Use renamed Units class (#9267)
Signed-off-by: Wouter Born <github@maindrain.net>
This commit is contained in:
@@ -14,7 +14,7 @@ package org.openhab.binding.opensprinkler.internal.handler;
|
||||
|
||||
import static org.openhab.binding.opensprinkler.internal.OpenSprinklerBindingConstants.*;
|
||||
import static org.openhab.core.library.unit.MetricPrefix.MILLI;
|
||||
import static org.openhab.core.library.unit.SmartHomeUnits.PERCENT;
|
||||
import static org.openhab.core.library.unit.Units.PERCENT;
|
||||
|
||||
import javax.measure.quantity.ElectricCurrent;
|
||||
|
||||
@@ -23,7 +23,7 @@ import org.openhab.binding.opensprinkler.internal.api.exception.CommunicationApi
|
||||
import org.openhab.binding.opensprinkler.internal.model.NoCurrentDrawSensorException;
|
||||
import org.openhab.core.library.types.OnOffType;
|
||||
import org.openhab.core.library.types.QuantityType;
|
||||
import org.openhab.core.library.unit.SmartHomeUnits;
|
||||
import org.openhab.core.library.unit.Units;
|
||||
import org.openhab.core.thing.Channel;
|
||||
import org.openhab.core.thing.ChannelUID;
|
||||
import org.openhab.core.thing.Thing;
|
||||
@@ -62,7 +62,7 @@ public class OpenSprinklerDeviceHandler extends OpenSprinklerBaseHandler {
|
||||
break;
|
||||
case SENSOR_CURRENT_DRAW:
|
||||
updateState(channel,
|
||||
new QuantityType<ElectricCurrent>(getApi().currentDraw(), MILLI(SmartHomeUnits.AMPERE)));
|
||||
new QuantityType<ElectricCurrent>(getApi().currentDraw(), MILLI(Units.AMPERE)));
|
||||
break;
|
||||
default:
|
||||
logger.debug("Not updating unknown channel {}", channel);
|
||||
|
||||
@@ -27,7 +27,7 @@ import org.openhab.binding.opensprinkler.internal.api.exception.GeneralApiExcept
|
||||
import org.openhab.binding.opensprinkler.internal.config.OpenSprinklerStationConfig;
|
||||
import org.openhab.core.library.types.OnOffType;
|
||||
import org.openhab.core.library.types.QuantityType;
|
||||
import org.openhab.core.library.unit.SmartHomeUnits;
|
||||
import org.openhab.core.library.unit.Units;
|
||||
import org.openhab.core.thing.Channel;
|
||||
import org.openhab.core.thing.ChannelUID;
|
||||
import org.openhab.core.thing.Thing;
|
||||
@@ -90,7 +90,7 @@ public class OpenSprinklerStationHandler extends OpenSprinklerBaseHandler {
|
||||
return;
|
||||
}
|
||||
QuantityType<?> quantity = (QuantityType<?>) command;
|
||||
this.nextDurationTime = quantity.toUnit(SmartHomeUnits.SECOND).toBigDecimal();
|
||||
this.nextDurationTime = quantity.toUnit(Units.SECOND).toBigDecimal();
|
||||
updateState(channelUID, quantity);
|
||||
}
|
||||
|
||||
@@ -182,7 +182,7 @@ public class OpenSprinklerStationHandler extends OpenSprinklerBaseHandler {
|
||||
+ " for the OpenSprinkler device. Exception received: " + exp);
|
||||
}
|
||||
|
||||
return new QuantityType<>(remainingWaterTime, SmartHomeUnits.SECOND);
|
||||
return new QuantityType<>(remainingWaterTime, Units.SECOND);
|
||||
}
|
||||
|
||||
@Override
|
||||
@@ -203,7 +203,7 @@ public class OpenSprinklerStationHandler extends OpenSprinklerBaseHandler {
|
||||
case NEXT_DURATION:
|
||||
BigDecimal duration = nextDurationValue();
|
||||
if (duration != null) {
|
||||
updateState(channel, new QuantityType<>(duration, SmartHomeUnits.SECOND));
|
||||
updateState(channel, new QuantityType<>(duration, Units.SECOND));
|
||||
}
|
||||
break;
|
||||
case STATION_QUEUED:
|
||||
|
||||
Reference in New Issue
Block a user