Fronius Binding
This binding uses the Fronius Solar API V1 to obtain data from Fronius devices.
It supports Fronius inverters and Fronius Smart Meter. Supports:
Fronius Symo
Fronius Symo Gen24
Fronius Smart Meter 63A
Fronius Smart Meter TS 65A-3
Fronius Ohmpilot
Supported Things
Thing Type
Description
bridge
The Bridge
powerinverter
Fronius Galvo, Symo and other Fronius inverters in combination with the Fronius Datamanager 1.0 / 2.0 or Fronius Datalogger. You can add multiple inverters that depend on the same datalogger with different device ids. (Default 1)
meter
Fronius Smart Meter. You can add multiple smart meters with different device ids. (The default id = 0)
ohmpilot
Fronius Ohmpilot. (The default id = 0)
Discovery
There is no discovery implemented. You have to create your things manually and specify the hostname or IP address of the Datalogger and the device id.
Binding Configuration
The binding has no configuration options, all configuration is done at bridge
, powerinverter
, meter
or ohmpilot
level.
Thing Configuration
Bridge Thing Configuration
Parameter
Description
hostname
The hostname or IP address of your Fronius Datalogger
refreshInterval
Refresh interval in seconds
Powerinverter Thing Configuration
Parameter
Description
deviceId
The identifier of your device (Default: 1)
Meter Thing Configuration
Parameter
Description
deviceId
The identifier of your smart meter (Default: 0)
Ohmpilot Thing Configuration
Parameter
Description
deviceId
The identifier of your ohmpilot (Default: 0)
Channels
Channels for powerinverter
Thing
Channel ID
Item Type
Description
inverterdatachannelpac
Number:Power
Power generated
inverterdatachannelfac
Number:Frequency
AC frequency
inverterdatachanneliac
Number:ElectricCurrent
AC current
inverterdatachannelidc
Number:ElectricCurrent
DC current
inverterdatachanneluac
Number:ElectricPotential
AC voltage
inverterdatachanneludc
Number:ElectricPotential
DC voltage
inverterdatachanneldayenergy
Number:Energy
Energy generated on current day
inverterdatachannelyear
Number:Energy
Energy generated in current year
inverterdatachanneltotal
Number:Energy
Energy generated overall
inverterdatadevicestatuserrorcode
Number
Device error code
inverterdatadevicestatusstatuscode
Number
Device status code0
- 6
Startup7
Running 8
Standby9
Bootloading10
Error
powerflowchannelpgrid
Number:Power
Grid Power (+ from grid, - to grid)
powerflowchannelpload
Number:Power
Load Power (+ generator, - consumer)
powerflowchannelpakku
Number:Power
Battery Power (+ charge, - discharge)
powerflowchannelppv
Number:Power
Solar Power (+ production)
powerflowautonomy
Number:Dimensionless
The current relative autonomy in %
powerflowselfconsumption
Number:Dimensionless
The current relative self consumption in %
powerflowinverter1power
Number:Power
Current power of inverter 1, null if not running (+ produce/export, - consume/import)
powerflowinverter1soc
Number:Dimensionless
Current state of charge of inverter 1 in percent
Channels for meter
Thing
Channel ID
Item Type
Description
enable
Number
1 = enabled, 0 = disabled
location
Number
0 = grid interconnection point (primary meter) 1 = load (primary meter) 3 = external generator (secondary meters)(multiple) 256-511 = subloads (secondary meters)(unique). Refer to Fronius Solar API.
currentacphase1
Number:ElectricCurrent
AC Current on Phase 1
currentacphase2
Number:ElectricCurrent
AC Current on Phase 2
currentacphase3
Number:ElectricCurrent
AC Current on Phase 3
voltageacphase1
Number:ElectricPotential
AC Voltage on Phase 1
voltageacphase2
Number:ElectricPotential
AC Voltage on Phase 2
voltageacphase3
Number:ElectricPotential
AC Voltage on Phase 3
powerrealphase1
Number:Power
Real Power on Phase 1
powerrealphase2
Number:Power
Real Power on Phase 2
powerrealphase3
Number:Power
Real Power on Phase 3
powerrealsum
Number:Power
Real Power summed up
powerfactorphase1
Number
Power Factor on Phase 1
powerfactorphase2
Number
Power Factor on Phase 2
powerfactorphase3
Number
Power Factor on Phase 3
energyrealsumconsumed
Number:Energy
Real Energy consumed
energyrealsumproduced
Number:Energy
Real Energy produced
Channels for ohmpilot
Thing
Channel ID
Item Type
Description
energyrealsumconsumed
Number:Energy
Real Energy consumed
powerrealsum
Number:Power
Real Power
temperaturechannel1
Number:Temperature
Temperature
errorcode
Number
Device error code
statecode
Number
Device state code0
up and running 1
keep minimum temperature 2
legionella protection 3
critical fault4
fault5
boost mode
Properties
The meter
thing has the following properties:
Property
Description
modelId
The model name of the meter
serialNumber
The serial number of the meter
The ohmpilot
thing has the following property:
Property
Description
modelId
The model name of the ohmpilot
serialNumber
The serial number of the ohmpilot
Full Example
demo.things:
Bridge fronius:bridge:mybridge [hostname="192.168.66.148", refreshInterval=5] {
Thing powerinverter myinverter [deviceId=1]
Thing meter mymeter [deviceId=0]
Thing ohmpilot myohmpilot [deviceId=0]
}
demo.items:
Number:Power AC_Power { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachannelpac" }
Number:Energy Day_Energy { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachanneldayenergy" }
Number:Energy Total_Energy { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachanneltotal" }
Number:Energy Year_Energy { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachannelyear" }
Number:Frequency FAC { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachannelfac" }
Number:ElectricCurrent IAC { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachanneliac" }
Number:ElectricCurrent IDC { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachannelidc" }
Number:ElectricPotential UAC { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachanneluac" }
Number:ElectricPotential UDC { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachanneludc" }
Number ErrorCode { channel="fronius:powerinverter:mybridge:myinverter:inverterdatadevicestatuserrorcode" }
Number StatusCode { channel="fronius:powerinverter:mybridge:myinverter:inverterdatadevicestatusstatuscode" }
Number:Power Grid_Power { channel="fronius:powerinverter:mybridge:myinverter:powerflowchannelpgrid" }
Number:Power Load_Power { channel="fronius:powerinverter:mybridge:myinverter:powerflowchannelpload" }
Number:Power Battery_Power { channel="fronius:powerinverter:mybridge:myinverter:powerflowchannelpakku" }
Number:Power Production_Power { channel="fronius:powerinverter:mybridge:myinverter:powerflowchannelppv" }
Number:Dimensionless Power_Autonomy { channel="fronius:powerinverter:mybridge:myinverter:powerflowautonomy" }
Number:Dimensionless Power_SelfConsumption { channel="fronius:powerinverter:mybridge:myinverter:powerflowselfconsumption" }
Number:Power Inverter1_Power { channel="fronius:powerinverter:mybridge:myinverter:powerflowinverter1power" }
Number:Dimensionless Inverter1_SOC { channel="fronius:powerinverter:mybridge:myinverter:powerflowinverter1soc" }
Number Meter_Enable { channel="fronius:meter:mybridge:mymeter:enable" }
Number Meter_Location { channel="fronius:meter:mybridge:mymeter:location" }
Number:ElectricCurrent Meter_CurrentPhase1 { channel="fronius:meter:mybridge:mymeter:currentacphase1" }
Number:ElectricCurrent Meter_CurrentPhase2 { channel="fronius:meter:mybridge:mymeter:currentacphase2" }
Number:ElectricCurrent Meter_CurrentPhase3 { channel="fronius:meter:mybridge:mymeter:currentacphase3" }
Number:Voltage Meter_VoltagePhase1 { channel="fronius:meter:mybridge:mymeter:voltageacphase1" }
Number:Voltage Meter_VoltagePhase2 { channel="fronius:meter:mybridge:mymeter:voltageacphase2" }
Number:Voltage Meter_VoltagePhase3 { channel="fronius:meter:mybridge:mymeter:voltageacphase3" }
Number:Power Meter_PowerPhase1 { channel="fronius:meter:mybridge:mymeter:powerrealphase1" }
Number:Power Meter_PowerPhase2 { channel="fronius:meter:mybridge:mymeter:powerrealphase2" }
Number:Power Meter_PowerPhase3 { channel="fronius:meter:mybridge:mymeter:powerrealphase3" }
Number:Power Meter_PowerSum { channel="fronius:meter:mybridge:mymeter:powerrealsum" }
Number Meter_PowerFactorPhase1 { channel="fronius:meter:mybridge:mymeter:powerfactorphase1" }
Number Meter_PowerFactorPhase2 { channel="fronius:meter:mybridge:mymeter:powerfactorphase2" }
Number Meter_PowerFactorPhase3 { channel="fronius:meter:mybridge:mymeter:powerfactorphase3" }
Number:Energy Meter_EnergyConsumed { channel="fronius:meter:mybridge:mymeter:energyrealsumconsumed" }
Number:Energy Meter_EnergyProduced { channel="fronius:meter:mybridge:mymeter:energyrealsumproduced" }
Number:Energy Ohmpilot_EnergyConsumed { channel="fronius:ohmpilot:mybridge:myohmpilot:energyrealsumconsumed" }
Number:Power Ohmpilot_PowerSum { channel="fronius:ohmpilot:mybridge:myohmpilot:powerrealsum" }
Number:Temperature Ohmpilot_Temperature { channel="fronius:ohmpilot:mybridge:myohmpilot:temperaturechannel1" }
Number Ohmpilot_State { channel="fronius:ohmpilot:mybridge:myohmpilot:statecode" }
Number Ohmpilot_Errorcode { channel="fronius:ohmpilot:mybridge:myohmpilot:errorcode" }
Note: Make sure to turn on the Night Mode in the Display Settings on the Fronius inverter to keep it from going offline at night.