[somfytahoma] added support for the Shutter thing (#12495)

Signed-off-by: Ondrej Pecta <opecta@gmail.com>
This commit is contained in:
Ondrej Pecta
2022-03-27 19:04:00 +02:00
committed by GitHub
parent c81506b44d
commit 0c2901f3ed
7 changed files with 228 additions and 113 deletions

View File

@@ -21,6 +21,7 @@ Any home automation system based on the OverKiz API is potentially supported.
- awnings (UP, DOWN, STOP control of an awning). IO Homecontrol devices are allowed to set exact position of an awning (0-100%)
- windows (UP, DOWN, STOP control of a window). IO Homecontrol devices are allowed to set exact position of a window (0-100%)
- pergolas (UP, DOWN, STOP control of a pergola). IO Homecontrol devices are allowed to set exact position of a pergola (0-100%)
- shutters (OPEN, CLOSE, STOP control of a shutter)
- on/off switches (connected by RTS, IO protocol or supported by USB stick - z-wave, enocean, ..)
- light switches (similar to on/off)
- dimmer lights (light switches with intensity setting)
@@ -63,116 +64,116 @@ Please see the example below.
## Channels
| Thing | Channel | Note |
|-------------------------------------------------------------------------------|---------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| bridge | N.A | bridge does not expose any channel |
| gateway | status | status of your gateway |
| gateway | scenarios | used to run the scenarios defined in the cloud portal |
| gate | gate_command | used for controlling your gate (open, close, stop, pedestrian) |
| gate | gate_state | get state of your gate (open, closed, pedestrian) |
| gate | gate_position | get position (0-100%) of your gate (where supported) |
| roller shutter, screen, venetian blind, garage door, awning, pergola, curtain | control | device controller which reacts to commands UP/DOWN/ON/OFF/OPEN/CLOSE/MY/STOP + closure 0-100 |
| window | control | device controller which reacts to commands UP/DOWN/ON/OFF/OPEN/CLOSE/STOP + closure 0-100 |
| silent roller shutter | silent_control | similar to control channel but in silent mode |
| venetian blind, adjustable slats roller shutter, bioclimatic pergola | orientation | percentual orientation of the blind's slats, it can have value 0-100. For IO Homecontrol devices only (non RTS) |
| venetian blind, adjustable slats roller shutter | closure_orientation | percentual closure and orientation of the blind's slats, it can have value 0-100. For IO Homecontrol devices only (non RTS) |
| adjustable slats roller shutter | rocker | used for setting the rocker position of the roller shutter, the only position allowing the slats control |
| bioclimatic pergola | slats | slats state (open/closed) |
| bioclimatic pergola | pergola_command | used for controlling biclimatic pergola (closeSlats, openSlats, stop) |
| action group | execute_action | switch which reacts to ON command and triggers the predefined Tahoma action |
| onoff, light | switch | reacts to standard ON/OFF commands |
| dimmer light | light_intensity | sets/gets intensity of the dimmer light or ON/OFF |
| smoke sensor, occupancy sensor, contact sensor, water sensor & rain sensor | contact | normal value is CLOSE, changes to OPEN when detection triggered |
| smoke sensor, occupancy sensor, contact sensor & water sensor | sensor_defect | indicates the health of the sensor (dead, lowBatter, maintenanceRequired, noDefect) |
| smoke sensor | radio_battery | maintenance radio part battery state (low, normal) |
| smoke sensor | sensor_battery | maintenance sensor part battery state (absence, low, normal) |
| smoke sensor | short_check | triggering the smoke sensor's short check |
| smoke sensor | long_check | triggering the smoke sensor's long check |
| light sensor | luminance | light luminance value in luxes |
| electricity sensor | energy_consumption | energy consumption value in watts |
| humidity sensor | humidity | current relative humidity |
| dock | battery_status | indicates running on battery (yes/no) |
| dock | battery_level | remaining battery percentage |
| dock | siren_status | used for controlling and getting siren state (on, off, cyclic) |
| dock | short_beep | testing of dock's siren - short beep |
| dock | long_beep | testing of dock's siren - long beep |
| siren | battery | battery level full/low/normal/verylow |
| siren | onoff | controlling siren status ON/OFF |
| siren | memorized_volume | setting memorized volume (normal/highest) |
| pod | cyclic_button | pod cyclic button state |
| pod | battery_status | pod battery status state |
| pod | lighting_led_pod_mode | lighting LED pod mod state |
| interior alarm | alarm_command | used for sending commands to Somfy alarm device |
| interior alarm | intrusion_control | used for alarm external intrusion controlling |
| interior alarm, myfox alarm | alarm_state | state of the Somfy alarm |
| interior alarm | target_alarm_state | target state of the Somfy alarm |
| interior alarm, myfox alarm | intrusion_state | intrusion state of the Somfy alarm |
| external alarm | active_zones_state | state of external alarm active zones |
| door lock | lock | switch representing unlocked/locked state |
| door lock | open | switch representing open/close state |
| on/off heating system | target_heating_level | target heating level (off, eco, comfort, frostprotection) |
| heating system | current_temperature | current temperature of the heating system |
| heating system | current_state | current state of the heating system |
| heating system, valve heating system, thermostat | target_temperature | target temperature of the heating system |
| heating system, valve heating system, thermostat | battery_level | battery level of the heating system |
| valve heating system, thermostat | derogation_heating_mode | derogation heating mode of the thermostat (away, freeze, manual, ...) |
| valve heating system, thermostat | derogated_target_temperature | target temperature of the heating system |
| valve heating system | current_heating_mode | current heating mode of the thermostatic valve |
| valve heating system | open_closed_valve | current open/closed state of the thermostatic valve |
| valve heating system | operating mode | operating mode of the thermostatic valve |
| thermostat | heating_mode | standard heating mode of the thermostat (away, freeze, manual, ...) |
| thermostat | derogation_activation | derogation activation state (inactive, active) |
| exterior heating system | heating_level | heating level of the exterior heating system or ON/OFF |
| temperature sensor | temperature | temperature reported by the sensor |
| myfox camera, myfox alarm | cloud_status | cloud connection status |
| myfox camera | shutter | controlling of the camera shutter |
| myfox alarm | myfox_alarm_command | used for sending commands to Somfy Myfox alarm device |
| waterheatersystem | middlewater_temperature | Number:Temperature indicating the temperature of the water at the middle of the heater |
| waterheatersystem | boost_mode | Switch allowing to enable or disable the booster. When switching to ON, by default, the Boost duration will be set for 1 day. |
| waterheatersystem | away_mode | Defines if away mode is On or Off (no water heating) |
| waterheatersystem | away_mode_duration | Defines if away mode the duration in days. |
| waterheatersystem | boost_mode_duration | The duration of the Boost mode in days. Valid from 1 to 7. |
| waterheatersystem | power_heatpump | Current consumption/power of the heatpump in Watts. |
| waterheatersystem | power_heatelec | Current consumption/power of the electric resistance in Watts. |
| waterheatersystem | showers | Virtual channel, representing the number of desired showers - between 3 to 5. It actually switches the desired temperature to 50.0, 54.5 or 62.0 Celcius degrees. Please note that in ECO mode, only 3 and 4 showers are allowed. |
| waterheatersystem | heat_pump_operating_time | Number of hours the heatpump has been operating |
| waterheatersystem | electric_booster_operating_time | number of hours the electric booster has been operating. |
| waterheatersystem | mode | The current mode of the boiler. Can be: autoMode / manualEcoInactive / manualEcoActive |
| waterheatersystem | target_temperature | Water target temperature in degrees. Read only. Temperature desired is managed through mode and showers channels. |
| hitachi (yutaki) air to water heating zone, dhw, main component | alarm_number | error number in case of malfunction |
| hitachi (yutaki) air to water heating zone | circuit_control | controls the air-to-water-component (Run, Stop) |
| hitachi (yutaki) air to water heating zone | circuit_status | actual state of the air-to-water-component (Run, Stop) |
| hitachi (yutaki) air to water heating zone | holiday_mode | switch to activate the holiday mode |
| hitachi (yutaki) air to water heating zone | yutaki_mode | actual mode of the heat pump (Eco, Comfort) |
| hitachi (yutaki) air to water heating zone | yutaki_target_mode | sets the mode of the heat pump (Eco, Comfort) |
| hitachi (yutaki) air to water heating zone | zone_mode | sets the zone mode (Auto, Manual) |
| hitachi (yutaki) domestic hot water | anti_legionella | controls the anti legionella mode (Run, Stop) |
| hitachi (yutaki) domestic hot water | anti_legionella_temp | controls the anti legionella temperature |
| hitachi (yutaki) domestic hot water | target_boost_mode | controls the boost mode (No request, Enabled, Disabled) |
| hitachi (yutaki) domestic hot water | boost_mode | boost mode status (Enabled, Disabled) |
| hitachi (yutaki) domestic hot water | dhw | controls the hot water tank (Run, Stop) |
| hitachi (yutaki) domestic hot water | dhw_mode | controls the dhw mode (Standard, High demand) |
| hitachi (yutaki) domestic hot water | dhw_setting_temp | controls the target temperature for hot water |
| hitachi (yutaki) domestic hot water | dhw_temp | current temperature of hot water |
| hitachi (yutaki) air to water main component | auto_manu_mode | controls auto/manual mode (Auto, Manual) |
| hitachi (yutaki) air to water main component | block_menu_control | controls the block menu (No, Block) |
| hitachi (yutaki) air to water main component | comm_alarm_bit_status | alarm bit status (No, Yes) |
| hitachi (yutaki) air to water main component | compressor_running_current | stage of the current compressor running (0, 0.1, 0.2, 0.3, 0.4) |
| hitachi (yutaki) air to water main component | eco_mode_offset | offset for the ECO-Mode |
| hitachi (yutaki) air to water main component | eco_mode_target_offset | controls the offset for the ECO-Mode (0-10 degrees) |
| hitachi (yutaki) air to water main component | liquid_temp | current liquid temperature |
| hitachi (yutaki) air to water main component | liquid_temp_thmi | current liquid temperature THMI |
| hitachi (yutaki) air to water main component | operation | current operation state (Alarm, Off, Heat/Cool thermo on, Heat/Cool thermo off, DHW off, Heat/Cool demand off, Swp off) |
| hitachi (yutaki) air to water main component | outdoor_temp | current outdoor temperature |
| hitachi (yutaki) air to water main component | space_mode | controls space mode (Eco, Comfort) |
| hitachi (yutaki) air to water main component | unit_control | controls unit (Run, Stop) |
| hitachi (yutaki) air to water main component | unit_mode_control | controls unit mode (Heat, Cool) |
| hitachi (yutaki) air to water main component | unit_mode_status | unit mode state (Heat, Cool) |
| hitachi (yutaki) air to water main component | water_inlet_temp | current water inlet temperature |
| hitachi (yutaki) air to water main component | water_outlet_temp | current water outlet temperature |
| hitachi (yutaki) air to water main component | water_outlet_hp_temp | current water outlet hp temperature |
| hitachi (yutaki) air to water main component | water_temp_setting | target heating water temperature |
| hitachi (yutaki) air to water main component | yutaki_operating_mode | yutaki operating mode (Auto, Holidays, Normal, Timer) |
| Thing | Channel | Note |
|------------------------------------------------------------------------------------|---------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| bridge | N.A | bridge does not expose any channel |
| gateway | status | status of your gateway |
| gateway | scenarios | used to run the scenarios defined in the cloud portal |
| gate | gate_command | used for controlling your gate (open, close, stop, pedestrian) |
| gate | gate_state | get state of your gate (open, closed, pedestrian) |
| gate | gate_position | get position (0-100%) of your gate (where supported) |
| roller shutter, shutter, screen, ven. blind, garage door, awning, pergola, curtain | control | device controller which reacts to commands UP/DOWN/ON/OFF/OPEN/CLOSE/MY/STOP + closure 0-100 |
| window | control | device controller which reacts to commands UP/DOWN/ON/OFF/OPEN/CLOSE/STOP + closure 0-100 |
| silent roller shutter | silent_control | similar to control channel but in silent mode |
| venetian blind, adjustable slats roller shutter, bioclimatic pergola | orientation | percentual orientation of the blind's slats, it can have value 0-100. For IO Homecontrol devices only (non RTS) |
| venetian blind, adjustable slats roller shutter | closure_orientation | percentual closure and orientation of the blind's slats, it can have value 0-100. For IO Homecontrol devices only (non RTS) |
| adjustable slats roller shutter | rocker | used for setting the rocker position of the roller shutter, the only position allowing the slats control |
| bioclimatic pergola | slats | slats state (open/closed) |
| bioclimatic pergola | pergola_command | used for controlling biclimatic pergola (closeSlats, openSlats, stop) |
| action group | execute_action | switch which reacts to ON command and triggers the predefined Tahoma action |
| onoff, light | switch | reacts to standard ON/OFF commands |
| dimmer light | light_intensity | sets/gets intensity of the dimmer light or ON/OFF |
| smoke sensor, occupancy sensor, contact sensor, water sensor & rain sensor | contact | normal value is CLOSE, changes to OPEN when detection triggered |
| smoke sensor, occupancy sensor, contact sensor & water sensor | sensor_defect | indicates the health of the sensor (dead, lowBatter, maintenanceRequired, noDefect) |
| smoke sensor | radio_battery | maintenance radio part battery state (low, normal) |
| smoke sensor | sensor_battery | maintenance sensor part battery state (absence, low, normal) |
| smoke sensor | short_check | triggering the smoke sensor's short check |
| smoke sensor | long_check | triggering the smoke sensor's long check |
| light sensor | luminance | light luminance value in luxes |
| electricity sensor | energy_consumption | energy consumption value in watts |
| humidity sensor | humidity | current relative humidity |
| dock | battery_status | indicates running on battery (yes/no) |
| dock | battery_level | remaining battery percentage |
| dock | siren_status | used for controlling and getting siren state (on, off, cyclic) |
| dock | short_beep | testing of dock's siren - short beep |
| dock | long_beep | testing of dock's siren - long beep |
| siren | battery | battery level full/low/normal/verylow |
| siren | onoff | controlling siren status ON/OFF |
| siren | memorized_volume | setting memorized volume (normal/highest) |
| pod | cyclic_button | pod cyclic button state |
| pod | battery_status | pod battery status state |
| pod | lighting_led_pod_mode | lighting LED pod mod state |
| interior alarm | alarm_command | used for sending commands to Somfy alarm device |
| interior alarm | intrusion_control | used for alarm external intrusion controlling |
| interior alarm, myfox alarm | alarm_state | state of the Somfy alarm |
| interior alarm | target_alarm_state | target state of the Somfy alarm |
| interior alarm, myfox alarm | intrusion_state | intrusion state of the Somfy alarm |
| external alarm | active_zones_state | state of external alarm active zones |
| door lock | lock | switch representing unlocked/locked state |
| door lock | open | switch representing open/close state |
| on/off heating system | target_heating_level | target heating level (off, eco, comfort, frostprotection) |
| heating system | current_temperature | current temperature of the heating system |
| heating system | current_state | current state of the heating system |
| heating system, valve heating system, thermostat | target_temperature | target temperature of the heating system |
| heating system, valve heating system, thermostat | battery_level | battery level of the heating system |
| valve heating system, thermostat | derogation_heating_mode | derogation heating mode of the thermostat (away, freeze, manual, ...) |
| valve heating system, thermostat | derogated_target_temperature | target temperature of the heating system |
| valve heating system | current_heating_mode | current heating mode of the thermostatic valve |
| valve heating system | open_closed_valve | current open/closed state of the thermostatic valve |
| valve heating system | operating mode | operating mode of the thermostatic valve |
| thermostat | heating_mode | standard heating mode of the thermostat (away, freeze, manual, ...) |
| thermostat | derogation_activation | derogation activation state (inactive, active) |
| exterior heating system | heating_level | heating level of the exterior heating system or ON/OFF |
| temperature sensor | temperature | temperature reported by the sensor |
| myfox camera, myfox alarm | cloud_status | cloud connection status |
| myfox camera | shutter | controlling of the camera shutter |
| myfox alarm | myfox_alarm_command | used for sending commands to Somfy Myfox alarm device |
| waterheatersystem | middlewater_temperature | Number:Temperature indicating the temperature of the water at the middle of the heater |
| waterheatersystem | boost_mode | Switch allowing to enable or disable the booster. When switching to ON, by default, the Boost duration will be set for 1 day. |
| waterheatersystem | away_mode | Defines if away mode is On or Off (no water heating) |
| waterheatersystem | away_mode_duration | Defines if away mode the duration in days. |
| waterheatersystem | boost_mode_duration | The duration of the Boost mode in days. Valid from 1 to 7. |
| waterheatersystem | power_heatpump | Current consumption/power of the heatpump in Watts. |
| waterheatersystem | power_heatelec | Current consumption/power of the electric resistance in Watts. |
| waterheatersystem | showers | Virtual channel, representing the number of desired showers - between 3 to 5. It actually switches the desired temperature to 50.0, 54.5 or 62.0 Celcius degrees. Please note that in ECO mode, only 3 and 4 showers are allowed. |
| waterheatersystem | heat_pump_operating_time | Number of hours the heatpump has been operating |
| waterheatersystem | electric_booster_operating_time | number of hours the electric booster has been operating. |
| waterheatersystem | mode | The current mode of the boiler. Can be: autoMode / manualEcoInactive / manualEcoActive |
| waterheatersystem | target_temperature | Water target temperature in degrees. Read only. Temperature desired is managed through mode and showers channels. |
| hitachi (yutaki) air to water heating zone, dhw, main component | alarm_number | error number in case of malfunction |
| hitachi (yutaki) air to water heating zone | circuit_control | controls the air-to-water-component (Run, Stop) |
| hitachi (yutaki) air to water heating zone | circuit_status | actual state of the air-to-water-component (Run, Stop) |
| hitachi (yutaki) air to water heating zone | holiday_mode | switch to activate the holiday mode |
| hitachi (yutaki) air to water heating zone | yutaki_mode | actual mode of the heat pump (Eco, Comfort) |
| hitachi (yutaki) air to water heating zone | yutaki_target_mode | sets the mode of the heat pump (Eco, Comfort) |
| hitachi (yutaki) air to water heating zone | zone_mode | sets the zone mode (Auto, Manual) |
| hitachi (yutaki) domestic hot water | anti_legionella | controls the anti legionella mode (Run, Stop) |
| hitachi (yutaki) domestic hot water | anti_legionella_temp | controls the anti legionella temperature |
| hitachi (yutaki) domestic hot water | target_boost_mode | controls the boost mode (No request, Enabled, Disabled) |
| hitachi (yutaki) domestic hot water | boost_mode | boost mode status (Enabled, Disabled) |
| hitachi (yutaki) domestic hot water | dhw | controls the hot water tank (Run, Stop) |
| hitachi (yutaki) domestic hot water | dhw_mode | controls the dhw mode (Standard, High demand) |
| hitachi (yutaki) domestic hot water | dhw_setting_temp | controls the target temperature for hot water |
| hitachi (yutaki) domestic hot water | dhw_temp | current temperature of hot water |
| hitachi (yutaki) air to water main component | auto_manu_mode | controls auto/manual mode (Auto, Manual) |
| hitachi (yutaki) air to water main component | block_menu_control | controls the block menu (No, Block) |
| hitachi (yutaki) air to water main component | comm_alarm_bit_status | alarm bit status (No, Yes) |
| hitachi (yutaki) air to water main component | compressor_running_current | stage of the current compressor running (0, 0.1, 0.2, 0.3, 0.4) |
| hitachi (yutaki) air to water main component | eco_mode_offset | offset for the ECO-Mode |
| hitachi (yutaki) air to water main component | eco_mode_target_offset | controls the offset for the ECO-Mode (0-10 degrees) |
| hitachi (yutaki) air to water main component | liquid_temp | current liquid temperature |
| hitachi (yutaki) air to water main component | liquid_temp_thmi | current liquid temperature THMI |
| hitachi (yutaki) air to water main component | operation | current operation state (Alarm, Off, Heat/Cool thermo on, Heat/Cool thermo off, DHW off, Heat/Cool demand off, Swp off) |
| hitachi (yutaki) air to water main component | outdoor_temp | current outdoor temperature |
| hitachi (yutaki) air to water main component | space_mode | controls space mode (Eco, Comfort) |
| hitachi (yutaki) air to water main component | unit_control | controls unit (Run, Stop) |
| hitachi (yutaki) air to water main component | unit_mode_control | controls unit mode (Heat, Cool) |
| hitachi (yutaki) air to water main component | unit_mode_status | unit mode state (Heat, Cool) |
| hitachi (yutaki) air to water main component | water_inlet_temp | current water inlet temperature |
| hitachi (yutaki) air to water main component | water_outlet_temp | current water outlet temperature |
| hitachi (yutaki) air to water main component | water_outlet_hp_temp | current water outlet hp temperature |
| hitachi (yutaki) air to water main component | water_temp_setting | target heating water temperature |
| hitachi (yutaki) air to water main component | yutaki_operating_mode | yutaki operating mode (Auto, Holidays, Normal, Timer) |
To run a scenario inside a rule for example, the ID of the scenario will be required.
You can list all the scenarios IDs with the following console command: `somfytahoma <bridgeUID> scenarios`.