[ecotouch] Fix description of nviSollKuehlen and coolEnableTemp being writable (#11716)

* Fix description of nviSollKuehlen being writable
* Fix description of coolEnableTemp being writable
* [ecotouch] make channels writable
* [ecotouch] silence compiler warnings
* change example to English

Signed-off-by: Sebastian Held <sebastian.held@gmx.de>
Co-authored-by: Jan Mattner <JanMattner@users.noreply.github.com>
This commit is contained in:
Sebastian Held
2021-12-24 10:36:04 +01:00
committed by GitHub
parent cc47ef7f3e
commit d67c34e2bf
5 changed files with 64 additions and 21 deletions

View File

@@ -64,7 +64,7 @@ Advanced channels:
| Channel ID | Type | Read-Only | Description |
|----------------------------------|----------------------|-----------|-------------------------------------------------------------------------|
| compressor_power | Number:Dimensionless | yes | Percent Power Compressor |
| coolEnableTemp | Number:Temperature | yes | Temperature Cooling Enable |
| coolEnableTemp | Number:Temperature | no | Temperature Cooling Enable |
| date_day | Number:Dimensionless | yes | Day |
| date_month | Number:Dimensionless | yes | Month |
| date_year | Number:Dimensionless | yes | Year |
@@ -85,7 +85,7 @@ Advanced channels:
| maxVLTemp | Number:Temperature | yes | maxVLTemp |
| nviHeizkreisNorm | Number:Temperature | no | nviHeizkreisNorm |
| nviNormAussen | Number:Temperature | no | nviNormAussen |
| nviSollKuehlen | Number:Temperature | yes | nviSollKuehlen |
| nviSollKuehlen | Number:Temperature | no | nviSollKuehlen |
| nviTHeizgrenze | Number:Temperature | no | nviTHeizgrenze |
| nviTHeizgrenzeSoll | Number:Temperature | no | nviTHeizgrenze Setpoint |
| operating_hours_circulation_pump | Number:Time | yes | Operating Hours Circulation Pump |
@@ -179,6 +179,7 @@ Number:Power HeatPump_power_el { channel="ecotouch:geo:heatpump:pow
Number:Power HeatPump_power_th { channel="ecotouch:geo:heatpump:power_heating" }
Number HeatPump_COP_heating { channel="ecotouch:geo:heatpump:cop_heating" }
Number:Temperature HeatPump_adaptHeating { channel="ecotouch:geo:heatpump:adapt_heating" }
Switch HeatPump_state_sourcepump { channel="ecotouch:geo:heatpump:state_sourcepump" }
```
### ecotouch.sitemap
@@ -198,3 +199,21 @@ sitemap ecotouch label="Waterkotte EcoTouch"
Setpoint item=HeatPump_adaptHeating minValue=-2.0 maxValue=2.0 step=0.5
}
```
A snippet to show the current state of the heatpump (you need to have the corresponding items in your .items-file):
```
Text label="State" icon="settings" {
Text item=HeatPump_state_sourcepump label="State Source Pump [%s]" valuecolor=[==ON="green", ==OFF="red"]
Text item=HeatPump_state_heatingpump label="State Heating Pump [%s]" valuecolor=[==ON="green", ==OFF="red"]
Text item=HeatPump_state_evd label="State EVD [%s]" valuecolor=[==ON="green", ==OFF="red"]
Text item=HeatPump_state_compressor1 label="State Compressor 1 [%s]" valuecolor=[==ON="green", ==OFF="red"]
Text item=HeatPump_state_extheater label="State External Heater [%s]" valuecolor=[==ON="green", ==OFF="red"]
Text item=HeatPump_state_alarm label="State Alarm [%s]" valuecolor=[==ON="green", ==OFF="red"]
Text item=HeatPump_state_cooling label="State Cooling [%s]" valuecolor=[==ON="green", ==OFF="red"]
Text item=HeatPump_state_water label="State Water [%s]" valuecolor=[==ON="green", ==OFF="red"]
Text item=HeatPump_state_pool label="State Pool [%s]" valuecolor=[==ON="green", ==OFF="red"]
Text item=HeatPump_state_solar label="State Solar [%s]" valuecolor=[==ON="green", ==OFF="red"]
Text item=HeatPump_state_cooling4way label="State Cooling4Way [%s]" valuecolor=[==ON="green", ==OFF="red"]
}
```