# EchonetLite Binding
|
||||
|
||||
This binding supports devices that make use of the Echonet Lite specification (https://echonet.jp/spec_v113_lite_en/).
|
||||
|
||||
## Supported Things
|
||||
|
||||
* Mitsubishi Electric MAC-568IF-E Wi-Fi interface (common on most Mitsubishi Heat Pumps).
|
||||
|
||||
## Discovery
|
||||
|
||||
Discovery is supported using UDP Multicast.
|
||||
When running over Wi-Fi it is advisable to run openHAB on the same network as the Echonet Lite devices.
|
||||
Multicast traffic doesn't easily route over multiple networks and will often be dropped.
|
||||
Discovery is handled via the Echonet Lite bridge, which contains the configuration of the multicast address used for discovery and asynchronous device notifications along with the port.
|
||||
It is unlikely that this configuration will require changing.
|
||||
|
||||
## Bridge Configuration
|
||||
|
||||
The bridge configuration defaults should be applicable in most scenarios.
|
||||
If device discovery is not working, this is most likely caused by the inability to receive multicast traffic from the device nodes.
|
||||
|
||||
* __port__: Port used for messaging both to and from device nodes, defaults to 3610.
|
||||
* __multicastAddress__: Multicast address used to discover device nodes and to receive asynchronous notifications from devices.
|
||||
|
||||
## Thing Configuration
|
||||
|
||||
* __hostname__: Hostname or IP address of the device node.
|
||||
* __port__: Port used to communicate with the device.
|
||||
* __groupCode__: Group code as specified in "APPENDIX Detailed Requirements for ECHONET Device objects" (https://echonet.jp/spec_object_rp1_en/).
|
||||
For Air Conditioners the value is '1'.
|
||||
* __classCode__: Class code for the device, see __groupCode__ for reference information.
|
||||
The value for Home Air Conditioners is '48' (0x30).
|
||||
* __instance__: Instance identifier if multiple instances are running on the same IP address.
|
||||
Typically, this value will be '1'.
|
||||
* __pollIntervalMs__: Interval between polls of the device for its current status.
|
||||
If multicast is not working this will determine the latency at which changes made directly on the device will be propagated back to openHAB, default is 30 000ms.
|
||||
* __retryTimeoutMs__: Length of time the bridge will wait before resubmitting a request, default is 2 000ms.
|
||||
|
||||
Because the binding uses UDP, packets can be lost on the network, so retries are necessary.
|
||||
Testing has shown that 2 000ms is a reasonable default that allows for timely retries without rejecting slow, but legitimate responses.
|
||||
|
||||
## Channels
|
||||
|
||||
Channels are derived from the Echonet Lite specification and vary from device to device depending on capabilities.
|
||||
The full set of potential channels is available from "APPENDIX Detailed Requirements for ECHONET Device objects" (https://echonet.jp/spec_object_rp1_en/)
|
||||
|
||||
The channels currently implemented are:
|
||||
|
||||
| Channel | Data Type | Description |
|
||||
|------------------------------------|-----------|-------------------------------------------------------------------------|
|
||||
| operationStatus | Switch | Switch On/Off the device |
|
||||
| installationLocation | String | Installation location (option) |
|
||||
| standardVersionInformation | String | Standard Version Information |
|
||||
| identificationNumber | String | Unique id for device (used by auto discovery for the thingId) |
|
||||
| manufacturerFaultCode | String | Manufacturer Fault Code |
|
||||
| faultStatus | Switch | Fault Status |
|
||||
| faultDescription | String | Fault Description |
|
||||
| manufacturerCode | String | Manufacturer Code |
|
||||
| businessFacilityCode | String | Business Facility Code |
|
||||
| powerSavingOperationSetting | Switch | Controls whether the unit is in power saving operation or not |
|
||||
| cumulativeOperatingTime | Number | Cumulative Operating Time |
|
||||
| airFlowRate | String | Air Flow Rate |
|
||||
| automaticControlOfAirFlowDirection | String | The type of automatic control applied to the air flow direction, if any |
|
||||
| automaticSwingOfAirFlow | String | Automatic Swing Of Air Flow |
|
||||
| airFlowDirectionVertical | String | Air Flow Direction Vertical |
|
||||
| airFlowDirectionHorizontal | String | Air Flow Direction Horizontal |
|
||||
| operationMode | String | The current mode for the Home AC unit (heating, cooling, etc.) |
|
||||
| setTemperature | Number | Desired target room temperature |
|
||||
| measuredRoomTemperature | Number | Measured Room Temperature |
|
||||
| measuredOutdoorTemperature | Number | Measured Outdoor Temperature |
|
||||
|
||||
## Full Example
|
||||
|
||||
|
||||
### Things
|
||||
|
||||
```
|
||||
Bridge echonetlite:bridge:1 [port="3610", multicastAddress="224.0.23.0"] {
|
||||
Thing device HeatPump_Bedroom1 "HeatPump Bedroom 1" @ "Bedroom 1" [hostname="192.168.0.55", port="3610", groupCode="1", classCode="48", instance="1", pollIntervalMs="30000", retryTimeoutMs="2000"]
|
||||
}
|
||||
```
|
||||
|
||||
### Items
|
||||
|
||||
```
|
||||
Switch HeatPumpBedroom1_OperationStatus "HeatPump Bedroom1 Operation Status" {channel="echonetlite:device:1:HeatPump_Bedroom1:operationStatus"}
|
||||
```
|
||||