[fronius] Added Ohmpilot thing and channel realpowersum for thing meter (#11835)
* Added support for fronius ohmpilot and added smart meter power sum. Signed-off-by: urmet0 <hannes.spenger@gmail.com>
This commit is contained in:
@@ -10,7 +10,9 @@ It supports Fronius inverters and Fronius Smart Meter. Tested with a Fronius Sym
|
||||
| --------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
|
||||
| `bridge` | The Bridge |
|
||||
| `powerinverter` | Fronius Galvo, Symo and other Fronius inverters in combination with the Fronius Datamanager 1.0 / 2.0 or Fronius Datalogger. You can add multiple inverters that depend on the same datalogger with different device ids. (Default 1) |
|
||||
| `meter` | Fronius Smart Meter. You can add multiple smart meters with different device ids. (The default id = 0) |
|
||||
| `meter` | Fronius Smart Meter. You can add multiple smart meters with different device ids. (The default id = 0)
|
||||
| `ohmpilot` | Fronius Ohmpilot. (The default id = 0)
|
||||
|
||||
|
||||
## Discovery
|
||||
|
||||
@@ -18,7 +20,7 @@ There is no discovery implemented. You have to create your things manually and s
|
||||
|
||||
## Binding Configuration
|
||||
|
||||
The binding has no configuration options, all configuration is done at `bridge`, `powerinverter` or `meter` level.
|
||||
The binding has no configuration options, all configuration is done at `bridge`, `powerinverter`, `meter` or `ohmpilot` level.
|
||||
|
||||
## Thing Configuration
|
||||
|
||||
@@ -41,6 +43,12 @@ The binding has no configuration options, all configuration is done at `bridge`,
|
||||
| ---------- | ----------------------------------------------- |
|
||||
| `deviceId` | The identifier of your smart meter (Default: 0) |
|
||||
|
||||
### Ohmpilot Thing Configuration
|
||||
|
||||
| Parameter | Description |
|
||||
| ---------- | ----------------------------------------------- |
|
||||
| `deviceId` | The identifier of your ohmpilot (Default: 0) |
|
||||
|
||||
## Channels
|
||||
|
||||
### Channels for `powerinverter` Thing
|
||||
@@ -77,6 +85,7 @@ The binding has no configuration options, all configuration is done at `bridge`,
|
||||
| `powerrealphase1` | Number:Power | Real Power on Phase 1 |
|
||||
| `powerrealphase2` | Number:Power | Real Power on Phase 2 |
|
||||
| `powerrealphase3` | Number:Power | Real Power on Phase 3 |
|
||||
| `powerrealsum` | Number:Power | Real Power summed up |
|
||||
| `powerfactorphase1` | Number | Power Factor on Phase 1 |
|
||||
| `powerfactorphase2` | Number | Power Factor on Phase 2 |
|
||||
| `powerfactorphase3` | Number | Power Factor on Phase 3 |
|
||||
@@ -85,16 +94,33 @@ The binding has no configuration options, all configuration is done at `bridge`,
|
||||
| |
|
||||
|
||||
|
||||
### Channels for `ohmpilot` Thing
|
||||
|
||||
| Channel ID | Item Type | Description |
|
||||
| ----------------------- | ------------------------ | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ |
|
||||
| `energyrealsumconsumed` | Number:Energy | Real Energy consumed |
|
||||
| `powerrealsum` | Number:Power | Real Power |
|
||||
| `temperaturechannel1` | Number:Temperature | Temperature |
|
||||
| `errorcode` | Number | Device error code |
|
||||
| `statecode` | Number | Device state code<br />`0` up and running <br />`1` keep minimum temperature <br />`2` legionella protection <br />`3` critical fault<br />`4` fault<br />`5` boost mode |
|
||||
| |
|
||||
|
||||
|
||||
## Properties
|
||||
|
||||
The `meter` thing has the following properties:
|
||||
### The `meter` thing has the following properties:
|
||||
|
||||
| Property | Description |
|
||||
| -------- | ------------------------------ |
|
||||
| `model` | The model name of the meter |
|
||||
| `serial` | The serial number of the meter |
|
||||
| `modelId` | The model name of the meter |
|
||||
| `serialNumber` | The serial number of the meter |
|
||||
|
||||
### The `ohmpilot` thing has the following property:
|
||||
|
||||
| Property | Description |
|
||||
| -------- | ------------------------------ |
|
||||
| `modelId` | The model name of the ohmpilot |
|
||||
| `serialNumber` | The serial number of the ohmpilot |
|
||||
|
||||
## Full Example
|
||||
|
||||
@@ -104,6 +130,7 @@ demo.things:
|
||||
Bridge fronius:bridge:mybridge [hostname="192.168.66.148", refreshInterval=5] {
|
||||
Thing powerinverter myinverter [deviceId=1]
|
||||
Thing meter mymeter [deviceId=0]
|
||||
Thing ohmpilot myohmpilot [deviceId=0]
|
||||
}
|
||||
```
|
||||
|
||||
@@ -136,9 +163,17 @@ Number:Voltage Meter_VoltagePhase3 { channel="fronius:meter:mybridge:mymeter:vol
|
||||
Number:Power Meter_PowerPhase1 { channel="fronius:meter:mybridge:mymeter:powerrealphase1" }
|
||||
Number:Power Meter_PowerPhase2 { channel="fronius:meter:mybridge:mymeter:powerrealphase2" }
|
||||
Number:Power Meter_PowerPhase3 { channel="fronius:meter:mybridge:mymeter:powerrealphase3" }
|
||||
Number:Power Meter_PowerSum { channel="fronius:meter:mybridge:mymeter:powerrealsum" }
|
||||
Number Meter_PowerFactorPhase1 { channel="fronius:meter:mybridge:mymeter:powerfactorphase1" }
|
||||
Number Meter_PowerFactorPhase2 { channel="fronius:meter:mybridge:mymeter:powerfactorphase2" }
|
||||
Number Meter_PowerFactorPhase3 { channel="fronius:meter:mybridge:mymeter:powerfactorphase3" }
|
||||
Number:Energy Meter_EnergyConsumed { channel="fronius:meter:mybridge:mymeter:energyrealsumconsumed" }
|
||||
Number:Energy Meter_EnergyProduced { channel="fronius:meter:mybridge:mymeter:energyrealsumproduced" }
|
||||
|
||||
Number:Energy Ohmpilot_EnergyConsumed { channel="fronius:ohmpilot:mybridge:myohmpilot:energyrealsumconsumed" }
|
||||
Number:Power Ohmpilot_PowerSum { channel="fronius:ohmpilot:mybridge:myohmpilot:powerrealsum" }
|
||||
Number:Temperature Ohmpilot_Temperature { channel="fronius:ohmpilot:mybridge:myohmpilot:temperaturechannel1" }
|
||||
Number Ohmpilot_State { channel="fronius:ohmpilot:mybridge:myohmpilot:statecode" }
|
||||
Number Ohmpilot_Errorcode { channel="fronius:ohmpilot:mybridge:myohmpilot:errorcode" }
|
||||
|
||||
```
|
||||
|
||||
Reference in New Issue