[neohub] check for connection refused (#12906)
Signed-off-by: Andrew Fiddian-Green <software@whitebear.ch>
This commit is contained in:
committed by
GitHub
parent
52bb4b3715
commit
e24ca5708b
@@ -39,7 +39,15 @@ Before the binding can communicate with the hub, the following Configuration Par
|
||||
| portNumber | Port number of the NeoHub (Default=4242) |
|
||||
| pollingInterval | Time (seconds) between polling requests to the NeoHub (Min=4, Max=60, Default=60) |
|
||||
| socketTimeout | Time (seconds) to allow for TCP socket connections to the hub to succeed (Min=4, Max=20, Default=5) |
|
||||
| preferLegacyApi | Prefer if the binding should use the legacy API; this only works so long as the legacy API is still supported; otherwise the binding will switch to the new API anyway (Default=false) |
|
||||
| preferLegacyApi | ADVANCED: Prefer the binding to use older API calls; if these are not supported, it switches to the new calls (Default=false) |
|
||||
|
||||
## Connection Refused Errors
|
||||
|
||||
From early 2022 Heatmiser introduced NeoHub firmware that has the ability to enable / disable the NeoHub `portNumber` 4242.
|
||||
If this port is disabled the OpenHAB binding cannot connect and the binding will report a *"Connection Refused"* warning in the log.
|
||||
In prior firmware versions the port was always enabled.
|
||||
But in the new firmware the port is initially enabled on power up but if no communication occurs for 48 hours it is automatically disabled.
|
||||
Alternatively the Heatmiser mobile App has a setting (Settings | System | API Access | Legacy API Enable | On) whereby the port can be permanently enabled.
|
||||
|
||||
## Thing Configuration for "NeoStat" and "NeoPlug"
|
||||
|
||||
|
||||
Reference in New Issue