[nikohomecontrol] Bug fixes and improvements to thermostats (#11963)
* Thermostat fixes and implement extra thermostat channels Signed-off-by: Mark Herwege <mark.herwege@telenet.be>
This commit is contained in:
@@ -237,19 +237,25 @@ OnOff, IncreaseDecrease and Percent command types are supported.
|
||||
Note that sending an ON command will switch the dimmer to the value stored when last turning the dimmer off, or 100% depending on the configuration in the Niko Home Control Controller.
|
||||
This can be changed with the Niko Home Control programming software.
|
||||
|
||||
For thing type `blind` the supported channel is `rollershutter`. UpDown, StopMove and Percent command types are supported.
|
||||
For thing type `blind` the supported channel is `rollershutter`.
|
||||
UpDown, StopMove and Percent command types are supported.
|
||||
|
||||
For thing type `thermostat` the supported channels are `measured`, `mode`, `setpoint`, `overruletime` and `demand`.
|
||||
For thing type `thermostat` the supported channels are `measured`, `heatingmode`, `mode`, `setpoint`, `overruletime`, `heatingdemand` and `demand`.
|
||||
`measured` gives the current temperature in QuantityType<Temperature>, allowing for different temperature units.
|
||||
This channel is read only.
|
||||
`mode` can be set and shows the current thermostat mode.
|
||||
Allowed values are 0 (day), 1 (night), 2 (eco), 3 (off), 4 (cool), 5 (prog 1), 6 (prog 2), 7 (prog 3).
|
||||
If mode is set, the `setpoint` temperature will return to its standard value from the mode.
|
||||
`setpoint` can be set and shows the current thermostat setpoint value in QuantityType<Temperature>.
|
||||
`heatingmode` can be set and shows the current thermostat mode.
|
||||
Allowed values are Day, Night, Eco, Off, Cool, Prog1, Prog2, Prog3.
|
||||
As an alternative to `heatingmode` and for backward compatibility, the advanced channel `mode` is provided.
|
||||
This channel has the same meaning, but with numeric values (0=Day, 1=Night, 2=Eco, 3=Off, 4=Cool, 5=Prog1, 6=Prog2, 7=Prog3) instead of string values.
|
||||
If `heatingmode` or `mode` is set, the `setpoint` temperature will return to the standard value for the mode as defined in Niko Home Control.
|
||||
`setpoint` shows the current thermostat setpoint value in QuantityType<Temperature>.
|
||||
When updating `setpoint`, it will overrule the temperature setpoint defined by the thermostat mode for `overruletime` duration.
|
||||
`overruletime` is used to set the total duration to apply the setpoint temperature set in the setpoint channel before the thermostat returns to the setting in its mode.
|
||||
`demand` is a number indicating of the system is actively heating/cooling.
|
||||
`overruletime` is used to set the total duration to apply the setpoint temperature set in the setpoint channel before the thermostat returns to the setting from its mode.
|
||||
`heatingdemand` is a string indicating if the system is actively heating/cooling.
|
||||
This channel will have value Heating, Cooling or None.
|
||||
As an alternative to `heatingdemand`, the advanced channel `demand` is provided.
|
||||
The value will be 1 for heating, -1 for cooling and 0 if not heating or cooling.
|
||||
`heatingdemand` and `demand` are read only channels.
|
||||
Note that cooling in NHC I is set by the binding, and will incorrectly show cooling demand when the system does not have cooling capabilities.
|
||||
In NHC II, `measured` and `setpoint` temperatures will always report in 0.5°C increments due to a Niko Home Control II API restriction.
|
||||
|
||||
@@ -310,12 +316,12 @@ Switch AllOff {channel="nikohomecontrol:onOff:nhc1:1:button"}
|
||||
Switch LivingRoom {channel="nikohomecontrol:onOff:nhc1:2:switch"} # Switch for onOff type action
|
||||
Dimmer TVRoom {channel="nikohomecontrol:dimmer:nhc1:3:brightness"} # Changing brightness dimmer type action
|
||||
Rollershutter Kitchen {channel="nikohomecontrol:blind:nhc1:4:rollershutter"} # Controlling rollershutter or blind type action
|
||||
Number:Temperature CurTemperature "[%.1f °F]" {channel="nikohomecontrol:thermostat:nhc1:5:measured"} # Getting measured temperature from thermostat in °F, read only
|
||||
Number ThermostatMode {channel="nikohomecontrol:thermostat:nhc1:5:mode"} # Get and set thermostat mode
|
||||
Number:Temperature SetTemperature "[%.1f °C]" {channel="nikohomecontrol:thermostat:nhc1:5:setpoint"} # Get and set target temperature in °C
|
||||
Number OverruleDuration {channel="nikohomecontrol:thermostat:nhc1:5:overruletime"} # Get and set the overrule time
|
||||
Number ThermostatDemand {channel="nikohomecontrol:thermostat:nhc1:5:demand"} # Get the current heating/cooling demand
|
||||
Number:Power CurPower "[%.0f W]" {channel="nikohomecontrol:energyMeter:nhc2:6:power"} # Get current power consumption
|
||||
Number:Temperature CurTemperature "[%.1f °F]" {channel="nikohomecontrol:thermostat:nhc1:5:measured"} # Getting measured temperature from thermostat in °F, read only
|
||||
String ThermostatMode {channel="nikohomecontrol:thermostat:nhc1:5:heatingmode"} # Get and set thermostat mode
|
||||
Number:Temperature SetTemperature "[%.1f °C]" {channel="nikohomecontrol:thermostat:nhc1:5:setpoint"} # Get and set target temperature in °C
|
||||
Number OverruleDuration {channel="nikohomecontrol:thermostat:nhc1:5:overruletime"} # Get and set the overrule time
|
||||
String ThermostatDemand {channel="nikohomecontrol:thermostat:nhc1:5:heatingdemand"} # Get the current heating/cooling demand
|
||||
Number:Power CurPower "[%.0f W]" {channel="nikohomecontrol:energyMeter:nhc2:6:power"} # Get current power consumption
|
||||
```
|
||||
|
||||
.sitemap:
|
||||
@@ -327,7 +333,7 @@ Slider item=TVRoom
|
||||
Switch item=TVRoom # allows switching dimmer item off or on (with controller defined behavior)
|
||||
Rollershutter item=Kitchen
|
||||
Text item=CurTemperature
|
||||
Selection item=ThermostatMode mappings=[0="day", 1="night", 2="eco", 3="off", 4="cool", 5="prog 1", 6="prog 2", 7="prog 3"]
|
||||
Selection item=ThermostatMode mappings=[Day="day", Night="night", Eco="eco", Off="off", Prog1="Away"]
|
||||
Setpoint item=SetTemperature minValue=0 maxValue=30
|
||||
Slider item=OverruleDuration minValue=0 maxValue=120
|
||||
Text item=Power
|
||||
|
||||