[openwebnet] Add support for Alarm (WHO=5) (#13694)
* [openwebnet] first changes for Alarm support * [openwebnet] added first version Alarm handler * [openwebnet] added ownIdTest for Alarm * [openwebnet] added things def for Alarm and discovery for alarm zone * [openwebnet] refreshDevice * [openwebnet] fix text formatting * [openwebnet] fixes * [openwebnet] added other alarm channels * [openwebnet] Alarm: codestyle and null checks * [openwebnet] updated Alarm examples in README and some cleanup * [openwebnet] changed zone channel from armed to state, cleaned README Signed-off-by: Massimo Valla <mvcode00@gmail.com>
This commit is contained in:
@@ -43,11 +43,13 @@ The following Things and OpenWebNet `WHOs` are supported:
|
||||
| Gateway Management | `13` | `bus_gateway` | Any IP gateway supporting OpenWebNet protocol should work | Successfully tested: F452, F453, F453AV,F454, F455, MyHOMEServer1, MyHOME_Screen10, MyHOME_Screen3,5, MH201, MH202, MH200N. Some connection stability issues/gateway resets reported with MH202 |
|
||||
| Lighting | `1` | `bus_on_off_switch`, `bus_dimmer` | BUS switches and dimmers | Successfully tested: F411/2, F411/4, F411U2, F422, F429. Some discovery issues reported with F429 (DALI Dimmers) |
|
||||
| Automation | `2` | `bus_automation` | BUS roller shutters, with position feedback and auto-calibration | Successfully tested: LN4672M2 |
|
||||
| Temperature Control | `4` | `bus_thermo_zone`, `bus_thermo_sensor`, `bus_thermo_cu` | Thermo zones management and temperature sensors (probes). | Successfully tested: H/LN4691, HS4692, KG4691; thermo sensors: L/N/NT4577 + 3455; Central Units (4 or 99 zones) are not fully supported yet. See [Channels - Thermo](#configuring-thermo) for more details |
|
||||
| Auxiliary (AUX) | `9` | `bus_aux` | AUX commands | Successfully tested: AUX configured for bulgrar-alarm unit 3486. **Only sending AUX commands is supported** |
|
||||
| Basic, CEN & CEN+ Scenarios | `0`, `15`, `25` | `bus_scenario_control`, `bus_cen_scenario_control`, `bus_cenplus_scenario_control` | Basic and CEN/CEN+ Scenarios events and virtual activation | Successfully tested: CEN/CEN+ scenario control: HC/HD/HS/L/N/NT4680 and basic scenario modules F420/IR3456 + L4680 (WHO=0) |
|
||||
| Dry Contact and IR Interfaces | `25` | `bus_dry_contact_ir` | Dry Contacts and IR Interfaces | Successfully tested: contact interfaces F428 and 3477; IR sensors: HC/HD/HS/L/N/NT4610 |
|
||||
| Energy Management | `18` | `bus_energy_meter` | Energy Management | Successfully tested: F520, F521. Partially tested: F522, F523 |
|
||||
| Temperature Control | `4` | `bus_thermo_zone`, `bus_thermo_sensor`, `bus_thermo_cu` | Thermo zones management and temperature sensors (probes) | Successfully tested: H/LN4691, HS4692, KG4691; thermo sensors: L/N/NT4577 + 3455; Central Units (4 or 99 zones) are not fully supported yet. See [Channels - Thermo](#configuring-thermo) for more details |
|
||||
| Alarm | `5` | `bus_alarm_system`, `bus_alarm_zone` | BUS Alarm system and zones | Successfully tested: Burglar-alarm Unit 3486 |
|
||||
| Auxiliary (AUX) | `9` | `bus_aux` | AUX commands | Successfully tested: AUX configured for Burglar-alarm Unit 3486. **Only sending AUX commands is supported** |
|
||||
| Basic, CEN & CEN+ Scenarios | `0`, `15`, `25` | `bus_scenario_control`, `bus_cen_scenario_control`, `bus_cenplus_scenario_control` | Basic and CEN/CEN+ Scenarios events and virtual activation | Successfully tested: CEN/CEN+ scenario control: HC/HD/HS/L/N/NT4680 and basic scenario modules F420/IR3456 + L4680 (WHO=0) |
|
||||
| Dry Contact and IR Interfaces | `25` | `bus_dry_contact_ir` | Dry Contacts and IR Interfaces | Successfully tested: contact interfaces F428 and 3477; IR sensors: HC/HD/HS/L/N/NT4610 |
|
||||
| Energy Management | `18` | `bus_energy_meter` | Energy Management | Successfully tested: F520, F521. Partially tested: F522, F523 |
|
||||
|
||||
|
||||
### For ZigBee (Radio)
|
||||
|
||||
@@ -133,9 +135,10 @@ For any manually added device, you must configure:
|
||||
- scenario control module address `53` --> `where="53"`
|
||||
- CEN scenario A=`05`, PL=`12` --> `where="0512"`
|
||||
- CEN+ scenario `5`: add `2` before --> `where="25"`
|
||||
- Dry Contact or IR Interface `99`: add `3` before --> `where="399"`
|
||||
- Energy meter F520/F521 numbered `1`: add `5` before --> `where="51"`
|
||||
- Energy meter F522/F523 numbered `4` add `7` before and `#0` after --> `where="74#0"`
|
||||
- dry Contact or IR Interface `99`: add `3` before --> `where="399"`
|
||||
- energy meter F520/F521 numbered `1`: add `5` before --> `where="51"`
|
||||
- energy meter F522/F523 numbered `4`: add `7` before and `#0` after --> `where="74#0"`
|
||||
- alarm zone `2` --> `where="2"`
|
||||
- example for ZigBee devices: `where=765432101#9`. The ID of the device (ADDR part) is usually written in hexadecimal on the device itself, for example `ID 0074CBB1`: convert to decimal (`7654321`) and add `01#9` at the end to obtain `where=765432101#9`. For 2-unit switch devices (`zb_on_off_switch2u`), last part should be `00#9`.
|
||||
|
||||
|
||||
@@ -157,83 +160,97 @@ Temperature sensors can be configured defining a `bus_thermo_sensor` Thing with
|
||||
|
||||
The (optional) Central Unit can be configured defining a `bus_themo_cu` Thing with the `where` configuration parameter (`OpenWebNet Address`) set to `where="0"`.
|
||||
|
||||
##### Central Unit integration missing points
|
||||
##### Thermo Central Unit integration missing points
|
||||
|
||||
- Read setPoint temperature and current mode
|
||||
- Holiday activation command (all zones)
|
||||
- Discovery
|
||||
|
||||
#### Configuring Auxiliary (AUX)
|
||||
#### Configuring Alarm and Auxiliary (AUX)
|
||||
|
||||
**NOTE** Receiving AUX messages originating from the BUS is not supported yet, only sending messages to the BUS is supported.
|
||||
**NOTE 1** Receiving AUX messages originating from the BUS is not supported yet, only sending messages to the BUS is supported
|
||||
|
||||
**NOTE 2** Alarm messages on BUS are not sent by MyHOMEServer1, therfore this gateway cannot be used to integrate the BTicino Alarm system
|
||||
|
||||
BUS Auxiliary commands (WHO=9) can be used to send on the BUS commands to control, for example, external devices or a BTicino Alarm system.
|
||||
|
||||
The BTicino Alarm system **cannot** be controlled directly via the OpenWebNet protocol: the only possibility is to use AUX commands and configure your Alarm Control Panel (Automations section) to execute some commands (e.g. Activate alarm) when it receives a particular AUX OpenWebNet command.
|
||||
Alarm Control Automations allow you to run an OpenWebNet command when a particular event occurs; in this case, the events are changes of state of the AUX device (WHO=9) and the command to be performed is a burglar alarm command (WHO=5).
|
||||
The BTicino Alarm system **cannot** be controlled directly via the OpenWebNet protocol: the only possibility is to use AUX commands and configure your Burglar-alarm Unit (`Automations` section) to execute some commands (e.g. Arm alarm) when it receives a particular AUX OpenWebNet command.
|
||||
Alarm Automations allow you to run an OpenWebNet command when a particular event occurs; in this case, the events are changes of state of the AUX device (WHO=9) and the command to be performed is a burglar alarm command (WHO=5).
|
||||
|
||||
To configure Alarm Control Automations go to the menu:
|
||||
To configure Alarm Automations go to the menu:
|
||||
|
||||
Antitheft -> Automations
|
||||
|
||||
##### Example configuration Automation 1: when AUX-1 goes OFF, then DISENGAGE all Zones
|
||||
##### Example configuration Automation 1: when AUX-4 goes ON, then ARM all zones
|
||||
|
||||
With this configuration when AUX `where=1` goes OFF, the Alarm will execute the automation and send command `*5*9##` to DISENGAGE all zones.
|
||||
With this configuration when AUX `where=4` goes ON, the Alarm will execute the automation and send command `*5*8##` to ARM all zones:
|
||||
|
||||
Name: Disengage all zones
|
||||
Event: command OPEN = *9*0*1##
|
||||
OPEN command to execute: *5*9##
|
||||
|
||||
##### Example configuration Automation 2: when AUX-2 goes ON, then ENGAGE active Zones
|
||||
|
||||
Name: Engage active zones
|
||||
Event: command OPEN = *9*1*2##
|
||||
Name: Arm all zones
|
||||
Event: command OPEN = *9*1*4##
|
||||
OPEN command to execute: *5*8##
|
||||
|
||||
##### Example configuration Automation 3: when AUX-4 goes ON, then ENGAGE Zones 1, 2, 3, 4
|
||||
##### Example configuration Automation 2: when AUX-4 goes OFF, then DISARM all zones
|
||||
|
||||
Name: Engage zones 1-4
|
||||
Event: command OPEN = *9*1*4##
|
||||
OPEN command to execute: *5*8#1234##
|
||||
Name: Disarm all zones
|
||||
Event: command OPEN = *9*0*4##
|
||||
OPEN command to execute: *5*9##
|
||||
|
||||
##### Example configuration Automation 3: when AUX-5 goes ON, then ARM zones 1, 3, 4
|
||||
|
||||
Name: Arm zones 1 3 4
|
||||
Event: command OPEN = *9*1*5##
|
||||
OPEN command to execute: *5*8#134##
|
||||
|
||||
## Channels
|
||||
|
||||
### Lighting, Automation, Power meter, Basic/CEN/CEN+ Scenario Events and Dry Contact / IR Interfaces channels
|
||||
### Lighting, Automation, Basic/CEN/CEN+ Scenario Events, Dry Contact / IR Interfaces, Power and Aux channels
|
||||
|
||||
| Channel Type ID (channel ID) | Applies to Thing Type IDs | Item Type | Description | Read/Write |
|
||||
|-----------------------------------------|---------------------------------------------------------------|---------------|-------------------------------------------------------------------------------------------------------------------------------------------------|:-----------:|
|
||||
| `switch` or `switch_01`/`02` for ZigBee | `bus_on_off_switch`, `zb_on_off_switch`, `zb_on_off_switch2u` | Switch | To switch the device `ON` and `OFF` | R/W |
|
||||
| `brightness` | `bus_dimmer`, `zb_dimmer` | Dimmer | To adjust the brightness value (Percent, `ON`, `OFF`) | R/W |
|
||||
| `shutter` | `bus_automation` | Rollershutter | To activate roller shutters (`UP`, `DOWN`, `STOP`, Percent - [see Shutter position](#shutter-position)) | R/W |
|
||||
| `button#X` | `bus_cen_scenario_control`, `bus_cenplus_scenario_control` | String | Trigger channel for CEN/CEN+ scenario events [see possible values](#scenario-channels) | R (TRIGGER) |
|
||||
| `sensor` | `bus_dry_contact_ir` | Switch | Indicates if a Dry Contact Interface is `ON`/`OFF`, or if a IR Sensor is detecting movement (`ON`), or not (`OFF`) | R |
|
||||
| `power` | `bus_energy_meter` | Number:Power | The current active power usage from Energy Meter | R |
|
||||
| Channel Type ID (channel ID) | Applies to Thing Type IDs | Item Type | Description | Read/Write |
|
||||
|-----------------------------------------|---------------------------------------------------------------|---------------|-----------------------------------------------------------------------------------------------------------------------|:-----------:|
|
||||
| `switch` or `switch_01`/`02` for ZigBee | `bus_on_off_switch`, `zb_on_off_switch`, `zb_on_off_switch2u` | Switch | To switch the device `ON` and `OFF` | R/W |
|
||||
| `brightness` | `bus_dimmer`, `zb_dimmer` | Dimmer | To adjust the brightness value (Percent, `ON`, `OFF`) | R/W |
|
||||
| `shutter` | `bus_automation` | Rollershutter | To activate roller shutters (`UP`, `DOWN`, `STOP`, Percent - [see Shutter position](#shutter-position)) | R/W |
|
||||
| `scenario` | `bus_scenario_control` | String | Trigger channel for Basic scenario events [see possible values](#scenario-channels) | R (TRIGGER) |
|
||||
| `button#X` | `bus_cen_scenario_control`, `bus_cenplus_scenario_control` | String | Trigger channel for CEN/CEN+ scenario events [see possible values](#scenario-channels) | R (TRIGGER) |
|
||||
| `sensor` | `bus_dry_contact_ir` | Switch | Indicates if a Dry Contact Interface is `ON`/`OFF`, or if a IR Sensor is detecting movement (`ON`), or not (`OFF`) | R |
|
||||
| `power` | `bus_energy_meter` | Number:Power | The current active power usage from Energy Meter | R |
|
||||
| `aux` | `bus_aux` | String | Possible commands: `ON`, `OFF`, `TOGGLE`, `STOP`, `UP`, `DOWN`, `ENABLED`, `DISABLED`, `RESET_GEN`, `RESET_BI`, `RESET_TRI`. Only `ON` and `OFF` are supported for now | R/W |
|
||||
| `scenario` | `bus_scenario_control` | String | Trigger channel for Basic scenario events [see possible values](#scenario-channels) | R (TRIGGER) |
|
||||
|
||||
|
||||
### Alarm channels
|
||||
|
||||
| Channel Type ID (channel ID) | Applies to Thing Type IDs | Item Type | Description | Read/Write |
|
||||
|------------------------------|----------------------------------------|-------------|-----------------------------------------------------------------------|:-----------:|
|
||||
| `state` | `bus_alarm_system`, `bus_alarm_zone` | Switch | Alarm system or zone is active (`ON`) or inactive (`OFF`) | R |
|
||||
| `network` | `bus_alarm_system` | Switch | Alarm system network state (`ON` = network ok, `OFF` = no network) | R |
|
||||
| `battery` | `bus_alarm_system` | String | Alarm system battery state (`OK`, `FAULT`, `UNLOADED`) | R |
|
||||
| `armed` | `bus_alarm_system` | Switch | Alarm system is armed (`ON`) or disarmed (`OFF`) | R |
|
||||
| `alarm` | `bus_alarm_zone` | String | Current alarm for the zone (`SILENT`, `INTRUSION`, `TAMPERING`, `ANTI_PANIC`) | R |
|
||||
|
||||
|
||||
### Thermo channels
|
||||
|
||||
**NOTE** Channels marked with Advanced=Y can be shown from Thing configuration > Channels tab > check `Show advanced`.
|
||||
**NOTE** Channels marked in the table with `Advanced = Y` can be shown on the UI from Thing configuration > Channels tab > check `Show advanced`.
|
||||
|
||||
| Channel Type ID (channel ID) | Applies to Thing Type IDs | Item Type | Description | Read/Write | Advanced |
|
||||
| ---------------------------- | -------------------------------------- | ------------------ | --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | :--------: | :------: |
|
||||
| `temperature` | `bus_thermo_zone`, `bus_thermo_sensor` | Number:Temperature | The zone currently sensed temperature | R | N |
|
||||
| `setpointTemperature` | `bus_thermo_zone`, `bus_thermo_cu` | Number:Temperature | The zone or Central Unit setpoint temperature | R/W | N |
|
||||
| `function` | `bus_thermo_zone`, `bus_thermo_cu` | String | The zone set thermo function (`COOLING`, `HEATING`, `GENERIC`) or the Central Unit thermo function (`COOLING`, `HEATING`) | R/W | N |
|
||||
| `mode` | `bus_thermo_zone`, `bus_thermo_cu` | String | The zone set mode (`MANUAL`, `PROTECTION`, `OFF`) or the Central Unit set mode ( `MANUAL`, `PROTECTION`, `OFF`, `WEEKLY`, `SCENARIO`) | R/W | N |
|
||||
| `speedFanCoil` | `bus_thermo_zone` | String | The zone fancoil speed: `AUTO`, `SPEED_1`, `SPEED_2`, `SPEED_3` | R/W | N |
|
||||
| Channel Type ID (channel ID) | Applies to Thing Type IDs | Item Type | Description | Read/Write | Advanced |
|
||||
| ---------------------------- | -------------------------------------- | ------------------ | ------------------------------------------------------------------------------------------------------------------------------------- | :--------: | :------: |
|
||||
| `temperature` | `bus_thermo_zone`, `bus_thermo_sensor` | Number:Temperature | The zone currently sensed temperature | R | N |
|
||||
| `setpointTemperature` | `bus_thermo_zone`, `bus_thermo_cu` | Number:Temperature | The zone or Central Unit setpoint temperature | R/W | N |
|
||||
| `function` | `bus_thermo_zone`, `bus_thermo_cu` | String | The zone set thermo function (`COOLING`, `HEATING`, `GENERIC`) or the Central Unit thermo function (`COOLING`, `HEATING`) | R/W | N |
|
||||
| `mode` | `bus_thermo_zone`, `bus_thermo_cu` | String | The zone set mode (`MANUAL`, `PROTECTION`, `OFF`) or the Central Unit set mode ( `MANUAL`, `PROTECTION`, `OFF`, `WEEKLY`, `SCENARIO`) | R/W | N |
|
||||
| `speedFanCoil` | `bus_thermo_zone` | String | The zone fancoil speed: `AUTO`, `SPEED_1`, `SPEED_2`, `SPEED_3` | R/W | N |
|
||||
| `actuators` | `bus_thermo_zone` | String | The zone actuator(s) status: `OFF`, `ON`, `OPENED`, `CLOSED` , `STOP`, `OFF_FAN_COIL`, `ON_SPEED_1`, `ON_SPEED_2`, `ON_SPEED_3`, `OFF_SPEED_1`, `OFF_SPEED_2`, `OFF_SPEED_3` | R | Y |
|
||||
| `heatingValves` | `bus_thermo_zone` | String | The zone heating valve(s) status: `OFF`, `ON`, `OPENED`, `CLOSED` , `STOP`, `OFF_FAN_COIL`, `ON_SPEED_1`, `ON_SPEED_2`, `ON_SPEED_3`, `OFF_SPEED_1`, `OFF_SPEED_2`, `OFF_SPEED_3` | R | Y |
|
||||
| `conditioningValves` | `bus_thermo_zone` | String | The zone conditioning valve(s) status: `OFF`, `ON`, `OPENED`, `CLOSED` , `STOP`, `OFF_FAN_COIL`, `ON_SPEED_1`, `ON_SPEED_2`, `ON_SPEED_3`, `OFF_SPEED_1`, `OFF_SPEED_2`, `OFF_SPEED_3` | R | Y |
|
||||
| `localOffset` | `bus_thermo_zone` | String | The zone local offset status: `OFF`, `PROTECTION`, `MINUS_3`, `MINUS_2` , `MINUS_1`, `NORMAL`, `PLUS_1`, `PLUS_2`, `PLUS_3` | R | Y |
|
||||
| `remoteControl` | `bus_thermo_cu` | String | The Central Unit Remote Control status: `ENABLED`, `DISABLED` | R | Y |
|
||||
| `batteryStatus` | `bus_thermo_cu` | String | The Central Unit Battery status: `OK`, `KO` | R | Y |
|
||||
| `weeklyProgram` | `bus_thermo_cu` | Number | The program number (`1`, `2`, `3`) when Central Unit mode is `WEEKLY` | R/W | N |
|
||||
| `scenarioProgram` | `bus_thermo_cu` | Number | The program number (`1`, `2`, ... , `16`) when Central Unit mode is `SCENARIO` | R/W | N |
|
||||
| `failureDiscovered` | `bus_thermo_cu` | Switch | Indicates if a Failure was discovered by the Central Unit: `ON`, `OFF` | R | Y |
|
||||
| `atLeastOneProbeOff` | `bus_thermo_cu` | Switch | Indicates if at least one probe is in OFF mode: `ON`, `OFF` | R | Y |
|
||||
| `atLeastOneProbeProtection` | `bus_thermo_cu` | Switch | Indicates if at least one probe is in PROTECTION mode: `ON`, `OFF` | R | Y |
|
||||
| `atLeastOneProbeManual` | `bus_thermo_cu` | Switch | Indicates if at least one probe is in MANUAL mode: `ON`, `OFF` | R | Y |
|
||||
| `heatingValves` | `bus_thermo_zone` | String | The zone heating valve(s) status: `OFF`, `ON`, `OPENED`, `CLOSED` , `STOP`, `OFF_FAN_COIL`, `ON_SPEED_1`, `ON_SPEED_2`, `ON_SPEED_3`, `OFF_SPEED_1`, `OFF_SPEED_2`, `OFF_SPEED_3` | R | Y |
|
||||
| `conditioningValves` | `bus_thermo_zone` | String | The zone conditioning valve(s) status: `OFF`, `ON`, `OPENED`, `CLOSED` , `STOP`, `OFF_FAN_COIL`, `ON_SPEED_1`, `ON_SPEED_2`, `ON_SPEED_3`, `OFF_SPEED_1`, `OFF_SPEED_2`, `OFF_SPEED_3` | R | Y |
|
||||
| `localOffset` | `bus_thermo_zone` | String | The zone local offset status: `OFF`, `PROTECTION`, `MINUS_3`, `MINUS_2` , `MINUS_1`, `NORMAL`, `PLUS_1`, `PLUS_2`, `PLUS_3` | R | Y |
|
||||
| `remoteControl` | `bus_thermo_cu` | String | The Central Unit Remote Control status: `ENABLED`, `DISABLED` | R | Y |
|
||||
| `batteryStatus` | `bus_thermo_cu` | String | The Central Unit Battery status: `OK`, `KO` | R | Y |
|
||||
| `weeklyProgram` | `bus_thermo_cu` | Number | The program number (`1`, `2`, `3`) when Central Unit mode is `WEEKLY` | R/W | N |
|
||||
| `scenarioProgram` | `bus_thermo_cu` | Number | The program number (`1`, `2`, ... , `16`) when Central Unit mode is `SCENARIO` | R/W | N |
|
||||
| `failureDiscovered` | `bus_thermo_cu` | Switch | Indicates if a Failure was discovered by the Central Unit: `ON`, `OFF` | R | Y |
|
||||
| `atLeastOneProbeOff` | `bus_thermo_cu` | Switch | Indicates if at least one probe is in OFF mode: `ON`, `OFF` | R | Y |
|
||||
| `atLeastOneProbeProtection` | `bus_thermo_cu` | Switch | Indicates if at least one probe is in PROTECTION mode: `ON`, `OFF` | R | Y |
|
||||
| `atLeastOneProbeManual` | `bus_thermo_cu` | Switch | Indicates if at least one probe is in MANUAL mode: `ON`, `OFF` | R | Y |
|
||||
|
||||
### Notes on channels
|
||||
|
||||
@@ -282,7 +299,7 @@ In order to activate one of them you have to use two different channels:
|
||||
- with `mode` you can set the mode (`WEEKLY` or `SCENARIO`)
|
||||
- with `weeklyProgram` (if `WEEKLY` was set) or with `scenarioProgram` (if `SCENARIO` was set) you can set the program number
|
||||
|
||||
Example: if you want to activate SCENARIO #9 on the thermo Central Unit you have to set `mode` = `SCENARIO` and `scenarioProgram` = `9`.
|
||||
Example: if you want to activate SCENARIO number 9 on the thermo Central Unit you have to set `mode` = `SCENARIO` and `scenarioProgram` = `9`.
|
||||
|
||||
## Full Example
|
||||
|
||||
@@ -309,7 +326,10 @@ Bridge openwebnet:bus_gateway:mybridge "MyHOMEServer1" [ host="192.168.1.35", pa
|
||||
bus_cenplus_scenario_control LR_CENplus_scenario "Living Room CEN+" [ where="212", buttons="1,5,18" ]
|
||||
bus_dry_contact_ir LR_IR_sensor "Living Room IR Sensor" [ where="399" ]
|
||||
|
||||
bus_aux Alarm_activation "Alarm activation" [ where="4" ]
|
||||
bus_aux Alarm_Control "Alarm control" [ where="4" ]
|
||||
|
||||
bus_alarm_system Alarm_Sys "Alarm System" [ where="0" ]
|
||||
bus_alarm_zone Alarm_Zone_3 "Alarm Zone 3" [ where="3" ]
|
||||
}
|
||||
```
|
||||
|
||||
@@ -328,32 +348,32 @@ Bridge openwebnet:zb_gateway:myZBgateway [ serialPort="COM3" ] {
|
||||
|
||||
Example items linked to BUS devices:
|
||||
|
||||
NOTE: lights, blinds and zones (thermostat) can be handled from personal assistants (Google Home, Alexa). In the following example `Google Assistant` (`ga="..."`) and `HomeKit` (`homekit="..."`) were configured according to the [Google official documentation](https://www.openhab.org/docs/ecosystem/google-assistant) and [HomeKit official documentation](https://www.openhab.org/addons/integrations/homekit/)
|
||||
NOTE: lights, blinds and zones (thermostat) can be handled from personal assistants (Google Home, Alexa). In the following example `Google Assistant` (`ga="..."`) and `HomeKit` (`homekit="..."`) were configured according to the [Google official documentation](https://www.openhab.org/docs/ecosystem/google-assistant) and [HomeKit official documentation](https://www.openhab.org/addons/integrations/homekit/)
|
||||
|
||||
```
|
||||
Switch iLR_switch "Light" (gLivingRoom) { channel="openwebnet:bus_on_off_switch:mybridge:LR_switch:switch", ga="Light", homekit="Lighting" }
|
||||
Dimmer iLR_dimmer "Dimmer [%.0f %%]" (gLivingRoom) { channel="openwebnet:bus_dimmer:mybridge:LR_dimmer:brightness", ga="Light", homekit="Lighting" }
|
||||
Switch iLR_switch "Light" (gLivingRoom) { channel="openwebnet:bus_on_off_switch:mybridge:LR_switch:switch", ga="Light", homekit="Lighting" }
|
||||
Dimmer iLR_dimmer "Dimmer [%.0f %%]" (gLivingRoom) { channel="openwebnet:bus_dimmer:mybridge:LR_dimmer:brightness", ga="Light", homekit="Lighting" }
|
||||
|
||||
Rollershutter iLR_shutter "Shutter [%.0f %%]" (gShutters, gLivingRoom) { channel="openwebnet:bus_automation:mybridge:LR_shutter:shutter", ga="Blinds", homekit = "Window" }
|
||||
Rollershutter iLR_shutter "Shutter [%.0f %%]" (gShutters, gLivingRoom) { channel="openwebnet:bus_automation:mybridge:LR_shutter:shutter", ga="Blinds", homekit = "Window" }
|
||||
|
||||
Number:Power iCENTRAL_Ta "Power [%.0f %unit%]" { channel="openwebnet:bus_energy_meter:mybridge:CENTRAL_Ta:power" }
|
||||
Number:Power iCENTRAL_Tb "Power [%.0f %unit%]" { channel="openwebnet:bus_energy_meter:mybridge:CENTRAL_Tb:power" }
|
||||
Number:Power iCENTRAL_Ta "Power [%.0f %unit%]" { channel="openwebnet:bus_energy_meter:mybridge:CENTRAL_Ta:power" }
|
||||
Number:Power iCENTRAL_Tb "Power [%.0f %unit%]" { channel="openwebnet:bus_energy_meter:mybridge:CENTRAL_Tb:power" }
|
||||
|
||||
// 99 zones central unit
|
||||
Group gCentralUnit "Central Unit"
|
||||
Number:Temperature iCU_3550_manualset "Temperature" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:setpointTemperature", ga="thermostatTemperatureSetpoint" }
|
||||
String iCU_3550_remote "Remote Control" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:remoteControl" }
|
||||
String iCU_3550_battery "Battery Status" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:batteryStatus" }
|
||||
String iCU_3550_mode "Mode" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:mode" }
|
||||
Number iCU_3550_wpn "Weekly Program" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:weeklyProgram" }
|
||||
Number iCU_3550_spn "Scenario Program" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:scenarioProgram" }
|
||||
String iCU_3550_func "Function" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:function" }
|
||||
Switch iCU_3550_at1off "At least one probe in OFF" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:atLeastOneProbeOff" }
|
||||
Switch iCU_3550_at1pro "At least one probe in PROTECTION" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:atLeastOneProbeProtection" }
|
||||
Switch iCU_3550_at1man "At least one probe in MANUAL" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:atLeastOneProbeManual" }
|
||||
Switch iCU_3550_failure "Failure discovered" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:failureDiscovered" }
|
||||
// 99 zones thermo central unit
|
||||
Group gCentralUnit "Thermo Central Unit"
|
||||
Number:Temperature iCU_3550_manualset "Temperature" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:setpointTemperature", ga="thermostatTemperatureSetpoint" }
|
||||
String iCU_3550_remote "Remote Control" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:remoteControl" }
|
||||
String iCU_3550_battery "Battery Status" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:batteryStatus" }
|
||||
String iCU_3550_mode "Mode" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:mode" }
|
||||
Number iCU_3550_wpn "Weekly Program" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:weeklyProgram" }
|
||||
Number iCU_3550_spn "Scenario Program" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:scenarioProgram" }
|
||||
String iCU_3550_func "Function" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:function" }
|
||||
Switch iCU_3550_at1off "At least one probe in OFF" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:atLeastOneProbeOff" }
|
||||
Switch iCU_3550_at1pro "At least one probe in PROTECTION" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:atLeastOneProbeProtection" }
|
||||
Switch iCU_3550_at1man "At least one probe in MANUAL" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:atLeastOneProbeManual" }
|
||||
Switch iCU_3550_failure "Failure discovered" (gCentralUnit) { channel="openwebnet:bus_thermo_cu:mybridge:CU_3550:failureDiscovered" }
|
||||
|
||||
Group gLivingRoomZone "Living Room Zone" { ga="Thermostat" [ modes="auto=GENERIC,heat=HEATING,cool=COOLING", thermostatTemperatureRange="7,35", useFahrenheit=false ] }
|
||||
Group gLivingRoomZone "Living Room Zone" { ga="Thermostat" [ modes="auto=GENERIC,heat=HEATING,cool=COOLING", thermostatTemperatureRange="7,35", useFahrenheit=false ] }
|
||||
Number:Temperature iLR_zone_temp "Temperature [%.1f %unit%]" (gLivingRoomZone) { channel="openwebnet:bus_thermo_zone:mybridge:LR_zone:temperature", ga="thermostatTemperatureAmbient" }
|
||||
Number:Temperature iLR_zone_setTemp "SetPoint Temperature" (gLivingRoomZone) { channel="openwebnet:bus_thermo_zone:mybridge:LR_zone:setpointTemperature", ga="thermostatTemperatureSetpoint" }
|
||||
String iLR_zone_fanSpeed "FanSpeed" (gLivingRoomZone) { channel="openwebnet:bus_thermo_zone:mybridge:LR_zone:speedFanCoil" }
|
||||
@@ -363,15 +383,21 @@ String iLR_zone_actuators "Actuators" (g
|
||||
String iLR_zone_hv "Heating valves" (gLivingRoomZone) { channel="openwebnet:bus_thermo_zone:mybridge:LR_zone:heatingValves" }
|
||||
String iLR_zone_cv "Conditioning valves" (gLivingRoomZone) { channel="openwebnet:bus_thermo_zone:mybridge:LR_zone:conditioningValves" }
|
||||
|
||||
Number:Temperature iEXT_temp "Temperature [%.1f %unit%]" (gExternal) { channel="openwebnet:bus_thermo_sensor:mybridge:EXT_tempsensor:temperature" }
|
||||
Number:Temperature iEXT_temp "Temperature [%.1f %unit%]" (gExternal) { channel="openwebnet:bus_thermo_sensor:mybridge:EXT_tempsensor:temperature" }
|
||||
|
||||
String iCENPlusProxyItem "CEN+ Proxy Item"
|
||||
|
||||
String iAlarm_activation "Alarm Activation" { channel="openwebnet:bus_aux:mybridge:Alarm_activation:aux"}
|
||||
|
||||
Switch iLR_IR_sensor "Sensor" { channel="openwebnet:bus_dry_contact_ir:mybridge:LR_IR_sensor:sensor" }
|
||||
|
||||
Switch iLR_IR_sensor "Sensor" { channel="openwebnet:bus_dry_contact_ir:mybridge:LR_IR_sensor:sensor" }
|
||||
|
||||
// alarm aux, alarm unit and a zone
|
||||
String iAlarm_Control "Alarm Control Arm/Disarm" (gAlarm) { channel="openwebnet:bus_aux:mybridge:Alarm_Control:aux"}
|
||||
Switch iAlarm_System_State "Alarm state" (gAlarm) { channel="openwebnet:bus_alarm_system:mybridge:Alarm_Sys:state" }
|
||||
Switch iAlarm_System_Armed "Alarm armed" (gAlarm) { channel="openwebnet:bus_alarm_system:mybridge:Alarm_Sys:armed" }
|
||||
Switch iAlarm_System_Network "Alarm network" (gAlarm) { channel="openwebnet:bus_alarm_system:mybridge:Alarm_Sys:network" }
|
||||
String iAlarm_System_Battery "Alarm battery" (gAlarm) { channel="openwebnet:bus_alarm_system:mybridge:Alarm_Sys:battery" }
|
||||
Switch iAlarm_Zone_3_State "Zone 3 state" (gAlarm) { channel="openwebnet:bus_alarm_zone:mybridge:Alarm_Zone_3:state" }
|
||||
String iAlarm_Zone_3_Alarm "Zone 3 alarm" (gAlarm) { channel="openwebnet:bus_alarm_zone:mybridge:Alarm_Zone_3:alarm" }
|
||||
```
|
||||
|
||||
Example items linked to OpenWebNet ZigBee devices:
|
||||
@@ -419,10 +445,15 @@ sitemap openwebnet label="OpenWebNet Binding Example Sitemap"
|
||||
Switch item=iCENPlusProxyItem label="My CEN+ scenario" icon="movecontrol" mappings=[ON="Activate"]
|
||||
}
|
||||
|
||||
Frame label="Alarm activation via AUX command"
|
||||
Frame label="Alarm"
|
||||
{
|
||||
Switch item=iAlarm_activation icon="siren"
|
||||
|
||||
Switch item=iAlarm_System_State label="Alarm state"
|
||||
Switch item=iAlarm_Control label="Arm/Disarm alarm" icon="shield"
|
||||
Switch item=iAlarm_System_Armed label="Armed" icon="shield"
|
||||
Switch item=iAlarm_System_Network label="Network" icon="network"
|
||||
Default item=iAlarm_System_Battery label="Battery" icon="battery"
|
||||
Switch item=iAlarm_Zone_3_State label="Zone 3 state"
|
||||
Default item=iAlarm_Zone_3_Alarm label="Zone 3 alarm" icon="siren"
|
||||
}
|
||||
}
|
||||
```
|
||||
@@ -467,6 +498,7 @@ when
|
||||
then
|
||||
sendCommand(iLR_dimmer, DECREASE)
|
||||
end
|
||||
|
||||
```
|
||||
|
||||
## Notes
|
||||
@@ -486,5 +518,6 @@ Special thanks for helping on testing this binding go to:
|
||||
[@gabriele.daltoe](https://community.openhab.org/u/gabriele.daltoe),
|
||||
[@feodor](https://community.openhab.org/u/feodor),
|
||||
[@aconte80](https://community.openhab.org/u/aconte80),
|
||||
[@rubenfuser](https://community.openhab.org/u/rubenfuser)
|
||||
[@rubenfuser](https://community.openhab.org/u/rubenfuser),
|
||||
[@stamate_viorel](https://community.openhab.org/u/stamate_viorel)
|
||||
and many others at the fantastic openHAB community!
|
||||
|
||||