The binding retrieves and periodically updates all basic system information from the thermostat.
|
The binding retrieves and periodically updates all basic system information from the thermostat.
|
||||||
The main thermostat functions such as thermostat mode, fan mode, temperature set point and hold mode can be controlled.
|
The main thermostat functions such as thermostat mode, fan mode, temperature set point and hold mode can be controlled.
|
||||||
System run-time information and humidity readings are polled less frequently and can be disabled completely if not desired.
|
System run-time information and humidity readings are polled less frequently and can be disabled completely if not desired.
|
||||||
Humidity information is available only when using a CT80 thermostat and I have noticed that the humidity reported is very inaccurate.
|
|
||||||
|
|
||||||
The main caveat for using this binding is to keep in mind that the web server in the thermostat is very slow.
|
|
||||||
Do not over load it with excessive amounts of simultaneous commands.
|
|
||||||
When changing the thermostat mode, the current temperature set point is cleared and a refresh of the thermostat data is done to get the new mode's set point.
|
|
||||||
Since retrieving the thermostat's data is the slowest operation, it will take several seconds after changing the mode before the new set point is displayed.
|
|
||||||
The 'Program Mode' command is untested and according to the published API is only available on a CT80 Rev B.
|
|
||||||
|
|
||||||
## Supported Things
|
## Supported Things
|
||||||
|
|
||||||
There is exactly one supported thing type, which represents the thermostat.
|
There is exactly one supported thing type, which represents any of the supported thermostat models.
|
||||||
It has the `rtherm` id.
|
It has the `rtherm` id.
|
||||||
Multiple Things can be added if more than one thermostat is to be controlled.
|
Multiple Things can be added if more than one thermostat is to be controlled.
|
||||||
|
|
||||||
|
@ -34,14 +27,22 @@ The binding has no configuration options, all configuration is done at Thing lev
|
||||||
The thing has a few configuration parameters:
|
The thing has a few configuration parameters:
|
||||||
|
|
||||||
| Parameter | Description |
|
| Parameter | Description |
|
||||||
|-----------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
|
|-----------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
|
||||||
| hostName | The host name or IP address of the thermostat. Mandatory. |
|
| hostName | The host name or IP address of the thermostat. Mandatory. |
|
||||||
| refresh | Overrides the refresh interval of the thermostat data. Optional, the default is 2 minutes. |
|
| refresh | Overrides the refresh interval of the thermostat data. Optional, the default is 2 minutes. |
|
||||||
| logRefresh | Overrides the refresh interval of the run-time logs & humidity data. Optional, the default is 10 minutes. |
|
| logRefresh | Overrides the refresh interval of the run-time logs & humidity data. Optional, the default is 10 minutes. |
|
||||||
| isCT80 | Flag to enable additional features only available on the CT80 thermostat. Optional, the default is false. |
|
| isCT80 | Flag to enable additional features only available on the CT80 thermostat. Optional, the default is false. |
|
||||||
| disableLogs | Disable retrieval of run-time logs from the thermostat. Optional, the default is false. |
|
| disableLogs | Disable retrieval of run-time logs from the thermostat. Optional, the default is false. |
|
||||||
| setpointMode | Controls temporary or absolute setpoint mode. In "temporary" mode the thermostat will temporarily maintain the given setpoint, returning to its program after a time. In "absolute" mode the thermostat will ignore its program maintaining the given setpoint. |
|
| setpointMode | Controls temporary or absolute setpoint mode. In "temporary" mode the thermostat will temporarily maintain the given setpoint until the next scheduled setpoint time period. In "absolute" mode the thermostat will ignore its program and maintain the given setpoint indefinitely. Optional, the default is "temporary". |
|
||||||
| clockSync | Flag to enable the binding to sync the internal clock on the thermostat to match the openHAB host's system clock. Use if the thermostat is not setup to connect to the manufacturer's cloud server. Sync occurs at binding startup and every hour thereafter. |
|
| clockSync | Flag to enable the binding to sync the internal clock on the thermostat to match the openHAB host's system clock. Use if the thermostat is not setup to connect to the manufacturer's cloud server. Sync occurs at binding startup and every hour thereafter. Optional, the default is false. |
|
||||||
|
|
||||||
|
Some notes:
|
||||||
|
|
||||||
|
* The main caveat for using this binding is to keep in mind that the web server in the thermostat is very slow. Do not over load it with excessive amounts of simultaneous commands.
|
||||||
|
* When changing the thermostat mode, the current temperature set point is cleared and a refresh of the thermostat data is done to get the new mode's set point.
|
||||||
|
* Since retrieving the thermostat's data is the slowest operation, it will take several seconds after changing the mode before the new set point is displayed.
|
||||||
|
* The 'Program Mode' command is untested and according to the published API is only available on a CT80 Rev B.
|
||||||
|
* Humidity information is available only when using a CT80 thermostat.
|
||||||
|
|
||||||
## Channels
|
## Channels
|
||||||
|
|
||||||
|
@ -126,7 +127,7 @@ radiotherm.items:
|
||||||
```
|
```
|
||||||
Number:Temperature Therm_Temp "Current Temperature [%.1f °F] " <temperature> { channel="radiothermostat:rtherm:mytherm1:temperature" }
|
Number:Temperature Therm_Temp "Current Temperature [%.1f °F] " <temperature> { channel="radiothermostat:rtherm:mytherm1:temperature" }
|
||||||
// Humidity only supported on CT80
|
// Humidity only supported on CT80
|
||||||
Number Therm_Hum "Current Humidity [%d %%]" <temperature> { channel="radiothermostat:rtherm:mytherm1:humidity" }
|
Number Therm_Hum "Current Humidity [%d %%]" <humidity> { channel="radiothermostat:rtherm:mytherm1:humidity" }
|
||||||
Number Therm_Mode "Thermostat Mode [MAP(radiotherm.map):%s_mode]" { channel="radiothermostat:rtherm:mytherm1:mode" }
|
Number Therm_Mode "Thermostat Mode [MAP(radiotherm.map):%s_mode]" { channel="radiothermostat:rtherm:mytherm1:mode" }
|
||||||
// The Auto/Circulate option will only appear for CT80
|
// The Auto/Circulate option will only appear for CT80
|
||||||
Number Therm_Fmode "Fan Mode [MAP(radiotherm.map):%s_fan]" { channel="radiothermostat:rtherm:mytherm1:fan_mode" }
|
Number Therm_Fmode "Fan Mode [MAP(radiotherm.map):%s_fan]" { channel="radiothermostat:rtherm:mytherm1:fan_mode" }
|
||||||
|
|