[lcn] doc: make dimmer output resolution more clearer, fix i18n error (#9162)

Signed-off-by: Fabian Wolter <github@fabian-wolter.de>
This commit is contained in:
Fabian Wolter 2020-11-29 05:27:16 +01:00 committed by GitHub
parent ad202edefa
commit a2bcb2ec7a
No known key found for this signature in database
GPG Key ID: 4AEE18F83AFDEB23
3 changed files with 9 additions and 8 deletions

View File

@ -59,15 +59,16 @@ Thing Type ID: `pckGateway`
| `mode` | Dimmer resolution: `native50` or `native200` See below. | String | Yes |
| `timeoutMs` | Period after which an LCN command is resent, when no acknowledge has been received (in ms) (default: 3500) | Integer | Yes |
> **IMPORTANT:** You need to configure the dimmer output resolution. This setting is valid for the **whole** LCN bus.<br />
The setting is either 0-50 steps or 0-200 steps.
It **has to be the same** as in the parameterizing software **LCN-PRO** under Options/Settings/Expert Settings.
See the following screenshot.
> **ATTENTION:** You must set the correct dimmer output resolution in the PCK Gateway Thing (`mode`)!
This setting is crucial, and valid for the **whole** LCN bus.<br />
It is either 0-50 steps or 0-200 steps.
It has to be the same as in the parameterizing software LCN-PRO under Options/Settings/Expert Settings.<br />
**When using a wrong dimmer output setting, dimming the outputs will result in unintended behavior!**
Please see the following LCN-PRO screenshot to determine the dimmer output resolution for the LCN bus:
![LCN-PRO screenshot, showing the 50 or 200 steps for the dimmer outputs](doc/LCN-PRO_output_steps.png)
When using a wrong dimmer output setting, dimming the outputs will result in unintended behavior.
### Thing: LCN Group
LCN modules can be assigned to groups with the programming software *LCN-PRO*.

View File

@ -30,7 +30,7 @@
</parameter>
<parameter name="mode" type="text" required="true">
<label>Dimming Mode</label>
<description><![CDATA[<strong>IMPORTANT:</strong> Dimming range of all modules. Must be the same value as configured in LCN-PRO (Options/Settings/Expert Settings). If you <em>only</em> have modules with firmware newer than Feb. 2013, you probably want to choose 0 - 200.]]></description>
<description><![CDATA[<strong>ATTENTION:</strong> Dimming range of all modules. Must be the same value as configured in LCN-PRO (Options/Settings/Expert Settings). If you <em>only</em> have modules with firmware newer than Feb. 2013, you probably want to choose 0 - 200.]]></description>
<default>native200</default>
<options>
<option value="native50">0 - 50</option>

View File

@ -15,7 +15,7 @@ thing-type.config.lcn.pckGateway.hostname.description = Hostname oder die IP-Adr
thing-type.config.lcn.pckGateway.port.description = Netzwerk-Port auf dem der PCK-Koppler läuft
thing-type.config.lcn.pckGateway.username.description = Benutzername vom PCK-Koppler
thing-type.config.lcn.pckGateway.password.description = Login-Passwort vom PCK-Koppler
thing-type.config.lcn.pckGateway.mode.description = <strong>WICHTIG:</strong> Der Dimmbereich von allen LCN-Modulen. Muss der gleiche Wert, wie in LCN-PRO sein (Optionen/Einstellungen/Experteneinstellungen). Wenn <em>nur</em> Module älter als 2013 im Bus vorhanden sind, muss hier wahrscheinlich 0 - 200 ausgewählt werden.
thing-type.config.lcn.pckGateway.mode.description = <strong>ACHTUNG:</strong> Der Dimmbereich von allen LCN-Modulen. Muss der gleiche Wert, wie in LCN-PRO sein (Optionen/Einstellungen/Experteneinstellungen). Wenn <em>nur</em> Module neuer als 2013 im Bus vorhanden sind, muss hier wahrscheinlich 0 - 200 ausgewählt werden.
thing-type.config.lcn.pckGateway.timeoutMs.description = Zeit nach der eine PCK-Nachricht erneut gesendet wird, wenn vom Modul keine positive Quittung empfangen wurde.
thing-type.config.lcn.module.moduleId.label = Modul-ID