[wolfsmartset] Initial contribution (#10751)
Signed-off-by: Bo Biene <openhab.github@biene.eu>
This commit is contained in:
149
bundles/org.openhab.binding.wolfsmartset/README.md
Normal file
149
bundles/org.openhab.binding.wolfsmartset/README.md
Normal file
@@ -0,0 +1,149 @@
|
||||
# Wolf Smartset Binding
|
||||
|
||||
This binding communicates with the www.wolf-smartset.de API and provides values readonly.
|
||||
Wolf systems are connected with official gateways (Wolf Link Home or Wolf Link Pro) https://www.wolf.eu/produkte/smarthome/
|
||||
|
||||
## Supported Things
|
||||
|
||||
- Account (``thing-type:wolfsmartset:account``)
|
||||
* holding the credentials to connect to the wolf-smartset online portal.
|
||||
- System (``thing-type:wolfsmartset:system``)
|
||||
* represents one wolf system connected to the wolf-smartset online portal.
|
||||
- Unit (``thing-type:wolfsmartset:unit``)
|
||||
* unit is a part of the system with values and parameter
|
||||
|
||||
## Discovery
|
||||
|
||||
- System things (bridge) are discovered after Account thing (bridge) is set up
|
||||
- Unit things are discovered after System things are set up
|
||||
|
||||
## Thing Configuration
|
||||
|
||||
### Account (bridge)
|
||||
|
||||
The account thing holds the credentials to connect to the wolf-smartset online portal.
|
||||
|
||||
| Parameter | Type | Defaut | Description |
|
||||
|-----------------|---------|----------|---------------------------------------------------------------------|
|
||||
| username | text | | username to authenticate to www.wolf-smartset.de |
|
||||
| password | text | | password to authenticate to www.wolf-smartset.de |
|
||||
| refreshIntervalStructure | integer | 10 | Specifies the refresh interval to refresh the Structure in minutes |
|
||||
| refreshIntervalValues | integer | 15 | Specifies time in seconds to refresh values |
|
||||
| discoveryEnabled | boolean | true | disable the Thing discovery |
|
||||
|
||||
### System (bridge)
|
||||
|
||||
The system thing represents one wolf system connected via a WOLF Link home or a WOLF Link pro to the wolf-smartset online portal.
|
||||
You have access to your own or to shared systems.
|
||||
|
||||
| Parameter | Type | Defaut | Description |
|
||||
|-----------------|---------|----------|---------------------------------------------------------------------|
|
||||
| systemId | integer | | System ID assigned to the system by WolfSmartset |
|
||||
|
||||
### Unit
|
||||
|
||||
A system is divided into different units.
|
||||
In the wolf-smartset portal, the system has an "Expert" section, each submenu item within the "Expert" section has multiple tabs.
|
||||
Each of these tabs is treated as one unit.
|
||||
|
||||
| Parameter | Type | Defaut | Description |
|
||||
|-----------------|---------|----------|---------------------------------------------------------------------|
|
||||
| unitId | integer | | The BundleId assigned to the unit by WolfSmartset |
|
||||
|
||||
## Tested WOLF-Devices
|
||||
|
||||
| WOLF Equipment | openhab Version | Used gateway |
|
||||
|-------------------|-----------------|---------------|
|
||||
| CSZ (CGB and SM1) | 3.1 | WOLF Link Pro |
|
||||
| CGB-2 | 3.1 | WOLF Link home|
|
||||
|
||||
|
||||
## Channels
|
||||
|
||||
| channel | type | description |
|
||||
|----------|--------|------------------------------|
|
||||
| number | Number | a generic number |
|
||||
| contact | Contact | a generic contact |
|
||||
| temperature | Number:Temperature | a generic temperature |
|
||||
| string | String | a generic String |
|
||||
| datetime | DateTime | a generic DateTime |
|
||||
|
||||
## Full Example
|
||||
|
||||
### Things
|
||||
|
||||
````
|
||||
Bridge wolfsmartset:account:account "Wolf Smartset Account" [ username="User", password="Password" ] {
|
||||
Bridge system 32122305166 "WolfSmartset System CSZ" [ systemId="32122305166" ] {
|
||||
Thing unitId uinit0 "CSZ Heizgerät" [ unitId="unit0" ] {
|
||||
}
|
||||
}
|
||||
}
|
||||
````
|
||||
_You need to use the corrosponding systemId and unitId returned by the discovery_
|
||||
|
||||
### Items
|
||||
|
||||
````
|
||||
"Number CSZHeizgerat_Raumtemperatur "Raumtemperatur" { channel="wolfsmartset:unit:account:32122305166:uinit0:1000900000"}
|
||||
Number CSZHeizgerat_Flamme "Flamme" { channel="wolfsmartset:unit:account:32122305166:uinit0:1000900001"}
|
||||
Number CSZHeizgerat_AnalogeFernbedienung "Analoge Fernbedienung" { channel="wolfsmartset:unit:account:32122305166:uinit0:1000900002"}
|
||||
Number CSZHeizgerat_Raumsolltemperatur "Raumsolltemperatur" { channel="wolfsmartset:unit:account:32122305166:uinit0:1000900003"}
|
||||
Number CSZHeizgerat_AusgangA1 "Ausgang A1" { channel="wolfsmartset:unit:account:32122305166:uinit0:1000900004"}
|
||||
String CSZHeizgerat_ZeitprogrammdirekterHeizkreis "Zeitprogramm direkter Heizkreis" { channel="wolfsmartset:unit:account:32122305166:uinit0:1000900005"}
|
||||
Number CSZHeizgerat_Ventil1 "Ventil 1" { channel="wolfsmartset:unit:account:32122305166:uinit0:1000900006"}
|
||||
Number CSZHeizgerat_Ventil2 "Ventil 2" { channel="wolfsmartset:unit:account:32122305166:uinit0:1000900007"}
|
||||
Number CSZHeizgerat_WiSoUmschaltung "Wi/So Umschaltung" { channel="wolfsmartset:unit:account:32122305166:uinit0:1000900008"}
|
||||
Number CSZHeizgerat_Tagtemperatur "Tagtemperatur" { channel="wolfsmartset:unit:account:32122305166:uinit0:1000900009"}
|
||||
Number CSZHeizgerat_PWMPumpe "PWM Pumpe" { channel="wolfsmartset:unit:account:32122305166:uinit0:10009000010"}
|
||||
Number CSZHeizgerat_Speichersolltemperatur "Speichersolltemperatur" { channel="wolfsmartset:unit:account:32122305166:uinit0:10009000011"}
|
||||
Number CSZHeizgerat_Heizkurve "Heizkurve" { channel="wolfsmartset:unit:account:32122305166:uinit0:10009000012"}
|
||||
Number CSZHeizgerat_Raumeinfluss "Raumeinfluss" { channel="wolfsmartset:unit:account:32122305166:uinit0:10009000013"}
|
||||
Number CSZHeizgerat_TWVorlauf "TW-Vorlauf" { channel="wolfsmartset:unit:account:32122305166:uinit0:10009000014"}
|
||||
Number CSZHeizgerat_Spartemperatur "Spartemperatur" { channel="wolfsmartset:unit:account:32122305166:uinit0:10009000015"}
|
||||
Number CSZHeizgerat_Geblase "Gebläse" { channel="wolfsmartset:unit:account:32122305166:uinit0:10009000016"}
|
||||
Number CSZHeizgerat_Vorlaufsolltemperatur "Vorlaufsolltemperatur" { channel="wolfsmartset:unit:account:32122305166:uinit0:10009000017"}
|
||||
Group CSZHeizgerat "CSZ Heizgerät" { channel="wolfsmartset:unit:account:32122305166:uinit0:10009000018"}
|
||||
Number CSZHeizgerat_ECOABS "ECO/ABS" { channel="wolfsmartset:unit:account:32122305166:uinit0:10009000019"}
|
||||
Number CSZHeizgerat_Netzbetriebstunden "Netzbetriebstunden" { channel="wolfsmartset:unit:account:32122305166:uinit0:10009000020"}
|
||||
Number CSZHeizgerat_TWAbgas "TW-Abgas" { channel="wolfsmartset:unit:account:32122305166:uinit0:10009000021"}
|
||||
Number CSZHeizgerat_HGStatus "HG Status" { channel="wolfsmartset:unit:account:32122305166:uinit0:10009000022"}
|
||||
Number CSZHeizgerat_EingangE1 "Eingang E1" { channel="wolfsmartset:unit:account:32122305166:uinit0:10009000023"}"
|
||||
````
|
||||
|
||||
## Supported Heating-Devices
|
||||
|
||||
All devices able to be connected to www.wolf-smartset.de
|
||||
|
||||
### Related Documentation from WOLF
|
||||
|
||||
https://www.wolf.eu/fileadmin/Wolf_Daten/Dokumente/FAQ/3065655_201711.pdf
|
||||
|
||||
| Heating system | WOLF Link home | WOLF Link pro |
|
||||
|-------------------------------------------|-----------------------|--------------------|
|
||||
| Gas condensing boiler CGB-2, CGW-2, CGS-2 | ✅ | ✅ |
|
||||
| Oil condensing boiler TOB | ✅ | ✅ |
|
||||
| MGK-2 gas condensing boiler | ✅ | ✅ |
|
||||
| split air/water heat pump BWL-1S | ✅ | ✅ |
|
||||
| Oil condensing boiler COB | | ✅ |
|
||||
| gas condensing boiler MGK | | ✅ |
|
||||
| Gas condensing boilers CGB, CGW, CGS, FGB | | ✅ |
|
||||
| Gas condensing boilers CGG-2, CGU-2 | | ✅ |
|
||||
| Boiler controls R2, R3, R21 | | ✅ |
|
||||
| Monobloc heat pumps BWW-1, BWL-1, BWS-1 | | ✅ |
|
||||
| mixer module MM, MM-2 | ⬜ | ✅ |
|
||||
| cascade module KM, KM-2 | ⬜ | ✅ |
|
||||
| solar modules SM1, SM1-2, SM-2, SM2-2 | ⬜ | ✅ |
|
||||
| Comfort apartment ventilation CWL Excellent | ⬜ | ✅ |
|
||||
| Air handling units KG Top, CKL Pool``*`` | | ✅ |
|
||||
| Air handling units CKL, CFL, CRL``*`` | | ✅ |
|
||||
| Combined heat and power units | | ✅ |
|
||||
|
||||
|
||||
Note:
|
||||
|
||||
⬜ possible in connection with a WOLF Link home compatible heater,
|
||||
full functionality only for devices with current software version.
|
||||
|
||||
``*`` Modbus interface required in the device,
|
||||
Special programming cannot be mapped.
|
||||
Reference in New Issue
Block a user