Use system channel types for humidity and outdoor temperature (#12277)
Signed-off-by: Jacob Laursen <jacob-github@vindvejr.dk>
This commit is contained in:
parent
7d3f3c56a7
commit
b750d85a11
@ -19,7 +19,7 @@ thing-type.config.danfossairunit.airunit.updateUnchangedValuesEveryMillis.descri
|
|||||||
|
|
||||||
# channel group types
|
# channel group types
|
||||||
|
|
||||||
channel-group-type.danfossairunit.humidity.label = Humidity
|
channel-group-type.danfossairunit.humidity.channel.humidity.label = Humidity
|
||||||
channel-group-type.danfossairunit.humidity.channel.humidity.description = Current relative humidity measured by the air unit
|
channel-group-type.danfossairunit.humidity.channel.humidity.description = Current relative humidity measured by the air unit
|
||||||
channel-group-type.danfossairunit.main.label = Mode and Fan Speeds
|
channel-group-type.danfossairunit.main.label = Mode and Fan Speeds
|
||||||
channel-group-type.danfossairunit.main.channel.boost.label = Boost
|
channel-group-type.danfossairunit.main.channel.boost.label = Boost
|
||||||
|
|||||||
@ -80,7 +80,7 @@
|
|||||||
<label>Calculated Room Temperature</label>
|
<label>Calculated Room Temperature</label>
|
||||||
<description>Calculated Room Temperature</description>
|
<description>Calculated Room Temperature</description>
|
||||||
</channel>
|
</channel>
|
||||||
<channel id="outdoor_temp" typeId="temperature">
|
<channel id="outdoor_temp" typeId="system.outdoor-temperature">
|
||||||
<label>Outdoor Temperature</label>
|
<label>Outdoor Temperature</label>
|
||||||
<description>Temperature of the air outside</description>
|
<description>Temperature of the air outside</description>
|
||||||
</channel>
|
</channel>
|
||||||
@ -89,7 +89,8 @@
|
|||||||
<channel-group-type id="humidity">
|
<channel-group-type id="humidity">
|
||||||
<label>Humidity</label>
|
<label>Humidity</label>
|
||||||
<channels>
|
<channels>
|
||||||
<channel id="humidity" typeId="humidity">
|
<channel id="humidity" typeId="system.atmospheric-humidity">
|
||||||
|
<label>Humidity</label>
|
||||||
<description>Current relative humidity measured by the air unit</description>
|
<description>Current relative humidity measured by the air unit</description>
|
||||||
</channel>
|
</channel>
|
||||||
</channels>
|
</channels>
|
||||||
@ -200,17 +201,6 @@
|
|||||||
<description>Read only percentage</description>
|
<description>Read only percentage</description>
|
||||||
<state pattern="%.0f %%" readOnly="true" min="0" max="100"/>
|
<state pattern="%.0f %%" readOnly="true" min="0" max="100"/>
|
||||||
</channel-type>
|
</channel-type>
|
||||||
<channel-type id="humidity">
|
|
||||||
<item-type>Number:Dimensionless</item-type>
|
|
||||||
<label>Humidity</label>
|
|
||||||
<category>Humidity</category>
|
|
||||||
<tags>
|
|
||||||
<tag>Measurement</tag>
|
|
||||||
<tag>Humidity</tag>
|
|
||||||
</tags>
|
|
||||||
<state pattern="%.0f %%" readOnly="true" min="0" max="100">
|
|
||||||
</state>
|
|
||||||
</channel-type>
|
|
||||||
<channel-type id="switch">
|
<channel-type id="switch">
|
||||||
<item-type>Switch</item-type>
|
<item-type>Switch</item-type>
|
||||||
<label>Something that can be turned on or off</label>
|
<label>Something that can be turned on or off</label>
|
||||||
|
|||||||
Loading…