[danfossairunit] Add filter period channel (#11371)
* Add filter period channel. Fixes #11310 Signed-off-by: Jacob Laursen <jacob-github@vindvejr.dk> * Round remaining filter life percentage to one decimal. Signed-off-by: Jacob Laursen <jacob-github@vindvejr.dk> * Improve and extend example configuration. Signed-off-by: Jacob Laursen <jacob-github@vindvejr.dk> * Mark filter period channel as advanced due to Link CC/Air Dial conflicts. Signed-off-by: Jacob Laursen <jacob-github@vindvejr.dk> * Add comment about value getting overwritten. Signed-off-by: Jacob Laursen <jacob-github@vindvejr.dk> * Remove redundant parentheses. Signed-off-by: Jacob Laursen <jacob-github@vindvejr.dk> * Fix SCA report: First javadoc author should have 'Initial contribution' contribution description. Signed-off-by: Jacob Laursen <jacob-github@vindvejr.dk> * Fix SCA issue: NoEmptyLineSeparatorCheck Signed-off-by: Jacob Laursen <jacob-github@vindvejr.dk>
This commit is contained in:
@@ -41,6 +41,7 @@ These are the available configuration parameters:
|
||||
| exhaust_temp | recuperator | Number | RO | Temperature of the air when pushed outside |
|
||||
| battery_life | service | Number | RO | Remaining Air Dial Battery Level (percentage) |
|
||||
| filter_life | service | Number | RO | Remaining life of filter until exchange is necessary (percentage) |
|
||||
| filter_period | service | Number | RW | Number of months between filter replacements (between 3 and 12). This value affects calculation of filter_life by the unit, and might get overwritten by Air Dial or Link CC Controller. |
|
||||
|
||||
|
||||
## Full Example
|
||||
@@ -63,21 +64,47 @@ updateUnchangedValuesEveryMillis=30000]
|
||||
### Items
|
||||
|
||||
```
|
||||
Dimmer Lueftung_Drehzahl_Manuell "Drehzahl Lüftung %" (All,Lueftung) {channel = "danfossairunit:airunit:myairunit:main#manual_fan_speed"}
|
||||
Number Lueftung_Drehzahl_Supply "Drehzahl Lüftung Zuluft (rpm)" (All,Lueftung) {channel = "danfossairunit:airunit:myairunit:main#supply_fan_speed"}
|
||||
Number Lueftung_Drehzahl_Extract "Drehzahl Lüftung Abluft (rpm)" (All,Lueftung) {channel = "danfossairunit:airunit:myairunit:main#extract_fan_speed"}
|
||||
String Lueftung_Mode "Betriebsart Lüftung" (All,Lueftung) {channel = "danfossairunit:airunit:myairunit:main#mode"}
|
||||
Switch Lueftung_Boost "Stoßlüftung" (All,Lueftung) {channel = "danfossairunit:airunit:myairunit:main#boost"}
|
||||
Switch Lueftung_Bypass "Lüftung Bypass" (All,Lueftung) {channel = "danfossairunit:airunit:myairunit:recuperator#bypass"}
|
||||
Dimmer DanfossHRV_ManualFanStep "Manual Fan Step [%s]" {channel = "danfossairunit:airunit:myairunit:main#manual_fan_step"}
|
||||
Number DanfossHRV_SupplyFanSpeed "Supply Fan Speed" {channel = "danfossairunit:airunit:myairunit:main#supply_fan_speed"}
|
||||
Number DanfossHRV_ExtractFanSpeed "Extract Fan Speed" {channel = "danfossairunit:airunit:myairunit:main#extract_fan_speed"}
|
||||
String DanfossHRV_Mode "Operation Mode" {channel = "danfossairunit:airunit:myairunit:main#mode"}
|
||||
Switch DanfossHRV_Boost "Boost" {channel = "danfossairunit:airunit:myairunit:main#boost"}
|
||||
Switch DanfossHRV_Bypass "Bypass" {channel = "danfossairunit:airunit:myairunit:recuperator#bypass"}
|
||||
Number:Dimensionless DanfossHRV_Humidity "Relative humidity" <humidity> { channel = "danfossairunit:airunit:myairunit:humidity#humidity" }
|
||||
Number:Temperature DanfossHRV_RoomTemperature "Room air temperatuyre" <temperature> { channel = "danfossairunit:airunit:myairunit:temps#room_temp" }
|
||||
Number:Temperature DanfossHRV_OutdoorTemperature "Outdoor air temperature" <temperature> { channel = "danfossairunit:airunit:myairunit:temps#outdoor_temp" }
|
||||
Number:Temperature DanfossHRV_SupplyAirTemperature "Supply air temperature" <temperature> { channel = "danfossairunit:airunit:myairunit:recuperator#supply_temp" }
|
||||
Number:Temperature DanfossHRV_ExtractAirTemperature "Extract air temperature" <temperature> { channel = "danfossairunit:airunit:myairunit:recuperator#extract_temp" }
|
||||
Number:Temperature DanfossHRV_ExhaustAirTemperature "Exhaust air temperature" <temperature> { channel = "danfossairunit:airunit:myairunit:recuperator#exhaust_temp" }
|
||||
Number DanfossHRV_RemainingFilterLife "Remaining filter life" { channel = "danfossairunit:airunit:myairunit:service#filter_life" }
|
||||
Number DanfossHRV_FilterPeriod "Filter period" { channel = "danfossairunit:airunit:myairunit:service#filter_period" }
|
||||
```
|
||||
|
||||
### Sitemap
|
||||
|
||||
```
|
||||
Slider item=Lueftung_Drehzahl_Manuell
|
||||
Text item=Lueftung_Drehzahl_Supply
|
||||
Text item=Lueftung_Drehzahl_Extract
|
||||
Selection item=Lueftung_Mode mappings=[DEMAND="Bedarfslüftung", OFF="Aus", PROGRAM="Programm", MANUAL="manuell"]
|
||||
Switch item=Lueftung_Boost
|
||||
Switch item=Lueftung_Bypass
|
||||
sitemap danfoss label="Danfoss" {
|
||||
Frame label="Control" {
|
||||
Selection item=DanfossHRV_Mode mappings=[DEMAND="Demand", OFF="Off", PROGRAM="Program", MANUAL="Manual"]
|
||||
Slider item=DanfossHRV_ManualFanStep step=10 visibility=[DanfossHRV_Mode=="MANUAL"]
|
||||
Switch item=DanfossHRV_Bypass
|
||||
Switch item=DanfossHRV_Boost
|
||||
}
|
||||
Frame label="Measurements" {
|
||||
Text item=DanfossHRV_Humidity
|
||||
Text item=DanfossHRV_RoomTemperature
|
||||
Text item=DanfossHRV_OutdoorTemperature
|
||||
Text item=DanfossHRV_SupplyAirTemperature
|
||||
Text item=DanfossHRV_ExtractAirTemperature
|
||||
Text item=DanfossHRV_ExhaustAirTemperature
|
||||
}
|
||||
Frame label="Fan" {
|
||||
Text item=DanfossHRV_SupplyFanSpeed
|
||||
Text item=DanfossHRV_ExtractFanSpeed
|
||||
}
|
||||
Frame label="Filter" {
|
||||
Text item=DanfossHRV_RemainingFilterLife
|
||||
Slider item=DanfossHRV_FilterPeriod minValue=3 maxValue=12
|
||||
}
|
||||
}
|
||||
```
|
||||
|
||||
Reference in New Issue