[openwebnet] Fix messages flooding BUS on reboot (#10934)
* [openwebnet] changed ALL_DEVICES_REFRESH_INTERVAL to 60s to avoid lights/shutters status updates flooding Signed-off-by: Massimo Valla <mvcode00@gmail.com> * [openwebnet] added UPnP discovery for MyHOME_Screen3,5. Updated catalogue links in README Signed-off-by: Massimo Valla <mvcode00@gmail.com>
This commit is contained in:
parent
e967dc28bc
commit
cdb8d46fa8
|
@ -20,14 +20,15 @@ In order for this binding to work, a **BTicino/Legrand OpenWebNet gateway** is n
|
|||
These gateways have been tested with the binding:
|
||||
|
||||
- **IP gateways** or scenario programmers, such as BTicino
|
||||
[F454](https://www.homesystems-legrandgroup.com/BtHomeSystems/productDetail.action?lang=EN&productId=006),
|
||||
[MyHOMEServer1](https://www.homesystems-legrandgroup.com/BtHomeSystems/productDetail.action?lang=EN&productId=067),
|
||||
[MyHOME_Screen10](https://www.homesystems-legrandgroup.com/BtHomeSystems/productDetail.action?lang=EN&productId=001),
|
||||
[MH201](https://www.homesystems-legrandgroup.com/BtHomeSystems/productDetail.action?lang=EN&productId=053),
|
||||
[MH202](https://www.homesystems-legrandgroup.com/BtHomeSystems/productDetail.action?lang=EN&productId=059),
|
||||
[F455](https://www.homesystems-legrandgroup.com/BtHomeSystems/productDetail.action?lang=EN&productId=051),
|
||||
[MH200N](https://www.homesystems-legrandgroup.com/BtHomeSystems/productDetail.action?lang=EN&productId=016),
|
||||
[F453](https://www.homesystems-legrandgroup.com/BtHomeSystems/productDetail.action?lang=EN&productId=027), etc.
|
||||
[F454](https://catalogue.bticino.com/BTI-F454-EN),
|
||||
[MyHOMEServer1](https://catalogue.bticino.com/BTI-MYHOMESERVER1-EN),
|
||||
[MyHOME_Screen10 (MH4893C)](https://catalogue.bticino.com/BTI-MH4893C-EN),
|
||||
[MyHOME_Screen3,5 (LN4890)](https://catalogue.bticino.com/BTI-LN4890-EN),
|
||||
[MH201](https://catalogue.bticino.com/BTI-MH201-EN),
|
||||
[MH202](https://catalogue.bticino.com/BTI-MH202-EN),
|
||||
[F455](https://www.homesystems-legrandgroup.com/home?p_p_id=it_smc_bticino_homesystems_search_AutocompletesearchPortlet&p_p_lifecycle=0&p_p_state=normal&p_p_mode=view&_it_smc_bticino_homesystems_search_AutocompletesearchPortlet_journalArticleId=2481871&_it_smc_bticino_homesystems_search_AutocompletesearchPortlet_mvcPath=%2Fview_journal_article_content.jsp),
|
||||
[MH200N](https://www.homesystems-legrandgroup.com/home?p_p_id=it_smc_bticino_homesystems_search_AutocompletesearchPortlet&p_p_lifecycle=0&p_p_state=normal&p_p_mode=view&_it_smc_bticino_homesystems_search_AutocompletesearchPortlet_journalArticleId=2469209&_it_smc_bticino_homesystems_search_AutocompletesearchPortlet_mvcPath=%2Fview_journal_article_content.jsp),
|
||||
[F453](https://www.homesystems-legrandgroup.com/home?p_p_id=it_smc_bticino_homesystems_search_AutocompletesearchPortlet&p_p_lifecycle=0&p_p_state=normal&p_p_mode=view&_it_smc_bticino_homesystems_search_AutocompletesearchPortlet_journalArticleId=2703566&_it_smc_bticino_homesystems_search_AutocompletesearchPortlet_mvcPath=%2Fview_journal_article_content.jsp), etc.
|
||||
|
||||
- **ZigBee USB Gateways**, such as [BTicino 3578](https://catalogo.bticino.it/BTI-3578-IT), also known as Legrand 088328
|
||||
|
||||
|
@ -39,10 +40,10 @@ The following Things and OpenWebNet `WHOs` are supported:
|
|||
|
||||
| Category | WHO | Thing Type IDs | Description | Status |
|
||||
| -------------------- | :----------: | :---------------------------------: | ---------------------------------------------------------------- | ---------------- |
|
||||
| Gateway Management | `13` | `bus_gateway` | Any IP gateway supporting OpenWebNet protocol should work (e.g. F454 / MyHOMEServer1 / MH202 / F455 / MH200N, ...) | Successfully tested: F454, MyHOMEServer1, MyHOME_Screen10, F455, F452, F453AV, MH201, MH202, MH200N. Some connection stability issues/gateway resets reported with MH202 |
|
||||
| Gateway Management | `13` | `bus_gateway` | Any IP gateway supporting OpenWebNet protocol should work (e.g. F454 / MyHOMEServer1 / MH202 / F455 / MH200N, ...) | Successfully tested: F454, MyHOMEServer1, MyHOME_Screen10, MyHOME_Screen3,5, F455, F452, F453AV, MH201, MH202, MH200N. Some connection stability issues/gateway resets reported with MH202 |
|
||||
| Lighting | `1` | `bus_on_off_switch`, `bus_dimmer` | BUS switches and dimmers | Successfully tested: F411/2, F411/4, F411U2, F422, F429. Some discovery issues reported with F429 (DALI Dimmers) |
|
||||
| Automation | `2` | `bus_automation` | BUS roller shutters, with position feedback and auto-calibration | Successfully tested: LN4672M2 |
|
||||
| Temperature Control | `4` | `bus_thermo_zone`, `bus_thermo_sensor` | Thermo zones management and temperature sensors (probes). NOTE Central Units (4 or 99 zones) are not fully supported yet. See [Channels - Thermo](#configuring-thermo) for more details. | Successfully tested: H/LN4691, KG4691; thermo sensors: L/N/NT4577 + 3455 |
|
||||
| Temperature Control | `4` | `bus_thermo_zone`, `bus_thermo_sensor` | Thermo zones management and temperature sensors (probes). NOTE Central Units (4 or 99 zones) are not fully supported yet. See [Channels - Thermo](#configuring-thermo) for more details. | Successfully tested: H/LN4691, HS4692, KG4691; thermo sensors: L/N/NT4577 + 3455 |
|
||||
| Energy Management | `18` | `bus_energy_meter` | Energy Management | Successfully tested: F520, F521 |
|
||||
|
||||
### For ZigBee (Radio)
|
||||
|
@ -131,7 +132,7 @@ In BTicino MyHOME Thermoregulation (WHO=4) each **zone** has associated a thermo
|
|||
Thermo zones can be configured defining a `bus_thermo_zone` Thing for each zone with the following parameters:
|
||||
|
||||
- the `where` config parameter (`OpenWebNet Device Address`):
|
||||
- example BUS/SCS Thermo `zone=1` --> `where="1"`
|
||||
- example BUS/SCS Thermo zone `1` --> `where="1"`
|
||||
- the `standAlone` config parameter (`boolean`, default: `true`): identifies if the zone is managed or not by a Central Unit (4 or 99 zones). `standAlone=true` means no Central Unit is present in the system.
|
||||
|
||||
Temperature sensors can be configured defining a `bus_thermo_sensor` Thing with the following parameters:
|
||||
|
|
|
@ -60,8 +60,8 @@ public class OpenWebNetAutomationHandler extends OpenWebNetThingHandler {
|
|||
private static final SimpleDateFormat DATE_FORMATTER = new SimpleDateFormat("ss.SSS");
|
||||
|
||||
private static long lastAllDevicesRefreshTS = -1; // timestamp when the last request for all device refresh was sent
|
||||
protected static final int ALL_DEVICES_REFRESH_INTERVAL_MSEC = 2000; // interval in msec before sending another all
|
||||
// devices refresh request
|
||||
protected static final int ALL_DEVICES_REFRESH_INTERVAL_MSEC = 60000; // interval in msec before sending another all
|
||||
// devices refresh request
|
||||
|
||||
public static final Set<ThingTypeUID> SUPPORTED_THING_TYPES = OpenWebNetBindingConstants.AUTOMATION_SUPPORTED_THING_TYPES;
|
||||
|
||||
|
|
|
@ -72,8 +72,8 @@ public class OpenWebNetLightingHandler extends OpenWebNetThingHandler {
|
|||
private static long lastAllDevicesRefreshTS = -1; // timestamp when the last request for all device refresh was sent
|
||||
// for this handler
|
||||
|
||||
protected static final int ALL_DEVICES_REFRESH_INTERVAL_MSEC = 2000; // interval in msec before sending another all
|
||||
// devices refresh request
|
||||
protected static final int ALL_DEVICES_REFRESH_INTERVAL_MSEC = 60000; // interval in msec before sending another all
|
||||
// devices refresh request
|
||||
|
||||
private long lastBrightnessChangeSentTS = 0; // timestamp when last brightness change was sent to the device
|
||||
|
||||
|
|
|
@ -54,18 +54,19 @@ public class BusGatewayUpnpDiscovery implements UpnpDiscoveryParticipant {
|
|||
MH202("scheduler", "MH202"),
|
||||
F454("webserver", "F454"),
|
||||
MY_HOME_SERVER1("myhomeserver1", "MYHOMESERVER1"),
|
||||
TOUCH_SCREEN_3_5("touchscreen", "TOUCHSCREEN3_5"),
|
||||
TOUCH_SCREEN_10("ts10", "TOUCHSCREEN10"),
|
||||
MH200N("lightingcontrolunit", "MH200N");
|
||||
|
||||
private final String value, thingId;
|
||||
private final String discoveryString, thingId;
|
||||
|
||||
private BusGatewayId(String value, String thingId) {
|
||||
this.value = value;
|
||||
this.discoveryString = value;
|
||||
this.thingId = thingId;
|
||||
}
|
||||
|
||||
public static @Nullable BusGatewayId fromValue(String s) {
|
||||
Optional<BusGatewayId> m = Arrays.stream(values()).filter(val -> s.equals(val.value)).findFirst();
|
||||
Optional<BusGatewayId> m = Arrays.stream(values()).filter(val -> s.equals(val.discoveryString)).findFirst();
|
||||
if (m.isPresent()) {
|
||||
return m.get();
|
||||
} else {
|
||||
|
|