[velux] Add support for vane/slat position (#12618)
Signed-off-by: Andrew Fiddian-Green <software@whitebear.ch>
This commit is contained in:
committed by
GitHub
parent
ec5794739c
commit
b9782484c6
@@ -38,6 +38,10 @@ The binding will automatically discover Velux Bridges within the local network,
|
||||
Once a Velux Bridge has been discovered, you will need to enter the `password` Configuration Parameter (see below) before the binding can communicate with it.
|
||||
And once the Velux Bridge is fully configured, the binding will automatically discover all its respective scenes and actuators (like windows and rollershutters), and place them in the Inbox.
|
||||
|
||||
Note: When the KLF200 hub is started it provides a temporary private Wi-Fi Access Point for initial configuration.
|
||||
And if any device connects to this AP, it disables the normal LAN connection, thus preventing the binding from connecting.
|
||||
So make sure this AP is not permanently on (the default setting is that the AP will turn off after some time).
|
||||
|
||||
## Thing Configuration
|
||||
|
||||
### Thing Configuration for "bridge"
|
||||
@@ -135,7 +139,7 @@ The supported Channels and their associated channel types are shown below.
|
||||
| downtime | Number | Time interval (sec) between last successful and most recent device interaction. |
|
||||
| doDetection | Switch | Command to activate bridge detection mode. |
|
||||
|
||||
### Channels for "window" / "rollershutter" Things
|
||||
### Channels for "window" Things
|
||||
|
||||
The supported Channels and their associated channel types are shown below.
|
||||
|
||||
@@ -154,6 +158,23 @@ The `position` Channel indicates the open/close state of the window (resp. rolle
|
||||
- In case of errors (e.g. window jammed) the display is `UNDEF`.
|
||||
- If a Somfy actuator is commanded to its 'favorite' position via a Somfy remote control, under some circumstances the display is `UNDEF`. See also Rules below.
|
||||
|
||||
### Channels for "rollershutter" Things
|
||||
|
||||
The supported Channels and their associated channel types are shown below.
|
||||
|
||||
| Channel | Data Type | Description |
|
||||
|--------------|---------------|-------------------------------------------------|
|
||||
| position | Rollershutter | Actual position of the window or device. |
|
||||
| limitMinimum | Rollershutter | Minimum limit position of the window or device. |
|
||||
| limitMaximum | Rollershutter | Maximum limit position of the window or device. |
|
||||
| vanePosition | Dimmer | Vane position of a Venetian blind. |
|
||||
|
||||
The `position`, `limitMinimum`, and `limitMaximum` are the same as described above for "window" Things.
|
||||
|
||||
The `vanePosition` Channel only applies to Venetian blinds that have tiltable slats.
|
||||
It can only have a valid position value if the main `position` of the Thing is fully down.
|
||||
So, if `vanePosition` is commanded to a new value, this will automatically cause the main `position` to move to the fully down position.
|
||||
|
||||
### Channels for "actuator" Things
|
||||
|
||||
The supported Channels and their associated channel types are shown below.
|
||||
|
||||
Reference in New Issue