* [openthermgateway] clean version of prior PR * [openthermgateway] fix NoSuchMethod exception * [openthermgateway] create thread according to OH guidelines * [openthermgateway] fix annotation warning * [openthermgateway] framework handles bridge status changes * [openthermgateway] implement learnings from PR #12356 * [openthermgateway] add ReadMe chapter on migration v3.2 .. v3.3 * [openthermgateway] delete duplicate OpenThermGatewayBindingConstants class * [openthermgateway] remove redundant else clause, remove npe warning * [openthermgateway] log to debug rather than info; eliminate static import * [openthermgateway] eliminate static import * [openthermgateway] suppress unused argument warning * [openthermgateway] delete xml definitions for no longer used 'otgw' Thing type Signed-off-by: Andrew Fiddian-Green <software@whitebear.ch>
This commit is contained in:
committed by
GitHub
parent
5842ad1644
commit
ba07a870fe
@@ -1,195 +1,443 @@
|
||||
# OpenTherm Gateway Binding
|
||||
|
||||
This binding is used to integrate the OpenTherm Gateway into openHAB.
|
||||
The OpenTherm Gateway is a module designed by Schelte Bron that is connected in between a boiler and a thermostat and communicates using the OpenTherm protocol.
|
||||
The OpenTherm Gateway is a module designed by Schelte Bron that can be connected to units that support communication using the OpenTherm protocol, such as boiler or ventilation / heat recovery unit.
|
||||
|
||||
More information on the OpenTherm Gateway device can be found at https://otgw.tclcode.com/
|
||||
|
||||
## Supported Things
|
||||
|
||||
The OpenTherm Gateway binding currently only supports one thing, and that's the gateway itself.
|
||||
|
||||
## Discovery
|
||||
|
||||
The binding does not support auto discovery.
|
||||
|
||||
## Binding Configuration
|
||||
|
||||
The binding itself does not require any configuration.
|
||||
The binding does not require any configuration.
|
||||
|
||||
## Supported Things
|
||||
|
||||
The OpenTherm Gateway binding supports three Things:
|
||||
|
||||
- `openthermgateway` which is the bridge that handles communication with the OpenTherm Gateway device.
|
||||
- `boiler` which represents a central heating boiler unit.
|
||||
- `ventilationheatrecovery` which represents a ventilation / heat recovery unit.
|
||||
|
||||
## Thing Configuration
|
||||
|
||||
The binding is designed to support various ways of connecting to the OpenTherm Gateway device, but currently only supports a TCP socket connection.
|
||||
The configuration settings for the thing are Hostname/IP address and Port, which are used to connect to the gateway, and an automatic connection retry interval in case the connection to the OpenTherm Gateway device is lost.
|
||||
### Thing Configuration for `openthermgateway`
|
||||
|
||||
| Parameter | Name | Description | Required | Default |
|
||||
|---------------------------|---------------------------|-----------------------------------------------------------------|----------|---------|
|
||||
| `ipaddress` | Hostname or IP address | The hostname or IP address to connect to the OpenTherm Gateway. | yes | |
|
||||
| `port` | Port | The port used to connect to the OpenTherm Gateway. | yes | |
|
||||
| `connectionRetryInterval` | Connection Retry Interval | The interval in seconds to retry connecting (0 = disabled). | yes | 60 |
|
||||
The `openthermgateway` bridge is designed to support various ways of connecting to the OpenTherm Gateway device, but currently only supports a TCP socket connection.
|
||||
The configuration settings for the bridge are Hostname/IP address and Port, which are used to connect to the gateway, and an automatic connection retry interval in case the connection to the OpenTherm Gateway device is lost.
|
||||
|
||||
| Parameter | Name | Description | Required | Default |
|
||||
|---------------------------|---------------------------|----------------------------------------------------------------------------------|----------|---------|
|
||||
| `ipaddress` | Hostname or IP address | The hostname or IP address to connect to the OpenTherm Gateway. | yes | |
|
||||
| `port` | Port | The port used to connect to the OpenTherm Gateway. | yes | |
|
||||
| `connectionRetryInterval` | Connection Retry Interval | The interval in seconds to retry connecting (0 = disabled). | yes | 60 |
|
||||
| `connectTimeoutSeconds` | Connect Timeout | The maximum time (seconds) to wait for establishing a connection to the gateway. | yes | 5 |
|
||||
| `readTimeoutSeconds` | Read Timeout | The maximum time (seconds) to wait for reading responses from the gateway. | yes | 20 |
|
||||
|
||||
### Thing Configuration for `boiler` and `ventilationheatrecovery`
|
||||
|
||||
The `boiler` and `ventilationheatrecovery` things do not require any configuration settings.
|
||||
|
||||
## Channels
|
||||
|
||||
The OpenTherm Gateway binding supports the following channels:
|
||||
### Channels for `openthermgateway`
|
||||
|
||||
The `openthermgateway` bridge supports the following channels:
|
||||
|
||||
| Channel Type ID | Item Type | Description | Access |
|
||||
|---------------------------|----------------------|----------------------------------------------------------|--------|
|
||||
| roomtemp | Number:Temperature | Current sensed room temperature | R |
|
||||
| roomsetpoint | Number:Temperature | Current room temperature setpoint | R |
|
||||
| temperaturetemporary | Number:Temperature | Temporary override room temperature setpoint | R/W |
|
||||
| temperatureconstant | Number:Temperature | Constant override room temperature setpoint | R/W |
|
||||
| controlsetpoint | Number:Temperature | Central heating water setpoint set at boiler | R |
|
||||
| controlsetpointrequested | Number:Temperature | Central heating water setpoint requested by thermostat | R |
|
||||
| controlsetpointoverride | Number:Temperature | Central heating water setpoint configured at gateway | R/W |
|
||||
| controlsetpoint2 | Number:Temperature | Central heating 2 water setpoint set at boiler | R |
|
||||
| controlsetpoint2requested | Number:Temperature | Central heating 2 water setpoint requested by thermostat | R |
|
||||
| controlsetpoint2override | Number:Temperature | Central heating 2 water setpoint configured at gateway | R/W |
|
||||
| dhwtemp | Number:Temperature | Domestic hot water temperature | R |
|
||||
| tdhwset | Number:Temperature | Domestic hot water temperature setpoint | R |
|
||||
| overridedhwsetpoint | Number:Temperature | Domestic hot water temperature setpoint override | R/W |
|
||||
| flowtemp | Number:Temperature | Boiler water temperature | R |
|
||||
| returntemp | Number:Temperature | Return water temperature | R |
|
||||
| outsidetemp | Number:Temperature | Outside temperature | R/W |
|
||||
| waterpressure | Number:Pressure | Central heating water pressure | R |
|
||||
| ch_enable | Switch | Central heating enabled set at boiler | R |
|
||||
| ch_enablerequested | Switch | Central heating enabled requested by thermostat | R |
|
||||
| ch_enableoverride | Switch | Central heating enabled overridden at gateway | R |
|
||||
| ch2_enable | Switch | Central heating 2 enabled set at boiler | R |
|
||||
| ch2_enablerequested | Switch | Central heating 2 enabled requested by thermostat | R |
|
||||
| ch2_enableoverride | Switch | Central heating 2 enabled overridden at gateway | R |
|
||||
| ch_mode | Switch | Central heating active | R |
|
||||
| dhw_enable | Switch | Domestic hot water enabled | R |
|
||||
| dhw_mode | Switch | Domestic hot water active | R |
|
||||
| flame | Switch | Burner active | R |
|
||||
| modulevel | Number:Dimensionless | Relative modulation level | R |
|
||||
| maxrelmdulevel | Number:Dimensionless | Maximum relative modulation level | R |
|
||||
| fault | Switch | Fault indication | R |
|
||||
| servicerequest | Switch | Service required | R |
|
||||
| lockout-reset | Switch | Lockout-reset enabled | R |
|
||||
| lowwaterpress | Switch | Low water pressure fault | R |
|
||||
| gasflamefault | Switch | Gas or flame fault | R |
|
||||
| airpressfault | Switch | Air pressure fault | R |
|
||||
| waterovtemp | Switch | Water over-temperature fault | R |
|
||||
| oemfaultcode | Switch | OEM fault code | R |
|
||||
| diag | Switch | Diagnostics indication | R |
|
||||
| unsuccessfulburnerstarts | Number:Dimensionless | Unsuccessful burner starts | R |
|
||||
| burnerstarts | Number:Dimensionless | Burner starts | R |
|
||||
| chpumpstarts | Number:Dimensionless | Central heating pump starts | R |
|
||||
| dhwpvstarts | Number:Dimensionless | Domestic hot water pump/valve starts | R |
|
||||
| dhwburnerstarts | Number:Dimensionless | Domestic hot water burner starts | R |
|
||||
| burnerhours | Number:Dimensionless | Burner hours | R |
|
||||
| chpumphours | Number:Dimensionless | Central heating pump hours | R |
|
||||
| dhwpvhours | Number:Dimensionless | Domestic hot water pump/valve hours | R |
|
||||
| dhwburnerhours | Number:Dimensionless | Domestic hot water burner hours | R |
|
||||
| sendcommand | Text | Channel to send commands to the OpenTherm Gateway device | W |
|
||||
|
||||
### Channels for `boiler`
|
||||
|
||||
The `boiler` thing supports the following channels:
|
||||
|
||||
| Channel ID | Item Type | Description | Access |
|
||||
|------------|-----------|-------------|--------|
|
||||
| roomtemp | Number:Temperature | Current sensed room temperature | R |
|
||||
| roomsetpoint | Number:Temperature | Current room temperature setpoint | R |
|
||||
| temperaturetemporary | Number:Temperature | Temporary override room temperature setpoint | R/W |
|
||||
| temperatureconstant | Number:Temperature | Constant override room temperature setpoint | R/W |
|
||||
| controlsetpoint | Number:Temperature | Central heating water setpoint set at boiler | R |
|
||||
| controlsetpointrequested | Number:Temperature | Central heating water setpoint requested by Thermostat | R |
|
||||
| controlsetpointoverride | Number:Temperature | Central heating water setpoint configured on OTGW | R/W |
|
||||
| controlsetpoint2 | Number:Temperature | Central heating 2 water setpoint set at boiler | R |
|
||||
| controlsetpoint2requested | Number:Temperature | Central heating 2 water setpoint requested by Thermostat | R |
|
||||
| controlsetpoint2override | Number:Temperature | Central heating 2 water setpoint configured on OTGW | R/W |
|
||||
| dhwtemp | Number:Temperature | Domestic hot water temperature | R |
|
||||
| tdhwset | Number:Temperature | Domestic hot water temperature setpoint | R |
|
||||
| overridedhwsetpoint | Number:Temperature | Domestic hot water temperature setpoint override | R/W |
|
||||
| flowtemp | Number:Temperature | Boiler water temperature | R |
|
||||
| returntemp | Number:Temperature | Return water temperature | R |
|
||||
| outsidetemp | Number:Temperature | Outside temperature | R/W |
|
||||
| waterpressure | Number:Dimensionless | Central heating water pressure | R |
|
||||
| ch_enable | Switch | Central heating enabled set at boiler | R |
|
||||
| ch_enablerequested | Switch | Central heating enabled requested by thermostat | R |
|
||||
| ch_enableoverride | Switch | Central heating enabled overridden at OTGW | R/W |
|
||||
| ch2_enable | Switch | Central heating 2 enabled set at boiler | R |
|
||||
| ch2_enablerequested | Switch | Central heating 2 enabled requested by thermostat | R |
|
||||
| ch2_enableoverride | Switch | Central heating 2 enabled overridden at OTGW | R/W |
|
||||
| ch_mode | Switch | Central heating active | R |
|
||||
| dhw_enable | Switch | Domestic hot water enabled | R |
|
||||
| dhw_mode | Switch | Domestic hot water active | R |
|
||||
| flame | Switch | Burner active | R |
|
||||
| modulevel | Number:Dimensionless | Relative modulation level | R |
|
||||
| maxrelmdulevel | Number:Dimensionless | Maximum relative modulation level | R |
|
||||
| fault | Switch | Fault indication | R |
|
||||
| servicerequest | Switch | Service required | R |
|
||||
| lockout-reset | Switch | Lockout-reset enabled | R |
|
||||
| lowwaterpress | Switch | Low water pressure fault | R |
|
||||
| gasflamefault | Switch | Gas or flame fault | R |
|
||||
| airpressfault | Switch | Air pressure fault | R |
|
||||
| waterovtemp | Switch | Water over-temperature fault | R |
|
||||
| oemfaultcode | Number:Dimensionless | OEM fault code | R |
|
||||
| diag | Switch | Diagnostics indication | R |
|
||||
| unsuccessfulburnerstarts | Number:Dimensionless | Unsuccessful burner starts | R |
|
||||
| burnerstarts | Number:Dimensionless | Burner starts | R |
|
||||
| chpumpstarts | Number:Dimensionless | Central heating pump starts | R |
|
||||
| dhwpvstarts | Number:Dimensionless | Domestic hot water pump/valve starts | R |
|
||||
| dhwburnerstarts | Number:Dimensionless | Domestic hot water burner starts | R |
|
||||
| burnerhours | Number:Time | Burner hours | R |
|
||||
| chpumphours | Number:Time | Central heating pump hours | R |
|
||||
| dhwpvhours | Number:Time | Domestic hot water pump/valve hours | R |
|
||||
| dhwburnerhours | Number:Time | Domestic hot water burner hours | R |
|
||||
| tspnumber | Number:Dimensionless | Number of transparant slave parameter entries | R |
|
||||
| tspentry | Number:Dimensionless | Transparent slave parameter entry | R |
|
||||
| fhbnumber | Number:Dimensionless | Number of fault history buffer entries | R |
|
||||
| fhbentry | Number:Dimensionless | Fault history buffer entry | R |
|
||||
|
||||
### Channels for `ventilationheatrecovery`
|
||||
|
||||
The `ventilationheatrecovery` thing supports the following channels:
|
||||
|
||||
| Channel ID | Item Type | Description | Access |
|
||||
|------------|-----------|-------------|--------|
|
||||
| vh_ventilationenable | Switch | Ventilation enabled | R |
|
||||
| vh_bypassposition | Number:Dimensionless | Bypass position | R |
|
||||
| vh_bypassmode | Number:Dimensionless | Bypass mode | R |
|
||||
| vh_freeventilationmode | Switch | Free ventilation mode | R |
|
||||
| vh_faultindication | Switch | Fault indication | R |
|
||||
| vh_ventilationmode | Switch | Ventilation mode | R |
|
||||
| vh_bypassstatus | Switch | Bypass status | R |
|
||||
| vh_bypassautomaticstatus | Number:Dimensionless | Bypass automatic status | R |
|
||||
| vh_freeventilationstatus | Switch | Free ventilation status | R |
|
||||
| vh_filtercheck | Switch | Filter Check enabled | R |
|
||||
| vh_diagnosticindication | Switch | Diagnostic indication | R |
|
||||
| vh_controlsetpoint | Number:Dimensionless | Control setpoint | R |
|
||||
| vh_servicerequest | Switch | Service request | R |
|
||||
| vh_exhaustfanfault | Switch | Exhaust fan fault | R |
|
||||
| vh_inletfanfault | Switch | Inlet fan fault | R |
|
||||
| vh_frostprotection | Switch | Frost protection | R |
|
||||
| vh_faultcode | Number:Dimensionless | Fault code | R |
|
||||
| vh_diagnosticcode | Number:Dimensionless | Diagnostic code | R |
|
||||
| vh_systemtype | Number:Dimensionless | System type | R |
|
||||
| vh_bypass | Switch | Bypass | R |
|
||||
| vh_speedcontrol | Number:Dimensionless | Speed control | R |
|
||||
| vh_memberid | Number:Dimensionless | Member ID | R |
|
||||
| vh_openthermversion | Number:Dimensionless | OpenTherm version | R |
|
||||
| vh_versiontype | Number:Dimensionless | Version type | R |
|
||||
| vh_relativeventilation | Number:Dimensionless | Relative ventilation position | R |
|
||||
| vh_relativehumidity | Number:Dimensionless | Relative humidity exhaust air | R |
|
||||
| vh_co2level | Number:Dimensionless | CO2 level exhaust air | R |
|
||||
| vh_supplyinlettemp | Number:Temperature | Supply inlet temperature | R |
|
||||
| vh_supplyoutlettemp | Number:Temperature | Supply outlet temperature | R |
|
||||
| vh_exhaustinlettemp | Number:Temperature | Exhaust inlet temperature | R |
|
||||
| vh_exhaustoutlettemp | Number:Temperature | Exhaust outlet temperature | R |
|
||||
| vh_actualexhaustfanspeed | Number:Dimensionless | Actual exhaust fan speed | R |
|
||||
| vh_actualinletfanspeed | Number:Dimensionless | Actual inlet fan speed | R |
|
||||
| vh_nominalventenable | Switch | Nominal ventilation value transfer enabled | R |
|
||||
| vh_nominalventrw | Number:Dimensionless | Nominal ventilation value | R |
|
||||
| vh_nominalventilationvalue | Number:Dimensionless | Nominal ventilation value | R |
|
||||
| vh_ventilationsetpoint | Number:Dimensionless | Ventilation setpoint override | R/W |
|
||||
| vh_tspnumber | Number:Dimensionless | Number of transparent slave parameter entries | R |
|
||||
| vh_tspentry | Number:Dimensionless | Transparent slave parameter entry | R |
|
||||
| vh_fhbnumber | Number:Dimensionless | Number of fault history buffer entries | R |
|
||||
| vh_fhbentry | Number:Dimensionless | Fault history buffer entry | R |
|
||||
|
||||
## Transparent Slave Parameters and Fault History Buffer channels
|
||||
|
||||
The transparent slave parameters (TSP) and fault history buffer (FHB) use a variable number of entries.
|
||||
The number of entries is determined by a TSP or FHB size message.
|
||||
Channels for TSP and FHB entries are automatically created when a TSP or FHB size message is received.
|
||||
An index number is added to the base channel name to create a unique channel name for each entry.
|
||||
|
||||
For example, if a TSP size message is received for a boiler unit (OpenTherm DATA-ID 10) with value 60, then channels `tspentry_0` through `tspentry_59` will be automatically created and linked to the corresponding TSP entry (OpenTherm DATA-ID 11).
|
||||
|
||||
## Using OpenTherm Gateway as a master device
|
||||
|
||||
When using OpenTherm with a boiler and a thermostat, the thermostat (master) periodically sends messages to the boiler to request data.
|
||||
The boiler (slave) then sends a response message with the requested data which is then used by the OpenTherm Gateway binding to update the channel values in openHAB.
|
||||
|
||||
If you have a setup without a master device requesting data, then the slave device may send fewer or even no OpenTherm mesages at all.
|
||||
|
||||
In this case, you can make the OpenTherm Gateway act as a master device by sending Priority Message (PM) commands.
|
||||
With openHAB rules, you can use the `sendcommand` channel of the `openthermgateway` bridge to periodically send PM commands to the OpenTherm Gateway.
|
||||
|
||||
Example:
|
||||
|
||||
```
|
||||
SendCommand.sendCommand("PM=10")
|
||||
```
|
||||
|
||||
This will cause the OpenTherm Gateway to send a READ-DATA message to the slave device with DATA-ID 10. If supported, the slave device will respond with a READ-ACK message and the current value.
|
||||
|
||||
## Full Example
|
||||
|
||||
### demo.things
|
||||
### demo.things
|
||||
|
||||
```
|
||||
Thing openthermgateway:otgw:1 [ ipaddress="192.168.1.100", port=8000, connectionRetryInterval=60 ]
|
||||
Bridge openthermgateway:openthermgateway:1 "OpenTherm Gateway" [ ipaddress="192.168.1.100", port="8000", connectionRetryInterval=60 ] {
|
||||
Thing boiler remeha "Remeha Avanta 28c"
|
||||
Thing ventilationheatrecovery brink "Brink Renovent Excellent 300"
|
||||
}
|
||||
```
|
||||
|
||||
### demo.items
|
||||
### demo.items for `openthermgateway`
|
||||
|
||||
```
|
||||
Number:Temperature RoomTemperature "Room temperature [%.1f °C]" <temperature> { channel="openthermgateway:otgw:1:roomtemp" }
|
||||
Number:Temperature RoomSetpoint "Room setpoint [%.1f °C]" <temperature> { channel="openthermgateway:otgw:1:roomsetpoint" }
|
||||
Number:Temperature TemporaryRoomSetpointOverride "Temporary room setpoint override [%.1f °C]" <temperature> { channel="openthermgateway:otgw:1:temperaturetemporary" }
|
||||
Number:Temperature ConstantRoomSetpointOverride "Constant room setpoint override [%.1f °C]" <temperature> { channel="openthermgateway:otgw:1:temperatureconstant" }
|
||||
Number:Temperature ControlSetpoint "Control setpoint [%.1f °C]" <temperature> { channel="openthermgateway:otgw:1:controlsetpoint" }
|
||||
Number:Temperature ControlSetpointRequested "Control setpoint requested [%.1f °C]" <temperature> { channel="openthermgateway:otgw:1:controlsetpointrequested" }
|
||||
Number:Temperature ControlSetpointOverride "Control setpoint override [%.1f °C]" <temperature> { channel="openthermgateway:otgw:1:controlsetpointoverride" }
|
||||
Number:Temperature ControlSetpoint2 "Control setpoint 2 [%.1f °C]" <temperature> { channel="openthermgateway:otgw:1:controlsetpoint2" }
|
||||
Number:Temperature ControlSetpoint2Requested "Control setpoint 2 requested [%.1f °C]" <temperature> { channel="openthermgateway:otgw:1:controlsetpoint2requested" }
|
||||
Number:Temperature ControlSetpoint2Override "Control setpoint 2 override [%.1f °C]" <temperature> { channel="openthermgateway:otgw:1:controlsetpoint2override" }
|
||||
Number:Temperature DomesticHotWaterTemperature "Domestic hot water temperature [%.1f °C]" <temperature> { channel="openthermgateway:otgw:1:dhwtemp" }
|
||||
Number:Temperature DomesticHotWaterSetpoint "Domestic hot water setpoint [%.1f °C]" <temperature> { channel="openthermgateway:otgw:1:tdhwset" }
|
||||
Number:Temperature DomesticHotWaterSetpointOverride "Domestic hot water setpoint override [%.1f °C]" <temperature> { channel="openthermgateway:otgw:1:overridedhwsetpoint" }
|
||||
Number:Temperature BoilerWaterTemperature "Boiler water temperature [%.1f °C]" <temperature> { channel="openthermgateway:otgw:1:flowtemp" }
|
||||
Number:Temperature ReturnWaterTemperature "Return water temperature [%.1f °C]" <temperature> { channel="openthermgateway:otgw:1:returntemp" }
|
||||
Number:Temperature OutsideTemperature "Outside temperature [%.1f °C]" <temperature> { channel="openthermgateway:otgw:1:outsidetemp" }
|
||||
Number:Pressure CentralHeatingWaterPressure "Central heating water pressure [%.1f bar]" { channel="openthermgateway:otgw:1:waterpressure" }
|
||||
Switch CentralHeatingEnabled "Central heating enabled" <switch> { channel="openthermgateway:otgw:1:ch_enable" }
|
||||
Switch CentralHeatingEnabledRequested "Central heating enabled requested" <switch> { channel="openthermgateway:otgw:1:ch_enablerequested" }
|
||||
Switch CentralHeatingEnabledOverride "Central heating enabled override" <switch> { channel="openthermgateway:otgw:1:ch_enableoverride" }
|
||||
Switch CentralHeating2Enabled "Central heating 2 enabled" <switch> { channel="openthermgateway:otgw:1:ch2_enable" }
|
||||
Switch CentralHeating2EnabledRequested "Central 2 heating enabled requested" <switch> { channel="openthermgateway:otgw:1:ch2_enablerequested" }
|
||||
Switch CentralHeating2EnabledOverride "Central 2 heating enabled override" <switch> { channel="openthermgateway:otgw:1:ch2_enableoverride" }
|
||||
Switch CentralHeatingActive "Central heating active" <switch> { channel="openthermgateway:otgw:1:ch_mode" }
|
||||
Switch DomesticHotWaterEnabled "Domestic hot water enabled" <switch> { channel="openthermgateway:otgw:1:dhw_enable" }
|
||||
Switch DomesticHotWaterActive "Domestic hot water active" <switch> { channel="openthermgateway:otgw:1:dhw_mode" }
|
||||
Switch BurnerActive "Burner active" <switch> { channel="openthermgateway:otgw:1:flame" }
|
||||
Number:Dimensionless RelativeModulationLevel "Relative modulation level [%.1f %%]" { channel="openthermgateway:otgw:1:modulevel" }
|
||||
Number:Dimensionless MaximumRelativeModulationLevel "Maximum relative modulation level [%.1f %%]" { channel="openthermgateway:otgw:1:maxrelmdulevel" }
|
||||
Switch Fault "Fault indication" <switch> { channel="openthermgateway:otgw:1:fault" }
|
||||
Switch ServiceRequest "Service required" <switch> { channel="openthermgateway:otgw:1:servicerequest" }
|
||||
Switch LockoutReset "Lockout-reset" <switch> { channel="openthermgateway:otgw:1:lockout-reset" }
|
||||
Switch LowWaterPress "Low water pressure fault" <switch> { channel="openthermgateway:otgw:1:lowwaterpress" }
|
||||
Switch GasFlameFault "Gas or flame fault" <switch> { channel="openthermgateway:otgw:1:gasflamefault" }
|
||||
Switch AirPressFault "Air pressure fault" <switch> { channel="openthermgateway:otgw:1:airpressfault" }
|
||||
Switch WaterOvTemp "Water over-temperature fault" <switch> { channel="openthermgateway:otgw:1:waterovtemp" }
|
||||
Number OemFaultCode "OEM fault code" { channel="openthermgateway:otgw:1:oemfaultcode" }
|
||||
Switch Diagnostics "Diagnostics indication" { channel="openthermgateway:otgw:1:diag" }
|
||||
Number:Dimensionless UnsuccessfulBurnerStarts "Unsuccessful burner starts" { channel="openthermgateway:otgw:1:unsuccessfulburnerstarts" }
|
||||
Number:Dimensionless BurnerStarts "Burner starts" { channel="openthermgateway:otgw:1:burnerstarts" }
|
||||
Number:Dimensionless CentralHeatingPumpStarts "Central heating pump starts" { channel="openthermgateway:otgw:1:chpumpstarts" }
|
||||
Number:Dimensionless DomesticHotWaterPumpValveStarts "Domestic hot water pump/valve starts" { channel="openthermgateway:otgw:1:dhwpvstarts" }
|
||||
Number:Dimensionless DomesticHotWaterBurnerStarts "Domestic hot water burner starts" { channel="openthermgateway:otgw:1:dhwburnerstarts" }
|
||||
Number:Time BurnerHours "Burner hours" { channel="openthermgateway:otgw:1:burnerhours" }
|
||||
Number:Time CentralHeatingPumpHours "Central heating pump hours" { channel="openthermgateway:otgw:1:chpumphours" }
|
||||
Number:Time DomesticHotWaterPumpValveHours "Domestic hot water pump/valve hours" { channel="openthermgateway:otgw:1:dhwpvhours" }
|
||||
Number:Time DomesticHotWaterBurnerHours "Domestic hot water burner hours" { channel="openthermgateway:otgw:1:dhwburnerhours" }
|
||||
Text SendCommand "Send command channel" { channel="openthermgateway:otgw:1:sendcommand" }
|
||||
Text SendCommand "Send command channel" { channel="openthermgateway:openthermgateway:1:sendcommand" }
|
||||
```
|
||||
|
||||
### demo.items for `boiler`
|
||||
|
||||
```
|
||||
Number:Temperature RoomTemperature "Room Temperature [%.1f %unit%]" <temperature> { channel="openthermgateway:boiler:1:remeha:roomtemp }
|
||||
Number:Temperature RoomSetpoint "Room Setpoint [%.1f %unit%]" <temperature> { channel="openthermgateway:boiler:1:remeha:roomsetpoint }
|
||||
Number:Temperature TemporaryRoomSetpointOverride "Temporary Room Setpoint Override [%.1f %unit%]" <temperature> { channel="openthermgateway:boiler:1:remeha:temperaturetemporary }
|
||||
Number:Temperature ConstantRoomSetpointOverride "Constant Room Setpoint Override [%.1f %unit%]" <temperature> { channel="openthermgateway:boiler:1:remeha:temperatureconstant }
|
||||
Number:Temperature ControlSetpoint "Control Setpoint [%.1f %unit%]" <temperature> { channel="openthermgateway:boiler:1:remeha:controlsetpoint }
|
||||
Number:Temperature ControlSetpointRequested "Control Setpoint Requested [%.1f %unit%]" <temperature> { channel="openthermgateway:boiler:1:remeha:controlsetpointrequested }
|
||||
Number:Temperature ControlSetpointOverride "Control Setpoint Override [%.1f %unit%]" <temperature> { channel="openthermgateway:boiler:1:remeha:controlsetpointoverride }
|
||||
Number:Temperature ControlSetpoint2 "Control Setpoint 2 [%.1f %unit%]" <temperature> { channel="openthermgateway:boiler:1:remeha:controlsetpoint2 }
|
||||
Number:Temperature ControlSetpoint2Requested "Control Setpoint 2 Requested [%.1f %unit%]" <temperature> { channel="openthermgateway:boiler:1:remeha:controlsetpoint2requested }
|
||||
Number:Temperature ControlSetpoint2Override "Control Setpoint 2 Override [%.1f %unit%]" <temperature> { channel="openthermgateway:boiler:1:remeha:controlsetpoint2override }
|
||||
Number:Temperature DomesticHotWaterTemperature "Domestic Hot Water Temperature [%.1f %unit%]" <temperature> { channel="openthermgateway:boiler:1:remeha:dhwtemp }
|
||||
Number:Temperature DomesticHotWaterSetpoint "Domestic Hot Water Setpoint [%.1f %unit%]" <temperature> { channel="openthermgateway:boiler:1:remeha:tdhwset }
|
||||
Number:Temperature DomesticHotWaterSetpointOverride "Domestic Hot Water Setpoint Override [%.1f %unit%]" <temperature> { channel="openthermgateway:boiler:1:remeha:overridedhwsetpoint }
|
||||
Number:Temperature BoilerWaterTemperature "Boiler Water Temperature [%.1f %unit%]" <temperature> { channel="openthermgateway:boiler:1:remeha:flowtemp }
|
||||
Number:Temperature ReturnWaterTemperature "Return Water Temperature [%.1f %unit%]" <temperature> { channel="openthermgateway:boiler:1:remeha:returntemp }
|
||||
Number:Temperature OutsideTemperature "Outside Temperature [%.1f %unit%]" <temperature> { channel="openthermgateway:boiler:1:remeha:outsidetemp }
|
||||
Number:Dimensionless CentralHeatingWaterPressure "Central Heating Water Pressure [%.1f bar]" { channel="openthermgateway:boiler:1:remeha:waterpressure }
|
||||
Switch CentralHeatingEnabled "Central Heating Enabled" <switch> { channel="openthermgateway:boiler:1:remeha:ch_enable }
|
||||
Switch CentralHeatingEnabledThermostat "Central Heating Enabled Thermostat" <switch> { channel="openthermgateway:boiler:1:remeha:ch_enablerequested }
|
||||
Switch CentralHeatingOverridden "Central Heating Overridden" <switch> { channel="openthermgateway:boiler:1:remeha:ch_enableoverride }
|
||||
Switch CentralHeating2Enabled "Central Heating 2 Enabled" <switch> { channel="openthermgateway:boiler:1:remeha:ch2_enable }
|
||||
Switch CentralHeating2EnabledThermostat "Central Heating 2 Enabled Thermostat" <switch> { channel="openthermgateway:boiler:1:remeha:ch2_enablerequested }
|
||||
Switch CentralHeating2Overridden "Central Heating 2 Overridden" <switch> { channel="openthermgateway:boiler:1:remeha:ch2_enableoverride }
|
||||
Switch CentralHeatingActive "Central Heating Active" <switch> { channel="openthermgateway:boiler:1:remeha:ch_mode }
|
||||
Switch DomesticHotWaterEnabled "Domestic Hot Water Enabled" <switch> { channel="openthermgateway:boiler:1:remeha:dhw_enable }
|
||||
Switch DomesticHotWaterActive "Domestic Hot Water Active" <switch> { channel="openthermgateway:boiler:1:remeha:dhw_mode }
|
||||
Switch BurnerActive "Burner Active" <switch> { channel="openthermgateway:boiler:1:remeha:flame }
|
||||
Number:Dimensionless RelativeModulationLevel "Relative Modulation Level [%.1f %%]" { channel="openthermgateway:boiler:1:remeha:modulevel }
|
||||
Number:Dimensionless MaximumRelativeModulationLevel "Maximum Relative Modulation Level [%.1f %%]" { channel="openthermgateway:boiler:1:remeha:maxrelmdulevel }
|
||||
Switch FaultIndication "Fault Indication" <switch> { channel="openthermgateway:boiler:1:remeha:fault }
|
||||
Switch ServiceRequired "Service Required" <switch> { channel="openthermgateway:boiler:1:remeha:servicerequest }
|
||||
Switch LockoutResetEnabled "Lockout-Reset Enabled" <switch> { channel="openthermgateway:boiler:1:remeha:lockout-reset }
|
||||
Switch LowWaterPressureFault "Low Water Pressure Fault" <switch> { channel="openthermgateway:boiler:1:remeha:lowwaterpress }
|
||||
Switch GasOrFlameFault "Gas Or Flame Fault" <switch> { channel="openthermgateway:boiler:1:remeha:gasflamefault }
|
||||
Switch AirPressureFault "Air Pressure Fault" <switch> { channel="openthermgateway:boiler:1:remeha:airpressfault }
|
||||
Switch WaterOverTemperatureFault "Water Over-Temperature Fault" <switch> { channel="openthermgateway:boiler:1:remeha:waterovtemp }
|
||||
Number:Dimensionless OEMFaultCode "OEM Fault Code" { channel="openthermgateway:boiler:1:remeha:oemfaultcode }
|
||||
Number:Dimensionless UnsuccessfulBurnerStarts "Unsuccessful Burner Starts" { channel="openthermgateway:boiler:1:remeha:unsuccessfulburnerstarts }
|
||||
Number:Dimensionless BurnerStarts "Burner Starts" { channel="openthermgateway:boiler:1:remeha:burnerstarts }
|
||||
Number:Dimensionless CentralHeatingPumpStarts "Central Heating Pump Starts" { channel="openthermgateway:boiler:1:remeha:chpumpstarts }
|
||||
Number:Dimensionless DomesticHotWaterPump/ValveStarts "Domestic Hot Water Pump/Valve Starts" { channel="openthermgateway:boiler:1:remeha:dhwpvstarts }
|
||||
Number:Dimensionless DomesticHotWaterBurnerStarts "Domestic Hot Water Burner Starts" { channel="openthermgateway:boiler:1:remeha:dhwburnerstarts }
|
||||
Number:Time BurnerHours "Burner Hours" { channel="openthermgateway:boiler:1:remeha:burnerhours }
|
||||
Number:Time CentralHeatingPumpHours "Central Heating Pump Hours" { channel="openthermgateway:boiler:1:remeha:chpumphours }
|
||||
Number:Time DomesticHotWaterPumpValveHours "Domestic Hot Water Pump/Valve Hours" { channel="openthermgateway:boiler:1:remeha:dhwpvhours }
|
||||
Number:Time DomesticHotWaterBurnerHours "Domestic Hot Water Burner Hours" { channel="openthermgateway:boiler:1:remeha:dhwburnerhours }
|
||||
Number:Dimensionless TransparentSlaveParameterNumber "Transparent Slave Parameter Number" { channel="openthermgateway:boiler:1:remeha:tspnumber }
|
||||
Number:Dimensionless TransparentSlaveParameterEntry "Transparent Slave Parameter Entry" { channel="openthermgateway:boiler:1:remeha:tspentry }
|
||||
Number:Dimensionless FaultHistoryBufferNumber "Fault History Buffer Number" { channel="openthermgateway:boiler:1:remeha:fhbnumber }
|
||||
Number:Dimensionless FaultHistoryBufferEntry "Fault History Buffer Entry" { channel="openthermgateway:boiler:1:remeha:fhbentry }
|
||||
```
|
||||
|
||||
### demo.items for `ventilationheatrecovery`
|
||||
|
||||
```
|
||||
Switch VentilationEnabled "Ventilation Enabled" <switch> { channel="openthermgateway:ventilationheatrecovery:1:brink:vh_ventilationenable }
|
||||
Number:Dimensionless BypassPosition "Bypass Position" { channel="openthermgateway:ventilationheatrecovery:1:brink:vh_bypassposition }
|
||||
Number:Dimensionless BypassMode "Bypass Mode" { channel="openthermgateway:ventilationheatrecovery:1:brink:vh_bypassmode }
|
||||
Switch FreeVentilationMode "Free Ventilation Mode" <switch> { channel="openthermgateway:ventilationheatrecovery:1:brink:vh_freeventilationmode }
|
||||
Switch FaultIndication "Fault Indication" <switch> { channel="openthermgateway:ventilationheatrecovery:1:brink:vh_faultindication }
|
||||
Switch VentilationMode "Ventilation Mode" <switch> { channel="openthermgateway:ventilationheatrecovery:1:brink:vh_ventilationmode }
|
||||
Switch BypassStatus "Bypass Status" <switch> { channel="openthermgateway:ventilationheatrecovery:1:brink:vh_bypassstatus }
|
||||
Number:Dimensionless BypassAutomaticStatus "Bypass Automatic Status" { channel="openthermgateway:ventilationheatrecovery:1:brink:vh_bypassautomaticstatus }
|
||||
Switch FreeVentilationStatus "Free Ventilation Status" <switch> { channel="openthermgateway:ventilationheatrecovery:1:brink:vh_freeventilationstatus }
|
||||
Switch FilterCheck "Filter Check" <switch> { channel="openthermgateway:ventilationheatrecovery:1:brink:vh_filtercheck }
|
||||
Switch DiagnosticIndication "Diagnostic Indication" <switch> { channel="openthermgateway:ventilationheatrecovery:1:brink:vh_diagnosticindication }
|
||||
Number:Dimensionless ControlSetpoint "Control Setpoint" { channel="openthermgateway:ventilationheatrecovery:1:brink:vh_controlsetpoint }
|
||||
Switch ServiceRequest "Service Request" <switch> { channel="openthermgateway:ventilationheatrecovery:1:brink:vh_servicerequest }
|
||||
Switch ExhaustFanFault "Exhaust Fan Fault" <switch> { channel="openthermgateway:ventilationheatrecovery:1:brink:vh_exhaustfanfault }
|
||||
Switch InletFanFault "Inlet Fan Fault" <switch> { channel="openthermgateway:ventilationheatrecovery:1:brink:vh_inletfanfault }
|
||||
Switch FrostProtection "Frost Protection" <switch> { channel="openthermgateway:ventilationheatrecovery:1:brink:vh_frostprotection }
|
||||
Number:Dimensionless FaultCode "Fault Code" { channel="openthermgateway:ventilationheatrecovery:1:brink:vh_faultcode }
|
||||
Number:Dimensionless DiagnosticCode "Diagnostic Code" { channel="openthermgateway:ventilationheatrecovery:1:brink:vh_diagnosticcode }
|
||||
Number:Dimensionless SystemType "System Type" { channel="openthermgateway:ventilationheatrecovery:1:brink:vh_systemtype }
|
||||
Switch Bypass "Bypass" <switch> { channel="openthermgateway:ventilationheatrecovery:1:brink:vh_bypass }
|
||||
Number:Dimensionless SpeedControl "Speed Control" { channel="openthermgateway:ventilationheatrecovery:1:brink:vh_speedcontrol }
|
||||
Number:Dimensionless MemberID "Member ID" { channel="openthermgateway:ventilationheatrecovery:1:brink:vh_memberid }
|
||||
Number:Dimensionless OpenThermVersion "OpenTherm Version" { channel="openthermgateway:ventilationheatrecovery:1:brink:vh_openthermversion }
|
||||
Number:Dimensionless VersionType "Version Type" { channel="openthermgateway:ventilationheatrecovery:1:brink:vh_versiontype }
|
||||
Number:Dimensionless RelativeVentilation "Relative Ventilation [%d %%]" { channel="openthermgateway:ventilationheatrecovery:1:brink:vh_relativeventilation }
|
||||
Number:Dimensionless RelativeHumidity "Relative Humidity [%d %%]" { channel="openthermgateway:ventilationheatrecovery:1:brink:vh_relativehumidity }
|
||||
Number:Dimensionless CO2Level "CO2 Level [%d ppm]" { channel="openthermgateway:ventilationheatrecovery:1:brink:vh_co2level }
|
||||
Number:Temperature SupplyInletTemperature "Supply Inlet Temperature [%.1f %unit%]" { channel="openthermgateway:ventilationheatrecovery:1:brink:vh_supplyinlettemp }
|
||||
Number:Temperature SupplyOutletTemperature "Supply Outlet Temperature [%.1f %unit%]" { channel="openthermgateway:ventilationheatrecovery:1:brink:vh_supplyoutlettemp }
|
||||
Number:Temperature ExhaustInletTemperature "Exhaust Inlet Temperature [%.1f %unit%]" { channel="openthermgateway:ventilationheatrecovery:1:brink:vh_exhaustinlettemp }
|
||||
Number:Temperature ExhaustOutletTemperature "Exhaust Outlet Temperature [%.1f %unit%]" { channel="openthermgateway:ventilationheatrecovery:1:brink:vh_exhaustoutlettemp }
|
||||
Number:Dimensionless ActualExhaustFanSpeed "Actual Exhaust Fan Speed [%d rpm]" { channel="openthermgateway:ventilationheatrecovery:1:brink:vh_actualexhaustfanspeed }
|
||||
Number:Dimensionless ActualInletFanSpeed "Actual Inlet Fan Speed [%d rpm]" { channel="openthermgateway:ventilationheatrecovery:1:brink:vh_actualinletfanspeed }
|
||||
Switch NominalVentilationValueTransfer "Nominal Ventilation Value Transfer" <switch> { channel="openthermgateway:ventilationheatrecovery:1:brink:vh_nominalventenable }
|
||||
Number:Dimensionless NominalVentilationValue "Nominal Ventilation Value" { channel="openthermgateway:ventilationheatrecovery:1:brink:vh_nominalventrw }
|
||||
Number:Dimensionless NominalVentilationValue "Nominal Ventilation Value [%d %%]" { channel="openthermgateway:ventilationheatrecovery:1:brink:vh_nominalventilationvalue }
|
||||
Number:Dimensionless VentilationSetpoint "Ventilation Setpoint" { channel="openthermgateway:ventilationheatrecovery:1:brink:vh_ventilationsetpoint }
|
||||
Number:Dimensionless TransparentSlaveParameterNumber "Transparent Slave Parameter Number" { channel="openthermgateway:ventilationheatrecovery:1:brink:vh_tspnumber }
|
||||
Number:Dimensionless TransparentSlaveParameterEntry "Transparent Slave Parameter Entry" { channel="openthermgateway:ventilationheatrecovery:1:brink:vh_tspentry }
|
||||
Number:Dimensionless FaultHistoryBufferNumber "Fault History Buffer Number" { channel="openthermgateway:ventilationheatrecovery:1:brink:vh_fhbnumber }
|
||||
Number:Dimensionless FaultHistoryBufferEntry "Fault History Buffer Entry" { channel="openthermgateway:ventilationheatrecovery:1:brink:vh_fhbentry }
|
||||
```
|
||||
|
||||
### demo.sitemap
|
||||
|
||||
```
|
||||
sitemap demo label="Main Menu" {
|
||||
Frame label="OpenTherm Gateway" {
|
||||
Text item="RoomTemperature" icon="temperature" label="Room temperature [%.1f °C]"
|
||||
Text item="RoomSetpoint" icon="temperature" label="Room setpoint [%.1f °C]"
|
||||
Setpoint item="TemporaryRoomSetpointOverride" icon="temperature" label="Temporary room setpoint override [%.1f °C]" minValue="0" maxValue="30" step="0.1"
|
||||
Setpoint item="ConstantRoomSetpointOverride" icon="temperature" label="Constant room setpoint override [%.1f °C]" minValue="0" maxValue="30" step="0.1"
|
||||
Text item="ControlSetpoint" icon="temperature" label="Control setpoint [%.1f °C]"
|
||||
Text item="ControlSetpointRequested" icon="temperature" label="Control setpoint requested [%.1f °C]"
|
||||
Setpoint item="ControlSetpointOverride" icon="temperature" label="Control setpoint override [%.1f °C]" minValue="0" maxValue="100" step="1"
|
||||
Text item="DomesticHotWaterTemperature" icon="temperature" label="Domestic hot water temperature [%.1f °C]"
|
||||
Text item="DomesticHotWaterSetpoint" icon="temperature" label="Domestic hot water setpoint [%.1f °C]"
|
||||
Setpoint item="DomesticHotWaterSetpointOverride" icon="temperature" label="Domestic hot water setpoint override [%.1f °C]" minValue="0" maxValue="100" step="0.1"
|
||||
Text item="BoilerWaterTemperature" icon="temperature" label="Boiler water temperature [%.1f °C]"
|
||||
Text item="ReturnWaterTemperature" icon="temperature" label="Return water temperature [%.1f °C]"
|
||||
Setpoint item="OutsideTemperature" icon="temperature" label="Outside temperature [%.1f °C]" minValue="-40" maxValue="100" step="0.1"
|
||||
Text item="CentralHeatingWaterPressure" icon="" label="Central heating water pressure [%.1f bar]"
|
||||
Switch item="CentralHeatingEnabled" icon="switch" label="Central heating enabled"
|
||||
Switch item="CentralHeatingEnabledRequested" icon="switch" label="Central heating enabled requested"
|
||||
Switch item="CentralHeatingEnabledOverride" icon="switch" label="Central heating enabled override"
|
||||
Switch item="CentralHeatingActive" icon="switch" label="Central heating active"
|
||||
Switch item="DomesticHotWaterEnabled" icon="switch" label="Domestic hot water enabled"
|
||||
Switch item="DomesticHotWaterActive" icon="switch" label="Domestic hot water active"
|
||||
Switch item="BurnerActive" icon="switch" label="Burner active"
|
||||
Text item="RelativeModulationLevel" icon="" label="Relative modulation level [%.1f %%]"
|
||||
Text item="MaximumRelativeModulationLevel" icon="" label="Maximum relative modulation level [%.1f %%]"
|
||||
Switch item="Fault" icon="" label="Fault indication"
|
||||
Switch item="ServiceRequest" icon="" label="Service required"
|
||||
Switch item="LockoutReset" icon="" label="Lockout-reset"
|
||||
Switch item="LowWaterPress" icon="" label="Low water pressure fault"
|
||||
Switch item="GasFlameFault" icon="" label="Gas or flame fault"
|
||||
Switch item="AirPressFault" icon="" label="Air pressure fault"
|
||||
Switch item="waterOvTemp" icon="" label="Water over-temperature fault"
|
||||
Text item="OemFaultCode" icon="" label="OEM fault code"
|
||||
Switch item="Diagnostics" icon="" label="Diagnostics indication"
|
||||
Text item="UnsuccessfulBurnerStarts" icon="" label="Unsuccessful burner starts"
|
||||
Text item="BurnerStarts" icon="" label="Burner starts"
|
||||
Text item="CentralHeatingPumpStarts" icon="" label="Central heating pump starts"
|
||||
Text item="DomesticHotWaterPumpValveStarts" icon="" label="Domestic hot water pump/valve starts"
|
||||
Text item="DomesticHotWaterBurnerStarts" icon="" label="Domestic hot water burner starts"
|
||||
Text item="BurnerHours" icon="" label="Burner hours"
|
||||
Text item="CentralHeatingPumpHours" icon="" label="Central heating pump hours"
|
||||
Text item="DomesticHotWaterPumpValveHours" icon="" label="Domestic hot water pump/valve hours"
|
||||
Text item="DomesticHotWaterBurnerHours" icon="" label="Domestic hot water burner hours"
|
||||
Frame label="Boiler" {
|
||||
Text item="RoomTemperature" icon="temperature" label="Room Temperature [%.1f %unit%]"
|
||||
Text item="RoomSetpoint" icon="temperature" label="Room Setpoint [%.1f %unit%]"
|
||||
Text item="TemporaryRoomSetpointOverride" icon="temperature" label="Temporary Room Setpoint Override [%.1f %unit%]" minValue="0" maxValue="30" step="0.1"
|
||||
Text item="ConstantRoomSetpointOverride" icon="temperature" label="Constant Room Setpoint Override [%.1f %unit%]" minValue="0" maxValue="30" step="0.1"
|
||||
Text item="ControlSetpoint" icon="temperature" label="Control Setpoint [%.1f %unit%]"
|
||||
Text item="ControlSetpointRequested" icon="temperature" label="Control Setpoint Requested [%.1f %unit%]"
|
||||
Text item="ControlSetpointOverride" icon="temperature" label="Control Setpoint Override [%.1f %unit%]" minValue="0" maxValue="100" step="0.1"
|
||||
Text item="ControlSetpoint2" icon="temperature" label="Control Setpoint 2 [%.1f %unit%]"
|
||||
Text item="ControlSetpoint2Requested" icon="temperature" label="Control Setpoint 2 Requested [%.1f %unit%]"
|
||||
Text item="ControlSetpoint2Override" icon="temperature" label="Control Setpoint 2 Override [%.1f %unit%]" minValue="0" maxValue="100" step="0.1"
|
||||
Text item="DomesticHotWaterTemperature" icon="temperature" label="Domestic Hot Water Temperature [%.1f %unit%]"
|
||||
Text item="DomesticHotWaterSetpoint" icon="temperature" label="Domestic Hot Water Setpoint [%.1f %unit%]"
|
||||
Text item="DomesticHotWaterSetpointOverride" icon="temperature" label="Domestic Hot Water Setpoint Override [%.1f %unit%]" minValue="0" maxValue="100" step="0.1"
|
||||
Text item="BoilerWaterTemperature" icon="temperature" label="Boiler Water Temperature [%.1f %unit%]"
|
||||
Text item="ReturnWaterTemperature" icon="temperature" label="Return Water Temperature [%.1f %unit%]"
|
||||
Text item="OutsideTemperature" icon="temperature" label="Outside Temperature [%.1f %unit%]" minValue="-40" maxValue="100" step="0.1"
|
||||
Text item="CentralHeatingWaterPressure" label="Central Heating Water Pressure [%.1f bar]"
|
||||
Switch item="CentralHeatingEnabled" icon="switch" label="Central Heating Enabled"
|
||||
Switch item="CentralHeatingEnabledThermostat" icon="switch" label="Central Heating Enabled Thermostat"
|
||||
Switch item="CentralHeatingOverridden" icon="switch" label="Central Heating Overridden"
|
||||
Switch item="CentralHeating2Enabled" icon="switch" label="Central Heating 2 Enabled"
|
||||
Switch item="CentralHeating2EnabledThermostat" icon="switch" label="Central Heating 2 Enabled Thermostat"
|
||||
Switch item="CentralHeating2Overridden" icon="switch" label="Central Heating 2 Overridden"
|
||||
Switch item="CentralHeatingActive" icon="switch" label="Central Heating Active"
|
||||
Switch item="DomesticHotWaterEnabled" icon="switch" label="Domestic Hot Water Enabled"
|
||||
Switch item="DomesticHotWaterActive" icon="switch" label="Domestic Hot Water Active"
|
||||
Switch item="BurnerActive" icon="switch" label="Burner Active"
|
||||
Text item="RelativeModulationLevel" label="Relative Modulation Level [%.1f %%]"
|
||||
Text item="MaximumRelativeModulationLevel" label="Maximum Relative Modulation Level [%.1f %%]"
|
||||
Switch item="FaultIndication" icon="switch" label="Fault Indication"
|
||||
Switch item="ServiceRequired" icon="switch" label="Service Required"
|
||||
Switch item="Lockout-ResetEnabled" icon="switch" label="Lockout-Reset Enabled"
|
||||
Switch item="LowWaterPressureFault" icon="switch" label="Low Water Pressure Fault"
|
||||
Switch item="GasOrFlameFault" icon="switch" label="Gas Or Flame Fault"
|
||||
Switch item="AirPressureFault" icon="switch" label="Air Pressure Fault"
|
||||
Switch item="WaterOver-TemperatureFault" icon="switch" label="Water Over-Temperature Fault"
|
||||
Text item="OEMFaultCode" label="OEM Fault Code"
|
||||
Text item="UnsuccessfulBurnerStarts" label="Unsuccessful Burner Starts"
|
||||
Text item="BurnerStarts" label="Burner Starts"
|
||||
Text item="CentralHeatingPumpStarts" label="Central Heating Pump Starts"
|
||||
Text item="DomesticHotWaterPump/ValveStarts" label="Domestic Hot Water Pump/Valve Starts"
|
||||
Text item="DomesticHotWaterBurnerStarts" label="Domestic Hot Water Burner Starts"
|
||||
Text item="BurnerHours" label="Burner Hours"
|
||||
Text item="CentralHeatingPumpHours" label="Central Heating Pump Hours"
|
||||
Text item="DomesticHotWaterPumpValveHours" label="Domestic Hot Water Pump/Valve Hours"
|
||||
Text item="DomesticHotWaterBurnerHours" label="Domestic Hot Water Burner Hours"
|
||||
Text item="TransparentSlaveParameterNumber" label="Transparent Slave Parameter Number"
|
||||
Text item="TransparentSlaveParameterEntry" label="Transparent Slave Parameter Entry"
|
||||
Text item="FaultHistoryBufferNumber" label="Fault History Buffer Number"
|
||||
Text item="FaultHistoryBufferEntry" label="Fault History Buffer Entry"
|
||||
}
|
||||
}
|
||||
|
||||
Frame label="Ventilation / Heat Recovery" {
|
||||
Switch item="VentilationEnabled" icon="switch" label="Ventilation Enabled"
|
||||
Text item="BypassPosition" label="Bypass Position"
|
||||
Text item="BypassMode" label="Bypass Mode"
|
||||
Switch item="FreeVentilationMode" icon="switch" label="Free Ventilation Mode"
|
||||
Switch item="FaultIndication" icon="switch" label="Fault Indication"
|
||||
Switch item="VentilationMode" icon="switch" label="Ventilation Mode"
|
||||
Switch item="BypassStatus" icon="switch" label="Bypass Status"
|
||||
Text item="BypassAutomaticStatus" label="Bypass Automatic Status"
|
||||
Switch item="FreeVentilationStatus" icon="switch" label="Free Ventilation Status"
|
||||
Switch item="FilterCheck" icon="switch" label="Filter Check"
|
||||
Switch item="DiagnosticIndication" icon="switch" label="Diagnostic Indication"
|
||||
Text item="ControlSetpoint" label="Control Setpoint"
|
||||
Switch item="ServiceRequest" icon="switch" label="Service Request"
|
||||
Switch item="ExhaustFanFault" icon="switch" label="Exhaust Fan Fault"
|
||||
Switch item="InletFanFault" icon="switch" label="Inlet Fan Fault"
|
||||
Switch item="FrostProtection" icon="switch" label="Frost Protection"
|
||||
Text item="FaultCode" label="Fault Code"
|
||||
Text item="DiagnosticCode" label="Diagnostic Code"
|
||||
Text item="SystemType" label="System Type"
|
||||
Switch item="Bypass" icon="switch" label="Bypass"
|
||||
Text item="SpeedControl" label="Speed Control"
|
||||
Text item="MemberID" label="Member ID"
|
||||
Text item="OpenThermVersion" label="OpenTherm Version"
|
||||
Text item="VersionType" label="Version Type"
|
||||
Text item="RelativeVentilation" label="Relative Ventilation [%d %%]"
|
||||
Text item="RelativeHumidity" label="Relative Humidity [%d %%]"
|
||||
Text item="CO2Level" label="CO2 Level [%d ppm]"
|
||||
Text item="SupplyInletTemperature" label="Supply Inlet Temperature [%.1f %unit%]"
|
||||
Text item="SupplyOutletTemperature" label="Supply Outlet Temperature [%.1f %unit%]"
|
||||
Text item="ExhaustInletTemperature" label="Exhaust Inlet Temperature [%.1f %unit%]"
|
||||
Text item="ExhaustOutletTemperature" label="Exhaust Outlet Temperature [%.1f %unit%]"
|
||||
Text item="ActualExhaustFanSpeed" label="Actual Exhaust Fan Speed [%d rpm]"
|
||||
Text item="ActualInletFanSpeed" label="Actual Inlet Fan Speed [%d rpm]"
|
||||
Switch item="NominalVentilationValueTransfer" icon="switch" label="Nominal Ventilation Value Transfer"
|
||||
Text item="NominalVentilationValue" label="Nominal Ventilation Value"
|
||||
Text item="NominalVentilationValue" label="Nominal Ventilation Value [%d %%]"
|
||||
Text item="VentilationSetpoint" label="Ventilation Setpoint" minValue="0" maxValue="100" step="1"
|
||||
Text item="TransparentSlaveParameterNumber" label="Transparent Slave Parameter Number"
|
||||
Text item="TransparentSlaveParameterEntry" label="Transparent Slave Parameter Entry"
|
||||
Text item="FaultHistoryBufferNumber" label="Fault History Buffer Number"
|
||||
Text item="FaultHistoryBufferEntry" label="Fault History Buffer Entry"
|
||||
}
|
||||
}
|
||||
```
|
||||
|
||||
## Migration from Prior Versions of the Binding
|
||||
|
||||
Between openHAB v3.2 and v3.3 the structure of Things and Channels was changed.
|
||||
This means that Things and their respective Channels and Items that were created on v3.2 or earlier will no longer function on version v3.3 or later.
|
||||
To be specific the change is as follows..
|
||||
|
||||
- **openHAB Versions v3.2 or earlier**: There was just one single `otgw` Thing that combined the functions that communicate with the OpenTherm Gateway together with the functions of the Channels that monitor/control the connected Boiler.
|
||||
|
||||
- **openHAB Versions v3.3 or later**: The communication functions have been moved to a new `openthermgateway` Bridge Thing. The connected Boiler functions have been moved to a new `boiler` Thing. And in addition (if needed) new functions for a connected Ventilation / Heat-Recovery system have been added in a new `ventilationheatrecovery` Thing.
|
||||
|
||||
So if you upgrade your system from openHAB v3.2 (or lower) to v3.3 (or higher), then your Thing and Item definitions must be migrated as shown below..
|
||||
|
||||
- Divide the contents of your old `openthermgateway:otgw:yourGatewayId` Thing definition into two new parts, namely 1) a new `openthermgateway:openthermgateway:yourGatewayId` Bridge definition for the OpenTherm Gateway, and 2) a new `openthermgateway:boiler:yourGatewayId:yourBoilerId` Thing definition for the connected Boiler.
|
||||
|
||||
- Change the `channel=".."` configuration entries of all your Items from referring to the ThingUID of the old `otgw` Thing to refer instead to the ThingUID of the respective newly created `boiler` Thing.
|
||||
|
||||
**Old Thing Definition and respective Item Definition (example)**
|
||||
|
||||
```
|
||||
Thing openthermgateway:otgw:yourGatewayId [ ipaddress="192.168.1.100", port=8000, connectionRetryInterval=60 ]
|
||||
|
||||
e.g.
|
||||
Number:Temperature Boiler_DHW_Temperature "Boiler DHW Temperature [%.1f %unit%]" <temperature> {channel="openthermgateway:otgw:yourGatewayId:dhwtemp"}
|
||||
&c.
|
||||
```
|
||||
|
||||
**New Thing Definition and respective and Item Definition (example)**
|
||||
|
||||
```
|
||||
Bridge openthermgateway:openthermgateway:yourGatewayId "OpenTherm Gateway" @ "Kitchen" [ipaddress="192.168.1.100", port=20108, connectionRetryInterval=60] {
|
||||
Thing boiler remeha "Boiler" @ "Kitchen"
|
||||
}
|
||||
|
||||
e.g.
|
||||
Number:Temperature Boiler_DHW_Temperature "Boiler DHW Temperature [%.1f %unit%]" <temperature> {channel="openthermgateway:boiler:yourGatewayId:remeha:dhwtemp"}
|
||||
&c.
|
||||
```
|
||||
|
||||