[ecowatt] Add support for API version 5 (#15953)
A new thing parameter to define the API version has been added. Its default value is 4 for backward compatibility even if this version is now deprecated. The documentation explains what to do to switch from a version to another. Signed-off-by: Laurent Garnier <lg.hc@free.fr>
This commit is contained in:
@@ -17,11 +17,16 @@ You have to add the thing manually.
|
||||
|
||||
You must create an account and an application on the RTE portal to obtain the OAuth2 credentials required to access the API.
|
||||
|
||||
1. Open this [page](https://data.rte-france.com/catalog/-/api/consumption/Ecowatt/v4.0), find the "Ecowatt" tile and click on the "Abonnez-vous à l'API" button.
|
||||
1. Open this [page](https://data.rte-france.com/catalog/-/api/consumption/Ecowatt/v5.0), find the "Ecowatt" tile and click on the "Abonnez-vous à l'API" button.
|
||||
1. Create an account by following the instructions (you will receive an email to validate your new account).
|
||||
1. Once logged in, create an application by entering a name (for example "openHAB Integration"), choosing "Web Server" as type, entering any description of your choice and finally clicking on the "Valider" button.
|
||||
1. You will then see your application details, in particular the "ID client" and "ID Secret" information which you will need later to set up your binding thing.
|
||||
|
||||
Note that you are subscribed to a particular version of the API.
|
||||
When a new version of the API is released, you will have to subscribe to this new version and create a new application.
|
||||
You will then get new information "ID client" and "ID Secret" and you will have to update your thing configuration in openHAB.
|
||||
After changing version, you will have to wait for your authentication token to be renewed (max 2 hours) to get a successful response from the API.
|
||||
|
||||
## Binding Configuration
|
||||
|
||||
There are no overall binding configuration settings that need to be set.
|
||||
@@ -29,10 +34,13 @@ All settings are through thing configuration parameters.
|
||||
|
||||
## Thing Configuration
|
||||
|
||||
| Name | Type | Description | Required |
|
||||
|-----------|---------|-----------------------------------------------------------------------|----------|
|
||||
| idClient | text | ID client provided with the application you created in the RTE portal | yes |
|
||||
| idSecret | text | ID secret provided with the application you created in the RTE portal | yes |
|
||||
| Name | Type | Description | Required | Default |
|
||||
|------------|---------|---------------------------------------------------------------------------|----------|---------|
|
||||
| apiVersion | integer | The version of the Ecowatt tile to which you subscribed in the RTE portal | no | 4 |
|
||||
| idClient | text | ID client provided with the application you created in the RTE portal | yes | |
|
||||
| idSecret | text | ID secret provided with the application you created in the RTE portal | yes | |
|
||||
|
||||
Take care to select the API version corresponding to the one to which you subscribed in the RTE portal.
|
||||
|
||||
## Channels
|
||||
|
||||
@@ -42,14 +50,14 @@ All channels are read-only.
|
||||
|-------------------|--------|------------------------------------------------------------------|
|
||||
| todaySignal | Number | The signal relating to the forecast consumption level for today. Values are 1 for normal consumption (green), 2 for strained electrical system (orange) and 3 for very strained electrical system (red). |
|
||||
| tomorrowSignal | Number | The signal relating to the forecast consumption level for tomorrow. Values are 1 for normal consumption (green), 2 for strained electrical system (orange) and 3 for very strained electrical system (red). |
|
||||
| currentHourSignal | Number | The signal relating to the forecast consumption level for the current hour. Values are 1 for normal consumption (green), 2 for strained electrical system (orange) and 3 for very strained electrical system (red). |
|
||||
| currentHourSignal | Number | The signal relating to the forecast consumption level for the current hour. Values are 0 for normal consumption (green) and carbon-free production, 1 for normal consumption (green), 2 for strained electrical system (orange) and 3 for very strained electrical system (red). |
|
||||
|
||||
## Full Example
|
||||
|
||||
example.things:
|
||||
|
||||
```java
|
||||
Thing ecowatt:signals:signals "Ecowatt Signals" [ idClient="xxxxx", idSecret="yyyyy"]
|
||||
Thing ecowatt:signals:signals "Ecowatt Signals" [ apiVersion=4, idClient="xxxxx", idSecret="yyyyy"]
|
||||
```
|
||||
|
||||
example.items:
|
||||
|
||||
Reference in New Issue
Block a user