Use core unit classes (#9261)
Add-ons should not depend on tec.uom.se classes but use core unit classes instead so they are less impacted when this library is replaced or upgraded. Signed-off-by: Wouter Born <github@maindrain.net>
This commit is contained in:
@@ -43,14 +43,13 @@ import org.openhab.binding.shelly.internal.api.ShellyApiJsonDTO.ShellyStatusRela
|
||||
import org.openhab.binding.shelly.internal.api.ShellyApiJsonDTO.ShellyStatusSensor;
|
||||
import org.openhab.binding.shelly.internal.config.ShellyThingConfiguration;
|
||||
import org.openhab.core.library.unit.ImperialUnits;
|
||||
import org.openhab.core.library.unit.SIUnits;
|
||||
import org.slf4j.Logger;
|
||||
import org.slf4j.LoggerFactory;
|
||||
|
||||
import com.google.gson.Gson;
|
||||
import com.google.gson.JsonSyntaxException;
|
||||
|
||||
import tec.uom.se.unit.Units;
|
||||
|
||||
/**
|
||||
* {@link ShellyHttpApi} wraps the Shelly REST API and provides various low level function to access the device api (not
|
||||
* cloud api).
|
||||
@@ -187,10 +186,10 @@ public class ShellyHttpApi {
|
||||
if (profile.isSense) {
|
||||
// complete reported data, map C to F or vice versa: C=(F - 32) * 0.5556;
|
||||
status.tmp.tC = status.tmp.units.equals(SHELLY_TEMP_CELSIUS) ? status.tmp.value
|
||||
: ImperialUnits.FAHRENHEIT.getConverterTo(Units.CELSIUS).convert(getDouble(status.tmp.value))
|
||||
: ImperialUnits.FAHRENHEIT.getConverterTo(SIUnits.CELSIUS).convert(getDouble(status.tmp.value))
|
||||
.doubleValue();
|
||||
status.tmp.tF = status.tmp.units.equals(SHELLY_TEMP_FAHRENHEIT) ? status.tmp.value
|
||||
: Units.CELSIUS.getConverterTo(ImperialUnits.FAHRENHEIT).convert(getDouble(status.tmp.value))
|
||||
: SIUnits.CELSIUS.getConverterTo(ImperialUnits.FAHRENHEIT).convert(getDouble(status.tmp.value))
|
||||
.doubleValue();
|
||||
}
|
||||
if ((status.charger == null) && (status.externalPower != null)) {
|
||||
|
||||
@@ -33,8 +33,6 @@ import org.openhab.core.types.State;
|
||||
import org.slf4j.Logger;
|
||||
import org.slf4j.LoggerFactory;
|
||||
|
||||
import tec.uom.se.unit.Units;
|
||||
|
||||
/**
|
||||
* The {@link ShellyCoIoTVersion1} implements the parsing for CoIoT version 1
|
||||
*
|
||||
@@ -84,7 +82,7 @@ public class ShellyCoIoTVersion1 extends ShellyCoIoTProtocol implements ShellyCo
|
||||
case "temperature": // Sensor Temp
|
||||
if (getString(getProfile().settings.temperatureUnits)
|
||||
.equalsIgnoreCase(SHELLY_TEMP_FAHRENHEIT)) {
|
||||
value = ImperialUnits.FAHRENHEIT.getConverterTo(Units.CELSIUS).convert(getDouble(s.value))
|
||||
value = ImperialUnits.FAHRENHEIT.getConverterTo(SIUnits.CELSIUS).convert(getDouble(s.value))
|
||||
.doubleValue();
|
||||
}
|
||||
updateChannel(updates, CHANNEL_GROUP_SENSOR, CHANNEL_SENSOR_TEMP,
|
||||
|
||||
@@ -31,8 +31,6 @@ import org.openhab.core.library.unit.ImperialUnits;
|
||||
import org.openhab.core.library.unit.SIUnits;
|
||||
import org.openhab.core.library.unit.SmartHomeUnits;
|
||||
|
||||
import tec.uom.se.unit.Units;
|
||||
|
||||
/***
|
||||
* The{@link ShellyComponents} implements updates for supplemental components
|
||||
* Meter will be used by Relay + Light; Sensor is part of H&T, Flood, Door Window, Sense
|
||||
@@ -276,7 +274,7 @@ public class ShellyComponents {
|
||||
: getDouble(sdata.tmp.tF);
|
||||
if (getString(sdata.tmp.units).toUpperCase().equals(SHELLY_TEMP_FAHRENHEIT)) {
|
||||
// convert Fahrenheit to Celsius
|
||||
temp = ImperialUnits.FAHRENHEIT.getConverterTo(Units.CELSIUS).convert(temp).doubleValue();
|
||||
temp = ImperialUnits.FAHRENHEIT.getConverterTo(SIUnits.CELSIUS).convert(temp).doubleValue();
|
||||
}
|
||||
updated |= thingHandler.updateChannel(CHANNEL_GROUP_SENSOR, CHANNEL_SENSOR_TEMP,
|
||||
toQuantityType(temp.doubleValue(), DIGITS_TEMP, SIUnits.CELSIUS));
|
||||
|
||||