[fronius] Add support for Fronius Smart Meter (#9209)
* [fronius] Add support for Fronius Smart Meter * [fronius] Use DTO, implement UoM * [fronius] fix README.md * [fronius] Add mandatory label for channel-type and fix property update * [fronius] Store meterRealtimeBodyData instead of meterRealtimeResponse Signed-off-by: Jimmy Tanagra <jcode@tanagra.id.au>
This commit is contained in:
@@ -1,12 +1,16 @@
|
||||
# Fronius Binding
|
||||
|
||||
This binding uses the [Fronius Solar API V1](https://www.fronius.com/en/photovoltaics/products/all-products/system-monitoring/open-interfaces/fronius-solar-api-json-) to obtain data from a Fronius devices.
|
||||
This binding uses the [Fronius Solar API V1](https://www.fronius.com/en/photovoltaics/products/all-products/system-monitoring/open-interfaces/fronius-solar-api-json-) to obtain data from Fronius devices.
|
||||
|
||||
It supports Fronius inverters and Fronius Smart Meter. Tested with a Fronius Symo 8.2-3-M and Fronius Smart Meter 63A.
|
||||
|
||||
## Supported Things
|
||||
|
||||
Support Fronius Galvo, Fronius Symo inverters and other Fronius inverters in combination with the Fronius Datamanager 1.0 / 2.0 or Fronius Datalogger.
|
||||
You can add multiple inverters that depend on the same datalogger with different device ids. (Default 1)
|
||||
| Thing Type | Description |
|
||||
| --------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
|
||||
| `bridge` | The Bridge |
|
||||
| `powerinverter` | Fronius Galvo, Symo and other Fronius inverters in combination with the Fronius Datamanager 1.0 / 2.0 or Fronius Datalogger. You can add multiple inverters that depend on the same datalogger with different device ids. (Default 1) |
|
||||
| `meter` | Fronius Smart Meter. You can add multiple smart meters with different device ids. (The default id = 0) |
|
||||
|
||||
## Discovery
|
||||
|
||||
@@ -14,41 +18,83 @@ There is no discovery implemented. You have to create your things manually and s
|
||||
|
||||
## Binding Configuration
|
||||
|
||||
The binding has no configuration options, all configuration is done at `bridge` or `powerinverter` level.
|
||||
The binding has no configuration options, all configuration is done at `bridge`, `powerinverter` or `meter` level.
|
||||
|
||||
## Thing Configuration
|
||||
|
||||
### Bridge Thing Configuration
|
||||
|
||||
| Parameter | Description |
|
||||
|-----------------|------------------------------------------------------ |
|
||||
| hostname | The hostname or IP address of your Fronius Datalogger |
|
||||
| refreshInterval | Refresh interval in seconds |
|
||||
| Parameter | Description |
|
||||
| ----------------- | ----------------------------------------------------- |
|
||||
| `hostname` | The hostname or IP address of your Fronius Datalogger |
|
||||
| `refreshInterval` | Refresh interval in seconds |
|
||||
|
||||
### Powerinverter Thing Configuration
|
||||
|
||||
| Parameter | Description |
|
||||
|-----------------|------------------------------------------------------ |
|
||||
| deviceId | The identifier of your device (Default: 1) |
|
||||
| Parameter | Description |
|
||||
| ---------- | ------------------------------------------ |
|
||||
| `deviceId` | The identifier of your device (Default: 1) |
|
||||
|
||||
### Meter Thing Configuration
|
||||
|
||||
| Parameter | Description |
|
||||
| ---------- | ----------------------------------------------- |
|
||||
| `deviceId` | The identifier of your smart meter (Default: 0) |
|
||||
|
||||
## Channels
|
||||
|
||||
| Channel ID | Item Type | Description |
|
||||
|------------|--------------|------------------------- |
|
||||
| inverterdatachanneldayenergy | Number | Energy generated on current day |
|
||||
| inverterdatachannelpac | Number | AC powery |
|
||||
| inverterdatachanneltotal | Number | Energy generated overall |
|
||||
| inverterdatachannelyear | Number | Energy generated in current year |
|
||||
| inverterdatachannelfac | Number | AC frequency |
|
||||
| inverterdatachanneliac | Number | AC current |
|
||||
| inverterdatachannelidc | Number | DC current |
|
||||
| inverterdatachanneluac | Number | AC voltage |
|
||||
| inverterdatachanneludc | Number | DC voltage |
|
||||
| inverterdatadevicestatuserrorcode | Number | Device error code |
|
||||
| inverterdatadevicestatusstatuscode | Number | Device status code<br />`0` - `6` Startup<br />`7` Running <br />`8` Standby<br />`9` Bootloading<br />`10` Error |
|
||||
| powerflowchannelpgrid | Number | Power + from grid, - to grid |
|
||||
| powerflowchannelpload | Number | Power + generator, - consumer |
|
||||
| powerflowchannelpakku | Number | Power + charge, - discharge |
|
||||
### Channels for `powerinverter` Thing
|
||||
|
||||
| Channel ID | Item Type | Description |
|
||||
| ------------------------------------ | --------- | ----------------------------------------------------------------------------------------------------------------- |
|
||||
| `inverterdatachanneldayenergy` | Number | Energy generated on current day |
|
||||
| `inverterdatachannelpac` | Number | AC power |
|
||||
| `inverterdatachanneltotal` | Number | Energy generated overall |
|
||||
| `inverterdatachannelyear` | Number | Energy generated in current year |
|
||||
| `inverterdatachannelfac` | Number | AC frequency |
|
||||
| `inverterdatachanneliac` | Number | AC current |
|
||||
| `inverterdatachannelidc` | Number | DC current |
|
||||
| `inverterdatachanneluac` | Number | AC voltage |
|
||||
| `inverterdatachanneludc` | Number | DC voltage |
|
||||
| `inverterdatadevicestatuserrorcode` | Number | Device error code |
|
||||
| `inverterdatadevicestatusstatuscode` | Number | Device status code<br />`0` - `6` Startup<br />`7` Running <br />`8` Standby<br />`9` Bootloading<br />`10` Error |
|
||||
| `powerflowchannelpgrid` | Number | Power + from grid, - to grid |
|
||||
| `powerflowchannelpload` | Number | Power + generator, - consumer |
|
||||
| `powerflowchannelpakku` | Number | Power + charge, - discharge |
|
||||
|
||||
### Channels for `meter` Thing
|
||||
|
||||
| Channel ID | Item Type | Description |
|
||||
| ----------------------- | ------------------------ | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ |
|
||||
| `enable` | Number | 1 = enabled, 0 = disabled |
|
||||
| `location` | Number | 0 = grid interconnection point (primary meter)<br/> 1 = load (primary meter) <br />3 = external generator (secondary meters)(multiple)<br />256-511 = subloads (secondary meters)(unique). Refer to Fronius Solar API. |
|
||||
| `currentacphase1` | Number:ElectricCurrent | AC Current on Phase 1 |
|
||||
| `currentacphase2` | Number:ElectricCurrent | AC Current on Phase 2 |
|
||||
| `currentacphase3` | Number:ElectricCurrent | AC Current on Phase 3 |
|
||||
| `voltageacphase1` | Number:ElectricPotential | AC Voltage on Phase 1 |
|
||||
| `voltageacphase2` | Number:ElectricPotential | AC Voltage on Phase 2 |
|
||||
| `voltageacphase3` | Number:ElectricPotential | AC Voltage on Phase 3 |
|
||||
| `powerrealphase1` | Number:Power | Real Power on Phase 1 |
|
||||
| `powerrealphase2` | Number:Power | Real Power on Phase 2 |
|
||||
| `powerrealphase3` | Number:Power | Real Power on Phase 3 |
|
||||
| `powerfactorphase1` | Number | Power Factor on Phase 1 |
|
||||
| `powerfactorphase2` | Number | Power Factor on Phase 2 |
|
||||
| `powerfactorphase3` | Number | Power Factor on Phase 3 |
|
||||
| `energyrealsumconsumed` | Number:Energy | Real Energy consumed |
|
||||
| `energyrealsumproduced` | Number:Energy | Real Energy produced |
|
||||
| |
|
||||
|
||||
|
||||
|
||||
|
||||
## Properties
|
||||
|
||||
The `meter` thing has the following properties:
|
||||
|
||||
| Property | Description |
|
||||
| -------- | ------------------------------ |
|
||||
| `model` | The model name of the meter |
|
||||
| `serial` | The serial number of the meter |
|
||||
|
||||
## Full Example
|
||||
|
||||
@@ -57,13 +103,14 @@ demo.things:
|
||||
```
|
||||
Bridge fronius:bridge:mybridge [hostname="192.168.66.148", refreshInterval=5] {
|
||||
Thing powerinverter myinverter [deviceId=1]
|
||||
Thing meter mymeter [deviceId=0]
|
||||
}
|
||||
```
|
||||
|
||||
demo.items:
|
||||
|
||||
```
|
||||
Number AC_Powery { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachannelpac" }
|
||||
Number AC_Power { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachannelpac" }
|
||||
Number Day_Energy { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachanneldayenergy" }
|
||||
Number Total_Energy { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachanneltotal" }
|
||||
Number Year_Energy { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachannelyear" }
|
||||
@@ -77,6 +124,21 @@ Number StatusCode { channel="fronius:powerinverter:mybridge:myinverter:inverterd
|
||||
Number Grid_Power { channel="fronius:powerinverter:mybridge:myinverter:powerflowchannelpgrid" }
|
||||
Number Load_Power { channel="fronius:powerinverter:mybridge:myinverter:powerflowchannelpload" }
|
||||
Number Battery_Power { channel="fronius:powerinverter:mybridge:myinverter:powerflowchannelpakku" }
|
||||
```
|
||||
|
||||
Tested with a Fronius Symo 8.2-3-M
|
||||
Number Meter_Enable { channel="fronius:meter:mybridge:mymeter:enable" }
|
||||
Number Meter_Location { channel="fronius:meter:mybridge:mymeter:location" }
|
||||
Number:ElectricCurrent Meter_CurrentPhase1 { channel="fronius:meter:mybridge:mymeter:currentacphase1" }
|
||||
Number:ElectricCurrent Meter_CurrentPhase2 { channel="fronius:meter:mybridge:mymeter:currentacphase2" }
|
||||
Number:ElectricCurrent Meter_CurrentPhase3 { channel="fronius:meter:mybridge:mymeter:currentacphase3" }
|
||||
Number:Voltage Meter_VoltagePhase1 { channel="fronius:meter:mybridge:mymeter:voltageacphase1" }
|
||||
Number:Voltage Meter_VoltagePhase2 { channel="fronius:meter:mybridge:mymeter:voltageacphase2" }
|
||||
Number:Voltage Meter_VoltagePhase3 { channel="fronius:meter:mybridge:mymeter:voltageacphase3" }
|
||||
Number:Power Meter_PowerPhase1 { channel="fronius:meter:mybridge:mymeter:powerrealphase1" }
|
||||
Number:Power Meter_PowerPhase2 { channel="fronius:meter:mybridge:mymeter:powerrealphase2" }
|
||||
Number:Power Meter_PowerPhase3 { channel="fronius:meter:mybridge:mymeter:powerrealphase3" }
|
||||
Number Meter_PowerFactorPhase1 { channel="fronius:meter:mybridge:mymeter:powerfactorphase1" }
|
||||
Number Meter_PowerFactorPhase2 { channel="fronius:meter:mybridge:mymeter:powerfactorphase2" }
|
||||
Number Meter_PowerFactorPhase3 { channel="fronius:meter:mybridge:mymeter:powerfactorphase3" }
|
||||
Number:Energy Meter_EnergyConsumed { channel="fronius:meter:mybridge:mymeter:energyrealsumconsumed" }
|
||||
Number:Energy Meter_EnergyProduced { channel="fronius:meter:mybridge:mymeter:energyrealsumproduced" }
|
||||
```
|
||||
|
||||
Reference in New Issue