING_TYPES;
|
||||
|
||||
private static long lastAllDevicesRefreshTS = 0; // ts when last all device refresh was sent for this handler
|
||||
|
||||
private static final String BATTERY_OK = "OK";
|
||||
private static final String BATTERY_FAULT = "FAULT";
|
||||
private static final String BATTERY_UNLOADED = "UNLOADED";
|
||||
|
||||
private static final String SILENT = "SILENT";
|
||||
private static final String INTRUSION = "INTRUSION";
|
||||
private static final String ANTI_PANIC = "ANTI_PANIC";
|
||||
private static final String TAMPERING = "TAMPERING";
|
||||
|
||||
public OpenWebNetAlarmHandler(Thing thing) {
|
||||
super(thing);
|
||||
}
|
||||
|
||||
@Override
|
||||
protected void handleChannelCommand(ChannelUID channel, Command command) {
|
||||
logger.warn("Alarm.handleChannelCommand() Read only channel, unsupported command {}", command);
|
||||
}
|
||||
|
||||
@Override
|
||||
protected void requestChannelState(ChannelUID channel) {
|
||||
super.requestChannelState(channel);
|
||||
Where w = deviceWhere;
|
||||
ThingTypeUID thingType = thing.getThingTypeUID();
|
||||
try {
|
||||
if (THING_TYPE_BUS_ALARM_SYSTEM.equals(thingType)) {
|
||||
send(Alarm.requestSystemStatus());
|
||||
lastAllDevicesRefreshTS = System.currentTimeMillis();
|
||||
} else {
|
||||
if (w != null) {
|
||||
send(Alarm.requestZoneStatus("#" + w.value()));
|
||||
} else {
|
||||
logger.debug("null where while requesting state for channel {}", channel);
|
||||
}
|
||||
}
|
||||
} catch (OWNException e) {
|
||||
logger.debug("Exception while requesting state for channel {}: {} ", channel, e.getMessage());
|
||||
updateStatus(ThingStatus.OFFLINE, ThingStatusDetail.COMMUNICATION_ERROR, e.getMessage());
|
||||
}
|
||||
}
|
||||
|
||||
@Override
|
||||
protected long getRefreshAllLastTS() {
|
||||
return lastAllDevicesRefreshTS;
|
||||
};
|
||||
|
||||
@Override
|
||||
protected void refreshDevice(boolean refreshAll) {
|
||||
if (refreshAll) {
|
||||
logger.debug("--- refreshDevice() : refreshing all via ALARM CENTRAL UNIT... ({})", thing.getUID());
|
||||
try {
|
||||
send(Alarm.requestSystemStatus());
|
||||
lastAllDevicesRefreshTS = System.currentTimeMillis();
|
||||
} catch (OWNException e) {
|
||||
logger.warn("Excpetion while requesting alarm system status: {}", e.getMessage());
|
||||
}
|
||||
} else {
|
||||
logger.debug("--- refreshDevice() : refreshing SINGLE... ({})", thing.getUID());
|
||||
requestChannelState(new ChannelUID(thing.getUID(), CHANNEL_ALARM_SYSTEM_STATE));
|
||||
}
|
||||
}
|
||||
|
||||
@Override
|
||||
protected void handleMessage(BaseOpenMessage msg) {
|
||||
logger.debug("handleMessage({}) for thing: {}", msg, thing.getUID());
|
||||
super.handleMessage(msg);
|
||||
ThingTypeUID thingType = thing.getThingTypeUID();
|
||||
if (THING_TYPE_BUS_ALARM_SYSTEM.equals(thingType)) {
|
||||
updateSystem((Alarm) msg);
|
||||
} else {
|
||||
updateZone((Alarm) msg);
|
||||
}
|
||||
}
|
||||
|
||||
private void updateSystem(Alarm msg) {
|
||||
WhatAlarm w = (WhatAlarm) msg.getWhat();
|
||||
if (w == null) {
|
||||
logger.debug("Alarm.updateSystem() WHAT is null. Frame={}", msg);
|
||||
return;
|
||||
}
|
||||
switch (w) {
|
||||
case SYSTEM_ACTIVE:
|
||||
case SYSTEM_INACTIVE:
|
||||
case SYSTEM_MAINTENANCE:
|
||||
updateAlarmSystemState(w);
|
||||
break;
|
||||
case SYSTEM_DISENGAGED:
|
||||
case SYSTEM_ENGAGED:
|
||||
updateAlarmSystemArmed(w);
|
||||
break;
|
||||
case SYSTEM_BATTERY_FAULT:
|
||||
case SYSTEM_BATTERY_OK:
|
||||
case SYSTEM_BATTERY_UNLOADED:
|
||||
updateBatteryState(w);
|
||||
break;
|
||||
case SYSTEM_NETWORK_ERROR:
|
||||
case SYSTEM_NETWORK_OK:
|
||||
updateNetworkState(w);
|
||||
break;
|
||||
case START_PROGRAMMING:
|
||||
case STOP_PROGRAMMING:
|
||||
case DELAY_END:
|
||||
case NO_CONNECTION_TO_DEVICE:
|
||||
default:
|
||||
logger.debug("Alarm.updateSystem() Ignoring unsupported WHAT {}. Frame={}", msg.getWhat(), msg);
|
||||
}
|
||||
}
|
||||
|
||||
private void updateAlarmSystemState(WhatAlarm w) {
|
||||
updateState(CHANNEL_ALARM_SYSTEM_STATE, OnOffType.from(w == Alarm.WhatAlarm.SYSTEM_ACTIVE));
|
||||
}
|
||||
|
||||
private void updateAlarmSystemArmed(WhatAlarm w) {
|
||||
updateState(CHANNEL_ALARM_SYSTEM_ARMED, OnOffType.from(w == Alarm.WhatAlarm.SYSTEM_ENGAGED));
|
||||
}
|
||||
|
||||
private void updateNetworkState(WhatAlarm w) {
|
||||
updateState(CHANNEL_ALARM_SYSTEM_NETWORK, OnOffType.from(w == Alarm.WhatAlarm.SYSTEM_NETWORK_OK));
|
||||
}
|
||||
|
||||
private void updateBatteryState(WhatAlarm w) {
|
||||
if (w == Alarm.WhatAlarm.SYSTEM_BATTERY_OK) {
|
||||
updateState(CHANNEL_ALARM_SYSTEM_BATTERY, new StringType(BATTERY_OK));
|
||||
} else if (w == Alarm.WhatAlarm.SYSTEM_BATTERY_UNLOADED) {
|
||||
updateState(CHANNEL_ALARM_SYSTEM_BATTERY, new StringType(BATTERY_UNLOADED));
|
||||
} else {
|
||||
updateState(CHANNEL_ALARM_SYSTEM_BATTERY, new StringType(BATTERY_FAULT));
|
||||
}
|
||||
}
|
||||
|
||||
private void updateZone(Alarm msg) {
|
||||
WhatAlarm w = (WhatAlarm) msg.getWhat();
|
||||
if (w == null) {
|
||||
logger.debug("Alarm.updateZone() WHAT is null. Frame={}", msg);
|
||||
return;
|
||||
}
|
||||
switch (w) {
|
||||
case ZONE_DISENGAGED:
|
||||
case ZONE_ENGAGED:
|
||||
updateZoneState(w);
|
||||
break;
|
||||
case ZONE_ALARM_INTRUSION:
|
||||
case ZONE_ALARM_TAMPERING:
|
||||
case ZONE_ALARM_ANTI_PANIC:
|
||||
case ZONE_ALARM_SILENT:
|
||||
updateZoneAlarmState(w);
|
||||
break;
|
||||
case ZONE_ALARM_TECHNICAL:// not handled for now
|
||||
case ZONE_ALARM_TECHNICAL_RESET:
|
||||
default:
|
||||
logger.debug("Alarm.updateZone() Ignoring unsupported WHAT {}. Frame={}", msg.getWhat(), msg);
|
||||
}
|
||||
}
|
||||
|
||||
private void updateZoneState(WhatAlarm w) {
|
||||
updateState(CHANNEL_ALARM_ZONE_STATE, OnOffType.from(w == Alarm.WhatAlarm.ZONE_ENGAGED));
|
||||
}
|
||||
|
||||
private void updateZoneAlarmState(WhatAlarm w) {
|
||||
if (w == Alarm.WhatAlarm.ZONE_ALARM_SILENT) {
|
||||
updateState(CHANNEL_ALARM_ZONE_ALARM_STATE, new StringType(SILENT));
|
||||
} else if (w == Alarm.WhatAlarm.ZONE_ALARM_INTRUSION) {
|
||||
updateState(CHANNEL_ALARM_ZONE_ALARM_STATE, new StringType(INTRUSION));
|
||||
} else if (w == Alarm.WhatAlarm.ZONE_ALARM_ANTI_PANIC) {
|
||||
updateState(CHANNEL_ALARM_ZONE_ALARM_STATE, new StringType(ANTI_PANIC));
|
||||
} else {
|
||||
updateState(CHANNEL_ALARM_ZONE_ALARM_STATE, new StringType(TAMPERING));
|
||||
}
|
||||
}
|
||||
|
||||
@Override
|
||||
protected Where buildBusWhere(String wStr) throws IllegalArgumentException {
|
||||
return new WhereAlarm(wStr);
|
||||
}
|
||||
|
||||
@Override
|
||||
protected String ownIdPrefix() {
|
||||
return Who.BURGLAR_ALARM.value().toString();
|
||||
}
|
||||
}
|
|
@ -48,6 +48,7 @@ import org.openwebnet4j.OpenGateway;
|
|||
import org.openwebnet4j.USBGateway;
|
||||
import org.openwebnet4j.communication.OWNAuthException;
|
||||
import org.openwebnet4j.communication.OWNException;
|
||||
import org.openwebnet4j.message.Alarm;
|
||||
import org.openwebnet4j.message.Automation;
|
||||
import org.openwebnet4j.message.Auxiliary;
|
||||
import org.openwebnet4j.message.BaseOpenMessage;
|
||||
|
@ -67,7 +68,8 @@ import org.slf4j.Logger;
|
|||
import org.slf4j.LoggerFactory;
|
||||
|
||||
/**
|
||||
* The {@link OpenWebNetBridgeHandler} is responsible for handling communication with gateways and handling events.
|
||||
* The {@link OpenWebNetBridgeHandler} is responsible for handling communication
|
||||
* with gateways and handling events.
|
||||
*
|
||||
* @author Massimo Valla - Initial contribution, Lighting, Automation, Scenario
|
||||
* @author Andrea Conte - Energy management, Thermoregulation
|
||||
|
@ -95,7 +97,8 @@ public class OpenWebNetBridgeHandler extends ConfigStatusBridgeHandler implement
|
|||
public static final Set<ThingTypeUID> SUPPORTED_THING_TYPES = OpenWebNetBindingConstants.BRIDGE_SUPPORTED_THING_TYPES;
|
||||
|
||||
// ConcurrentHashMap of devices registered to this BridgeHandler
|
||||
// association is: ownId (String) -> OpenWebNetThingHandler, with ownId = WHO.WHERE
|
||||
// association is: ownId (String) -> OpenWebNetThingHandler, with ownId =
|
||||
// WHO.WHERE
|
||||
private Map<String, @Nullable OpenWebNetThingHandler> registeredDevices = new ConcurrentHashMap<>();
|
||||
private Map<String, Long> discoveringDevices = new ConcurrentHashMap<>();
|
||||
|
||||
|
@ -296,10 +299,10 @@ public class OpenWebNetBridgeHandler extends ConfigStatusBridgeHandler implement
|
|||
public void onNewDevice(@Nullable Where w, @Nullable OpenDeviceType deviceType, @Nullable BaseOpenMessage message) {
|
||||
OpenWebNetDeviceDiscoveryService discService = deviceDiscoveryService;
|
||||
if (discService != null) {
|
||||
if (w != null && deviceType != null) {
|
||||
if (deviceType != null) {
|
||||
discService.newDiscoveryResult(w, deviceType, message);
|
||||
} else {
|
||||
logger.warn("onNewDevice with null where/deviceType, msg={}", message);
|
||||
logger.warn("onNewDevice with null deviceType, msg={}", message);
|
||||
}
|
||||
} else {
|
||||
logger.warn("onNewDevice but null deviceDiscoveryService");
|
||||
|
@ -312,7 +315,8 @@ public class OpenWebNetBridgeHandler extends ConfigStatusBridgeHandler implement
|
|||
}
|
||||
|
||||
/**
|
||||
* Notifies that the scan has been stopped/aborted by OpenWebNetDeviceDiscoveryService
|
||||
* Notifies that the scan has been stopped/aborted by
|
||||
* OpenWebNetDeviceDiscoveryService
|
||||
*/
|
||||
public void scanStopped() {
|
||||
scanIsActive = false;
|
||||
|
@ -328,7 +332,8 @@ public class OpenWebNetBridgeHandler extends ConfigStatusBridgeHandler implement
|
|||
}
|
||||
// we support these types only
|
||||
if (baseMsg instanceof Lighting || baseMsg instanceof Automation || baseMsg instanceof EnergyManagement
|
||||
|| baseMsg instanceof Thermoregulation || baseMsg instanceof CEN || baseMsg instanceof Scenario) {
|
||||
|| baseMsg instanceof Thermoregulation || baseMsg instanceof CEN || baseMsg instanceof Scenario
|
||||
|| baseMsg instanceof Alarm) {
|
||||
BaseOpenMessage bmsg = baseMsg;
|
||||
if (baseMsg instanceof Lighting) {
|
||||
What what = baseMsg.getWhat();
|
||||
|
@ -433,7 +438,8 @@ public class OpenWebNetBridgeHandler extends ConfigStatusBridgeHandler implement
|
|||
return;
|
||||
}
|
||||
} else if (System.currentTimeMillis() - lastRegisteredDeviceTS < REFRESH_ALL_DEVICES_DELAY_MSEC) {
|
||||
// a device has been registered with the bridge just now, let's wait for other devices: re-schedule
|
||||
// a device has been registered with the bridge just now, let's wait for other
|
||||
// devices: re-schedule
|
||||
// refreshAllDevices
|
||||
logger.debug("--- REGISTER device just called... re-scheduling refreshAllBridgeDevices()");
|
||||
refreshAllSchedule = scheduler.schedule(this::refreshAllBridgeDevices, REFRESH_ALL_DEVICES_DELAY_MSEC,
|
||||
|
@ -501,7 +507,7 @@ public class OpenWebNetBridgeHandler extends ConfigStatusBridgeHandler implement
|
|||
// let's try to get the Thing associated with this message...
|
||||
if (baseMsg instanceof Lighting || baseMsg instanceof Automation || baseMsg instanceof EnergyManagement
|
||||
|| baseMsg instanceof Thermoregulation || baseMsg instanceof CEN || baseMsg instanceof Auxiliary
|
||||
|| baseMsg instanceof Scenario) {
|
||||
|| baseMsg instanceof Scenario || baseMsg instanceof Alarm) {
|
||||
String ownId = ownIdFromMessage(baseMsg);
|
||||
logger.debug("ownIdFromMessage({}) --> {}", baseMsg, ownId);
|
||||
OpenWebNetThingHandler deviceHandler = registeredDevices.get(ownId);
|
||||
|
@ -665,7 +671,16 @@ public class OpenWebNetBridgeHandler extends ConfigStatusBridgeHandler implement
|
|||
* @return the ownId String
|
||||
*/
|
||||
public String ownIdFromMessage(BaseOpenMessage baseMsg) {
|
||||
return baseMsg.getWho().value() + "." + normalizeWhere(baseMsg.getWhere());
|
||||
@Nullable
|
||||
Where w = baseMsg.getWhere();
|
||||
if (w != null) {
|
||||
return baseMsg.getWho().value() + "." + normalizeWhere(w);
|
||||
} else if (baseMsg instanceof Alarm) { // null and Alarm
|
||||
return baseMsg.getWho().value() + "." + "0"; // Alarm System --> where=0
|
||||
} else {
|
||||
logger.warn("ownIdFromMessage with null where: {}", baseMsg);
|
||||
return "";
|
||||
}
|
||||
}
|
||||
|
||||
/**
|
||||
|
@ -690,7 +705,8 @@ public class OpenWebNetBridgeHandler extends ConfigStatusBridgeHandler implement
|
|||
str = ((WhereZigBee) where).valueWithUnit(WhereZigBee.UNIT_ALL); // 76543210X#9 --> 765432100#9
|
||||
} else {
|
||||
if (str.indexOf("#4#") == -1) { // skip APL#4#bus case
|
||||
if (str.indexOf('#') == 0) { // Thermo central unit (#0) or zone via central unit (#Z, Z=[1-99]) --> Z
|
||||
if (str.indexOf('#') == 0) { // Thermo central unit (#0) or zone via central unit (#Z, Z=[1-99]) --> Z,
|
||||
// Alarm Zone (#Z) --> Z
|
||||
str = str.substring(1);
|
||||
} else if (str.indexOf('#') > 0) { // Thermo zone Z and actuator N (Z#N, Z=[1-99], N=[1-9]) --> Z
|
||||
str = str.substring(0, str.indexOf('#'));
|
||||
|
|
|
@ -5,6 +5,10 @@ binding.openwebnet.description = The OpenWebNet Binding integrates the BTicino/L
|
|||
|
||||
# thing types
|
||||
|
||||
thing-type.openwebnet.bus_alarm_system.label = Alarm System
|
||||
thing-type.openwebnet.bus_alarm_system.description = A OpenWebNet BUS/SCS alarm system.
|
||||
thing-type.openwebnet.bus_alarm_zone.label = Alarm Zone
|
||||
thing-type.openwebnet.bus_alarm_zone.description = A OpenWebNet BUS/SCS configured alarm zone.
|
||||
thing-type.openwebnet.bus_automation.label = Automation
|
||||
thing-type.openwebnet.bus_automation.description = An OpenWebNet BUS/SCS automation device to control roller shutters, blinds, etc. BTicino models: xxx/yyyy/etc.
|
||||
thing-type.openwebnet.bus_aux.label = Auxiliary
|
||||
|
@ -46,6 +50,10 @@ thing-type.openwebnet.zb_on_off_switch2u.description = An OpenWebNet ZigBee 2-un
|
|||
|
||||
# thing types config
|
||||
|
||||
thing-type.config.openwebnet.bus_alarm_system.where.label = OpenWebNet Address (where)
|
||||
thing-type.config.openwebnet.bus_alarm_system.where.description = The alarm system has no where address (set where to 0 as default).
|
||||
thing-type.config.openwebnet.bus_alarm_zone.where.label = OpenWebNet Address (where)
|
||||
thing-type.config.openwebnet.bus_alarm_zone.where.description = Example: alarm zone 2 --> where=2.
|
||||
thing-type.config.openwebnet.bus_automation.shutterRun.label = Shutter Run
|
||||
thing-type.config.openwebnet.bus_automation.shutterRun.description = Time (in ms) to go from max position (e.g. CLOSED) to the other position (e.g. OPEN). Example: 12000 (=12sec). Use AUTO (default) to calibrate the shutter automatically (UP->DOWN->Position%) the first time a Position command (%) is sent.
|
||||
thing-type.config.openwebnet.bus_automation.where.label = OpenWebNet Address (where)
|
||||
|
@ -117,6 +125,19 @@ channel-type.openwebnet.actuators.state.option.ON_SPEED_3 = ON speed 3
|
|||
channel-type.openwebnet.actuators.state.option.OFF_SPEED_1 = OFF speed 1
|
||||
channel-type.openwebnet.actuators.state.option.OFF_SPEED_2 = OFF speed 2
|
||||
channel-type.openwebnet.actuators.state.option.OFF_SPEED_3 = OFF speed 3
|
||||
channel-type.openwebnet.alarmBattery.label = Battery State
|
||||
channel-type.openwebnet.alarmBattery.description = Alarm system battery state (read only).
|
||||
channel-type.openwebnet.alarmBattery.state.option.OK = Ok
|
||||
channel-type.openwebnet.alarmBattery.state.option.FAULT = Fault
|
||||
channel-type.openwebnet.alarmBattery.state.option.UNLOADED = Unloaded
|
||||
channel-type.openwebnet.alarmNetwork.label = Network State
|
||||
channel-type.openwebnet.alarmNetwork.description = Alarm system network state (ON = network OK, OFF = no network) (read only).
|
||||
channel-type.openwebnet.alarmSystemState.label = System State
|
||||
channel-type.openwebnet.alarmSystemState.description = Alarm system is active (ON) or inactive (OFF) (read only).
|
||||
channel-type.openwebnet.alarmZoneState.label = Alarm Zone State
|
||||
channel-type.openwebnet.alarmZoneState.description = Alarm zone is active (ON) or inactive (OFF) (read only).
|
||||
channel-type.openwebnet.armedState.label = Armed State
|
||||
channel-type.openwebnet.armedState.description = Alarm is armed (ON) or disarmed (OFF) (read only).
|
||||
channel-type.openwebnet.atLeastOneProbeManual.label = At least one probe in MANUAL
|
||||
channel-type.openwebnet.atLeastOneProbeManual.description = At least one probe in MANUAL indicator in Central Unit (read only)
|
||||
channel-type.openwebnet.atLeastOneProbeOff.label = At least one probe OFF
|
||||
|
@ -144,20 +165,8 @@ channel-type.openwebnet.brightness.label = Brightness
|
|||
channel-type.openwebnet.brightness.description = Control the brightness and switch the light ON and OFF (read/write)
|
||||
channel-type.openwebnet.cenButtonEvent.label = CEN Button Event
|
||||
channel-type.openwebnet.cenButtonEvent.description = Event corresponding to the button press (read only)
|
||||
|
||||
# channel-type.openwebnet.cenButtonEvent.event.option.START_PRESS = Start press
|
||||
# channel-type.openwebnet.cenButtonEvent.event.option.SHORT_PRESS = Release after short press
|
||||
# channel-type.openwebnet.cenButtonEvent.event.option.EXTENDED_PRESS = Extended press (repeated until release)
|
||||
# channel-type.openwebnet.cenButtonEvent.event.option.RELEASE_EXTENDED_PRESS = Release after extended press
|
||||
|
||||
channel-type.openwebnet.cenPlusButtonEvent.label = CEN+ Button Event
|
||||
channel-type.openwebnet.cenPlusButtonEvent.description = Event corresponding to the button press (read only)
|
||||
|
||||
# channel-type.openwebnet.cenPlusButtonEvent.event.option.SHORT_PRESS = Short press
|
||||
# channel-type.openwebnet.cenPlusButtonEvent.event.option.START_EXTENDED_PRESS = Start of extended press
|
||||
# channel-type.openwebnet.cenPlusButtonEvent.event.option.EXTENDED_PRESS = Extended press (repeated until release)
|
||||
# channel-type.openwebnet.cenPlusButtonEvent.event.option.RELEASE_EXTENDED_PRESS = Release after extended press
|
||||
|
||||
channel-type.openwebnet.conditioningValves.label = Conditioning Valves
|
||||
channel-type.openwebnet.conditioningValves.description = Conditioning Valves status (read only)
|
||||
channel-type.openwebnet.conditioningValves.state.option.OFF = OFF
|
||||
|
@ -230,28 +239,6 @@ channel-type.openwebnet.remoteControl.state.option.DISABLED = DISABLED
|
|||
channel-type.openwebnet.remoteControl.state.option.ENABLED = ENABLED
|
||||
channel-type.openwebnet.scenarioEvent.label = Activated Scenario Event
|
||||
channel-type.openwebnet.scenarioEvent.description = Event corresponding to the number of Basic Scenario that has been activated (read only)
|
||||
|
||||
# channel-type.openwebnet.scenarioEvent.event.option.SCENARIO_01 = Scenario 1
|
||||
# channel-type.openwebnet.scenarioEvent.event.option.SCENARIO_02 = Scenario 2
|
||||
# channel-type.openwebnet.scenarioEvent.event.option.SCENARIO_03 = Scenario 3
|
||||
# channel-type.openwebnet.scenarioEvent.event.option.SCENARIO_04 = Scenario 4
|
||||
# channel-type.openwebnet.scenarioEvent.event.option.SCENARIO_05 = Scenario 5
|
||||
# channel-type.openwebnet.scenarioEvent.event.option.SCENARIO_06 = Scenario 6
|
||||
# channel-type.openwebnet.scenarioEvent.event.option.SCENARIO_07 = Scenario 7
|
||||
# channel-type.openwebnet.scenarioEvent.event.option.SCENARIO_08 = Scenario 8
|
||||
# channel-type.openwebnet.scenarioEvent.event.option.SCENARIO_09 = Scenario 9
|
||||
# channel-type.openwebnet.scenarioEvent.event.option.SCENARIO_10 = Scenario 10
|
||||
# channel-type.openwebnet.scenarioEvent.event.option.SCENARIO_11 = Scenario 11
|
||||
# channel-type.openwebnet.scenarioEvent.event.option.SCENARIO_12 = Scenario 12
|
||||
# channel-type.openwebnet.scenarioEvent.event.option.SCENARIO_13 = Scenario 13
|
||||
# channel-type.openwebnet.scenarioEvent.event.option.SCENARIO_14 = Scenario 14
|
||||
# channel-type.openwebnet.scenarioEvent.event.option.SCENARIO_15 = Scenario 15
|
||||
# channel-type.openwebnet.scenarioEvent.event.option.SCENARIO_16 = Scenario 16
|
||||
# channel-type.openwebnet.scenarioEvent.event.option.SCENARIO_17 = Scenario 17
|
||||
# channel-type.openwebnet.scenarioEvent.event.option.SCENARIO_18 = Scenario 18
|
||||
# channel-type.openwebnet.scenarioEvent.event.option.SCENARIO_19 = Scenario 19
|
||||
# channel-type.openwebnet.scenarioEvent.event.option.SCENARIO_20 = Scenario 20
|
||||
|
||||
channel-type.openwebnet.scenarioProgramCentralUnit.label = Scenario Program Number
|
||||
channel-type.openwebnet.scenarioProgramCentralUnit.description = Set scenario program number for the Central Unit, valid only with Central Unit mode = "SCENARIO" (read/write)
|
||||
channel-type.openwebnet.scenarioProgramCentralUnit.state.option.1 = Program 1
|
||||
|
@ -289,6 +276,12 @@ channel-type.openwebnet.weeklyProgramCentralUnit.description = Set weekly progra
|
|||
channel-type.openwebnet.weeklyProgramCentralUnit.state.option.1 = Program 1
|
||||
channel-type.openwebnet.weeklyProgramCentralUnit.state.option.2 = Program 2
|
||||
channel-type.openwebnet.weeklyProgramCentralUnit.state.option.3 = Program 3
|
||||
channel-type.openwebnet.zoneAlarm.label = Zone Alarm
|
||||
channel-type.openwebnet.zoneAlarm.description = Current alarm for the zone (read only).
|
||||
channel-type.openwebnet.zoneAlarm.state.option.INTRUSION = Intrusion
|
||||
channel-type.openwebnet.zoneAlarm.state.option.TAMPERING = Tampering
|
||||
channel-type.openwebnet.zoneAlarm.state.option.ANTI_PANIC = Anti Panic
|
||||
channel-type.openwebnet.zoneAlarm.state.option.SILENT = Silent
|
||||
|
||||
# thing status descriptions
|
||||
|
||||
|
|
|
@ -0,0 +1,41 @@
|
|||
<?xml version="1.0" encoding="UTF-8"?>
|
||||
<thing:thing-descriptions bindingId="openwebnet"
|
||||
xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
|
||||
xmlns:thing="https://openhab.org/schemas/thing-description/v1.0.0"
|
||||
xsi:schemaLocation="https://openhab.org/schemas/thing-description/v1.0.0 https://openhab.org/schemas/thing-description-1.0.0.xsd">
|
||||
|
||||
<!-- Thing for BUS Alarm System -->
|
||||
<thing-type id="bus_alarm_system">
|
||||
<supported-bridge-type-refs>
|
||||
<bridge-type-ref id="bus_gateway"/>
|
||||
</supported-bridge-type-refs>
|
||||
|
||||
<label>Alarm System</label>
|
||||
<description>A OpenWebNet BUS/SCS alarm system.</description>
|
||||
|
||||
<channels>
|
||||
<!-- read only -->
|
||||
<channel id="state" typeId="alarmSystemState"/>
|
||||
<channel id="armed" typeId="armedState"/>
|
||||
<channel id="network" typeId="alarmNetwork"/>
|
||||
<channel id="battery" typeId="alarmBattery"/>
|
||||
</channels>
|
||||
|
||||
<properties>
|
||||
<property name="vendor">BTicino/Legrand</property>
|
||||
<property name="model">BTicino Burglar-alarm Unit 3486</property>
|
||||
<property name="ownDeviceType">5100</property>
|
||||
</properties>
|
||||
|
||||
<representation-property>ownId</representation-property>
|
||||
|
||||
<config-description>
|
||||
<parameter name="where" type="text" readOnly="true">
|
||||
<label>OpenWebNet Address (where)</label>
|
||||
<description>The alarm system has no where address (set where to 0 as default).</description>
|
||||
<default>0</default>
|
||||
</parameter>
|
||||
</config-description>
|
||||
|
||||
</thing-type>
|
||||
</thing:thing-descriptions>
|
|
@ -0,0 +1,38 @@
|
|||
<?xml version="1.0" encoding="UTF-8"?>
|
||||
<thing:thing-descriptions bindingId="openwebnet"
|
||||
xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
|
||||
xmlns:thing="https://openhab.org/schemas/thing-description/v1.0.0"
|
||||
xsi:schemaLocation="https://openhab.org/schemas/thing-description/v1.0.0 https://openhab.org/schemas/thing-description-1.0.0.xsd">
|
||||
|
||||
<!-- Thing for BUS Alarm Zone -->
|
||||
<thing-type id="bus_alarm_zone">
|
||||
<supported-bridge-type-refs>
|
||||
<bridge-type-ref id="bus_gateway"/>
|
||||
</supported-bridge-type-refs>
|
||||
|
||||
<label>Alarm Zone</label>
|
||||
<description>A OpenWebNet BUS/SCS configured alarm zone.</description>
|
||||
|
||||
<channels>
|
||||
<!-- read only -->
|
||||
<channel id="state" typeId="alarmZoneState"/>
|
||||
<channel id="alarm" typeId="zoneAlarm"/>
|
||||
</channels>
|
||||
|
||||
<properties>
|
||||
<property name="vendor">BTicino/Legrand</property>
|
||||
<property name="model">Alarm zone as configured in the Alarm System Unit</property>
|
||||
<property name="ownDeviceType">5200</property>
|
||||
</properties>
|
||||
|
||||
<representation-property>ownId</representation-property>
|
||||
|
||||
<config-description>
|
||||
<parameter name="where" type="text" required="true">
|
||||
<label>OpenWebNet Address (where)</label>
|
||||
<description>Example: alarm zone 2 --> where=2.</description>
|
||||
</parameter>
|
||||
</config-description>
|
||||
|
||||
</thing-type>
|
||||
</thing:thing-descriptions>
|
|
@ -409,4 +409,59 @@
|
|||
<state readOnly="true"></state>
|
||||
</channel-type>
|
||||
|
||||
<!-- Alarm channels -->
|
||||
<channel-type id="alarmSystemState">
|
||||
<item-type>Switch</item-type>
|
||||
<label>System State</label>
|
||||
<description>Alarm system is active (ON) or inactive (OFF) (read only).</description>
|
||||
<state readOnly="true"/>
|
||||
</channel-type>
|
||||
|
||||
<channel-type id="armedState">
|
||||
<item-type>Switch</item-type>
|
||||
<label>Armed State</label>
|
||||
<description>Alarm is armed (ON) or disarmed (OFF) (read only).</description>
|
||||
<state readOnly="true"/>
|
||||
</channel-type>
|
||||
|
||||
<channel-type id="alarmNetwork">
|
||||
<item-type>Switch</item-type>
|
||||
<label>Network State</label>
|
||||
<description>Alarm system network state (ON = network OK, OFF = no network) (read only).</description>
|
||||
<state readOnly="true"/>
|
||||
</channel-type>
|
||||
|
||||
<channel-type id="alarmBattery">
|
||||
<item-type>String</item-type>
|
||||
<label>Battery State</label>
|
||||
<description>Alarm system battery state (read only).</description>
|
||||
<state readOnly="true">
|
||||
<options>
|
||||
<option value="OK">Ok</option>
|
||||
<option value="FAULT">Fault</option>
|
||||
<option value="UNLOADED">Unloaded</option>
|
||||
</options>
|
||||
</state>
|
||||
</channel-type>
|
||||
|
||||
<channel-type id="zoneAlarm">
|
||||
<item-type>String</item-type>
|
||||
<label>Zone Alarm</label>
|
||||
<description>Current alarm for the zone (read only).</description>
|
||||
<state readOnly="true">
|
||||
<options>
|
||||
<option value="INTRUSION">Intrusion</option>
|
||||
<option value="TAMPERING">Tampering</option>
|
||||
<option value="ANTI_PANIC">Anti Panic</option>
|
||||
<option value="SILENT">Silent</option>
|
||||
</options>
|
||||
</state>
|
||||
</channel-type>
|
||||
|
||||
<channel-type id="alarmZoneState">
|
||||
<item-type>Switch</item-type>
|
||||
<label>Alarm Zone State</label>
|
||||
<description>Alarm zone is active (ON) or inactive (OFF) (read only).</description>
|
||||
<state readOnly="true"/>
|
||||
</channel-type>
|
||||
</thing:thing-descriptions>
|
||||
|
|
|
@ -22,6 +22,7 @@ import org.openhab.core.thing.Bridge;
|
|||
import org.openwebnet4j.message.BaseOpenMessage;
|
||||
import org.openwebnet4j.message.FrameException;
|
||||
import org.openwebnet4j.message.Where;
|
||||
import org.openwebnet4j.message.WhereAlarm;
|
||||
import org.openwebnet4j.message.WhereAuxiliary;
|
||||
import org.openwebnet4j.message.WhereCEN;
|
||||
import org.openwebnet4j.message.WhereEnergyManagement;
|
||||
|
@ -33,11 +34,11 @@ import org.slf4j.Logger;
|
|||
import org.slf4j.LoggerFactory;
|
||||
|
||||
/**
|
||||
* Test class for {@link OpenWebNetBridgeHandler#ownID} and ThingID
|
||||
* calculation using {@link OpenWebNetBridgeHandler}
|
||||
* methods: normalizeWhere(), ownIdFromWhoWhere(), ownIdFromMessage(), thingIdFromWhere()
|
||||
* Test class for {@link OpenWebNetBridgeHandler#ownID} and ThingID calculation
|
||||
* using {@link OpenWebNetBridgeHandler} methods: normalizeWhere(),
|
||||
* ownIdFromWhoWhere(), ownIdFromMessage(), thingIdFromWhere()
|
||||
*
|
||||
* @author Massimo Valla - Initial contribution
|
||||
* @author Massimo Valla - Initial contribution, updates
|
||||
* @author Andrea Conte - Energy management
|
||||
* @author Giovanni Fabiani - Auxiliary message support
|
||||
*/
|
||||
|
@ -48,7 +49,6 @@ public class OwnIdTest {
|
|||
|
||||
// @formatter:off
|
||||
/**
|
||||
*
|
||||
* deviceWhere
|
||||
* (DevAddrParam)
|
||||
* TYPE WHERE = normalizeWhere() ownId ThingID
|
||||
|
@ -68,29 +68,34 @@ public class OwnIdTest {
|
|||
* BUS DryContact 399 399 25.399 399
|
||||
* BUS AUX 4 4 9.4 4
|
||||
* BUS Scenario 05 05 0.05 05
|
||||
* BUS Alarm Zone #2 or 2 2 5.2 2
|
||||
* BUS Alarm silent 0 0 5.0 0
|
||||
* BUS Alarm system null 0 5.0 0
|
||||
*/
|
||||
// @formatter:on
|
||||
|
||||
public enum TEST {
|
||||
// @formatter:off
|
||||
zb_switch(new WhereZigBee("789309801#9"), Who.fromValue(1), "*1*1*789309801#9##", "789309800h9", "1.789309800h9", "789309800h9"),
|
||||
zb_switch_2u_1(new WhereZigBee("789301201#9"), Who.fromValue(1), "*1*1*789301201#9##", "789301200h9", "1.789301200h9", "789301200h9"),
|
||||
zb_switch_2u_2(new WhereZigBee("789301202#9"), Who.fromValue(1), "*1*1*789301202#9##", "789301200h9", "1.789301200h9", "789301200h9"),
|
||||
bus_switch(new WhereLightAutom("51"), Who.fromValue(1), "*1*1*51##", "51", "1.51", "51"),
|
||||
bus_localbus(new WhereLightAutom("25#4#01"), Who.fromValue(1), "*1*1*25#4#01##", "25h4h01", "1.25h4h01", "25h4h01"),
|
||||
bus_autom(new WhereLightAutom("93"), Who.fromValue(2), "*2*0*93##", "93", "2.93", "93"),
|
||||
bus_thermo_via_cu(new WhereThermo("#1"), Who.fromValue(4),"*#4*#1*0*0020##" ,"1", "4.1", "1"),
|
||||
bus_thermo(new WhereThermo("1"), Who.fromValue(4),"*#4*1*0*0020##" , "1", "4.1", "1"),
|
||||
bus_thermo_act(new WhereThermo("1#2"), Who.fromValue(4),"*#4*1#2*20*0##" ,"1", "4.1", "1"),
|
||||
bus_tempSensor(new WhereThermo("500"), Who.fromValue(4), "*#4*500*15*1*0020*0001##", "500", "4.500", "500"),
|
||||
bus_energy(new WhereEnergyManagement("51"), Who.fromValue(18), "*#18*51*113##", "51", "18.51", "51"),
|
||||
bus_cen(new WhereCEN("51"), Who.fromValue(15), "*15*31*51##", "51", "15.51", "51"),
|
||||
bus_cen_plus(new WhereCEN("212"), Who.fromValue(25), "*25*21#31*212##", "212", "25.212", "212"),
|
||||
bus_drycontact(new WhereCEN("399"), Who.fromValue(25), "*25*32#1*399##", "399", "25.399", "399"),
|
||||
bus_aux(new WhereAuxiliary("4"), Who.fromValue(9), "*9*1*4##","4","9.4","4"),
|
||||
bus_scenario(new WhereLightAutom("05"), Who.fromValue(0), "*0*2*05##","05","0.05","05");
|
||||
|
||||
|
||||
// msg, who, where, normW, ownId, thingId
|
||||
zb_switch("*1*1*789309801#9##", Who.fromValue(1), new WhereZigBee("789309801#9"), "789309800h9", "1.789309800h9", "789309800h9"),
|
||||
zb_switch_2u_1("*1*1*789301201#9##", Who.fromValue(1), new WhereZigBee("789301201#9"), "789301200h9", "1.789301200h9", "789301200h9"),
|
||||
zb_switch_2u_2("*1*1*789301202#9##", Who.fromValue(1), new WhereZigBee("789301202#9"), "789301200h9", "1.789301200h9", "789301200h9"),
|
||||
bus_switch("*1*1*51##", Who.fromValue(1), new WhereLightAutom("51"),"51", "1.51", "51"),
|
||||
bus_localbus("*1*1*25#4#01##", Who.fromValue(1), new WhereLightAutom("25#4#01"), "25h4h01", "1.25h4h01", "25h4h01"),
|
||||
bus_autom("*2*0*93##",Who.fromValue(2), new WhereLightAutom("93"), "93", "2.93", "93"),
|
||||
bus_thermo_via_cu("*#4*#1*0*0020##", Who.fromValue(4), new WhereThermo("#1"), "1", "4.1", "1"),
|
||||
bus_thermo("*#4*1*0*0020##", Who.fromValue(4), new WhereThermo("1"), "1", "4.1", "1"),
|
||||
bus_thermo_act("*#4*1#2*20*0##", Who.fromValue(4), new WhereThermo("1#2") ,"1", "4.1", "1"),
|
||||
bus_tempSensor("*#4*500*15*1*0020*0001##",Who.fromValue(4), new WhereThermo("500"), "500", "4.500", "500"),
|
||||
bus_energy("*#18*51*113##", Who.fromValue(18), new WhereEnergyManagement("51"), "51", "18.51", "51"),
|
||||
bus_cen("*15*31*51##", Who.fromValue(15), new WhereCEN("51"), "51", "15.51", "51"),
|
||||
bus_cen_plus("*25*21#31*212##", Who.fromValue(25), new WhereCEN("212"), "212", "25.212", "212"),
|
||||
bus_drycontact("*25*32#1*399##", Who.fromValue(25), new WhereCEN("399"), "399", "25.399", "399"),
|
||||
bus_aux( "*9*1*4##", Who.fromValue(9), new WhereAuxiliary("4"),"4","9.4","4"),
|
||||
bus_scenario( "*0*2*05##", Who.fromValue(0), new WhereLightAutom("05"), "05","0.05","05"),
|
||||
bus_alarm_zh("*#5*#2##", Who.fromValue(5), new WhereAlarm("#2"), "2", "5.2", "2"),
|
||||
bus_alarm_silent("*5*2*0##", Who.fromValue(5), new WhereAlarm("0"), "0", "5.0", "0"),
|
||||
bus_alarm_system( "*5*7*##", Who.fromValue(5),new WhereAlarm("0"), "0", "5.0", "0");
|
||||
|
||||
// @formatter:on
|
||||
|
||||
|
@ -101,7 +106,7 @@ public class OwnIdTest {
|
|||
public final @Nullable BaseOpenMessage msg;
|
||||
public final String norm, ownId, thingId;
|
||||
|
||||
private TEST(Where where, Who who, String msg, String norm, String ownId, String thingId) {
|
||||
private TEST(String msg, Who who, Where where, String norm, String ownId, String thingId) {
|
||||
this.where = where;
|
||||
this.who = who;
|
||||
BaseOpenMessage bmsg = null;
|
||||
|
@ -125,7 +130,7 @@ public class OwnIdTest {
|
|||
BaseOpenMessage bmsg;
|
||||
for (int i = 0; i < TEST.values().length; i++) {
|
||||
TEST test = TEST.values()[i];
|
||||
logger.info("testing where={}", test.where);
|
||||
logger.info("testing {} (who={} where={})", test.msg, test.who, test.where);
|
||||
assertEquals(test.norm, brH.normalizeWhere(test.where));
|
||||
assertEquals(test.ownId, brH.ownIdFromWhoWhere(test.who, test.where));
|
||||
bmsg = test.msg;
|
||||
|
|