Added support for HAN-FUN Color and Dimmable bulbs (#11723)
Signed-off-by: Christoph Weitkamp <github@christophweitkamp.de>
This commit is contained in:
committed by
GitHub
parent
4f26c65c0c
commit
95a2b333dd
@@ -92,6 +92,8 @@ The following sensors have been successfully tested using FRITZ!OS 7 for FRITZ!B
|
||||
- [SmartHome Zwischenstecker außen](https://www.smarthome.de/geraete/smarthome-zwischenstecker-aussen-schwarz) - a switchable outdoor outlet (thing type `HAN_FUN_ON_OFF`)
|
||||
- [Rollotron DECT 1213](https://www.rademacher.de/shop/rollladen-sonnenschutz/elektrischer-gurtwickler/rollotron-dect-1213) - an electronic belt winder (thing type `HAN_FUN_BLINDS`)
|
||||
- [Becker BoxCTRL](https://becker-antriebe.shop/) - a radio controlled roller shutter drive (thing type `HAN_FUN_BLINDS`)
|
||||
- SmartHome LED-Lampe E27 (farbig) - a dimmable colorized light bulb (thing type `HAN_FUN_COLOR_BULB`)
|
||||
- SmartHome LED-Lampe E27 (warmweiß) - a dimmable light bulb (thing type `HAN_FUN_DIMMABLE_BULB`)
|
||||
|
||||
The use of other Sensors should be possible, if these are compatible with DECT-ULE / HAN-FUN standards.
|
||||
|
||||
@@ -177,12 +179,14 @@ The AIN (actor identification number) can be found in the FRITZ!Box interface ->
|
||||
| locked | Contact | Device is locked for switching over external sources (OPEN/CLOSE) | FRITZ!DECT 210, FRITZ!DECT 200, FRITZ!Powerline 546E, FRITZ!DECT 301, FRITZ!DECT 300, Comet DECT |
|
||||
| device_locked | Contact | Device is locked for switching manually (OPEN/CLOSE) - FRITZ!OS 6.90 | FRITZ!DECT 210, FRITZ!DECT 200, FRITZ!Powerline 546E, FRITZ!DECT 301, FRITZ!DECT 300, Comet DECT |
|
||||
| temperature | Number:Temperature | Current measured temperature | FRITZ!DECT 210, FRITZ!DECT 200, FRITZ!DECT Repeater 100, FRITZ!DECT 301, FRITZ!DECT 300, Comet DECT, FRITZ!DECT 440 |
|
||||
| humidity | Number:Dimensionless | Current measured humidity - FRITZ!OS 7.24 | FRITZ!DECT 440 |
|
||||
| humidity | Number:Dimensionless | Current measured humidity - FRITZ!OS 7.24 | FRITZ!DECT 440 |
|
||||
| energy | Number:Energy | Accumulated energy consumption | FRITZ!DECT 210, FRITZ!DECT 200, FRITZ!Powerline 546E |
|
||||
| power | Number:Power | Current power consumption | FRITZ!DECT 210, FRITZ!DECT 200, FRITZ!Powerline 546E |
|
||||
| voltage | Number:ElectricPotential | Current voltage - FRITZ!OS 7 | FRITZ!DECT 210, FRITZ!DECT 200, FRITZ!Powerline 546E |
|
||||
| outlet | Switch | Switchable outlet (ON/OFF) | FRITZ!DECT 210, FRITZ!DECT 200, FRITZ!Powerline 546E |
|
||||
| on_off | Switch | Switchable device (ON/OFF) | FRITZ!DECT 500, HAN_FUN_ON_OFF |
|
||||
| on_off | Switch | Switchable device (ON/OFF) | HAN_FUN_ON_OFF |
|
||||
| brightness | Dimmer | Dimmable lights | HAN_FUN_DIMMABLE_BULB |
|
||||
| color | Color | Color lights | FRITZ!DECT 500, HAN_FUN_COLOR_BULB |
|
||||
| actual_temp | Number:Temperature | Current temperature of heating thermostat | FRITZ!DECT 301, FRITZ!DECT 300, Comet DECT |
|
||||
| set_temp | Number:Temperature | Set Temperature of heating thermostat | FRITZ!DECT 301, FRITZ!DECT 300, Comet DECT |
|
||||
| eco_temp | Number:Temperature | Eco Temperature of heating thermostat | FRITZ!DECT 301, FRITZ!DECT 300, Comet DECT |
|
||||
@@ -194,7 +198,7 @@ The AIN (actor identification number) can be found in the FRITZ!Box interface ->
|
||||
| battery_low | Switch | Battery level low (ON/OFF) - FRITZ!OS 6.80 | FRITZ!DECT 301, FRITZ!DECT 300, Comet DECT, FRITZ!DECT 400, FRITZ!DECT 440 |
|
||||
| contact_state | Contact | Contact state information (OPEN/CLOSED). | HAN-FUN contact (e.g. SmartHome Tür-/Fensterkontakt or SmartHome Bewegungsmelder)- FRITZ!OS 7 |
|
||||
| last_change | DateTime | States the last time the button was pressed. | FRITZ!DECT 400, FRITZ!DECT 440, HAN-FUN switch (e.g. SmartHome Wandtaster) - FRITZ!OS 7 |
|
||||
| rollershutter | Rollershutter | Rollershutter control and status. Accepts UP/DOWN/STOP commands and the opening level in percent. States the opening level in percent. | HAN-FUN blind (e.g. Rolltron DECT 1213) - FRITZ!OS 7 |
|
||||
| rollershutter | Rollershutter | Rollershutter control and status. Accepts UP/DOWN/STOP commands and the opening level in percent. States the opening level in percent. | HAN-FUN blind (e.g. Rolltron DECT 1213) - FRITZ!OS 7 |
|
||||
|
||||