@@ -19,7 +19,7 @@ The 'Adam' (from hereon called the gateway) needs to be accessible from the open
|
||||
| - | A Plugwise heating zone configured with at least 1 of the devices below | zone |
|
||||
| [Adam](https://www.plugwise.com/en_US/products/adam-ha) | The Plugwise Home Automation Bridge is needed to connect to the Adam boiler gateway | gateway |
|
||||
| [Tom](https://www.plugwise.com/en_US/products/tom) | A Plugwise Home Automation radiator valve | appliance_valve |
|
||||
| [Floor](https://www.plugwise.com/en_US/products/floor) | A Plugwise Home Automation radiator valve specifically used for floor heating | appliance_valve |
|
||||
| [Floor](https://www.plugwise.com/en_US/products/floor) | A Plugwise Home Automation radiator valve specifically used for floor heating | appliance_valve |
|
||||
| [Circle](https://www.plugwise.com/en_US/products/circle) | A power outlet plug that provides energy measurement and switching control of appliances (e.g. floor heating pump) | appliance_pump |
|
||||
| [Lisa](https://www.plugwise.com/en_US/products/lisa) | A room thermostat (also supports the 'Anna' room thermostat) | appliance_thermostat |
|
||||
| [Boiler] | A central boiler used for heating and/or domestic hot water | appliance_boiler |
|
||||
@@ -39,7 +39,7 @@ You must define a Plugwise Home Automation gateway (Bridge) before defining zone
|
||||
#### Plugwise Home Automation gateway (Bridge):
|
||||
|
||||
| Parameter | Description | Config | Default |
|
||||
| --------- | ----------------------------------------------------------------------- | -------- | ------- |
|
||||
|-----------|-------------------------------------------------------------------------|----------|---------|
|
||||
| host | The IP address or hostname of the Adam HA gateway | Required | 'adam' |
|
||||
| username | The username for the Adam HA gateway | Optional | 'smile' |
|
||||
| smileID | The 8 letter code on the sticker on the back of the Adam boiler gateway | Required | - |
|
||||
@@ -54,14 +54,14 @@ You must define a Plugwise Home Automation gateway (Bridge) before defining zone
|
||||
#### Plugwise Home Automation appliance (`appliance_valve`):
|
||||
|
||||
| Parameter | Description | Config | Default |
|
||||
| -------------------- | ------------------------------------------------------------------------------------------------------------------ | -------- | ------- |
|
||||
|----------------------|--------------------------------------------------------------------------------------------------------------------|----------|---------|
|
||||
| id | The unique ID of the radiator valve appliance | Required | - |
|
||||
| lowBatteryPercentage | Battery charge remaining at which to trigger battery low warning. (*Only applicable for battery operated devices*) | Optional | 15 |
|
||||
|
||||
#### Plugwise Home Automation appliance (`appliance_thermostat`):
|
||||
|
||||
| Parameter | Description | Config | Default |
|
||||
| -------------------- | ------------------------------------------------------------------------------------------------------------------ | -------- | ------- |
|
||||
|----------------------|--------------------------------------------------------------------------------------------------------------------|----------|---------|
|
||||
| id | The unique ID of the room thermostat appliance | Required | - |
|
||||
| lowBatteryPercentage | Battery charge remaining at which to trigger battery low warning. (*Only applicable for battery operated devices*) | Optional | 15 |
|
||||
|
||||
@@ -75,7 +75,7 @@ You must define a Plugwise Home Automation gateway (Bridge) before defining zone
|
||||
#### Plugwise Home Automation boiler (`appliance_boiler`):
|
||||
|
||||
| Parameter | Description | Config | Default |
|
||||
| --------- | --------------------------- | -------- | ------- |
|
||||
|-----------|-----------------------------|----------|---------|
|
||||
| id | The unique ID of the boiler | Required | - |
|
||||
|
||||
## Channels
|
||||
@@ -92,9 +92,11 @@ You must define a Plugwise Home Automation gateway (Bridge) before defining zone
|
||||
| chState | Switch | Yes | The current central heating state of the boiler |
|
||||
| dhwState | Switch | Yes | The current domestic hot water state of the boiler |
|
||||
| waterPressure | Number:Pressure | Yes | The current water pressure of the boiler |
|
||||
| presetScene | String | Yes | The current active scene for the zone |
|
||||
| presetScene | String | No | The current active scene for the zone |
|
||||
| regulationControl | String | No | Toggle current regulation control (Active, Passive, Off) for the zone |
|
||||
| coolingAllowed | Switch | No | Toggle the cooling allowed of a zone ON/OFF |
|
||||
| valvePosition | Number | Yes | The current position of the valve |
|
||||
| preHeat | Switch | Yes | Toggle the pre heating of a zone ON/OFF |
|
||||
| preHeat | Switch | No | Toggle the pre heating of a zone ON/OFF |
|
||||
| coolingState | Switch | Yes | The current cooling state of the boiler |
|
||||
| intendedBoilerTemp | Number:Temperature | Yes | The intended boiler temperature |
|
||||
| flameState | Switch | Yes | The flame state of the boiler |
|
||||
@@ -107,8 +109,6 @@ You must define a Plugwise Home Automation gateway (Bridge) before defining zone
|
||||
| dhwSetpoint | Number:Temperature | Yes | The domestic hot water setpoint |
|
||||
| maxBoilerTemperature | Number:Temperature | Yes | The maximum temperature of the boiler |
|
||||
| dhwComfortMode | Switch | Yes | The domestic hot water confortmode |
|
||||
|
|
||||
|
||||
|
||||
## Full Example
|
||||
|
||||
@@ -131,8 +131,10 @@ Replace `$device_id` accordingly.
|
||||
```
|
||||
Number:Temperature living_room_zone_temperature "Zone temperature" {channel="plugwiseha:zone:home:living_room_zone:temperature"}
|
||||
Number:Temperature living_room_zone_temperature_setpoint "Zone temperature setpoint" {channel="plugwiseha:zone:home:living_room_zone:setpointTemperature"}
|
||||
Number:Temperature living_room_zone_preset_scene "Zone preset scene" {channel="plugwiseha:zone:home:living_room_zone:presetScene"}
|
||||
String living_room_zone_preset_scene "Zone preset scene" {channel="plugwiseha:zone:home:living_room_zone:presetScene"}
|
||||
Switch living_room_zone_preheat "Zone preheat enabled" {channel="plugwiseha:zone:home:living_room_zone:preHeat"}
|
||||
String living_room_zone_cooling "Zone cooling enabled" {channel="plugwiseha:zone:home:living_room_zone:coolingAllowed"}
|
||||
String living_room_zone_regulation_control "Zone regulation control" {channel="plugwiseha:zone:home:living_room_zone:regulationControl"}
|
||||
|
||||
Number:Temperature living_room_radiator_temperature "Radiator valve temperature" {channel="plugwiseha:appliance_valve:home:living_room_radiator:temperature"}
|
||||
Number:Temperature living_room_radiator_temperature_setpoint "Radiator valve temperature setpoint" {channel="plugwiseha:appliance_valve:home:living_room_radiator:setpointTemperature"}
|
||||
@@ -181,6 +183,8 @@ sitemap plugwiseha label="PlugwiseHA Binding"
|
||||
Setpoint item=living_room_zone_temperature_setpoint label="Living room [%.1f °C]" minValue=5.0 maxValue=25 step=0.5
|
||||
Text item=living_room_zone_presetScene
|
||||
Switch item=living_room_zone_preheat
|
||||
Text item=living_room_zone_regulation_control
|
||||
Switch item=living_room_zone_cooling
|
||||
|
||||
Text item=living_room_radiator_temperature
|
||||
Setpoint item=living_room_radiator_temperature_setpoint label="Living room [%.1f °C]" minValue=5.0 maxValue=25 step=0.5
|
||||
|
||||
Reference in New Issue
Block a user