[Documentation] Markdown improvements for bindings a to e (#13859)
Signed-off-by: Jerome Luckenbach <github@luckenba.ch>
This commit is contained in:
committed by
GitHub
parent
72efc1cfed
commit
caf71f72e6
@@ -15,13 +15,13 @@ This procedure opens TCP/IP port 1012 on your FRITZ!Box.
|
||||
(It can be deactivated again by dialing `#96*4*`.)
|
||||
You can test if everything is working with the Telnet program from your openHAB server:
|
||||
|
||||
```
|
||||
```shell
|
||||
telnet fritz.box 1012
|
||||
```
|
||||
|
||||
If you see an output like this:
|
||||
|
||||
```
|
||||
```shell
|
||||
Trying 192.168.178.1...
|
||||
Connected to fritz.box.
|
||||
Escape character is '^]'.
|
||||
@@ -65,7 +65,7 @@ The FRITZ!Box has to run at least on firmware FRITZ!OS 6.35.
|
||||
The [FRITZ!DECT 400](https://avm.de/produkte/fritzdect/fritzdect-400/) and [FRITZ!DECT 440](https://avm.de/produkte/fritzdect/fritzdect-440/) are buttons for convenient operation of FRITZ! Smart Home devices (FRITZ!OS 7.08 or higher for FRITZ!DECT 400, 7.20 or higher for FRITZ!DECT 440).
|
||||
The FRITZ!DECT 400 supports a configurable button to trigger short or long press events.
|
||||
Beside four customizable buttons the FRITZ!DECT 440 supports temperature readings.
|
||||
** NOTE: ** FRITZ!DECT 440 now uses Channel Groups to group its Channels like `device#battery_level`, `device#battery_low` for device information, `sensors#temperature` for sensor data and `top-left`, `bottom-left`, `top-right` and `bottom-right` combined with `press` and `last_change` (see [Full Example](#full-example))
|
||||
**NOTE:** FRITZ!DECT 440 now uses Channel Groups to group its Channels like `device#battery_level`, `device#battery_low` for device information, `sensors#temperature` for sensor data and `top-left`, `bottom-left`, `top-right` and `bottom-right` combined with `press` and `last_change` (see [Full Example](#full-example))
|
||||
|
||||
### FRITZ!DECT 500
|
||||
|
||||
@@ -99,7 +99,7 @@ The use of other Sensors should be possible, if these are compatible with DECT-U
|
||||
|
||||
The FRITZ!Box has to run at least on firmware FRITZ!OS 7.
|
||||
|
||||
### FRITZ! Groups
|
||||
### FRITZ! Groups
|
||||
|
||||
The FRITZ!OS supports two different types of groups.
|
||||
On the one hand there are groups for heating thermostats on the other hand there are groups for switchable outlets and power meters.
|
||||
@@ -126,7 +126,7 @@ To do so
|
||||
Auto-discovery is enabled by default.
|
||||
To disable it, you can add the following line to `<openHAB-conf>/services/runtime.cfg`:
|
||||
|
||||
```
|
||||
```text
|
||||
discovery.avmfritz:background=false
|
||||
```
|
||||
|
||||
@@ -217,13 +217,13 @@ The trigger channel `press` for a FRITZ!DECT 400 device is of type `system.butto
|
||||
With the new [templates feature](https://en.avm.de/guide/smart-home/meet-the-smart-home-templates-from-fritz/) in FRITZ!OS 7, you can now save the settings of your Smart Home devices and groups as a template for certain occasions e.g. holidays or vacation.
|
||||
Unfortunately it is not that simple to find out the unique identifier (AIN) for a template needed for sending it as command to the `apply_template` channel.
|
||||
Here is a work-around:
|
||||
To retrieve the list of AINs assigned by FRITZ! for your templates, go to the FRITZ!Box' Support page at http://fritz.box/html/support.html within your local network and login.
|
||||
To retrieve the list of AINs assigned by FRITZ! for your templates, go to the FRITZ!Box' Support page at [http://fritz.box/html/support.html](http://fritz.box/html/support.html) within your local network and login.
|
||||
Then in the section "Support Data" ("Support-Daten") press the button "Create Support Data" ("Support-Daten erstellen") and save the generated text file.
|
||||
Open the file in a text editor and search for the term "avm_home_device_type_template".
|
||||
You will find entries like the attached one.
|
||||
The `identifyer 'tmpFC0F2C-3960B7EE6'` contains the templates AINs you need for using them in rules.
|
||||
|
||||
```
|
||||
```text
|
||||
Name 'Demo Template', identifyer 'tmpFC0F2C-3960B7EE6', firmware version '0.1'
|
||||
[aktive] ID 60013, emc 0x0, model 0x0, grouphash=0x0, devicetype 'avm_home_device_type_template', functionbitmask 0x4000, sortid 0, batt perc 255 low 255, pollinterval 0, polltimeout 0, validchangetime: 0
|
||||
--------------------
|
||||
@@ -245,8 +245,7 @@ end
|
||||
For heating devices and heating groups there are two actions available to set Boost or Window Open mode for a given duration: `setBoostMode(long)` and `setWindowOpenMode(long)`.
|
||||
The duration has to be given in seconds, min. 1, max. 86400, 0 for deactivation.
|
||||
|
||||
|
||||
```
|
||||
```java
|
||||
val actions = getActions("avmfritz","avmfritz:Comet_DECT:1:aaaaaabbbbbb")
|
||||
|
||||
// set Boost mode for 5 min
|
||||
|
||||
Reference in New Issue