[avmfritz] Added support for DECT440 device (#8588)
Signed-off-by: Christoph Weitkamp <github@christophweitkamp.de>
This commit is contained in:
committed by
GitHub
parent
64a713e74a
commit
bff1810aec
@@ -1,6 +1,8 @@
|
||||
# AVM FRITZ! Binding
|
||||
|
||||
The binding integrates AVM FRITZ!Boxes with a special focus on the AHA ( [AVM Home Automation](https://avm.de/ratgeber/smart-home/) ) features.
|
||||
The binding integrates AVM FRITZ!Boxes with a special focus on the AHA ([AVM Home Automation](https://avm.de/ratgeber/filter/smart-home/)) features.
|
||||
|
||||

|
||||
|
||||
## Supported Things
|
||||
|
||||
@@ -26,23 +28,34 @@ It only supports temperature readings.
|
||||
|
||||
### FRITZ!Powerline 546E
|
||||
|
||||
This [powerline adapter](https://avm.de/produkte/fritzpowerline/fritzpowerline-546e/) can be used via the bridge or in stand-alone mode.
|
||||
This [powerline adapter](https://avm.de/produkte/fritzpowerline/) can be used via the bridge or in stand-alone mode.
|
||||
It supports switching the outlet and reading the current power, current voltage and accumulated energy consumption.
|
||||
This device does not contain a temperature sensor.
|
||||
**NOTE:** The `voltage` channel will be added to the thing during runtime - if the interface supports it (FRITZ!OS 7 or higher).
|
||||
|
||||
### FRITZ!DECT 301 / FRITZ!DECT 300 / Comet DECT
|
||||
|
||||
These devices [FRITZ!DECT 301](https://avm.de/produkte/fritzdect/fritzdect-301/), FRITZ!DECT 300 and [Comet DECT](https://www.eurotronic.org/produkte/comet-dect.html) ( [EUROtronic Technology GmbH](https://www.eurotronic.org) ) are used to regulate radiators via DECT protocol.
|
||||
These devices [FRITZ!DECT 301](https://avm.de/produkte/fritzdect/fritzdect-301/), FRITZ!DECT 300 and [Comet DECT](https://eurotronic.org/produkte/dect-ule-heizkoerperthermostat/comet-dect/) ([EUROtronic Technology GmbH](https://eurotronic.org/)) are used to regulate radiators via DECT-ULE protocol.
|
||||
The FRITZ!Box can handle up to twelve heating thermostats.
|
||||
The binding provides channels for reading and setting the temperature.
|
||||
Additionally you can check the eco temperature, the comfort temperature and the battery level of the device.
|
||||
The FRITZ!Box has to run at least on firmware FRITZ!OS 6.35.
|
||||
**NOTE:** The `battery_level` channel will be added to the thing during runtime - if the interface supports it (FRITZ!OS 7 or higher).
|
||||
|
||||
### FRITZ!DECT 400
|
||||
### FRITZ!DECT 400 / FRITZ!DECT 440
|
||||
|
||||
The [FRITZ!DECT 400](https://avm.de/produkte/fritzdect/fritzdect-400/) is a button for convenient operation of FRITZ! Smart Home devices (FRITZ!OS 7.08 or higher).
|
||||
The [FRITZ!DECT 400](https://avm.de/produkte/fritzdect/fritzdect-400/) and [FRITZ!DECT 440](https://avm.de/produkte/fritzdect/fritzdect-440/) are buttons for convenient operation of FRITZ! Smart Home devices (FRITZ!OS 7.08 or higher for FRITZ!DECT 400, 7.20 or higher for FRITZ!DECT 440).
|
||||
The FRITZ!DECT 400 supports a configurable button to trigger short or long press events.
|
||||
Beside four customizable buttons the FRITZ!DECT 440 supports temperature readings.
|
||||
** NOTE: ** FRITZ!DECT 440 now uses Channel Groups to group its Channels like `device#battery_level`, `device#battery_low` for device information, `sensors#temperature` for sensor data and `top-left`, `bottom-left`, `top-right` and `bottom-right` combined with `press` and `last_change` (see [Full Example](#full-example))
|
||||
|
||||
#### Supported Channel Groups
|
||||
|
||||
| Channel Group ID | Description | Available on thing |
|
||||
|--------------------------------------------------------|---------------------|--------------------|
|
||||
| `device` | Device information. | FRITZ!DECT 440 |
|
||||
| `sensors` | Sensor data. | FRITZ!DECT 440 |
|
||||
| `top-left`, `bottom-left`, `top-right`, `bottom-right` | Button and trigger. | FRITZ!DECT 440 |
|
||||
|
||||
### DECT-ULE / HAN-FUN Devices
|
||||
|
||||
@@ -80,7 +93,7 @@ To do so
|
||||
- Enable the option "Login with FRITZ!Box user name and password".
|
||||
- Click "Apply" to save the settings.
|
||||
|
||||
Note: Now you can only log in to the FRITZ!Box with a user account, i.e. after entering a user name and password.
|
||||
**NOTE:** Now you can only log in to the FRITZ!Box with a user account, i.e. after entering a user name and password.
|
||||
|
||||
Auto-discovery is enabled by default.
|
||||
To disable it, you can add the following line to `<openHAB-conf>/services/runtime.cfg`:
|
||||
@@ -121,47 +134,48 @@ If the FRITZ!Powerline 546E is added via auto-discovery it determines its own `a
|
||||
|
||||
- `ain` (mandatory), no default (AIN number of the device)
|
||||
|
||||
### Finding The AIN ###
|
||||
### Finding The AIN
|
||||
|
||||
The AIN (actor identification number) can be found in the FRITZ!Box interface -> Home Network -> SmartHome. When opening the details view for a device with the edit button, the AIN is shown. Use the AIN without the blank.
|
||||
|
||||
## Supported Channels
|
||||
|
||||
| Channel Type ID | Item Type | Description | Available on thing |
|
||||
|-----------------|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------|
|
||||
| incoming_call | Call | Details about incoming call. | FRITZ!Box |
|
||||
| outgoing_call | Call | Details about outgoing call. | FRITZ!Box |
|
||||
| active_call | Call | Details about active call. | FRITZ!Box |
|
||||
| call_state | String | Details about current call state, either IDLE, RINGING, DIALING or ACTIVE. | FRITZ!Box |
|
||||
| apply_template | String | Apply template for device(s) (channel's state options contains available templates, for an alternative way see the description below) - FRITZ!OS 7 | FRITZ!Box, FRITZ!Powerline 546E |
|
||||
| mode | String | States the mode of the device (MANUAL/AUTOMATIC/VACATION) | FRITZ!DECT 210, FRITZ!DECT 200, FRITZ!Powerline 546E, FRITZ!DECT 301, FRITZ!DECT 300, Comet DECT |
|
||||
| locked | Contact | Device is locked for switching over external sources (OPEN/CLOSE) | FRITZ!DECT 210, FRITZ!DECT 200, FRITZ!Powerline 546E, FRITZ!DECT 301, FRITZ!DECT 300, Comet DECT |
|
||||
| device_locked | Contact | Device is locked for switching manually (OPEN/CLOSE) - FRITZ!OS 6.90 | FRITZ!DECT 210, FRITZ!DECT 200, FRITZ!Powerline 546E, FRITZ!DECT 301, FRITZ!DECT 300, Comet DECT |
|
||||
| temperature | Number:Temperature | Current measured temperature | FRITZ!DECT 210, FRITZ!DECT 200, FRITZ!DECT Repeater 100, FRITZ!DECT 301, FRITZ!DECT 300, Comet DECT |
|
||||
| energy | Number:Energy | Accumulated energy consumption | FRITZ!DECT 210, FRITZ!DECT 200, FRITZ!Powerline 546E |
|
||||
| power | Number:Power | Current power consumption | FRITZ!DECT 210, FRITZ!DECT 200, FRITZ!Powerline 546E |
|
||||
| voltage | Number:ElectricPotential | Current voltage - FRITZ!OS 7 | FRITZ!DECT 210, FRITZ!DECT 200, FRITZ!Powerline 546E |
|
||||
| outlet | Switch | Switchable outlet (ON/OFF) | FRITZ!DECT 210, FRITZ!DECT 200, FRITZ!Powerline 546E |
|
||||
| actual_temp | Number:Temperature | Current temperature of heating thermostat | FRITZ!DECT 301, FRITZ!DECT 300, Comet DECT |
|
||||
| set_temp | Number:Temperature | Set Temperature of heating thermostat | FRITZ!DECT 301, FRITZ!DECT 300, Comet DECT |
|
||||
| eco_temp | Number:Temperature | Eco Temperature of heating thermostat | FRITZ!DECT 301, FRITZ!DECT 300, Comet DECT |
|
||||
| comfort_temp | Number:Temperature | Comfort Temperature of heating thermostat | FRITZ!DECT 301, FRITZ!DECT 300, Comet DECT |
|
||||
| radiator_mode | String | Mode of heating thermostat (ON/OFF/COMFORT/ECO/BOOST/WINDOW_OPEN) | FRITZ!DECT 301, FRITZ!DECT 300, Comet DECT |
|
||||
| next_change | DateTime | Next change of the Set Temperature if scheduler is activated in the FRITZ!Box settings - FRITZ!OS 6.80 | FRITZ!DECT 301, FRITZ!DECT 300, Comet DECT |
|
||||
| next_temp | Number:Temperature | Next Set Temperature if scheduler is activated in the FRITZ!Box settings - FRITZ!OS 6.80 | FRITZ!DECT 301, FRITZ!DECT 300, Comet DECT |
|
||||
| battery_level | Number | Battery level (in %) - FRITZ!OS 7 | FRITZ!DECT 301, FRITZ!DECT 300, Comet DECT, FRITZ!DECT 400 |
|
||||
| battery_low | Switch | Battery level low (ON/OFF) - FRITZ!OS 6.80 | FRITZ!DECT 301, FRITZ!DECT 300, Comet DECT, FRITZ!DECT 400 |
|
||||
| contact_state | Contact | Contact state information (OPEN/CLOSED). | HAN-FUN contact (e.g. SmartHome Tür-/Fensterkontakt or SmartHome Bewegungsmelder)- FRITZ!OS 7 |
|
||||
| last_change | DateTime | States the last time the button was pressed. | FRITZ!DECT 400, HAN-FUN switch (e.g. SmartHome Wandtaster) - FRITZ!OS 7 |
|
||||
| Channel Type ID | Item Type | Description | Available on thing |
|
||||
|-----------------|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------|
|
||||
| incoming_call | Call | Details about incoming call. | FRITZ!Box |
|
||||
| outgoing_call | Call | Details about outgoing call. | FRITZ!Box |
|
||||
| active_call | Call | Details about active call. | FRITZ!Box |
|
||||
| call_state | String | Details about current call state, either IDLE, RINGING, DIALING or ACTIVE. | FRITZ!Box |
|
||||
| apply_template | String | Apply template for device(s) (channel's state options contains available templates, for an alternative way see the description below) - FRITZ!OS 7 | FRITZ!Box, FRITZ!Powerline 546E |
|
||||
| mode | String | States the mode of the device (MANUAL/AUTOMATIC/VACATION) | FRITZ!DECT 210, FRITZ!DECT 200, FRITZ!Powerline 546E, FRITZ!DECT 301, FRITZ!DECT 300, Comet DECT |
|
||||
| locked | Contact | Device is locked for switching over external sources (OPEN/CLOSE) | FRITZ!DECT 210, FRITZ!DECT 200, FRITZ!Powerline 546E, FRITZ!DECT 301, FRITZ!DECT 300, Comet DECT |
|
||||
| device_locked | Contact | Device is locked for switching manually (OPEN/CLOSE) - FRITZ!OS 6.90 | FRITZ!DECT 210, FRITZ!DECT 200, FRITZ!Powerline 546E, FRITZ!DECT 301, FRITZ!DECT 300, Comet DECT |
|
||||
| temperature | Number:Temperature | Current measured temperature | FRITZ!DECT 210, FRITZ!DECT 200, FRITZ!DECT Repeater 100, FRITZ!DECT 301, FRITZ!DECT 300, Comet DECT, FRITZ!DECT 440 |
|
||||
| energy | Number:Energy | Accumulated energy consumption | FRITZ!DECT 210, FRITZ!DECT 200, FRITZ!Powerline 546E |
|
||||
| power | Number:Power | Current power consumption | FRITZ!DECT 210, FRITZ!DECT 200, FRITZ!Powerline 546E |
|
||||
| voltage | Number:ElectricPotential | Current voltage - FRITZ!OS 7 | FRITZ!DECT 210, FRITZ!DECT 200, FRITZ!Powerline 546E |
|
||||
| outlet | Switch | Switchable outlet (ON/OFF) | FRITZ!DECT 210, FRITZ!DECT 200, FRITZ!Powerline 546E |
|
||||
| actual_temp | Number:Temperature | Current temperature of heating thermostat | FRITZ!DECT 301, FRITZ!DECT 300, Comet DECT |
|
||||
| set_temp | Number:Temperature | Set Temperature of heating thermostat | FRITZ!DECT 301, FRITZ!DECT 300, Comet DECT |
|
||||
| eco_temp | Number:Temperature | Eco Temperature of heating thermostat | FRITZ!DECT 301, FRITZ!DECT 300, Comet DECT |
|
||||
| comfort_temp | Number:Temperature | Comfort Temperature of heating thermostat | FRITZ!DECT 301, FRITZ!DECT 300, Comet DECT |
|
||||
| radiator_mode | String | Mode of heating thermostat (ON/OFF/COMFORT/ECO/BOOST/WINDOW_OPEN) | FRITZ!DECT 301, FRITZ!DECT 300, Comet DECT |
|
||||
| next_change | DateTime | Next change of the Set Temperature if scheduler is activated in the FRITZ!Box settings - FRITZ!OS 6.80 | FRITZ!DECT 301, FRITZ!DECT 300, Comet DECT |
|
||||
| next_temp | Number:Temperature | Next Set Temperature if scheduler is activated in the FRITZ!Box settings - FRITZ!OS 6.80 | FRITZ!DECT 301, FRITZ!DECT 300, Comet DECT |
|
||||
| battery_level | Number | Battery level (in %) - FRITZ!OS 7 | FRITZ!DECT 301, FRITZ!DECT 300, Comet DECT, FRITZ!DECT 400, FRITZ!DECT 440 |
|
||||
| battery_low | Switch | Battery level low (ON/OFF) - FRITZ!OS 6.80 | FRITZ!DECT 301, FRITZ!DECT 300, Comet DECT, FRITZ!DECT 400, FRITZ!DECT 440 |
|
||||
| contact_state | Contact | Contact state information (OPEN/CLOSED). | HAN-FUN contact (e.g. SmartHome Tür-/Fensterkontakt or SmartHome Bewegungsmelder)- FRITZ!OS 7 |
|
||||
| last_change | DateTime | States the last time the button was pressed. | FRITZ!DECT 400, FRITZ!DECT 440, HAN-FUN switch (e.g. SmartHome Wandtaster) - FRITZ!OS 7 |
|
||||
|
||||
### Triggers
|
||||
|
||||
| Channel Type ID | Item Type | Description | Available on thing |
|
||||
|-----------------|-----------|--------------------------------------------------------------------------------|---------------------------------------------------------|
|
||||
| press | Trigger | Dispatches a `PRESSED` event when a button is pressed. | HAN-FUN switch (e.g. SmartHome Wandtaster) - FRITZ!OS 7 |
|
||||
| press | Trigger | Dispatches a `SHORT_PRESSED` or `LONG_PRESSED` event when a button is pressed. | FRITZ!DECT 400 - FRITZ!OS 7.08 |
|
||||
| Channel Type ID | Item Type | Description | Available on thing |
|
||||
|-----------------|-----------|--------------------------------------------------------------------------------|-----------------------------------------------------------|
|
||||
| press | Trigger | Dispatches a `PRESSED` event when a button is pressed. | FRITZ!DECT440, HAN-FUN switch (e.g. SmartHome Wandtaster) |
|
||||
| press | Trigger | Dispatches a `SHORT_PRESSED` or `LONG_PRESSED` event when a button is pressed. | FRITZ!DECT 400 |
|
||||
|
||||
The trigger channel `press` is of type `system.rawbutton` to allow the usage of the `rawbutton-toggle-switch` profile.
|
||||
The trigger channel `press` for a FRITZ!DECT 440 device or HAN-FUN switch is of type `system.rawbutton` to allow the usage of the `rawbutton-toggle-switch` profile.
|
||||
The trigger channel `press` for a FRITZ!DECT 400 device is of type `system.button`.
|
||||
|
||||
### FRITZ! Smart Home Templates
|
||||
|
||||
@@ -210,6 +224,7 @@ demo.things:
|
||||
|
||||
```java
|
||||
Bridge avmfritz:fritzbox:1 "FRITZ!Box" [ ipAddress="192.168.x.x", password="xxx", user="xxx" ] {
|
||||
Thing FRITZ_DECT_440 vvvvvvvvvvvv "FRITZ!DECT 440 #15" [ ain="vvvvvvvvvvvv" ]
|
||||
Thing FRITZ_DECT_200 xxxxxxxxxxxx "FRITZ!DECT 200 #1" [ ain="xxxxxxxxxxxx" ]
|
||||
Thing FRITZ_Powerline_546E yy_yy_yy_yy_yy_yy "FRITZ!Powerline 546E #2" [ ain="yy:yy:yy:yy:yy:yy" ]
|
||||
Thing Comet_DECT aaaaaabbbbbb "Comet DECT #3" [ ain="aaaaaabbbbbb" ]
|
||||
@@ -230,6 +245,14 @@ Call OutgoingCall "Outgoing call: [%1$s to %2$s]" { channel="avmfritz:fritzbo
|
||||
Call ActiveCall "Call established [%1$s]" { channel="avmfritz:fritzbox:1:active_call" }
|
||||
String ApplyTemplate "Apply template" { channel="avmfritz:fritzbox:1:apply_template" }
|
||||
|
||||
Number:Temperature SwitchTemperature "Current measured temperature [%.1f %unit%]" { channel="avmfritz:FRITZ_DECT_440:1:vvvvvvvvvvvv:sensors#temperature" }
|
||||
Number SwitchBatteryLevel "Battery level" { channel="avmfritz:FRITZ_DECT_440:1:vvvvvvvvvvvv:device#battery_level" }
|
||||
Switch SwitchBatteryLow "Battery low" { channel="avmfritz:FRITZ_DECT_440:1:vvvvvvvvvvvv:device#battery_low" }
|
||||
DateTime TopLeftSwitchLastChanged "Last change" { channel="avmfritz:FRITZ_DECT_440:1:vvvvvvvvvvvv:top-left#last_change" }
|
||||
DateTime BottomLeftSwitchLastChanged "Last change" { channel="avmfritz:FRITZ_DECT_440:1:vvvvvvvvvvvv:bottom-left#last_change" }
|
||||
DateTime TopRightSwitchLastChanged "Last change" { channel="avmfritz:FRITZ_DECT_440:1:vvvvvvvvvvvv:top-right#last_change" }
|
||||
DateTime BottomRightSwitchLastChanged "Last change" { channel="avmfritz:FRITZ_DECT_440:1:vvvvvvvvvvvv:bottom-right#last_change" }
|
||||
|
||||
Switch Outlet1 "Switchable outlet" { channel="avmfritz:FRITZ_DECT_200:1:xxxxxxxxxxxx:outlet" }
|
||||
Number:Temperature Temperature1 "Current measured temperature [%.1f %unit%]" { channel="avmfritz:FRITZ_DECT_200:1:xxxxxxxxxxxx:temperature" }
|
||||
Number:Energy Energy1 "Accumulated energy consumption [%.3f kWh]" { channel="avmfritz:FRITZ_DECT_200:1:xxxxxxxxxxxx:energy" }
|
||||
@@ -300,6 +323,15 @@ sitemap demo label="Main Menu" {
|
||||
|
||||
demo.rules:
|
||||
|
||||
```java
|
||||
rule "FRITZ!DECT 440 Top Left Button pressed"
|
||||
when
|
||||
Channel "avmfritz:FRITZ_DECT_440:1:vvvvvvvvvvvv:top-left#press" triggered PRESSED
|
||||
then
|
||||
logInfo("demo", "Top Left Button pressed")
|
||||
end
|
||||
```
|
||||
|
||||
```java
|
||||
rule "HAN-FUN Button pressed"
|
||||
when
|
||||
|
||||
Reference in New Issue
Block a user