[Documentation] Markdown improvements t to z (#14371)
* Apply markdown fixes for bindings with letter _t_ * Apply markdown fixes for bindings with letter _u_ * Apply markdown fixes for bindings with letter _v_ * Apply markdown fixes for bindings with letter _w_ * Apply markdown fixes for bindings with letter _x_ * Apply markdown fixes for bindings with letter _y_ * Apply markdown fixes for bindings with letter _z_ Signed-off-by: Jerome Luckenbach <github@luckenba.ch>
This commit is contained in:
committed by
GitHub
parent
69a09ed825
commit
ce3f673380
@@ -5,9 +5,9 @@ The software comes with a full stack from Z-Wave transceiver with certified firm
|
||||
|
||||
[Z-Way](https://www.z-wave.me/z-way) comes in three parts:
|
||||
|
||||
- a firmware that runs on the Z-Wave transceiver chip
|
||||
- the communication stack that runs on different host Operating Systems
|
||||
- an automation engine and optionally a web server to implement a User Interface
|
||||
- a firmware that runs on the Z-Wave transceiver chip
|
||||
- the communication stack that runs on different host Operating Systems
|
||||
- an automation engine and optionally a web server to implement a User Interface
|
||||
|
||||
All parts together represents a smart home controller for Z-Wave.
|
||||
|
||||
@@ -17,7 +17,7 @@ A detailed step-by-step description of the binding configuration is also availab
|
||||
|
||||
Please note the **known issues** below.
|
||||
|
||||
### Approach
|
||||
## Approach
|
||||
|
||||
The idea behind is the integration of Z-Wave through a bridge (Z-Way controller).
|
||||
The existing, certified Z-Way stack can be used to build, configure and control the Z-Wave network.
|
||||
@@ -35,19 +35,19 @@ In Z-Way there are devices which represent physical devices and (virtual) device
|
||||
The difference is that physical devices usually have several functions.
|
||||
Z-Way server constructs (virtual) devices for each function, such as motion sensors or door contacts.
|
||||
In openHAB, these functions are bundled into physical devices and represented as things with channels for each function.
|
||||
This type of thing is a *Z-Wave Device*.
|
||||
On the other hand all virtual devices are mapped to *Z-Way Virtual Devices* with exactly one channel.
|
||||
This type of thing is a _Z-Wave Device_.
|
||||
On the other hand all virtual devices are mapped to _Z-Way Virtual Devices_ with exactly one channel.
|
||||
|
||||
- *Z-Way Server* (Bridge) represents a bridge with general settings and communication tasks.
|
||||
- *Z-Way Virtual Device* represents one (virtual) device with the corresponding channel. A bridge is necessary as an intermediary between openHAB thing and Z-Way device.
|
||||
- *Z-Wave Device* represents a device of real world. Each device function will be mapped to a separate channel. The bridge is necessary as an intermediary between openHAB thing and Z-Way device.
|
||||
- _Z-Way Server_ (Bridge) represents a bridge with general settings and communication tasks.
|
||||
- _Z-Way Virtual Device_ represents one (virtual) device with the corresponding channel. A bridge is necessary as an intermediary between openHAB thing and Z-Way device.
|
||||
- _Z-Wave Device_ represents a device of real world. Each device function will be mapped to a separate channel. The bridge is necessary as an intermediary between openHAB thing and Z-Way device.
|
||||
|
||||
## Discovery
|
||||
|
||||
A discovery service for Z-Way servers scans local network and must always be started manually.
|
||||
Z-Way doesn't support any discovery protocol like UPnP for this purpose.
|
||||
That is why first all IP addresses in local network are checked on port 8083.
|
||||
If the server answers, a ZAutomation request (*/ZAutomation/api/v1/status*) is performed to ensure, the found server runs Z-Way.
|
||||
If the server answers, a ZAutomation request (_/ZAutomation/api/v1/status_) is performed to ensure, the found server runs Z-Way.
|
||||
|
||||
Another discovery service provides available devices (a configured bridge is necessary).
|
||||
The device discovery service is performed at a specified interval, but can also be started manually.
|
||||
@@ -78,7 +78,7 @@ Besides the username and password all required Z-Way information are found durin
|
||||
|
||||
Only the Z-Way server can be configured textual:
|
||||
|
||||
```
|
||||
```java
|
||||
Bridge zway:zwayServer:192_168_2_42 [ zwayServerIpAddress="localhost", zwayServerPort=8083, zwayServerProtocol="http", zwayServerUsername="admin", zwayServerPassword="admin", pollingInterval=3600 ] {
|
||||
// associated things have to be created with the UI
|
||||
}
|
||||
@@ -91,7 +91,6 @@ Bridge zway:zwayServer:192_168_2_42 [ zwayServerIpAddress="localhost", zwayServe
|
||||
| deviceId | X | | Device ID of virtual device |
|
||||
| bridge reference | X | | |
|
||||
|
||||
|
||||
### Z-Wave Device
|
||||
|
||||
| Configuration Name | Mandatory | Default | Description |
|
||||
@@ -112,7 +111,7 @@ The following channels are currently supported.
|
||||
| sensorHumidity | Number | Humidity | SensorMultilevel - humidity |
|
||||
| sensorBarometer | Number | Pressure | SensorMultilevel - barometer |
|
||||
| sensorUltraviolet | Number | Light | SensorMultilevel - ultraviolet |
|
||||
| sensorCO2 | Number | CarbonDioxide | SensorMultilevel - *Special case:* no probe type for carbon dioxide sensors available - probe title *CO2 Level* acts as selection criterion |
|
||||
| sensorCO2 | Number | CarbonDioxide | SensorMultilevel - _Special case:_ no probe type for carbon dioxide sensors available - probe title _CO2 Level_ acts as selection criterion |
|
||||
| sensorEnergy | Number | Energy | SensorMultilevel - energy |
|
||||
| sensorMeterKWh | Number | Energy | SensorMultilevel - meterElectric_kilowatt_per_hour |
|
||||
| sensorMeterW | Number | Energy | SensorMultilevel - meterElectric_watt |
|
||||
@@ -122,14 +121,14 @@ The following channels are currently supported.
|
||||
| sensorTamper | Switch | Alarm | SensorBinary - tamper |
|
||||
| sensorDoorWindow | Contact | Contact | SensorBinary - door-window |
|
||||
| sensorMotion | Switch | Motion | SensorBinary - general_purpose, motion |
|
||||
| switchPowerOutlet | Switch | PowerOutlet | SwitchBinary - *Special case:* no probe type for power outlet available - icon *switch* acts as selection criterion |
|
||||
| switchPowerOutlet | Switch | PowerOutlet | SwitchBinary - _Special case:_ no probe type for power outlet available - icon _switch_ acts as selection criterion |
|
||||
| switchColorTemperature | Dimmer | ColorLight | SwitchMultilevel - switchColor_soft_white, switchColor_cold_white |
|
||||
| thermostatMode | Switch | Temperature | SwitchBinary - thermostat_mode |
|
||||
|
||||
Currently unsupported Z-Way probe types:
|
||||
|
||||
- SensorBinary: cooling, all alarm types (resulting from Z-Wave command class AlarmSensor(deprecated) and Alarm)
|
||||
- SensorMultilevel: meterElectric_pulse_count, meterElectric_voltage, meterElectric_ampere, meterElectric_power_factor
|
||||
- SensorBinary: cooling, all alarm types (resulting from Z-Wave command class AlarmSensor(deprecated) and Alarm)
|
||||
- SensorMultilevel: meterElectric_pulse_count, meterElectric_voltage, meterElectric_ampere, meterElectric_power_factor
|
||||
|
||||
### Universial channels for the devices
|
||||
|
||||
@@ -148,7 +147,6 @@ The following channels represent universial channels if no further device inform
|
||||
| thermostat | Number | Temperature | Thermostat |
|
||||
| sensorDiscrete | Number | - | SensorDiscrete |
|
||||
|
||||
|
||||
Unsupported Z-Way device types: Camera, SensorMultiline, Text. The integration of these types isn't planned.
|
||||
|
||||
### Channels for the Z-Way Server (Bridge)
|
||||
@@ -169,7 +167,7 @@ Based on the location ID of Z-Way device, the name of the Z-Way room is then all
|
||||
|
||||
### Known issues
|
||||
|
||||
- The Z-Way Binding only works, when simple mode of item linking is enabled during thing creation.
|
||||
- The Z-Way Binding only works, when simple mode of item linking is enabled during thing creation.
|
||||
|
||||
### Structure of Z-Way Binding
|
||||
|
||||
@@ -177,14 +175,14 @@ Based on the location ID of Z-Way device, the name of the Z-Way room is then all
|
||||
|
||||
### Features
|
||||
|
||||
- Discovery of the Z-Way server and devices
|
||||
- Control of the Z-Wave devices in openHAB
|
||||
- Receive updates of sensor data and actuator states in openHAB
|
||||
- Discovery of the Z-Way server and devices
|
||||
- Control of the Z-Wave devices in openHAB
|
||||
- Receive updates of sensor data and actuator states in openHAB
|
||||
|
||||
### Restrictions
|
||||
|
||||
- Z-Way device types (especially the probe types) supported by openHAB channels with detailed information (scale types and so on) are not complete.
|
||||
- Configuration of the Z-Wave network by the binding is currently not possible (physical device configuration)
|
||||
- Only polling is available. Further versions will contain other mechanisms under usage of the WebSocket implementation of Z-Way or MQTT.
|
||||
- Z-Way device types (especially the probe types) supported by openHAB channels with detailed information (scale types and so on) are not complete.
|
||||
- Configuration of the Z-Wave network by the binding is currently not possible (physical device configuration)
|
||||
- Only polling is available. Further versions will contain other mechanisms under usage of the WebSocket implementation of Z-Way or MQTT.
|
||||
|
||||

|
||||
|
||||