[shelly] Add Shelly Motion, minor improvements (#10054)
* Support for Shelly Motion, some minotr improvements, README updated Signed-off-by: Markus Michels <markus7017@gmail.com> * minor changes Signed-off-by: Markus Michels <markus7017@gmail.com> * Bug fixes from hardening Signed-off-by: Markus Michels <markus7017@gmail.com> * review changes applied Signed-off-by: Markus Michels <markus7017@gmail.com> * review change Signed-off-by: Markus Michels <markus7017@gmail.com> * review changes, fix creations of sensors#motion and device#externalPower for H%T; moved images/uiroller*.png to doc/images Signed-off-by: Markus Michels <markus7017@gmail.com> * missing in last fix Signed-off-by: Markus Michels <markus7017@gmail.com>
This commit is contained in:
@@ -30,6 +30,7 @@ Refer to [Advanced Users](doc/AdvancedUsers.md) for more information on openHAB
|
||||
| shellydimmer | Shelly Dimmer | SHDM-1 |
|
||||
| shellydimmer2 | Shelly Dimmer2 | SHDM-2 |
|
||||
| shellyix3 | Shelly ix3 | SHIX3-1 |
|
||||
| shellyuni | Shelly UNI | SHUNI-1 |
|
||||
| shellyplug | Shelly Plug | SHPLG2-1 |
|
||||
| shellyplugs | Shelly Plug-S | SHPLG-S |
|
||||
| shellyem | Shelly EM with integrated Power Meters | SHEM |
|
||||
@@ -578,6 +579,23 @@ Using the Thing configuration option `brightnessAutoOn` you could decide if the
|
||||
| |lastEvent |String |yes |S/SS/SSS for 1/2/3x Shortpush or L for Longpush |
|
||||
| |eventCount |Number |yes |Counter gets incremented every time the device issues a button event. |
|
||||
|
||||
### Shelly UNI - Low voltage sensor/actor: shellyuni)
|
||||
|
||||
|Group |Channel |Type |read-only|Description |
|
||||
|----------|-------------|---------|---------|----------------------------------------------------------------------------|
|
||||
|relay1 | | | |See group relay1 for Shelly 2, no autoOn/autoOff/timerActive channels |
|
||||
|relay2 | | | |See group relay1 for Shelly 2, no autoOn/autoOff/timerActive channels |
|
||||
|sensors |temperature1 |Number |yes |Temperature value of external sensor #1 (if connected to temp/hum addon) |
|
||||
| |temperature2 |Number |yes |Temperature value of external sensor #2 (if connected to temp/hum addon) |
|
||||
| |temperature3 |Number |yes |Temperature value of external sensor #3 (if connected to temp/hum addon) |
|
||||
| |humidity |Number |yes |Humidity in percent (if connected to temp/hum addon) |
|
||||
| |voltage |Number |yes |ADCS voltage |
|
||||
|status |input1 |Switch |yes |State of Input 1 |
|
||||
| |input2 |Switch |yes |State of Input 2 |
|
||||
| |button |Trigger |yes |Event trigger, see section Button Events |
|
||||
| |lastEvent |String |yes |S/SS/SSS for 1/2/3x Shortpush or L for Longpush |
|
||||
| |eventCount |Number |yes |Counter gets incremented every time the device issues a button event. |
|
||||
|
||||
### Shelly Bulb (thing-type: shellybulb)
|
||||
|
||||
|Group |Channel |Type |read-only|Description |
|
||||
|
||||
Reference in New Issue