[openwebnet] Add support for Dry Contact and IR interfaces for WHO=25 (#11747)
* [openwebnet] updated where parameter labels Signed-off-by: Massimo Valla <mvcode00@gmail.com> * [openwebnet] added support for DryContact/IR interfaces Signed-off-by: Massimo Valla <mvcode00@gmail.com> * [openwebnet] updated README Signed-off-by: Massimo Valla <mvcode00@gmail.com> * [openwebnet] checkstyle Signed-off-by: Massimo Valla <mvcode00@gmail.com>
This commit is contained in:
@@ -45,6 +45,7 @@ The following Things and OpenWebNet `WHOs` are supported:
|
||||
| Automation | `2` | `bus_automation` | BUS roller shutters, with position feedback and auto-calibration | Successfully tested: LN4672M2 |
|
||||
| Temperature Control | `4` | `bus_thermo_zone`, `bus_thermo_sensor` | Thermo zones management and temperature sensors (probes). NOTE Central Units (4 or 99 zones) are not fully supported yet. See [Channels - Thermo](#configuring-thermo) for more details. | Successfully tested: H/LN4691, HS4692, KG4691; thermo sensors: L/N/NT4577 + 3455 |
|
||||
| CEN & CEN+ Scenarios | `15` & `25` | `bus_cen_scenario_control`, `bus_cenplus_scenario_control` | CEN/CEN+ scenarios events and virtual activation | Successfully tested: scenario buttons: HC/HD/HS/L/N/NT4680 |
|
||||
| Dry Contact and IR Interfaces | `25` | `bus_dry_contact_ir` | Dry Contacts and IR Interfaces | Successfully tested: contact interfaces F428 and 3477; IR sensors: HC/HD/HS/L/N/NT4610 |
|
||||
| Energy Management | `18` | `bus_energy_meter` | Energy Management | Successfully tested: F520, F521 |
|
||||
|
||||
### For ZigBee (Radio)
|
||||
@@ -123,12 +124,13 @@ Devices can be discovered automatically using an Inbox Scan after a gateway has
|
||||
For any manually added device, you must configure:
|
||||
|
||||
- the associated gateway (`Parent Bridge` menu)
|
||||
- the `where` config parameter (`OpenWebNet Device Address`):
|
||||
- the `where` configuration parameter (`OpenWebNet Address`):
|
||||
- example for BUS/SCS:
|
||||
- light device with WHERE address Point to Point `A=2 PL=4` --> `where="24"`
|
||||
- light device with WHERE address Point to Point `A=03 PL=11` on local bus --> `where="0311#4#01"`
|
||||
- CEN scenario with WHERE address Point to Point `A=05 PL=12` --> `where="0512"`
|
||||
- CEN+ configured scenario `5`: add a `2` before --> `where="25"`
|
||||
- Dry Contact or IR Interface `99`: add a `3` before --> `where="399"`
|
||||
- example for ZigBee devices: `where=765432101#9`. The ID of the device (ADDR part) is usually written in hexadecimal on the device itself, for example `ID 0074CBB1`: convert to decimal (`7654321`) and add `01#9` at the end to obtain `where=765432101#9`. For 2-unit switch devices (`zb_on_off_switch2u`), last part should be `00#9`.
|
||||
|
||||
|
||||
@@ -138,13 +140,13 @@ In BTicino MyHOME Thermoregulation (WHO=4) each **zone** has associated a thermo
|
||||
|
||||
Thermo zones can be configured defining a `bus_thermo_zone` Thing for each zone with the following parameters:
|
||||
|
||||
- the `where` config parameter (`OpenWebNet Device Address`):
|
||||
- the `where` configuration parameter (`OpenWebNet Address`):
|
||||
- example BUS/SCS Thermo zone `1` --> `where="1"`
|
||||
- the `standAlone` config parameter (`boolean`, default: `true`): identifies if the zone is managed or not by a Central Unit (4 or 99 zones). `standAlone=true` means no Central Unit is present in the system.
|
||||
- the `standAlone` configuration parameter (`boolean`, default: `true`): identifies if the zone is managed or not by a Central Unit (4 or 99 zones). `standAlone=true` means no Central Unit is present in the system.
|
||||
|
||||
Temperature sensors can be configured defining a `bus_thermo_sensor` Thing with the following parameters:
|
||||
|
||||
- the `where` config parameter (`OpenWebNet Device Address`):
|
||||
- the `where` configuration parameter (`OpenWebNet Address`):
|
||||
- example sensor `5` of external zone `00` --> `where="500"`
|
||||
- example: slave sensor `3` of zone `2` --> `where="302"`
|
||||
|
||||
@@ -155,7 +157,7 @@ Systems with Central Units (4 or 99 zones) are not fully supported yet.
|
||||
|
||||
## Channels
|
||||
|
||||
### Lighting, Automation, Power meter and CEN/CEN+ Scenario Events channels
|
||||
### Lighting, Automation, Power meter, CEN/CEN+ Scenario Events and Dry Contact / IR Interfaces channels
|
||||
|
||||
| Channel Type ID (channel ID) | Applies to Thing Type IDs | Item Type | Description | Read/Write |
|
||||
| ---------------------------------------- | ------------------------------------------------------------- | ------------- | ----------------------------------------------------- | :--------: |
|
||||
@@ -163,6 +165,7 @@ Systems with Central Units (4 or 99 zones) are not fully supported yet.
|
||||
| `brightness` | `bus_dimmer`, `zb_dimmer` | Dimmer | To adjust the brightness value (Percent, `ON`, `OFF`) | R/W |
|
||||
| `shutter` | `bus_automation` | Rollershutter | To activate roller shutters (`UP`, `DOWN`, `STOP`, Percent - [see Shutter position](#shutter-position)) | R/W |
|
||||
| `button#X` | `bus_cen_scenario_control`, `bus_cenplus_scenario_control` | String | Trigger channel for CEN/CEN+ scenario events [see possible values](#cen-cen-channels) | R (TRIGGER) |
|
||||
| `sensor` | `bus_dry_contact_ir` | Switch | Indicates if a Dry Contact Interface is `ON`/`OFF`, or if a IR Sensor is detecting movement (`ON`), or not (`OFF`) | R |
|
||||
| `power` | `bus_energy_meter` | Number:Power | The current active power usage from Energy Meter | R |
|
||||
|
||||
### Thermo channels
|
||||
@@ -233,6 +236,7 @@ Bridge openwebnet:bus_gateway:mybridge "MyHOMEServer1" [ host="192.168.1.35", pa
|
||||
bus_thermo_sensor EXT_tempsensor "External Temperature" [ where="500"]
|
||||
bus_cen_scenario_control LR_CEN_scenario "Living Room CEN" [ where="51", buttons="4,3,8"]
|
||||
bus_cenplus_scenario_control LR_CENplus_scenario "Living Room CEN+" [ where="212", buttons="1,5,18" ]
|
||||
bus_dry_contact_ir LR_IR_sensor "Living Room IR Sensor" [ where="399" ]
|
||||
}
|
||||
```
|
||||
|
||||
@@ -275,8 +279,9 @@ String iLR_zone_cv "Conditioning valves" (g
|
||||
|
||||
Number:Temperature iEXT_temp "Temperature [%.1f %unit%]" (gExternal) { channel="openwebnet:bus_thermo_sensor:mybridge:EXT_tempsensor:temperature" }
|
||||
|
||||
String iCENPlusProxyItem "CEN+ Proxy Item"
|
||||
String iCENPlusProxyItem "CEN+ Proxy Item"
|
||||
|
||||
Switch iLR_IR_sensor "Sensor" { channel="openwebnet:bus_dry_contact_ir:mybridge:LR_IR_sensor:sensor" }
|
||||
|
||||
```
|
||||
|
||||
@@ -299,6 +304,7 @@ sitemap openwebnet label="OpenWebNet Binding Example Sitemap"
|
||||
Default item=iLR_switch icon="light"
|
||||
Default item=iLR_dimmer icon="light"
|
||||
Default item=iLR_shutter
|
||||
Switch item=iLR_IR_sensor mappings=[ON="Presence", OFF="No Presence"]
|
||||
}
|
||||
|
||||
Frame label="Energy Meters" icon="energy"
|
||||
|
||||