[openwebnet] adding support for central unit (#12062)
* - read 'standAlone' flag from thing - send standAlone flag to own4j for setting the temperature on central unit - own4j 0.7.1 required * added localmode and central unit thing * added localOffSet channel to readme.md * added remoteControl, batteryStatus and modeCentralUnit for bus_thermo_cu * added weekly and scenarios to modeCentralUnit * - manual setting of a zone to T temperature (with persistence in central unit) - manual setting of central unit to T temperature (all zones) - set the central unit in OFF mode (all zones) - set central unit in thermal protection (all zones) - set central unit in antifreeze mode (all zones) - weekly program activation command (all zones) - scenario activation command (all zones) * renamed cu's channels name * removed unused channel 'modeCentralUnit" from readme * fix #12298 * - add configuration section (where) for BusThermoCentralUnit - strings ("OK", "KO", "ENABLED", "DISABLED" converted to constants - fix typo Signed-off-by: Conte Andrea <andrea@conte.com> Co-authored-by: M Valla <12682715+mvalla@users.noreply.github.com>
This commit is contained in:
@@ -38,23 +38,23 @@ The following Things and OpenWebNet `WHOs` are supported:
|
||||
|
||||
### For BUS/SCS
|
||||
|
||||
| Category | WHO | Thing Type IDs | Description | Status |
|
||||
| -------------------- | :----------: | :---------------------------------: | ---------------------------------------------------------------- | ---------------- |
|
||||
| Gateway Management | `13` | `bus_gateway` | Any IP gateway supporting OpenWebNet protocol should work (e.g. F454 / MyHOMEServer1 / MH202 / F455 / MH200N, ...) | Successfully tested: F454, MyHOMEServer1, MyHOME_Screen10, MyHOME_Screen3,5, F455, F452, F453AV, MH201, MH202, MH200N. Some connection stability issues/gateway resets reported with MH202 |
|
||||
| Lighting | `1` | `bus_on_off_switch`, `bus_dimmer` | BUS switches and dimmers | Successfully tested: F411/2, F411/4, F411U2, F422, F429. Some discovery issues reported with F429 (DALI Dimmers) |
|
||||
| Automation | `2` | `bus_automation` | BUS roller shutters, with position feedback and auto-calibration | Successfully tested: LN4672M2 |
|
||||
| Temperature Control | `4` | `bus_thermo_zone`, `bus_thermo_sensor` | Thermo zones management and temperature sensors (probes). NOTE Central Units (4 or 99 zones) are not fully supported yet. See [Channels - Thermo](#configuring-thermo) for more details. | Successfully tested: H/LN4691, HS4692, KG4691; thermo sensors: L/N/NT4577 + 3455 |
|
||||
| CEN & CEN+ Scenarios | `15` & `25` | `bus_cen_scenario_control`, `bus_cenplus_scenario_control` | CEN/CEN+ scenarios events and virtual activation | Successfully tested: scenario buttons: HC/HD/HS/L/N/NT4680 |
|
||||
| Dry Contact and IR Interfaces | `25` | `bus_dry_contact_ir` | Dry Contacts and IR Interfaces | Successfully tested: contact interfaces F428 and 3477; IR sensors: HC/HD/HS/L/N/NT4610 |
|
||||
| Energy Management | `18` | `bus_energy_meter` | Energy Management | Successfully tested: F520, F521 |
|
||||
| Category | WHO | Thing Type IDs | Description | Status |
|
||||
| ----------------------------- | :----------: | :--------------------------------------------------------: | ---------------------------------------------------------------- | ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
|
||||
| Gateway Management | `13` | `bus_gateway` | Any IP gateway supporting OpenWebNet protocol should work | Successfully tested: F452, F453, F453AV,F454, F455, MyHOMEServer1, MyHOME_Screen10, MyHOME_Screen3,5, MH201, MH202, MH200N. Some connection stability issues/gateway resets reported with MH202 |
|
||||
| Lighting | `1` | `bus_on_off_switch`, `bus_dimmer` | BUS switches and dimmers | Successfully tested: F411/2, F411/4, F411U2, F422, F429. Some discovery issues reported with F429 (DALI Dimmers) |
|
||||
| Automation | `2` | `bus_automation` | BUS roller shutters, with position feedback and auto-calibration | Successfully tested: LN4672M2 |
|
||||
| Temperature Control | `4` | `bus_thermo_zone`, `bus_thermo_sensor`, `bus_thermo_cu` | Thermo zones management and temperature sensors (probes). | Successfully tested: H/LN4691, HS4692, KG4691; thermo sensors: L/N/NT4577 + 3455; Central Units (4 or 99 zones) are not fully supported yet. See [Channels - Thermo](#configuring-thermo) for more details |
|
||||
| CEN & CEN+ Scenarios | `15` & `25` | `bus_cen_scenario_control`, `bus_cenplus_scenario_control` | CEN/CEN+ scenarios events and virtual activation | Successfully tested: scenario buttons: HC/HD/HS/L/N/NT4680 |
|
||||
| Dry Contact and IR Interfaces | `25` | `bus_dry_contact_ir` | Dry Contacts and IR Interfaces | Successfully tested: contact interfaces F428 and 3477; IR sensors: HC/HD/HS/L/N/NT4610 |
|
||||
| Energy Management | `18` | `bus_energy_meter` | Energy Management | Successfully tested: F520, F521 |
|
||||
|
||||
### For ZigBee (Radio)
|
||||
|
||||
| Category | WHO | Thing Type IDs | Description | Status |
|
||||
| -------------------- | :----: | :-------------------------------: | :-------------------------------------------------------------------: | ------------------------------------ |
|
||||
| Gateway Management | `13` | `zb_gateway` | ZigBee USB Gateway (models: BTI-3578 / LG 088328) | Tested: BTI-3578 and LG 088328 |
|
||||
| Lighting | `1` | `zb_dimmer`, `zb_on_off_switch`, `zb_on_off_switch2u` | ZigBee dimmers, switches and 2-unit switches | Tested: BTI-4591, BTI-3584, BTI-4585 |
|
||||
| Automation | `2` | `zb_automation` | ZigBee roller shutters | |
|
||||
| Category | WHO | Thing Type IDs | Description | Status |
|
||||
| -------------------- | :----: | :---------------------------------------------------: | :-------------------------------------------------------------------: | ------------------------------------ |
|
||||
| Gateway Management | `13` | `zb_gateway` | ZigBee USB Gateway (models: BTI-3578 / LG 088328) | Tested: BTI-3578 and LG 088328 |
|
||||
| Lighting | `1` | `zb_dimmer`, `zb_on_off_switch`, `zb_on_off_switch2u` | ZigBee dimmers, switches and 2-unit switches | Tested: BTI-4591, BTI-3584, BTI-4585 |
|
||||
| Automation | `2` | `zb_automation` | ZigBee roller shutters | |
|
||||
|
||||
## Discovery
|
||||
|
||||
@@ -150,36 +150,45 @@ Temperature sensors can be configured defining a `bus_thermo_sensor` Thing with
|
||||
- example sensor `5` of external zone `00` --> `where="500"`
|
||||
- example: slave sensor `3` of zone `2` --> `where="302"`
|
||||
|
||||
#### NOTE
|
||||
The (optional) Central Unit can be configured defining a `bus_themo_cu` Thing.
|
||||
|
||||
Systems with Central Units (4 or 99 zones) are not fully supported yet.
|
||||
### Central Unit integration missing points
|
||||
|
||||
- Read setPoint temperature and current mode
|
||||
- Holiday activation command (all zones)
|
||||
- Discovery
|
||||
|
||||
## Channels
|
||||
|
||||
### Lighting, Automation, Power meter, CEN/CEN+ Scenario Events and Dry Contact / IR Interfaces channels
|
||||
|
||||
| Channel Type ID (channel ID) | Applies to Thing Type IDs | Item Type | Description | Read/Write |
|
||||
| ---------------------------------------- | ------------------------------------------------------------- | ------------- | ----------------------------------------------------- | :--------: |
|
||||
| `switch` or `switch_01`/`02` for ZigBee | `bus_on_off_switch`, `zb_on_off_switch`, `zb_on_off_switch2u` | Switch | To switch the device `ON` and `OFF` | R/W |
|
||||
| `brightness` | `bus_dimmer`, `zb_dimmer` | Dimmer | To adjust the brightness value (Percent, `ON`, `OFF`) | R/W |
|
||||
| `shutter` | `bus_automation` | Rollershutter | To activate roller shutters (`UP`, `DOWN`, `STOP`, Percent - [see Shutter position](#shutter-position)) | R/W |
|
||||
| `button#X` | `bus_cen_scenario_control`, `bus_cenplus_scenario_control` | String | Trigger channel for CEN/CEN+ scenario events [see possible values](#cen-cen-channels) | R (TRIGGER) |
|
||||
| `sensor` | `bus_dry_contact_ir` | Switch | Indicates if a Dry Contact Interface is `ON`/`OFF`, or if a IR Sensor is detecting movement (`ON`), or not (`OFF`) | R |
|
||||
| `power` | `bus_energy_meter` | Number:Power | The current active power usage from Energy Meter | R |
|
||||
| Channel Type ID (channel ID) | Applies to Thing Type IDs | Item Type | Description | Read/Write |
|
||||
| ---------------------------------------- | ------------------------------------------------------------- | ------------- | ------------------------------------------------------------------------------------------------------------------- | :---------: |
|
||||
| `switch` or `switch_01`/`02` for ZigBee | `bus_on_off_switch`, `zb_on_off_switch`, `zb_on_off_switch2u` | Switch | To switch the device `ON` and `OFF` | R/W |
|
||||
| `brightness` | `bus_dimmer`, `zb_dimmer` | Dimmer | To adjust the brightness value (Percent, `ON`, `OFF`) | R/W |
|
||||
| `shutter` | `bus_automation` | Rollershutter | To activate roller shutters (`UP`, `DOWN`, `STOP`, Percent - [see Shutter position](#shutter-position)) | R/W |
|
||||
| `button#X` | `bus_cen_scenario_control`, `bus_cenplus_scenario_control` | String | Trigger channel for CEN/CEN+ scenario events [see possible values](#cen-cen-channels) | R (TRIGGER) |
|
||||
| `sensor` | `bus_dry_contact_ir` | Switch | Indicates if a Dry Contact Interface is `ON`/`OFF`, or if a IR Sensor is detecting movement (`ON`), or not (`OFF`) | R |
|
||||
| `power` | `bus_energy_meter` | Number:Power | The current active power usage from Energy Meter | R |
|
||||
|
||||
### Thermo channels
|
||||
|
||||
| Channel Type ID (channel ID) | Applies to Thing Type IDs | Item Type | Description | Read/Write | Advanced |
|
||||
| ---------------------------- | ----------------------------------- | ------------------ | ------------------------------------------------- | :--------: | :------: |
|
||||
| `temperature` | `bus_thermo_zone`, `bus_thermo_sensor` | Number:Temperature | The zone currently sensed temperature | R | N |
|
||||
| `setpointTemperature` | `bus_thermo_zone` | Number:Temperature | The zone setpoint temperature | R/W | N |
|
||||
| `function` | `bus_thermo_zone` | String | The zone set thermo function: `COOLING`, `HEATING` or `GENERIC` (heating + cooling) | R/W | N |
|
||||
| `mode` | `bus_thermo_zone` | String | The zone set mode: `MANUAL`, `PROTECTION`, `OFF` | R/W | N |
|
||||
| `speedFanCoil` | `bus_thermo_zone` | String | The zone fancoil speed: `AUTO`, `SPEED_1`, `SPEED_2`, `SPEED_3` | R/W | N |
|
||||
| `actuators` | `bus_thermo_zone` | String | The zone actuator(s) status: `OFF`, `ON`, `OPENED`, `CLOSED` , `STOP`, `OFF_FAN_COIL`, `ON_SPEED_1`, `ON_SPEED_2`, `ON_SPEED_3`, `OFF_SPEED_1`, `OFF_SPEED_2`, `OFF_SPEED_3` | R | Y |
|
||||
| `heatingValves` | `bus_thermo_zone` | String | The zone heating valve(s) status: `OFF`, `ON`, `OPENED`, `CLOSED` , `STOP`, `OFF_FAN_COIL`, `ON_SPEED_1`, `ON_SPEED_2`, `ON_SPEED_3`, `OFF_SPEED_1`, `OFF_SPEED_2`, `OFF_SPEED_3` | R | Y |
|
||||
| `conditioningValves` | `bus_thermo_zone` | String | The zone conditioning valve(s) status: `OFF`, `ON`, `OPENED`, `CLOSED` , `STOP`, `OFF_FAN_COIL`, `ON_SPEED_1`, `ON_SPEED_2`, `ON_SPEED_3`, `OFF_SPEED_1`, `OFF_SPEED_2`, `OFF_SPEED_3` | R | Y |
|
||||
| Channel Type ID (channel ID) | Applies to Thing Type IDs | Item Type | Description | Read/Write | Advanced |
|
||||
| ---------------------------- | -------------------------------------- | ------------------ | --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | :--------: | :------: |
|
||||
| `temperature` | `bus_thermo_zone`, `bus_thermo_sensor` | Number:Temperature | The zone currently sensed temperature | R | N |
|
||||
| `setpointTemperature` | `bus_thermo_zone`, `bus_thermo_cu` | Number:Temperature | The zone or Central Unit setpoint temperature | R/W | N |
|
||||
| `function` | `bus_thermo_zone` | String | The zone set thermo function: `COOLING`, `HEATING` or `GENERIC` (heating + cooling) | R/W | N |
|
||||
| `mode` | `bus_thermo_zone`, `bus_thermo_cu` | String | The zone set mode (`MANUAL`, `PROTECTION`, `OFF`) or the Central Unit set mode ( `MANUAL`, `PROTECTION`, `OFF`, `WEEKLY`, `SCENARIO`) | R/W | N |
|
||||
| `speedFanCoil` | `bus_thermo_zone` | String | The zone fancoil speed: `AUTO`, `SPEED_1`, `SPEED_2`, `SPEED_3` | R/W | N |
|
||||
| `actuators` | `bus_thermo_zone` | String | The zone actuator(s) status: `OFF`, `ON`, `OPENED`, `CLOSED` , `STOP`, `OFF_FAN_COIL`, `ON_SPEED_1`, `ON_SPEED_2`, `ON_SPEED_3`, `OFF_SPEED_1`, `OFF_SPEED_2`, `OFF_SPEED_3` | R | Y |
|
||||
| `heatingValves` | `bus_thermo_zone` | String | The zone heating valve(s) status: `OFF`, `ON`, `OPENED`, `CLOSED` , `STOP`, `OFF_FAN_COIL`, `ON_SPEED_1`, `ON_SPEED_2`, `ON_SPEED_3`, `OFF_SPEED_1`, `OFF_SPEED_2`, `OFF_SPEED_3` | R | Y |
|
||||
| `conditioningValves` | `bus_thermo_zone` | String | The zone conditioning valve(s) status: `OFF`, `ON`, `OPENED`, `CLOSED` , `STOP`, `OFF_FAN_COIL`, `ON_SPEED_1`, `ON_SPEED_2`, `ON_SPEED_3`, `OFF_SPEED_1`, `OFF_SPEED_2`, `OFF_SPEED_3` | R | Y |
|
||||
| `localOffset` | `bus_thermo_zone` | String | The zone local offset status: `OFF`, `PROTECTION`, `MINUS_3`, `MINUS_2` , `MINUS_1`, `NORMAL`, `PLUS_1`, `PLUS_2`, `PLUS_3` | R | Y |
|
||||
| `remoteControl` | `bus_thermo_cu` | String | The Central Unit Remote Control status: `ENABLED`, `DISABLED` | R | Y |
|
||||
| `batteryStatus` | `bus_thermo_cu` | String | The Central Unit Battery status: `OK`, `KO` | R | Y |
|
||||
| `weeklyProgram` | `bus_thermo_cu` | Number | The program number (`1`, `2`, `3`) when Central Unit mode is `WEEKLY` | R/W | N |
|
||||
| `scenarioProgram` | `bus_thermo_cu` | Number | The program number (`1`, `2`, .. , `16`) when Central Unit mode is `SCENARIO` | R/W | N |
|
||||
|
||||
|
||||
### Notes on channels
|
||||
|
||||
@@ -218,6 +227,15 @@ See [openwebnet.sitemap](#openwebnet-sitemap) & [openwebnet.rules](#openwebnet-r
|
||||
- `EXTENDED_PRESS` - sent after `START_EXTENDED_PRESS` if you keep the button pressed longer; will be sent again every 0,5sec as long as you hold pressed (good for dimming rules)
|
||||
- `RELEASE_EXTENDED_PRESS` - sent once when you finally release the button after having it pressed longer than 0,5sec
|
||||
|
||||
#### `mode` for values WEEKLY and SCENARIO (Central Unit)
|
||||
|
||||
There are three WEEKLY and sixteen SCENARIO programs defined for the Central Unit.
|
||||
|
||||
In order to activate one of them you have to use two different channels:
|
||||
- with `mode` you can set the mode (`WEEKLY` or `SCENARIO`)
|
||||
- with `weeklyProgram` (if `WEEKLY` was setted) or with `scenarioProgram` (if `SCENARIO` was setted) you can set the program number
|
||||
|
||||
Example: if you want to activate SCENARIO #9 you have to set `mode` = `SCENARIO` and `scenarioProgram` = `9`.
|
||||
|
||||
## Full Example
|
||||
|
||||
@@ -230,10 +248,14 @@ Bridge openwebnet:bus_gateway:mybridge "MyHOMEServer1" [ host="192.168.1.35", pa
|
||||
bus_on_off_switch LR_switch "Living Room Light" [ where="51" ]
|
||||
bus_dimmer LR_dimmer "Living Room Dimmer" [ where="0311#4#01" ]
|
||||
bus_automation LR_shutter "Living Room Shutter" [ where="93", shutterRun="10050"]
|
||||
|
||||
bus_energy_meter CENTRAL_Ta "Energy Meter Ta" [ where="51" ]
|
||||
bus_energy_meter CENTRAL_Tb "Energy Meter Tb" [ where="52" ]
|
||||
|
||||
bus_thermo_cu CU_3550 "99 zones central unit" [ where="0" ]
|
||||
bus_thermo_zone LR_zone "Living Room Zone" [ where="2"]
|
||||
bus_thermo_sensor EXT_tempsensor "External Temperature" [ where="500"]
|
||||
|
||||
bus_cen_scenario_control LR_CEN_scenario "Living Room CEN" [ where="51", buttons="4,3,8"]
|
||||
bus_cenplus_scenario_control LR_CENplus_scenario "Living Room CEN+" [ where="212", buttons="1,5,18" ]
|
||||
bus_dry_contact_ir LR_IR_sensor "Living Room IR Sensor" [ where="399" ]
|
||||
@@ -255,17 +277,25 @@ Bridge openwebnet:zb_gateway:myZBgateway [ serialPort="COM3" ] {
|
||||
|
||||
Example items linked to BUS devices:
|
||||
|
||||
NOTE: lights, blinds and zones (thermostat) can be handled from personal assistants (Google Home, Alexa). In the following example `Google Assistant` was configured (`ga="..."`) according to the [official documentation](https://www.openhab.org/docs/ecosystem/google-assistant).
|
||||
NOTE: lights, blinds and zones (thermostat) can be handled from personal assistants (Google Home, Alexa). In the following example `Google Assistant` (`ga="..."`) and `HomeKit` (`homekit="..."`) were configured according to the [Google official documentation](https://www.openhab.org/docs/ecosystem/google-assistant) and [HomeKit official documentation](https://www.openhab.org/addons/integrations/homekit/)
|
||||
|
||||
```
|
||||
Switch iLR_switch "Light" (gLivingRoom) { channel="openwebnet:bus_on_off_switch:mybridge:LR_switch:switch", ga="Light" }
|
||||
Dimmer iLR_dimmer "Dimmer [%.0f %%]" (gLivingRoom) { channel="openwebnet:bus_dimmer:mybridge:LR_dimmer:brightness", ga="Light" }
|
||||
Switch iLR_switch "Light" (gLivingRoom) { channel="openwebnet:bus_on_off_switch:mybridge:LR_switch:switch", ga="Light", homekit="Lighting" }
|
||||
Dimmer iLR_dimmer "Dimmer [%.0f %%]" (gLivingRoom) { channel="openwebnet:bus_dimmer:mybridge:LR_dimmer:brightness", ga="Light", homekit="Lighting" }
|
||||
|
||||
Rollershutter iLR_shutter "Shutter [%.0f %%]" (gShutters, gLivingRoom) { channel="openwebnet:bus_automation:mybridge:LR_shutter:shutter", ga="Blinds" }
|
||||
Rollershutter iLR_shutter "Shutter [%.0f %%]" (gShutters, gLivingRoom) { channel="openwebnet:bus_automation:mybridge:LR_shutter:shutter", ga="Blinds", homekit = "Window" }
|
||||
|
||||
Number:Power iCENTRAL_Ta "Power [%.0f %unit%]" { channel="openwebnet:bus_energy_meter:mybridge:CENTRAL_Ta:power" }
|
||||
Number:Power iCENTRAL_Tb "Power [%.0f %unit%]" { channel="openwebnet:bus_energy_meter:mybridge:CENTRAL_Tb:power" }
|
||||
|
||||
// 99 zones central unit
|
||||
Group gCentralUnit "Central Unit"
|
||||
Number:Temperature iCU_3550_manualset "Temperature" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:setpointTemperature", ga="thermostatTemperatureSetpoint" }
|
||||
String iCU_3550_remote "Remote Control" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:remoteControl" }
|
||||
String iCU_3550_battery "Battery Status" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:batteryStatus" }
|
||||
String iCU_3550_mode "Mode" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:mode" }
|
||||
Number iCU_3550_wpn "Weekly Program" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:weeklyProgram" }
|
||||
Number iCU_3550_spn "Scenario Program" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:scenarioProgram" }
|
||||
|
||||
Group gLivingRoomZone "Living Room Zone" { ga="Thermostat" [ modes="auto=GENERIC,heat=HEATING,cool=COOLING", thermostatTemperatureRange="7,35", useFahrenheit=false ] }
|
||||
Number:Temperature iLR_zone_temp "Temperature [%.1f %unit%]" (gLivingRoomZone) { channel="openwebnet:bus_thermo_zone:mybridge:LR_zone:temperature", ga="thermostatTemperatureAmbient" }
|
||||
|
||||