[knx] Refactoring of KnxCoreTypeMapper and UOM Support (#14534)
* [knx] Refactoring, add basic support for UOM Preparation for refactoring KnxCoreTypeMapper. Carryover from smarthomej/addons#107. Merge UOM implementations. * [knx] Adapt tests DPT strings for QuantityType now strip off a tailing .0 when decimals are converted. * [knx] Refactoring Use pattern matching with instanceof operator (new Java17 feature). * [knx] Refactoring, performance improvements Introduce KNXChannel class. Carryover from smarthomej/addons#114. * [knx] Add warning for incompatible DPT type Configuring incompatible DPT/channel combinations (e.g. DPT 1.005 (alarm) on Contact channels or DPT 1.019 (windows/door) on Switch channels) is not allowed but was silently ignored. This PR adds a warning in case incompatible configurations are detected. Carryover from smarthomej/addons#203. * [knx] Add full support for UoM Replace UoM handling with the implementation from smarthome/j. Carryover from smarthomej/addons#206. * [knx] Refactor KNXCoreTypeMapper, add RGBW and xyY Carryover from smarthomej/addons#208. * [knx] Fix RGB conversion Carryover from smarthomej/addons#219. * [knx] Remove workarounds obsoleted by Calimero 2.5 Carryover from smarthomej/addons#226. * [knx] Add parameter for disabling incoming UoM Carryover from smarthomej/addons#230. * [knx] Fix fallback to DecimalType in number conversion Carryover from smarthomej/addons#279. * [knx] Fix DPT 251.600 decoding Carryover from smarthomej/addons#349. * [knx] Fix UoM handling for special types * [knx] Add test for KNXChannelFactory * [knx] Update CODEOWNERS for knx * [knx] Default conversion for DPT 5.001 and 6.001 * [knx] Fix write blocked forever after read from bus Carryover from smarthomej/addons#299 and smarthomej/addons#330. * [knx] Use new class ColorUtil from core for HSB conversion Also-by: Jan N. Klug <github@klug.nrw> Signed-off-by: Holger Friedrich <mail@holger-friedrich.de>
This commit is contained in:
@@ -9,6 +9,18 @@ The KNX binding then can communicate directly with this gateway.
|
||||
Alternatively, a PC running [KNXD](https://github.com/knxd/knxd) (free open source component software) can be put in between which then acts as a broker allowing multiple client to connect to the same gateway.
|
||||
Since the protocol is identical, the KNX binding can also communicate with it transparently.
|
||||
|
||||
***Attention:*** With the introduction of Unit of Measurement (UoM) support, some data types have changed (see `number` channel below):
|
||||
|
||||
- Data type for DPT 5.001 (Percent 8bit, 0 -> 100%) has changed from `PercentType` to `QuantityType`for `number` channels (`dimmer`, `color`, `rollershutter` channels stay with `PercentType`).
|
||||
- Data type for DPT 5.004 (Percent 8bit, 0 -> 255%) has changed from `PercentType` to `QuantityType`.
|
||||
- Data type for DPT 6.001 (Percent 8bit -128 -> 127%) has changed from `PercentType` to `QuantityType`.
|
||||
- Data type for DPT 9.007 (Humidity) has changed from `PercentType` to `QuantityType`.
|
||||
|
||||
Rules that check for or compare states and transformations that expect a raw value might need adjustments.
|
||||
If you run into trouble with that and need some time, you can disable UoM support on binding level via the `disableUoM` parameter.
|
||||
UoM are enabled by default and need to be disabled manually.
|
||||
A new setting is activated immediately without restart.
|
||||
|
||||
## Supported Things
|
||||
|
||||
The KNX binding supports two types of bridges, and one type of things to access the KNX bus.
|
||||
@@ -16,7 +28,8 @@ There is an _ip_ bridge to connect to KNX IP Gateways, and a _serial_ bridge for
|
||||
|
||||
## Bridges
|
||||
|
||||
The following two bridge types are supported. Bridges don't have channels on their own.
|
||||
The following two bridge types are supported.
|
||||
Bridges don't have channels on their own.
|
||||
|
||||
### IP Gateway
|
||||
|
||||
@@ -76,45 +89,30 @@ All channels of a device share one configuration parameter defined on device lev
|
||||
All readable group addresses are queried by openHAB during startup.
|
||||
If readInterval is not specified or set to 0, no further periodic reading will be triggered (default: 0).
|
||||
|
||||
#### Standard Channel Types
|
||||
#### Channel Types
|
||||
|
||||
Standard channels are used most of the time.
|
||||
They are used in the common case where the physical state is owned by a device within the KNX bus, e.g. by a switch actuator who "knows" whether the light is turned on or off, or by a temperature sensor which reports the room temperature regularly.
|
||||
|
||||
Note: After changing the DPT of already existing Channels, openHAB needs to be restarted for the changes to become effective.
|
||||
Control channel types (suffix `-control`) are used for cases where the KNX bus does not own the physical state of a device.
|
||||
This could be the case if e.g. a lamp from another binding should be controlled by a KNX wall switch.
|
||||
When a `GroupValueRead` telegram is sent from the KNX bus to a *-control Channel, the bridge responds with a `GroupValueResponse` telegram to the KNX bus.
|
||||
|
||||
##### Channel Type "switch"
|
||||
|
||||
| Parameter | Description | Default DPT |
|
||||
|-----------|-------------------------------------|-------------|
|
||||
| ga | Group address for the binary switch | 1.001 |
|
||||
|
||||
##### Channel Type "dimmer"
|
||||
##### Channel Type `color`, `color-control`
|
||||
|
||||
| Parameter | Description | Default DPT |
|
||||
|------------------|----------------------------------------|-------------|
|
||||
| hsb | Group address for the color | 232.600 |
|
||||
| switch | Group address for the binary switch | 1.001 |
|
||||
| position | Group address of the absolute position | 5.001 |
|
||||
| increaseDecrease | Group address for relative movement | 3.007 |
|
||||
| position | Group address brightness | 5.001 |
|
||||
| increaseDecrease | Group address for relative brightness | 3.007 |
|
||||
|
||||
##### Channel Type "color"
|
||||
The `hsb` address supports DPT 242.600 and 251.600.
|
||||
|
||||
| Parameter | Description | Default DPT |
|
||||
|------------------|----------------------------------------|-------------|
|
||||
| hsb | Group address for color | 232.600 |
|
||||
| switch | Group address for the binary switch | 1.001 |
|
||||
| position | Group address of the absolute position | 5.001 |
|
||||
| increaseDecrease | Group address for relative movement | 3.007 |
|
||||
Some RGB/RGBW products (e.g. MDT) support HSB values for DPT 232.600 instead of RGB.
|
||||
This is supported as "vendor-specific DPT" with a value of 232.60000.
|
||||
|
||||
##### Channel Type "rollershutter"
|
||||
|
||||
| Parameter | Description | Default DPT |
|
||||
|-----------|-----------------------------------------|-------------|
|
||||
| upDown | Group address for relative movement | 1.008 |
|
||||
| stopMove | Group address for stopping | 1.010 |
|
||||
| position | Group address for the absolute position | 5.001 |
|
||||
|
||||
##### Channel Type "contact"
|
||||
##### Channel Type `contact`, `contact-control`
|
||||
|
||||
| Parameter | Description | Default DPT |
|
||||
|-----------|---------------|-------------|
|
||||
@@ -123,32 +121,63 @@ Note: After changing the DPT of already existing Channels, openHAB needs to be r
|
||||
*Attention:* Due to a bug in the original implementation, the states for DPT 1.009 are inverted (i.e. `1` is mapped to `OPEN` instead of `CLOSE`).
|
||||
A change would break all existing installations and is therefore not implemented.
|
||||
|
||||
##### Channel Type "number"
|
||||
|
||||
| Parameter | Description | Default DPT |
|
||||
|-----------|---------------|-------------|
|
||||
| ga | Group address | 9.001 |
|
||||
|
||||
Note: Using the Units Of Measurement feature of openHAB (Quantitytype) requires that the DPT value is set correctly.
|
||||
Automatic type conversion will be applied if required.
|
||||
|
||||
##### Channel Type "string"
|
||||
|
||||
| Parameter | Description | Default DPT |
|
||||
|-----------|---------------|-------------|
|
||||
| ga | Group address | 16.001 |
|
||||
|
||||
##### Channel Type "datetime"
|
||||
##### Channel Type `datetime`, `datetime-control`
|
||||
|
||||
| Parameter | Description | Default DPT |
|
||||
|-----------|---------------|-------------|
|
||||
| ga | Group address | 19.001 |
|
||||
|
||||
##### Channel Type `dimmer`, `dimmer-control`
|
||||
|
||||
| Parameter | Description | Default DPT |
|
||||
|------------------|----------------------------------------|-------------|
|
||||
| switch | Group address for the binary switch | 1.001 |
|
||||
| position | Group address of the absolute position | 5.001 |
|
||||
| increaseDecrease | Group address for relative movement | 3.007 |
|
||||
|
||||
##### Channel Type `number`, `number-control`
|
||||
|
||||
| Parameter | Description | Default DPT |
|
||||
|-----------|---------------|-------------|
|
||||
| ga | Group address | 9.001 |
|
||||
|
||||
Note: The `number` channel has full support for Units Of Measurement (UoM).
|
||||
|
||||
Using the UoM feature of openHAB (QuantityType) requires that the DPT value is set correctly.
|
||||
Automatic type conversion will be applied if required.
|
||||
|
||||
Incoming values from the KNX bus are converted to values with units (e.g. `23 °C`).
|
||||
If the channel is linked to the correct item-type (`Number:Temperature` in this case) the display unit can be controlled by item metadata (e.g. `%.1f °F` for 1 digit of precision in Fahrenheit).
|
||||
The unit is stripped if the channel is linked to a plain number item (type `Number`).
|
||||
|
||||
Outgoing values with unit are first converted to the unit associated with the DPT (e.g. a value of `10 °F` is converted to `-8.33 °C` if the channel has DPT 9.001).
|
||||
Values from plain number channels are sent as-is (without any conversion).
|
||||
|
||||
##### Channel Type `rollershutter`, `rollershutter-control`
|
||||
|
||||
| Parameter | Description | Default DPT |
|
||||
|-----------|-----------------------------------------|-------------|
|
||||
| upDown | Group address for relative movement | 1.008 |
|
||||
| stopMove | Group address for stopping | 1.010 |
|
||||
| position | Group address for the absolute position | 5.001 |
|
||||
|
||||
##### Channel Type `string`, `string-control`
|
||||
|
||||
| Parameter | Description | Default DPT |
|
||||
|-----------|---------------|-------------|
|
||||
| ga | Group address | 16.001 |
|
||||
|
||||
##### Channel Type `switch`, `switch-control`
|
||||
|
||||
| Parameter | Description | Default DPT |
|
||||
|-----------|-------------------------------------|-------------|
|
||||
| ga | Group address for the binary switch | 1.001 |
|
||||
|
||||
#### Control Channel Types
|
||||
|
||||
In contrast to the standard channels above, the control channel types are used for cases where the KNX bus does not own the physical state of a device.
|
||||
This could for example be the case if a lamp from another binding should be controlled by a KNX wall switch.
|
||||
If from the KNX bus a `GroupValueRead` telegram is sent to a *-control Channel, the bridge responds with a `GroupValueResponse` telegram to the KNX bus.
|
||||
When a `GroupValueRead` telegram is sent from the KNX bus to a *-control Channel, the bridge responds with a `GroupValueResponse` telegram to the KNX bus.
|
||||
|
||||
##### Channel Type "switch-control"
|
||||
|
||||
@@ -165,14 +194,6 @@ If from the KNX bus a `GroupValueRead` telegram is sent to a *-control Channel,
|
||||
| increaseDecrease | Group address for relative movement | 3.007 |
|
||||
| frequency | Increase/Decrease frequency in milliseconds in case the binding should handle that (0 if the KNX device sends the commands repeatedly itself) | 0 |
|
||||
|
||||
##### Channel Type "color-control"
|
||||
|
||||
| Parameter | Description | Default DPT |
|
||||
|------------------|----------------------------------------|-------------|
|
||||
| hsb | Group address for color | 232.600 |
|
||||
| switch | Group address for the binary switch | 1.001 |
|
||||
| position | Group address of the absolute position | 5.001 |
|
||||
| increaseDecrease | Group address for relative movement | 3.007 |
|
||||
|
||||
##### Channel Type "rollershutter-control"
|
||||
|
||||
@@ -197,6 +218,8 @@ A change would break all existing installations and is therefore not implemented
|
||||
|-----------|---------------|-------------|
|
||||
| ga | Group address | 9.001 |
|
||||
|
||||
For UoM support see the explanations of the `number` channel.
|
||||
|
||||
##### Channel Type "string-control"
|
||||
|
||||
| Parameter | Description | Default DPT |
|
||||
@@ -340,14 +363,14 @@ Bridge knx:ip:bridge [
|
||||
knx.items:
|
||||
|
||||
```java
|
||||
Switch demoSwitch "Light [%s]" <light> { channel="knx:device:bridge:generic:demoSwitch" }
|
||||
Color demoColorLight "Color [%s]" <light> { channel="knx:device:bridge:generic:demoColorLight" }
|
||||
Dimmer demoDimmer "Dimmer [%d %%]" <light> { channel="knx:device:bridge:generic:demoDimmer" }
|
||||
Rollershutter demoRollershutter "Shade [%d %%]" <rollershutter> { channel="knx:device:bridge:generic:demoRollershutter" }
|
||||
Contact demoContact "Front Door [%s]" <frontdoor> { channel="knx:device:bridge:generic:demoContact" }
|
||||
Number demoTemperature "Temperature [%.1f °C]" <temperature> { channel="knx:device:bridge:generic:demoTemperature" }
|
||||
String demoString "Message of the day [%s]" { channel="knx:device:bridge:generic:demoString" }
|
||||
DateTime demoDatetime "Alarm [%1$tH:%1$tM]" { channel="knx:device:bridge:generic:demoDatetime" }
|
||||
Switch demoSwitch "Light [%s]" <light> { channel="knx:device:bridge:generic:demoSwitch" }
|
||||
Color demoColorLight "Color [%s]" <light> { channel="knx:device:bridge:generic:demoColorLight" }
|
||||
Dimmer demoDimmer "Dimmer [%d %%]" <light> { channel="knx:device:bridge:generic:demoDimmer" }
|
||||
Rollershutter demoRollershutter "Shade [%d %%]" <rollershutter> { channel="knx:device:bridge:generic:demoRollershutter" }
|
||||
Contact demoContact "Front Door [%s]" <frontdoor> { channel="knx:device:bridge:generic:demoContact" }
|
||||
Number:Temperature demoTemperature "Temperature [%.1f °C]" <temperature> { channel="knx:device:bridge:generic:demoTemperature" }
|
||||
String demoString "Message of the day [%s]" { channel="knx:device:bridge:generic:demoString" }
|
||||
DateTime demoDatetime "Alarm [%1$tH:%1$tM]" { channel="knx:device:bridge:generic:demoDatetime" }
|
||||
```
|
||||
|
||||
knx.sitemap:
|
||||
|
||||
Reference in New Issue